Conductimetric Titration and Gravimetric Determination of a Precipitate

Similar documents
Conductimetric Titration and Gravimetric Determination of a Precipitate

Conductometric Titration & Gravimetric Determination of a Precipitate

Acid-Base Titration. Sample

Using Conductivity to Find an Equivalence Point

Acid-Base Titration. Evaluation copy

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Acid-Base Titration. Computer OBJECTIVES

Microscale Acid-Base Titration

Acid-Base Titration. Volume NaOH (ml) Figure 1

Standardization of a Primary Standard & Determination of Concentration by Acid-Base Titration

Determining the K sp of Calcium Hydroxide

ACID-BASE TITRATION (MICROSCALE)

Determining the Concentration of a Solution: Beer s Law

Experimental Procedure

Chemistry with Mr. Faucher. Acid-Base Titration

Determining the Concentration of a Solution: Beer s Law

Microscale Acid-Base Titration

AP Chemistry Lab #5- Synthesis and Analysis of Alum (Big Idea 1 & 2)

The Synthesis and Analysis of Aspirin

HESS S LAW: ADDITIVITY OF HEATS OF REACTION

ELECTRICAL CONDUCTION IN SOLUTIONS

H 2 CO 3 (aq) HNO 2 (aq) + HNO 3 (aq)

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

Additivity of Heats of Reaction: Hess s Law

Evaluation copy. The Molar Mass of a Volatile Liquid. computer OBJECTIVES MATERIALS

Rate Law Determination of the Crystal Violet Reaction. Evaluation copy

What Causes the Seasons?

Alkalinity. LabQuest INTRODUCTION

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

6 Acid Base Titration

The Determination of an Equilibrium Constant

Titration of a Cola Product INSTRUCTOR RESOURCES

Additivity of Heats of Reaction: Hess s Law

PRELIMINARY ACTIVITY FOR

Ascorbic Acid Titration of Vitamin C Tablets

for a Weak Acid 1-ring stand stir plate and stir bar ph Probe ml burette 1-50 ml and ml beaker Drop counter ph 7.00 buffer 0.

INSTRUCTOR RESOURCES

Acids and Bases. Figure 1. Logger Pro or graph paper

Related concepts Electrolyte, electrical conductance, specific conductance, ion mobility, ion conductivity, conductometry, volumetry.

Experiment 7: ACID-BASE TITRATION: STANDARDIZATION OF A SOLUTION

experiment7 Explaining the difference between analyte and standard solutions. Know the definition of equivalence point.

THE IDENTIFICATION OF A SOLID ORGANIC ACID

How Can We Determine the Actual Percentage of H 2 O 2 in a Drugstore Bottle of Hydrogen Peroxide?

Synthesis of Benzoic Acid

Chemical Equilibrium: Finding a Constant, Kc

Apply the ideal gas law (PV = nrt) to experimentally determine the number of moles of carbon dioxide gas generated

pka AND MOLAR MASS OF A WEAK ACID

Shown below is a sample titration curve for a diprotic acid. Note the two equivalence points.

Lab 5 Enthalpy of Solution Formation

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

Evaluation copy. Acids and Bases. computer OBJECTIVES MATERIALS

INTRODUCTION TO ACIDS, BASES AND TITRATION

Chemical Equilibrium: Finding a Constant, Kc

Use quantitative and qualitative analyses to identify the powder in Mr. Orlow s car.

Part II. Cu(OH)2(s) CuO(s)

Acids and Bases. Figure 1

TITRATION CURVES INTRODUCTION. Read and/or review Sections 4.10 and 16.7 in your textbook.

The Effect of Alcohol on Biological Membranes

LABORATORY INVESTIGATION

Lifetime Measurement

Falling Objects. LabQuest OBJECTIVES MATERIALS PROCEDURE

ph Titration Curves You will need about 10 ml of ~6M NaOH solution and about 40 ml of each acid solution and about 1.5 grams of KHP.

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

Determination of the K a of a Weak Acid and the K b of a Weak Base from ph Measurements

Ka of Unknown Acid In this experiment you will determine the Ka of an unknown acid by titration with the sodium hydroxide.

