arxiv:physics/ v2 [physics.med-ph] 8 Jan 2003

Similar documents
arxiv:physics/ v1 [physics.med-ph] 8 Jan 2003

Interbeat interval. Beat number. Interbeat interval. Beat number. h max

DYNAMIC ANALYSIS OF THE CORRELATION INTEGRAL OF HEART RATE VARIABILITY IN HYPERTROPHIC CARDIOMYOPATHY PATIENTS

WORKING ON THE NOLTISALIS DATABASE: MEASUREMENT OF NONLINEAR PROPERTIES IN HEART RATE VARIABILITY SIGNALS

International Journal of Advanced Research in Computer Science and Software Engineering

Is the Heart Rate of an Endurance Triathlete Chaotic?

DYNAMICAL ANALYSIS OF HEART BEAT FROM THE VIEWPOINT OF CHAOS THEORY

Dynamics of partial discharges involved in electrical tree growth in insulation and its relation with the fractal dimension

NONLINEAR TIME SERIES ANALYSIS, WITH APPLICATIONS TO MEDICINE

CHAPTER 10 PERMUTATION ENTROPY, MULTISCALE PERMUTATION ENTROPY AND WAVELET TRANSFORM ANALYSIS OF HEART RATE VARIABILITY

A New Approach to the Study of Heartbeat Dynamics Based on Mathematical Model

arxiv:physics/ v2 [physics.med-ph] 7 Feb 2003

Detection of Nonlinearity and Stochastic Nature in Time Series by Delay Vector Variance Method

The Behaviour of a Mobile Robot Is Chaotic

HEART RATE VARIABILITY AS DETERMINISM WITH JUMP STOCHASTIC PARAMETERS

Simple approach to the creation of a strange nonchaotic attractor in any chaotic system

Multiscale Analysis of Heart Rate Variability: A Comparison of Different Complexity Measures

Magnitude and sign scaling in power-law correlated time series

K. Pyragas* Semiconductor Physics Institute, LT-2600 Vilnius, Lithuania Received 19 March 1998

Investigation of Dynamical Systems in Pulse Oximetry Time Series

Multifractal Models for Solar Wind Turbulence

Heuristic segmentation of a nonstationary time series

ASYMMETRIC DETRENDED FLUCTUATION ANALYSIS REVEALS ASYMMETRY IN THE RR INTERVALS TIME SERIES

If we want to analyze experimental or simulated data we might encounter the following tasks:

Spatial Synchronization in the Human Cardiovascular System

Minimizing the effect of trends on detrended fluctuation analysis of long-range correlated noise. Radhakrishnan Nagarajan

Dynamical systems, information and time series

SUPPLEMENTARY INFORMATION

Phase Desynchronization as a Mechanism for Transitions to High-Dimensional Chaos

Model for cardiorespiratory synchronization in humans

Sample Entropy based HRV: Effect of ECG Sampling Frequency

Modelling Heart Rate Variability

Deviations from uniform power law scaling in nonstationary time series

Influence of Age on Cardio-Respiratory Interaction Assessed by Joint Symbolic Dynamics

congestive heart failure Hh,02.50.Ey, y,05.40.Fb

Complete synchronization and generalized synchronization of one-way coupled time-delay systems

Synchronization of Limit Cycle Oscillators by Telegraph Noise. arxiv: v1 [cond-mat.stat-mech] 5 Aug 2014

Phase Synchronization in Temperature and Precipitation Records

Detecting chaos in pseudoperiodic time series without embedding

Introduction to time-frequency analysis Centre for Doctoral Training in Healthcare Innovation

Complex Dynamics of Microprocessor Performances During Program Execution

Non-linear dynamics and chaotic indices in heart rate variability normal subjects and heart-transplanted patients

Independence and symbolic independence of nonstationary heartbeat series during atrial fibrillation

Quantitative Description of Robot-Environment Interaction Using Chaos Theory 1

The dynamics of human gait

Predicting Phase Synchronization for Homoclinic Chaos in a CO 2 Laser

DYNAMIC ANALYSIS ON THE HEART ELECTROMAGNETIC ACTIVITY

Information-Based Similarity Index

Chapter 2 Chaos theory and its relationship to complexity

Diverse routes to oscillation death in a coupled oscillator system

Biological Systems Modeling & Simulation. Konstantinos P. Michmizos, PhD

Interactive comment on Characterizing ecosystem-atmosphere interactions from short to interannual time scales by M. D. Mahecha et al.

