Savillex Technical Note Performance of the DST-1000 Acid Purification System

Similar documents
Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

ICP-MS Analysis of Bulk & Process Chemicals for Semiconductor Processes. Ann O Connell Chemical Analysis Eng Intel Corporation

Sample Analysis Design. Solution Mode

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

Rapid determination of five arsenic species in polished rice using HPLC-ICP-MS

NICKEL-63/59 IN WATER

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Method for estimation of iodine in urine

enable measurement. This method separates these isotopes effectively.

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Test Method: CPSC-CH-E

Automated Determination of PPQ Levels of Thorium in High Purity Copper

URANIUM IN SOIL. Analytical Procedure (2 GRAM SAMPLE) 1. SCOPE

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

Contamination Monitoring of Semiconductor Processes by VPD HR-ICPMS

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

High purity acids and bases

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Properties of Liquids

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Sodium Chloride - Analytical Standard

Method NumberUSTUR 150

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Contact Person(s) : Anna Berne APPLICATION

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

METHOD 3520C CONTINUOUS LIQUID-LIQUID EXTRACTION

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Flk = Acy + Cy z. Discover the perfect formula Fluka Reagents. Fluka TM Accuracy Consistency AUTHENTIC

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Cyanide, Total or Weak Acid Dissociable, by Manual Distillation - PBM

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

THORIUM, PLUTONIUM, AND URANIUM IN WATER

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Automation of the radiochemical procedures for the sequential separation of radionuclides

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Basic Digestion Principles

RNA Transport. R preps R preps

Single Analyte Custom Grade Solution. CGWH2O1 M2-W H2O µg/ml ea: Tungsten Ammonium Metatungstate

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Contact Person : Marie Lawrence APPLICATION

Environmental Series - Trace contaminant analysis in brine using a Thermo Scientific icap 6000 Series Duo ICP

TECHNETIUM-99 IN WATER

Industrial Hygiene Report

DRAFT EAST AFRICAN STANDARD

Determination of trace anions in concentrated hydrofluoric acid

SAFETY NOTE: Before beginning this procedure, read all of the Material Safety Data Sheets for the chemicals listed in Section 5 of this procedure.

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

USGS Troy WSC Laboratory Inductively Coupled Plasma- NH4Cl Soil Extracts SOP 425 Jordan Road Rev. No. 2.0 Troy, NY Date: 03/16/2012 Page 1 of 7

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

ICP-OES measurement of some transition metals in HF acid media

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Carbonate content. SCAN-N 32:98 Revised White, green and black liquors and burnt lime sludge

Rapid Analytical Methods for Determination of Actinides

20 YEARS OF ANALYTICAL EXCELLENCE. A Quantum Global Technologies, LLC company

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

Background Statement for SEMI Draft Document #5329 NEW STANDARD: GUIDE FOR TRIS(DIMETHYLAMINO) SILANE (3DMAS)

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) Acidimetric NIST SRM 84L Lot Number: 84L

Toxicology Extraction Procedure for Base Drugs Using United Chemical Technologies Clean Screen Extraction Columns

The problems as we saw them were;

Oddo-Harkins rule of element abundances

Eichrom Technologies, Inc. Analytical Procedures Rev. 1.5 February 10, 2005 Page 1 of 9

FEATURE ARTICLE. The CS-100 Series High-precision Chemical Solution Monitor in the Semiconductor Cleaning Process. Takaaki Yada.

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Corn Syrup Analysis E-51-1 PHOSPHORUS

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Samples compliant with the WATER

Experiment C-15 Distillation - part 1

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Laboratory ID. Laboratory Name. Analyst(s) Auditor. Date(s) of Audit. Type of Audit Initial Biennial Special ELCP TNI/NELAP.

Aspirin Synthesis H 3 PO 4

Exp t 111 Structure Determination of a Natural Product

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

Pu and Np-237 in seawater samples Version /03/14. Summary

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3103a Lot Number:

USGS District Laboratory, Troy, NY Dissolved Inorganic Carbon Analysis Standard Operating Procedure

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method

Nitrofuran (SEM) ELISA test Kit

METHOD 9012 TOTAL AND AMENABLE CYANIDE (COLORIMETRIC, AUTOMATED UV)

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Lab 2. Go Their Separate Ways: Separation of an Acid, Base, and Neutral Substance by Acid-Base Extraction

Activity 2: Determine the Effect of Temperature on the Reaction Rate

IAEA-TECDOC-9SO. Sampling, storage

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3163 Lot Number:

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution

Non-Interfering Protein Assay Kit Cat. No

Transcription:

