Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Similar documents
Finnigan LCQ Advantage MAX

Thermo Finnigan LTQ. Specifications

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

LCQ Fleet Ion Trap LC/MS n Exceptional Analytical Value

Thermo Scientific TSQ Quantum Ultra Ultra AM/Ultra EMR Performance Specifications

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap

Translational Biomarker Core

ABI 3200 Q TRAP LC/MS/MS System

Introduction to the Q Trap LC/MS/MS System

TANDEM MASS SPECTROSCOPY

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Extrel is widely respected for the quality of mass spectrometer systems that are

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

Accurate, High-Throughput Protein Identification Using the Q TRAP LC/MS/MS System and Pro ID Software

Mass Spectrometry in MCAL

Information Dependent Acquisition (IDA) 1

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Analysis of Polar Metabolites using Mass Spectrometry

Tandem MS = MS / MS. ESI-MS give information on the mass of a molecule but none on the structure

[ instrument specifications ]

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Multi-residue analysis of pesticides by GC-HRMS

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Why Use the LCQ Advantage MS

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Technical Note # TN-35 amazon Ion Trap: New Performance Levels Meeting Demanding Analytical Requirements

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

ICP-MS. High Resolution ICP-MS.

Catalysis CAPABILITIES

Analytical Instrumentation

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

API Optimization, Source Design, and Other Considerations of LC/MS

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

Agilent ESI and APCI sources: for polar to non-polar compounds

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

LC-MS Based Metabolomics

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Defining quality standards for the analysis of solid samples

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Petrochemical. Transformer Oil Gas Analysis - TOGA

1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Nanoporous GaN-Ag Composite Materials Prepared by Metal-Assisted Electroless Etching

Powerful Scan Modes of QTRAP System Technology

High-Field Orbitrap Creating new possibilities

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Quattro Micro - How does it work?

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Theory and Practical Consequences.

M M e M M H M M H. Ion Sources

SIFT-MS. technology overview

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Fusion UV/Persulfate TOC Analyzer

Agilent G3212 GC-APCI Source

Rapid Distinction of Leucine and Isoleucine in Monoclonal Antibodies Using Nanoflow. LCMS n. Discovery Attribute Sciences

SUPPORTING INFORMATION Antimicrobial activity of chlorinated amino acids and peptides

WADA Technical Document TD2003IDCR

The sercon group Isotope Ratio Mass

Mass Spectrometry for Chemists and Biochemists

IN QUALITATIVE ANALYSIS,

Field-Free Atmospheric Ionization: Atmospheric Pressure Chemical Ionization & Electrospray

Ion traps. Quadrupole (3D) traps. Linear traps

Types of Analyzers: Quadrupole: mass filter -part1

Varian Galaxie Chromatography Data System for Preparative HPLC

Analyst Software. Automatic Optimization Tutorial

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

WALKUP LC/MS FOR PHARMACEUTICAL R&D

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

PERSPECTIVE STABLE ISOTOPE RATIO MS

Applications of LC/MS in Qualitative Drug Metabolite Studies

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

UPLC Intact MASS Analysis Application Kit

Matching UHPLC Resolution and Speed with Agilent Ultra High Definition Q-TOF Technology

Agilent All Ions MS/MS

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

MICROMASS Q-Tof micro MASS SPECTROMETER

PERSPECTIVE STABLE ISOTOPE RATIO MS

4000 Q TRAP LC/MS/MS System. Advanced Linear Ion Trap technology at the highest level of sensitivity 4000 QTRAP. LC/MS/MS System