Interbeat RR Interval Time Series Analyzed with the Sample Entropy Methodology

Phase-Space Reconstruction. Gerrit Ansmann

arxiv:physics/ v1 [physics.bio-ph] 5 Oct 2004

Nonlinear dynamics of heart rate variability in cocaine-exposed neonates during sleep

Change ΔS of the entropy in natural time under time reversal: Complexity measures upon change of scale

Investigations of Cardiac Rhythm Fluctuation Using the DFA Method

Two Decades of Search for Chaos in Brain.

Experiments with a Hybrid-Complex Neural Networks for Long Term Prediction of Electrocardiograms

Discrimination power of measures for nonlinearity in a time series

Algorithms for generating surrogate data for sparsely quantized time series

A comprehensive model using modified Zeeman model for generating ECG signals

Abstract. Introduction. B. Sivakumar Department of Land, Air & Water Resources, University of California, Davis, CA 95616, USA

Characterizing chaotic time series

SIMULATED CHAOS IN BULLWHIP EFFECT

Effects of data windows on the methods of surrogate data

Self-organized Criticality and Synchronization in a Pulse-coupled Integrate-and-Fire Neuron Model Based on Small World Networks

Comparison of Nonlinear Dynamics of Parkinsonian and Essential Tremor

Distinguishing chaos from noise

However, in actual topology a distance function is not used to define open sets.

Analyzing Employee s Heart rate using Nonlinear Cellular Automata model

Detecting temporal and spatial correlations in pseudoperiodic time series

What is Nonlinear Dynamics? HRV 2006: Techniques, Applications, and New Directions. Daniel Kaplan Macalester College Saint Paul, Minnesota

7 Coupled oscillators approach in analysis of bivariate data

The projects listed on the following pages are suitable for MSc/MSci or PhD students. An MSc/MSci project normally requires a review of the

What is Chaos? Implications of Chaos 4/12/2010

Entropy in the natural time domain

NONLINEAR DYNAMICS AND CHAOS. Facilitating medical diagnosis. Medical classifications

On multiscale entropy analysis for physiological data

Fractals in Physiology

Ahsan Habib Khandoker Chandan Karmakar Michael Brennan Andreas Voss Marimuthu Palaniswami. Poincaré Plot Methods for Heart Rate Variability Analysis

Characteristics and synchronization of time-delay systems driven by a common noise

JC: You want to see self-organization at work? Test each part of the circuit one by one. You ll see that the whole is more than the sum of its parts

Characterization of phonemes by means of correlation dimension

Putting your heart into physics

Information Flow/Transfer Review of Theory and Applications

Determination of fractal dimensions of solar radio bursts

Application of Physics Model in prediction of the Hellas Euro election results

Malvin Carl Teich. Boston University and Columbia University Workshop on New Themes & Techniques in Complex Systems 2005

Detecting abnormality in heart dynamics from multifractal analysis of ECG signals

exponents and mode-locked solutions for integrate-and-fire dynamical systems

Multiscale Analysis of Complex Time Series by Scale Dependent Lyapunov Exponent

modeling in physiology

Directionality of coupling from bivariate time series: How to avoid false causalities and missed connections

Robust and Sensitive Method of Lyapunov Exponent for Heart Rate Variability

Vulnerability of economic systems

Investigation of Chaotic Nature of Sunspot Data by Nonlinear Analysis Techniques

arxiv:nlin/ v1 [nlin.cd] 25 Apr 2001

Overture: Why is Physiologic Variability Important?