Savillex Technical Note Performance of the DST-1000 Acid Purification System Summary The Savillex DST-1000 acid purification system is a sub-boiling still manufactured from PFA that produces high purity acid from cheaper, lower grade acids. A new DST-1000 was installed inside a fume hood in a semiconductor clean room and used for the purification of trace metal grade (1ppb) HF. The first 15 batches of HF produced by the DST-1000 from trace metal grade were analyzed for trace metals using ICP-MS. For comparison, high purity grade (10ppt) HF was purchased and also analyzed. By the 15th batch, the HF produced by the DST-1000 was equivalent in quality to commercial high purity grade. Trace metal data for purified HNO 3 and HCL is also given. All acid was produced using the DST-1000 controller on HIGH setting, which produces 500mL of high purity acid in approx. 15 hours. The DST-1000 has been shown to produce very high quality acid, at a fraction of the cost of commercially available high purity grade. In addition, since the DST-1000 produces fresh acid on demand, the degradation in quality over time with commercial high purity acid (as the bottle is repeatedly opened) is avoided. Savillex DST-1000 Acid Purification System Methodology The work described in this note was performed at a semiconductor R&D lab. All cleaning, sample collection, and sample analysis was performed in a Class 1 clean room, maintained at a constant temperature of 20.4deg.C. The DST-1000 was placed in a fume hood, while the controller was outside the hood. The DST-1000 was new and unused, so that the initial quality of the acid produced, and time taken to reach high purity, could be measured. Initial cleaning following the recommend procedure was performed: following unpacking, but prior to connecting the outlet tubing to the collection bottle, 500mL of HF was placed in the DST-1000 and the unit was operated with the temperature controller set to HIGH for 48 hours. The unit is initially cleaned by the refluxing acid, which is then discarded. This procedure was repeated with DI water and the unit was then ready for use. The outlet and collection bottle were connected, and 15 successive distillations (batches) of 1L trace metal grade HF were performed and collected. In all cases the controller was set to HIGH (fastest distillation rate). At the end of each batch, the remaining acid (approx. 50mL) in the DST-1000 was drained and discarded. Trace metal grade HNO 3 and HCl acid were purified on separate DST-1000s, which has been previously used. Note: if multiple acids are to be purified, it is recommended to dedicate a separate DST-1000 for each acid. Analysis - HF Trace metal analysis was performed on the 1st, 5th and 15th batches of HF produced. Replicate samples of each batch were preconcentrated using an in-house preconcentration system, along with replicates of a new bottle of commercial high purity HF and trace metal grade HF. A blank and spike recovery were also prepared with each replicate. The samples were then analyzed using an Agilent 7500cs ICP-MS.

Table 1 shows the detection limits reported using the preconcentration technique, and analytical data for the commercial high purity (10ppt) grade HF, trace metal (1ppb) grade HF and the 3 distilled batches. Table 1. Analytical data for HF obtained using ICP-MS. All data in ppt. As can be seen, by the 5th batch, the distilled HF produced by the DST-1000 is very close to the quality of the commercial high purity HF, and by the 15th batch is essentially of equivalent purity. The analysis of trace metal grade HF shows the amount of trace contaminants removed by the DST-1000.

Analysis - HNO 3 and HCl The analysis of DST-1000 HNO 3 and HCl was performed separately using different DST-1000 units. Analysis was performed using a combination of collision/reaction cell and sector field ICP-MS. In this case, commercial 10ppt grade was used as a blank and subtracted from the results. DLs were slightly higher than for the HF analysis since pre-concentration was not used for HNO 3 and HCl. Data for DST-1000 produced acid are shown in tables 2 and 3. The analysis of 1ppb commercial acid is also shown for comparison. As can be seen, trace metal content of the DST-1000 produced acids is below the DL for every analyte except Na in HCl, which was just above the DL. Table 2. Analytical data for HNO 3 obtained using ICP-MS. All data in ppt.

Table 3. Analytical data for HCl obtained using ICP-MS. All data in ppt. Distillation Rates The DST-1000 controller has 3 temperature settings: LOW, MEDIUM and HIGH. These control the temperature (and therefore distillation rate) by adjusting the amount of time at which power is supplied to the heater. At HIGH setting, the heater is on continuously, and the temperature of the acid is approx. 90deg. C (sub-boiling conditions are maintained). This means that the DST-1000 cannot be set to too high a temperature, which would cause boiling and allow contaminants to be transferred with the distilled acid. Following the initial HF distillations and sample analysis, production rates for HF, HNO 3 and HCl were calculated over a 6 hour time period using the different controller settings. These are shown in table 4: different mineral acids distil at slightly different rates. On the HIGH setting, 500mL of acid is distilled in 12-15 hours depending on the acid. Operated overnight, the DST-1000 will produce 500mL of high purity acid ready for use each morning.

Table 4. Distillation rates for various acids at different controller settings. From the data shown here it is unlikely that acid quality can be further improved by using the low distillation rates, (LOW and MEDIUM settings), however these settings are useful for operating the DST-1000 over a weekend without the system evaporating to dryness. A great benefit of the DST-1000 is that fresh high purity acid is always available. Commercial high purity acid, while of excellent quality when first opened, deteriorates each time the bottle is opened. User Observations The following comments on the DST-100 were made by the semiconductor chemists who performed the work described in this note. Initial set-up and cleaning, following the Savillex manual was simple and efficient No additional facilities were required (i.e. water cooling) to operate the unit. This simplifies and improves the overall value of the unit. The overall footprint is small and welcomed since hood space is precious in a cleanroom lab. HNO 3 does not discolor during the distillation process - we have observed this with other distillation systems. The reservoir is simple and safe to fill. The slower distillation rate settings are convenient for weekend or 24 hr. operation. Low maintenance after initial cleaning. Recommend to dedicate a DST-1000 to only one acid type. Note: This lab now has four DST-1000 systems, operating continually. TN006 021112