Experiment 7. Determining the Rate Law and Activation Energy for the Reaction of Crystal Violet with Hydroxide Ion

Heat of Combustion: Magnesium

The Decomposition of Hydrogen Peroxide. Evaluation copy

The Determination of an Equilibrium Constant

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

Titration of Acids and Bases

Experiment 2: Reaction Stoichiometry by Thermometric Titration

The Determination of an Equilibrium Constant

Chemistry 3202 Lab 6 Hess s Law 1

# 12 ph-titration of Strong Acids with Strong Bases

Titration 3: NH 3 Titrated with HCl

To use calorimetry results to calculate the specific heat of an unknown metal. To determine heat of reaction ( H) from calorimetry measurements.

The Determination of an Equilibrium Constant

EXPERIMENT 15. USING CONDUCTIVITY TO LOOK AT SOLUTIONS: DO WE HAVE CHARGED IONS OR NEUTRAL MOLECULES? rev 7/09

17 Isolation and Epoxidation of a Natural Product: R-(+)-Limonene

TRATION: ANALYSIS OF VINE

Scientific Observations and Reaction Stoichiometry: The Qualitative Analysis and Chemical Reactivity of Five White Powders

Titration of a strong acid with a strong base with Cobra4

Chemical Reactions: The Copper Cycle

Thermodynamics and the Solubility of Sodium Tetraborate Decahydrate

Measuring Enthalpy Changes and Gas Laws

Where IS North? LabQuest OBJECTIVES

EXPERIMENT 8 Determining K sp

1iI1E. The Determination of 0 an Equilibrium Constant [LU. Computer

Chemistry 151 Last Updated Dec Lab 8: Precipitation Reactions and Limiting Reagents

Determining the Enthalpy of a Chemical Reaction

Chemistry 143 Acid Base Titration Dr. Caddell. Titrating Acid

Lab 12 Pressure-Temperature Relationship in Gases

NaOH (aq) + HCl (aq) NaCl (aq) + H 2 O (l)

Titration with an Acid and a Base

What Causes the Seasons?

2. Synthesis of Aspirin

ph Measurement and its Applications

Acid Rain. Evaluation copy

Transcription:

Conductimetric Titration and Gravimetric Determination of a Precipitate Handheld 16 In this experiment, you will monitor conductivity during the reaction between sulfuric acid, H 2 SO 4, and barium hydroxide, Ba(OH) 2, in order to determine the equivalence point. From this information, you can find the concentration of the Ba(OH) 2 solution. The reaction between sulfuric acid and barium hydroxide yields an insoluble product, barium sulfate, and water, as shown in the reaction equation below. Ba 2+ (aq) + 2 OH (aq) + 2 H + (aq) + SO 4 2 (aq) BaSO 4 (s) + H 2 O(l) In this reaction, the total number of dissociated ions in solution is reduced dramatically during the reaction as a precipitate is formed. As 0.100 M H 2 SO 4 is slowly added to Ba(OH) 2 of unknown concentration, changes in the conductivity of the solution will be monitored using a Conductivity Probe. When the probe is placed in a solution that contains ions, and thus has the ability to conduct electricity, an electrical circuit is completed across the electrodes that are located on either side of the hole near the bottom of the probe body. This results in a conductivity value that can be read by the interface. The unit of conductivity used in this experiment is the microsiemens per cm, or µs/cm. In addition, you will capture the precipitate, and measure its mass. You will have two methods, therefore, of calculating the molar concentration of a barium hydroxide solution that is titrated with a sulfuric acid solution of known concentration. OBJECTIVES In this experiment, you will Measure the conductivity of the reaction between sulfuric acid and barium hydroxide. Use conductivity values as a means of determining the equivalence point of the reaction. Measure the mass of a product of the reaction as a means of determining the equivalence point of the reaction gravimetrically. Calculate the molar concentration of a barium hydroxide solution. Figure 1 Advanced Chemistry with Vernier 2007 Vernier Software & Technology 16-1