Transcription:

What does measure the scaling exponent of the correlation sum in the case of human heart rate? M. Säkki, J. Kalda Institute of Cybernetics, Tallinn Technical University, Akadeemia tee 21, 12618 Tallinn, Estonia M. Vainu Tallinn Diagnostic Center, Pärnu mnt. 104, Estonia arxiv:physics/0112031v2 [physics.med-ph] 8 Jan 2003 M. Laan Nõmme Children Hospital, Laste 1, Tallinn, Estonia It is shown that in the case of human heart rate, the scaling behaviour of the correlation sum (calculated by the Grassberger-Procaccia algorithm) is a result of the interplay of various factors: finite resolution of the apparatus (finite-size effects), a wide dynamic range of mean heart rate, the amplitude of short-time variability being a decreasing function of the mean heart rate. The value of the scaling exponent depends on all these factors and is a certain measure of short-time variability of the signal. PACS numbers: PACS numbers: 87.10.+e, 87.80.Tq, 05.45.-a, 05.45.Tp Heart rate variability (HRV) is often thought to be driven by deterministic chaos inside the heart. This chaos is explained in terms of dynamics of the complex of sinoatrial and atrio-ventricular nodes, which has been successfully modeled as a system of non-linear coupled oscillators, responsible for the heart rhythm [1, 2]. As a consequence, correlation dimension and related quantities (like Lyapunov exponents and Kolmogorov entropy, etc.) have been thought to be importanon-linear measures of HRV. In particular, Babloyantz and Destexhe concluded [3] that high values of the correlation dimension indicate the healthiness of the heart. Later, the correlation dimension of the heart rate signal has been calculated in a vasumber of papers. Meanwhile, it has been pointed out that physiological time-series are typically non-stationary and noisy, and therefore, the correlation dimension cannot be calculated reliably [4, 5, 6] the fact which is now widely accepted. In the case of human heart, the noise comes from the autonomous nervous system in the form of inputs regulating the heart rate (cf. [7, 8, 9]). These mostly non-deterministic signals suppress almost completely the underlying deterministic signal. Futhermore, it has been emphasized that a reasonable fitting of a correlation sum to a power law does noecessarily mean that the obtained exponent is the correlation dimension of the underlying dynamical system; instead, thorough non-automatable verification procedure has to be done [10]. All this leads us to the conclusion that the formally calculated correlation dimension of a heart rhythm does not correspond to the dimensionality of an intrinsic attractor. Thus, there are two important observations: (a) the correlation sums of human heart rate follow typically a scaling law; (b) in most cases, the scaling exponents are not the correlation dimensions. Then, a natural question arises, what is the physical meaning of these formally calculated exponents? Our answer to the posed question is based on very simple observations, which are valid for healthy patients: (a) the long-time variability of the inter-beat intervals (around 500 ms) is typically much higher than the variability on the time scale of few heart beats (less than 50 ms); (b) for those periods, when the mean heart rate is high (i.e. when the subject is performing physical exercise) the heart rate variability is low; (c) the heart rate is controlled by non-deterministic and effectively random signals arriving from the autonomous nervous system. As a consequence, in time delay coordinates, an HRV timeseries generates a baseball bat-shaped cloud of points. Although the theoretical value of the correlation dimension of such a cloud is infinite, the finite resolution of the recording apparatus, finite length of the time-series, and the linear structure of the cloud result in a smaller value. This is evident for a very narrow bat, which is efficiently one-dimensional. In what follows we show that the correlation dimension reflects the geometrical size of the cloud of points. The layout of the paper is as follows. First, we give the details of the HRV database used for this study. Second, we provide a short overview of the research results related to the correlation dimension of human heart rhythm. Third, we construct a simple model-time-series, the correlation sum of which scales almost identically to that of real HRV data. Finally, we discuss the universality and implications of our model. The experimental data analyzed in this paper have been recorded at Tallinn Diagnostic Center. The recordings of ambulatory Holter-monitoring (24 hours, approximately 100 000 data points) were obtained during regular diagnostical examinations and covered over 200 patients with various clinically documented diagnoses (including also many healthy patients). The main groups of patients are shown in Table 1. The resolving power of recordings was 6 ms (sampling rate of 180 Hz). The diagnostics and