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Transcription:

www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment LCQ Deca XP Plus Improved Ion Optics for Greater Sensitivity and Precision The LCQ Deca XP Plus, the latest addition to the LCQ family, redefines sensitivity and performance in an ion trap mass spectrometer. With enhanced ion optics and Ion Sweep gas, the LCQ Deca XP Plus delivers superior sensitivity and non-stop data generation for a variety of advanced LC/MSn applications. Fullyautomated MSn capabilities and advanced Data Dependent experiment design features make analysis of low-abundance compounds in any matrix routine. Powerful Xcalibur software accelerates data analysis and simplifies the generation of results while providing a single platform to control LC/MSn experiments. With cutting-edge hardware design, outstanding reliability and intelligent software, the LCQ Deca XP Plus is the benchmark instrument for applications such as metabolism and proteomics. Quadrupole Ion Trap Mass Spectrometer The LCQ Deca XP Plus couples an orthogonal API source and Ion Sweep gas with industry leading Data Dependent tools, creating the most flexible and sensitive ion trap mass spectrometer ever. The industry s first APCI/APPI combination ion source allows ionization of compounds not classically accessible to LC/MSn. Hardware Features Orthogonal API Source - Enhanced sensitivity and ruggedness - Sweep Gas reduces chemical noise - Removable metal ion capillary tube provides vent-free maintenance Transfer Ion Optics - Octapole and square quadrupole lenses - Split voltage quadrupole lens to eliminate noise - High stability and ion transmission efficiency New Inter-Multipole Lens - Lens orifice optimized to increase sensitivity and enhance precision Entrance Lens - Improves injection of ions into the trap Quadrupole Ion Trap Mass Spectrometer - Analyzer dimensions optimized for ultimate performance Page 1 of 6

- Simple, rugged construction for ease of maintenance - Regulated helium flow for stable operation - Automatic system calibration and optimization Vacuum System - Differentially-pumped vacuum system to 10-5 Torr - Split-flow turbomolecular pump controls vacuum in two regions - Dual rotary vacuum pump configuration - High-vacuum cast aluminum analyzer chamber Detection System - Patented, post-acceleration conversion dynode with ±15 kv applied voltage - Off-axis continuous dynode electron multiplier with extended dynamic range - Unique direct mounting of the multiplier to the electrometer PCB to eliminate electronic noise - Digital electronic noise discrimination Integrated Divert Valve - Under fully-automated data system control enabling user to switch the solvent front, gradient end point and any other portion of the HPLC run to waste - User-definable default state of the valve, either to waste or to source Integrated Syringe Pump - Dual syringes allow automated infusion under data system control Options - Orthogonal ESI source compatible with liquid flow rates of <1 µl/min to 1 ml/min, without splitting - Orthogonal APCI/APPI source compatible with liquid flow rates of 50 µl/min to 2 ml/min, without splitting - Orthogonal APCI source compatible with liquid flow rates of 50 µl/min to 2 ml/min, without splitting - Metal needle option for highthroughput, low-flow analyses - 96-position sample plate AP MALDI for automated and manual data acquisition - NanoSpray source to support both static and dynamic nanospray experiments, compatible with liquid flow rates of nl/min* to 50 µl/min *Lower limit is dependent on gauge of needle used The fully-integrated Surveyor LCQ Deca XP Plus system combines the ruggedness of an orthogonal API source with the specificity of MSn, creating the most sensitive quadrupole ion trap mass spectrometer available. Features and Technical Specifications Page 2 of 6

The LCQ Deca XP Plus uses the MSn Browser, a viewer that shows in list format the progeny of each ion resulting from a Data Dependent Ion Tree experiment. Also displayed is the total composite spectrum, a summation of the fragments generated during an MSn Ion Tree experiment. Software Features Data System - Xcalibur processing and instrument control software - LCQUAN quantitation package - Microsoft Office professional software package - High-performance PC with Intel Pentium microprocessor - High-resolution color monitor Scan Functions - Full-scan feature provides full-scan mass spectra for sensitive analyses and produces spectra for rapid screening of unknown compounds - Selected Ion Monitoring (SIM) for monitoring of selected ions for target compound analysis - Full-scan MS/MS produces full-scan product ion spectra at sensitivities higher than any quadrupole ion trap mass spectrometer - Selected Reaction Monitoring (SRM) for a traditional LC/MS/MS quantitative analytical experiment - MSn for multi-stage MS experiments to probe the structure of ions - ZoomScan, a high-resolution, narrowrange scan to resolve isotopic envelopes which is often used for charge state determination of peptides and ionization state determination of organometallics - TurboScan, an ultra-fast scan to improve signal-to-noise and sampling rate Exclusive Technologies - Unique, patented Automatic Gain Control (AGC) performs a short prescan before each analytical scan, ensuring that the ion trap is always filled with the optimum number of ions for any scan type Page 3 of 6