Handheld 16 CHOOSING A METHOD If you choose Method 1, you will conduct the titration in a conventional manner. You will deliver volumes of H 2 SO 4 titrant from a buret. After titrant is added, and conductivity values have stabilized, you will manually enter the buret reading to store conductivity-volume data. If you choose Method 2, you will use a Vernier Drop Counter to take volume readings. H 2 SO 4 titrant is delivered drop by drop from the reagent reservoir through the Drop Counter slot. After the drop reacts with the reagent in the beaker, the volume of the drop is calculated, and a conductivity-volume data pair is stored. MATERIALS Materials for both Method 1 (buret) and Method 2 (Drop Counter) LabPro interface magnetic stirrer handheld device stirring bar or Microstirrer Vernier Conductivity Probe two ring stands barium hydroxide, Ba(OH) 2, solution ring stand ring 0.100 M sulfuric acid, H 2 SO 4, solution utility clamp distilled water filter paper two 250 ml beakers filter funnel 50 ml graduated cylinder balance, ±0.01 gram accuracy (or better) 10 ml pipet and pipet bulb or pump drying oven (optional) Materials required only for Method 1 (buret) 50 ml buret buret clamp Materials required only for Method 2 (Drop Counter) Vernier Drop Counter 100 ml beaker 60 ml reagent reservoir 10 ml graduated cylinder METHOD 1 Measuring Volume Using a Buret 1. Obtain and wear goggles. 2. Use a pipet bulb (or pipet pump) to transfer 10.0 ml of the Ba(OH) 2 solution into a 250 ml beaker. Add 50 ml of distilled water. CAUTION: The barium hydroxide solution is caustic. Avoid spilling it on your skin or clothing. 3. Place the beaker on a magnetic stirrer and add a stirring bar. If no magnetic stirrer is available, you will stir with a stirring rod during the titration. 4. Connect a Conductivity Probe to Channel 1 of the LabPro interface. Connect the interface to the handheld using the proper cable. Set the selector switch on the Conductivity Probe to the 0-20000 µs/cm range. 5. Measure out approximately 60 ml of 0.100 M H 2 SO 4 into a 250-mL beaker. Record the precise H 2 SO 4 concentration in your data table. CAUTION: H 2 SO 4 is a strong acid, and should be handled with care. 16-2 Advanced Chemistry with Vernier

Conductimetric Titration and Gravimetric Determination of a Precipitate 6. Set up a ring stand, buret clamp, and 50.0 ml buret to conduct the titration (see Figure 1). Rinse and fill the buret with the H 2 SO 4 solution. 7. Use a utility clamp to connect the Conductivity Probe to a ring stand, as shown in Figure 1. Position the Conductivity Probe in the Ba(OH) 2 solution and adjust its position so that it is not struck by the stirring bar. 8. Set up the handheld and interface for the Conductivity Probe. a. Turn on the handheld. Tap the Data Pro icon on the Applications screen. Choose New from the Data Pro menu or tap to reset the program. b. On the Main screen, tap. If the handheld displays CONDUCT(MICS) in CH 1, proceed directly to Step 9. If it does not, continue with this step to set up your sensor manually. c. Tap to select Channel 1. d. Choose CONDUCT 20000(MICS) from the list of sensors. 9. Set up the data collection mode. a. On the Setup screen, tap, then choose Events with Entry. b. For the Event Label, enter Volume as the Name and ml as the Unit. You can enter this information using the onscreen keyboard (tap abc ), or by using the Graffiti writing area. c. Tap twice to return to the Main screen. 10. Tap to begin data collection. Conduct the titration carefully, as described below. a. Before you have added any H 2 SO 4 solution, tap. Enter 0, the volume in ml, using the numerical keyboard displayed on the screen. Tap to save this data pair. b. Add 1.0 ml of 0.100 M H 2 SO 4 to the beaker. When the conductivity value stabilizes, tap. Enter 1 as the volume in drops and then tap. c. Continue adding 1.0-mL increments of H 2 SO 4 solution, each time entering the buret reading, until the conductivity has dropped below 100 µs/cm. d. After the conductivity has dropped below 100 µs/cm, add one 0.5-mL increment and enter the buret reading. e. After this, use 2-drop increments (~0.1 ml) until the minimum conductivity has been reached at the equivalence point. Enter the volume after each 2-drop addition. When you have passed the equivalence point, continue using 2-drop increments until the conductivity is greater than 50 µs/cm again. f. Now use 1.0-mL increments until the conductivity reaches about 1000 µs/cm, or 15 ml of H 2 SO 4 solution have been added, whichever comes first. 11. Tap when you have finished collecting data, then tap to view a graph of conductivity vs. volume. 12. Examine the data on the displayed graph to find the equivalence point; that is, the volume when the conductivity value reaches a minimum. To examine the data pairs on the displayed graph, tap or any data point. Record the H 2 SO 4 volume, at the point of minimum conductivity, in your data table. 13. Filter and measure the mass of the barium sulfate precipitate. a. Use a hot plate to warm the beaker of mixture containing the BaSO 4 precipitate. Warm the solution to near boiling for about five minutes to help flocculate the particles. Advanced Chemistry with Vernier 16-3