2 data verification has been made by qualified cardiologist; the data preprocessing included also filtering of artifacts and arrhythmias. Healthy IHD SND VES PCI RR FSK No. of patients 103 8 11 16 7 11 6 Mean age 45.5 65.4 50.0 55.9 47.3 55.5 11.7 Std. dev. of age 20.5 11.4 19.3 14.3 11.6 14.4 4.6 TABLE I: Test groups of patients. Abbreviations are as follows: IHD - Ischemic Heart Disease (Stenocardia); SND - Sinus Node Disease; VES - Ventricular Extrasystole; PCI - Post Cardiac Infarction; RR - Blood Pressure Disease; FSK - Functional Disease of Sinus Node. The concept of correlation dimension, introduced by Grassberger and Procaccia [11], is designed to reflect the number of degrees of freedom of a deterministic system (or the dimensionality of an attractor, which, in principle, can be fractal). For empirical time-series, the phase variables are typically not known. It is expected that the attractors in the phase space are topologically equivalent to the attractors in a reconstructed phase space with timelag coordinates {x(t), x(t+τ),... x[t+(m 1)τ]}, as long as the embedding dimensionality m (the dimensionality of the reconstructed phase space) exceeds the dimensionality of the attractor D; here x(t) is the signal, and τ is a reasonably chosen time lag. This circumstance is exploited by the Grassberger-Procaccia method [11] for the calculation of the correlation dimension. To begin with, the second order correlation sum is defined as C 2 (r) = 2 N(N 1) θ(r r i r j ), (1) i<j where θ(r) is the Heaviside function, and r i = {x(t i ), x(t i + τ),..., x[t + (m 1)τ]}, is a point in the reconstructed phase space, and i = 1, 2,..., N counts the moments of discretized time. For small r, the correlation sum is expected to scale as C 2 (r) r D2, assuming that D 2 < m. The exponent D D 2 is called the correlation dimension of the system. A non-linear dynamical system may be chaotic and then the phase trajectory fills the entire phase space. In that case, the correlation dimension D 2 is equal to the number of degrees of freedom (the dimensionality of the phase space minus the number of conservation laws). This is why D 2 is often considered as a measure of the complexity of the system. Babloyantz and Destexhe [3] studied the correlation dimension of the sequence of NNintervals (intervals between normal heartbeats) of human heart rhythm. For healthy patients and data series consisting of 1000 intervals, they found D = 5.9 ± 0.4. It is widely recognized that life threatening heart pathologies lead to the reduction of the complexity of the HRV signal, c.f. [12]. Correspondingly, the correlation dimension of the heart rate has been often considered as a measure for the healthiness of the heart. However, the heart is not an isolated system. Although the heart rhythm is generated by the complex of oscillatory elements, its rate is controlled by non-deterministic inputs arriving from the autonomous nervous system. In particular, these inputs lead to the increase of heart rate when the subject is under physical stress, and to slowing down when the subject is at rest, c.f. [8]. Healthy heart responds easily to these signals, and is able to adapt to a wide range of beating rates. This responsiveness gives rise to the high variability of the heart rate. Severe heart diseases decrease the responsiveness of the heart with respect to the whole spectrum of signals arriving from the autonomous nervous system; this leads to the loss of apparent complexity of the HRV signal. The heart is more responsive with respect to the signals of the autonomous nervous system when the heart rate is slow, i.e. when the patient is at rest. In that case, the heart rate variability is driven by weaker signals, like the ones generated by respiration and blood-pressure oscillations. These two stimuli are quasi-periodic, the periods being respectively a few and 10 20 seconds. It should be noted that respiration can be mode-locked to the heart rate. This mode-locking has been demonstrated by simultaneous recording of ECG and respiration activity, together with the technique called cardiorespiratory synchrogram [13]. The ratio of the mode-locked periods can be small, 2:1, 3:1, 5:2, etc., and the phenomenon can give rise to certain patterns in the reconstructed phase space. These patterns can be easily misinterpreted as traces of an attractor of a non-linear deterministic system, therefore we discuss this aspect in more details. As mentioned above, HRV signals generate a baseballbat-shaped cloud of points in a time-lag space. For certain patients, the presence of less densely populated satellite clouds can be observed, see Fig. 1 (note that due to the sparse population of these clouds, the presence or absence of the clouds has almoso effect on the value of D). We were able to show that for all such patients of our database, the satellite clouds were not related to a deterministic chaos inside the heart. To this end, we studied the fluctuation function F(ν) = +ν (2) (angular braces denote averaging over n). Unlike in the case of single-cloud-patients, the fluctuation function of the patients with satellite clouds revealed a presence of an oscillatory component, see Fig. 2a. By dividing the entire 24-hour HRV record into one-hour intervals, and calculating the amplitude of the oscillatory component of the fluctuation function for each interval, we were able to locate the periods responsible for the satellite clouds in the reconstructed phase space, see Fig. 2b. These were always the periods before falling asleep, around 10 or 11 pm, characterized by a low heart rate and a high respiration-driven short-time variability. The phase between the heart rate and respiration is locked during tens of seconds, confirming the observations of Kurths et al. [13]. Thus, in a certain sense, the heart and respiratory complex act as a system of coupled oscillators c.f. [14]; however, there is no determistic chaos inside the heart.