- Dynamic Exclusion temporarily puts an ion onto an exclusion list after its spectrum has been acquired, allowing acquisition of MS/MS and MSn spectra on less intense coeluting compounds - WideBand Activation fragments the water loss ion within an MS/MS spectrum, generating more structurally informative spectra - Normalized Collision Energy compensates for the mass dependent energy deposition characteristics of ion trap mass spectrometers in MS/MS experiments and provides reproducible data from instrument to instrument Advanced Data Dependent Experiments - Data Dependent features trigger acquisition of MSn spectra only when a compound of interest is detected - Isotopic Data Dependent scanning performs MS/MS only when a userdefined isotopic pattern is detected - Triple Play determines the charge state and MS/MS spectrum for a multiply charged ion - Nth Order Triple Play allows the number of ions undergoing a Triple Play to be defined - Ion Mapping automatically generates a 3-dimensional MS/MS map, yielding production, precursor ion and neutral loss data - Data Dependent Ion Tree performs MSn experiments on up to 25 ions Data Dependent Zoom Map generates sequential MS/MS experiments using a ZoomScan for charge state determination prior to each MS/MS experiment - Ion Mapping Browser software for viewing data generated by Ion Mapping experiments - MSn Browser software for viewing data generated by Data Dependent Ion Tree and Ion Mapping experiments - Optional Application-Specific Software - BioWorks /SEQUEST /TurboSEQUEST... protein identification tools - Mass Frontier...spectral interpretation and classification software to identify unknowns - Metabolite ID...rapid review and reporting of drug metabolism data - Discovery Browser...Open Access and combinatorial software - NIST Library software System Specifications MS/MS Sensitivity Electrospray Ionization (ESI) A loop injection of 2 µl of a 1 pg/µl solution of reserpine (2 picograms [3 femtomoles] total sample) at a flow of 350 µl/min of 50% isopropyl alcohol/50% water will produce a minimum signal-to-noise ratio of 50:1, for the transition of the unit isolated protonated molecular ion at m/z 609 to the largest product ion, when the mass spectrometer is operated at unit resolution in the fullscan MS/MS mode, scanning the product ion spectrum from m/z 165-615. Page 4 of 6

Atmospheric Pressure Chemical Ionization (APCI) A loop injection of 2 µl of a 1 pg/µl solution of reserpine (2 picograms [3 femtomoles] total sample) at a flow of 400 µl/min of 50% isopropyl alcohol/50% water will produce a minimum signal-tonoise ratio of 50:1, for the transition of the unit isolated protonated molecular ion at m/z 609 to the largest product ion, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165-615. Installation Requirements Power - One 230 Vac ±10.0%, 15 Amps, 50/60 Hz, single phase, with earth ground dedicated to the instrument - 120 or 230 Vac single phase, with earth ground for the data system Gas - One high-purity (99% pure, flow rate 15 L/hr) nitrogen gas supply for the API source - One ultra-high-purity helium gas supply (99.998% pure) with less than 1 ppm each of water, oxygen and total hydrocarbons for the mass analyzer Environment - System averages 8000 Btu/h (2300 W) output when considering air conditioning needs - Operating environment must be 15-27 C (59-80 F) and relative humidity must be 4-80% with no condensation - Optimum operating temperature is 18-21 C (65-70 F) Dimensions/Weight - MS: 56 cm x 79 cm x 76 cm (h x w x d) - MS: ~120 kg - Two roughing pumps: 38.6 kg each Performance Specifications Mass Ranges - m/z 15 200 - m/z 50 2000 - m/z 100 4000 - m/z 1000 20,000* *Available with optional Developer s Kit Software Scan Power - MSn, for n = 1 through 10 Contact Closure - Start In/Out - Start Out is programmable Analog Inputs -Two (2) analog Inputs (0-1 V) Page 5 of 6

www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Page 6 of 6