Handheld 16 b. While the mixture is heating, set up a ring stand and ring for the filter funnel. Measure and record the mass of a piece of fine-grade filter paper and set the paper in the funnel. c. Allow the mixture to cool, and then filter it. The liquid need not be at room temperature to be filtered. Wash the precipitate out of the beaker with small amounts of distilled water, if necessary. d. Dry the precipitate and filter paper in a drying oven for at least 15 minutes. e. Cool the precipitate and filter paper to near room temperature. Measure and record the mass of the filter paper and precipitate. f. Heat the precipitate again for five minutes, cool the precipitate, and weigh it. g. Heat the precipitate a third time, for five more minutes, cool the precipitate and weigh it. If the masses of filter paper and precipitate are the same in the final two weighings, dispose of the filter paper as directed. If the final two weighings are not the same, check with your instructor to see if more drying time is needed. 14. Rinse the Conductivity Probe with distilled water in preparation for the second titration. 15. Print the graph directly from your handheld, if possible. Alternately, transfer the data to a computer, using Logger Pro software. 16. Repeat the necessary steps to conduct a second titration. Conduct a third trial, if needed. Record the results in the data table. METHOD 2 Measuring Volume Using a Drop Counter 1. Obtain and wear goggles. 2. Use a pipet bulb (or pipet pump) to transfer 10.0 ml of the Ba(OH) 2 solution into a 250 ml beaker. Add 50 ml of distilled water. CAUTION: The barium hydroxide solution is caustic. Avoid spilling it on your skin or clothing. Figure 2 3. Connect a Conductivity Probe to Channel 1 of the LabPro interface. Lower the Drop Counter onto a ring stand and plug it into the DIG/SONIC 1 port of the interface (see Figure 2). 16-4 Advanced Chemistry with Vernier