3 Note that our method of mode-locking detection is very simple, does not require synchronous respiration rhythm recording (unlike the thourough method [13]), and can be conviniently used to find relatively short ( > 10min) locking periods from a 24-hour recording. +1 /ms/ +2 + τ = 552 ms +2 = 512 ms 800 552 512 400 400 512 552 800 < 4 4 8 16 32 64 /ms/ FIG. 1: Two-dimensional intersection of 3-dimensional reconstructed phase space for a patient with pronounced modelocking between heart rate and respiration. The number of points per unit cell is given in gray-scale coding. (a) 23:58:50 1 4 16 64 256 1024 4096 16384 1250 1000 (b) ν FIG. 2: Patient with 3:1 mode locking between heart rate and respiration: (a) heart beat intervals (in milliseconds) plotted versus the beaumber. Heart rate has a pronounced oscillatory component; vertical lines mark the period of three heart beats, horizontal lines indicate the sequences with coherent phase. (b) Fluctuation function (arbitrary units) is plotted versus the time lag ν (in heart beats); the oscillating component is magnified. Our model of the heart rhythm generation is as follows. The non-linear deterministic dynamics inside the heart is almost completely suppressed by the signals arriving from the autonomous nervous system. These signals control the mean heart rate, but obey also a noiselike component, the amplitude of which decreases with increasing mean heart rate. In the case of correlation dimension analysis, this noise-like component is indistinguishable from a Gaussian noise. Therefore, theoretically, the correlation dimension is infinite. The reported relatively small values of the correlation dimension are to be attributed to the finite length of the time series and, most importantly, by finite resolution of the recording apparatus. Regarding the length of the record: typically, the correlation dimension has been found to be at the limit (or beyond) of a credible analysis [4, 15]. Indeed, it has been suggested [4, 15] that the calculation of the correlation dimension D is reliable, if the number N of data-points in the time series N > 10D/2+1. (3) In Table 2, this criterion is compared with the data of some papers. Ref. [3] Ref. [5] Ref. [16] Ref. [17] Correlation dimension 5.5 6.3 9.6 10.2 2.8-5.8 4 7 Length of the data set 10 3 2 10 4 10 4 2 10 4 Required length 10 4 10 6 10 4 3 10 4 TABLE II: Data from papers devoted to the correlation dimension analysis: experimental values of correlation dimension, lengths of the underlying data sets, and data-set lengths required by Eq. 3. In order to test our hypothesis we aimed to construct such random time series (using an algorithm as simple as possible), the correlation sum of which is similar to the correlation sums of the time series of real patients. First we analyzed the sequences of NN-intervals extracted from ECG recordings. The scaling exponent was calculated according to the Grassberger-Procaccia algorithm. The six-dimensional embedding phase space was used for calculations. The choice of the embedding dimensionality was motivated as follows. To begin with, the analysis for phase space with m > 6 is not reliable due to sparse clouds of points (see Eq. 3). Further, m = 6 does still make sense, because most of the previous studies have reported D < 6. Reliable correlation sum analysis is possible only for more or less stationary time series, cf. [4]. Meanwhile, HRV signal is highly non-stationary, as is evidenced by the multifractal structure of its long-time dynamics [18]. The most stationary period in the heart rate dynamics is the sleeping time. This is why we studied only the nocturnal part of the HRV records. The scaling exponent was determined as the slope of the correlation sum C 2 (r) in log-log plot by performing root-mean-square fit for the almost linear part (at small values of r) of the curve, see Fig. 3. Note that the leftmost horizontal part of the curve is due to the limited resolving power (6 ms) of the medical equipment: if two NN-intervals differ less than 6 ms, they are recorded to be of the same length. The scaling exponents ranged from D = 4.2 to D = 5.1 and were almost uncorrelated with the diagnoses (see Table 2). Further we generated two surrogate time-series with Gaussian noise: (i) plain Gaussian noise added to a mean

4 p,% IHD SND VES PCI RR FSK Healthy 89.4 21.9 3.5 18.4 2.4 71.5 IHD 34.1 12.0 17.6 7.1 69.4 SND 66.8 52.9 45.7 54.4 VES 73.0 67.6 25.2 PCI 95.7 26.7 RR 15.9 TABLE III: p-values of the Student test for the seven group of patients. Abbreviations are explained in Table 1. rate (see Fig. 4c); (ii) time-series with variable mean rate and modulated noise, generated according to the formula = a + b sin(fn) + cg(n) 1.1 + sin(fn), (4) see Fig. 4b. Here, denotes the duration of n-th interval; g(n) is a random normally distributed value with zero mean and standard deviation equal to 1. The term b sin(fn) models the variability of the mean heart rate due to physiological processes (physical activity, blood pressure oscillations, etc.). The term 1.1 + sin(fn) reflects the empirical observation that the short-time variability of heart rhythm increases together with the mean heart beat interval. Note that both the square-root and sinusoidal dependances are rather arbitrary, the model is not sensitive neither with respect to the particular functional dependencies nor with respect to the modulation frequency f. The numerical values of these parameters have been chosen as follows: a = 500 ms, b = 110 ms, f = 0.005, c = 3.5 ms; the values of were rounded to the nearest multiple of 6 ms (the resolving power ). For a Gaussian signal, the correlation dimension is infinite and the scaling exponent should be equal to the embedding dimension m = 6. This is exactly what is observed for plain unmodulated Gaussian time-series, see Fig. 5. However, for the noise of modulated amplitude, the finite size effects are significant. Depending on the parameters b and c, the correlation sum in Fig. 6 can be almost indistinguishable from the ones of real patients, see Fig. 4. The scaling exponent D of such time-series FIG. 3: Heart beat intervals (in arbitrary units) are plotted versus the beaumber: (a) a real patient; (b) surrogate data (modulated Gaussian noise); (c) plain Gaussian noise added to a constant heart rate. a) b) c) n 0 ln C 2 (r) -5-10 -15-20 D = 5.9 D = 4.9 0.00 1.82 3.64 5.46 a real patient surrogate data gaussian noise ln r 7.28 FIG. 4: Correlation sums of a healthy patient, a plain Gaussian signal, and a modulated Gaussian signal in logarithmic plot. Embedding dimensionality m = 6. depends on the amplitude of the Gaussian noise and on the resolving power (which, unlike in the case of real apparatus, was also freely adjustable). By adjusting the above defined parameters b, c, and the resolving power, we were able to obtain the values ranging from D = 4 to D = 6. In conclusion, comparative analysis of real and surrogate data confirmed that the scaling behaviour of the correlation sum and finite values of the formally calculated correlation dimension D are the result of the interplay of the following factors: finite resolution of the recording equipment (which leads to finite-size effects), a significant level of long-time variability (the dynamical range of the mean heart rate exceeds the typical level of shorttime variability), the fact that the amplitude of shorttime variability is a decreasing function of the mean heart rate. The value of the scaling exponent is mostly defined by the dynamics of the short-time variability and resolving power of the recording apparatus; it depends also on on the maximal embedding dimensionality. Therefore, it can be used as a certain measure of short-time variability of the signal (however, in order to obtain comparable values, time-resolution and record length have to be kept constant). The diagnostic and/or prognostic value of this measure is possible, but found to be non-significant for our patient groups (see Table 2). We have also shown that the above drawn conclusion remains valid even in these cases, when certain patterns (satellite clouds) can be observed in time delay coordinates of heart rhythm (see Fig. 3). These patterns are typically due to the respiratory sinus arrhythmia and mode coupling between respiration and heart rhythm without any relation to the (possibly) derministic dynamics inside the heart. Finally, we have devised a simple method of detecting the presence of this mode coupling, based on fluctuation function (2).