Conductimetric Titration and Gravimetric Determination of a Precipitate Connect the interface to the handheld using the proper cable. Set the selector switch on the Conductivity Probe to the 0-20000 µs/cm range. 4. Obtain the plastic 60 ml reagent reservoir. Close both valves by turning the handles to a horizontal position. Follow the steps below to set up the reagent reservoir for the titration. a. Rinse the reagent reservoir with a few ml of the 0.100 M H 2 SO 4 solution and pour the H 2 SO 4 into an empty 250 ml beaker. CAUTION: H 2 SO 4 is a strong acid, and should be handled with care. b. Use a utility clamp to attach the reservoir to the ring stand. c. Fill the reagent reservoir with slightly more than 60 ml of the 0.100 M H 2 SO 4 solution. d. Place the 250 ml beaker, which contains the rinse H 2 SO 4, beneath the tip of the reservoir. e. Drain a small amount of the H 2 SO 4 solution into the 250 ml beaker so that it fills the reservoir s tip. To do this, turn both valve handles to the vertical position for a moment, then turn them both back to horizontal. f. Discard the drained H 2 SO 4 solution in the 250 ml beaker as directed. 5. Set up the handheld and interface for the Conductivity Probe. a. Turn on the handheld. Tap the Data Pro icon on the Applications screen. Choose New from the Data Pro menu or tap to reset the program. b. On the Main screen, tap. If the handheld displays CONDUCT(MICS) in CH 1, proceed directly to Step 6. If it does not, continue with this step to set up your sensor manually. c. Tap to select Channel 1. d. Press the Scroll buttons on the handheld to scroll through the list of sensors. e. Choose CONDUCT 20000(MICS) from the list of sensors. 6. Set up the handheld and interface for the Drop Counter. a. If the handheld displays VOL(mL) in DIG/SON 1, proceed directly to Step 7. If it does not, continue with this step to set up your sensor manually. b. Tap to select the DIG/SONIC 1 port. c. Choose DROP COUNTER from the list of sensors. 7. Calibrate the Drop Counter so that a precise volume of titrant is recorded in units of milliliters. a. On the Setup screen, tap. b. On the Calibration screen, tap CH1: ph and select DIG/SON 1: VOL(mL) to calibrate the Drop Counter. If you have previously calibrated the drop size of your reagent reservoir and want to continue with the same drop size, tap. Enter the value for New drops/ml (using the onscreen keyboard (tap 123 ) or using the Graffiti writing area) and tap. Tap twice to return to the Main screen and proceed directly to Step 8. If you want to perform a new calibration, tap, and continue with this step. c. Place a 10 ml graduated cylinder directly below the slot on the Drop Counter, lining it up with the tip of the reagent reservoir. d. Open the bottom valve on the reagent reservoir (vertical). Keep the top valve closed (horizontal). Advanced Chemistry with Vernier 16-5

Handheld 16 e. Slowly open the top valve of the reagent reservoir so that drops are released at a slow rate (~1 drop every two seconds). You should see the drops being counted on the screen. f. When the volume of H 2 SO 4 solution in the graduated cylinder is between 9 and 10 ml, close the bottom valve of the reagent reservoir. g. Enter the precise volume of H 2 SO 4 using the onscreen keyboard (tap 123 ) or using the Graffiti writing area. Tap and then tap. Record the number of drops/ml displayed on the screen for possible future use. h. Tap twice to return to the Main screen. Discard the H 2 SO 4 solution in the graduated cylinder as indicated by your instructor and set the graduated cylinder aside. 8. Assemble the apparatus. a. Place the magnetic stirrer on the base of the ring stand. b. Insert the Conductivity Probe through the large hole in the Drop Counter. c. Attach the Microstirrer to the bottom of the ph Sensor. Rotate the paddle wheel of the Microstirrer, and make sure that it does not touch the bottom of the Conductivity Probe. d. Adjust the positions of the Drop Counter and reagent reservoir so they are both lined up with the center of the magnetic stirrer. e. Lift up the Conductivity Probe, and slide the beaker containing the Ba(OH) 2 solution onto the magnetic stirrer. Lower the Conductivity Probe into the beaker. f. Adjust the position of the Drop Counter so that the Microstirrer on the Conductivity Probe is just touching the bottom of the beaker. g. Adjust the reagent reservoir so its tip is just above the Drop Counter slot. h. Turn on the magnetic stirrer so that the Microstirrer is stirring at a fast rate. 9. You are now ready to perform the titration. a. Tap on the Main screen. No data will be collected until the first drop goes through the Drop Counter slot. b. Fully open the bottom valve. The top valve should still be adjusted so drops are released at a rate of about 1 drop every 2 seconds. When the first drop passes through the Drop Counter slot, check the graph to see that the first data pair was recorded. c. Observe that the conductivity readings decrease gradually. Continue watching your graph to see when the conductivity begins to increase; this will be the equivalence point of the reaction. When this increase in conductivity occurs, let the titration proceed for several more milliliters of titrant. d. Tap, and then tap to view a graph of conductivity vs. volume. e. Turn the bottom valve of the reagent reservoir to a closed (horizontal) position. 10. Examine the data on the displayed graph to find the equivalence point; that is, the volume when the conductivity value reaches a minimum. To examine the data pairs on the displayed graph, tap or any data point. Record the H 2 SO 4 volume, at the point of minimum conductivity, in your data table. 11. Filter and measure the mass of the barium sulfate precipitate. a. Use a hot plate to warm the beaker of mixture containing the BaSO 4 precipitate. Warm the solution to near boiling for about five minutes to help flocculate the particles. b. While the mixture is heating, set up a ring stand and ring for the filter funnel. Measure and record the mass of a piece of fine-grade filter paper and set the paper in the funnel. 16-6 Advanced Chemistry with Vernier