5 The support of Estonian Science Foundation grant No. 4151 is acknowledged. The authors are grateful to Prof. J. Engelbrecht for useful discussions. [1] L. Glass, M.R. Guevara, A. Shrier, and R. Perez, Physica D, 7, 89(1983). [2] B. West, A. Goldberger, G. Rooner, and V. Bhargava, Physica D 17, 198(1985). [3] A. Babloyantz, A. Destexhe, Biol. Cybern. 58, 203(1988). [4] H. Kantz, T. Schreiber, Chaos 5(1), 143(1995). [5] J.K. Kanters, N.H. Holstein-Rathlou, and E. Agner, J. Cardivasc. Electrophys. 5, 591(1994). [6] A. Bezerianos, T. Bountis, G. Papaioannou, and P. Polydoropoulus, Chaos 5, 95, (1995). [7] R.M. Berne and N.M. Levy, Cardiovascular Physiology. Eighth edition. Mosby, New York 2001. [8] D.L. Kaplan and M. Talajic, Chaos 1, 251(1991). [9] M. Rosenblum and J. Kurths, Physica A 215, 439(1995). [10] H. Kantz and T. Schreiber, Nonlinear Time Series Analysis, Cambridge Univ. Press, Cambridge 1997. [11] P. Grassberger and J. Procaccia, Physica D 9, 189(1983). [12] J.B. Bassingthwaighte, L.S. Liebovitch, and B.J. West, Fractal Physiology, Oxford Univ. Press, New York 1994. [13] C. Schäfer, M.G. Rosenblum, J. Kurths, and H.H. Abel, Nature 392, 240(1998) [14] N.B. Janson, A.G. Balanov, V.S. Anishchenko, and P.V.E. McClintock, Phys. Rev. Lett. 86(9), 1749(2001). [15] L. Smith, Phys. Lett. A 133, 283(1988). [16] R. Govindan, K. Narayanan, and M. Gopinathan, Chaos 8, 495(1998). [17] S. Guzzetti, M.G. Signorini, C. Cogliati, S. Mezzetti, A. Porta, S. Cerutti, and A. Malliani Cardiovasc. Res. 31, 441(1996). [18] P.Ch. Ivanov, M.G. Rosenblum, L.A.N. Amaral, Z. Struzik, S. Havlin, A.L. Goldberger, and H.E. Stanley, Nature 399, 461(1999).