Conductimetric Titration and Gravimetric Determination of a Precipitate c. Allow the mixture to cool, and then filter it. The liquid need not be at room temperature to be filtered. Wash the precipitate out of the beaker with small amounts of distilled water, if necessary. d. Dry the precipitate and filter paper in a drying oven for at least 15 minutes. e. Cool the precipitate and filter paper to near room temperature. Measure and record the mass of the filter paper/precipitate. f. Heat the precipitate again for five minutes, cool the precipitate, and weigh it. g. Heat the precipitate a third time, for five more minutes, cool the precipitate and weigh it. If the masses of filter paper/precipitate are the same in the final two weighings, dispose of the filter paper as directed. If the final two weighings are not the same, check with your instructor to see if more drying time is needed. 12. Rinse the Conductivity Probe with distilled water in preparation for the second titration. 13. Print the graph directly from your handheld, if possible. Alternately, transfer the data to a computer, using Logger Pro software. 14. Repeat the necessary steps to conduct a second titration. Conduct a third trial, if needed. Record the results in the data table. Print the graph of your final trial. DATA TABLE Equivalence point (ml) Trial 1 Trial 2 Trial 3 Mass of filter paper + precipitate (g) Mass of filter paper (g) Mass of precipitate (g) Molarity of H 2 SO 4 (M) Advanced Chemistry with Vernier 16-7

Handheld 16 DATA ANALYSIS 1. Use the titration results to calculate the moles of H 2 SO 4 that were used to reach the equivalence point in each trial. 2. Use your titration results to calculate the molar concentration (molarity) of the Ba(OH) 2 solution using the molar amount of H 2 SO 4 used in each trial. 3. Convert the mass of the barium sulfate precipitate, formed in each trial, to moles. 4. Use the moles of BaSO 4 from 3 above to calculate the molarity of the Ba(OH) 2 solution. 5. Compare the results of your calculations from 2 and 4 above with the actual molarity of the Ba(OH) 2 solution. Which method of analysis, equivalence point or gravimetric determination, was more accurate in your experiment? Why? 16-8 Advanced Chemistry with Vernier

Experiment 16 TEACHER INFORMATION Conductimetric Titration and Gravimetric Determination of a Precipitate 1. This experiment conforms to the guidelines for the 16 th laboratory experiment listed in the College Board AP Chemistry guide (the Acorn book). 2. The student pages with complete instructions for data-collection using LabQuest App, Logger Pro (computers), EasyData or DataMate (calculators), DataPro (Palm handhelds), and a generic version can be found on the CD that accompanies this book. See Appendix A for more information. 3. Prepare 500 ml of 0.100 M sulfuric acid solution by adding 2.75 ml of concentrated H 2 SO 4 solution to about 400 ml of distilled water and then adding distilled water to make a total volume of 500 ml. 4. Prepare 500 ml of the unknown barium hydroxide solution to an approximate concentration of 0.1 M by dissolving 16.67 g of Ba(OH) 2 8H 2 O in 500 ml of distilled water. The solution will have a molarity that is significantly less than 0.1 M and the liquid will contain BaCO 3 precipitate from the dissolved CO 2 in the mix water. Filter the solution, to remove the carbonate impurities, before your students conduct this experiment. 5. In filtering the precipitate, your students should use the finest grain paper available. Alternately, the students can use a Gooch filter apparatus or a Büchner funnel with vacuum filtering. 6. If your students use a magnetic stirrer, make sure that they do not stir the mixture too vigorously. Rapid stirring may affect the conductivity readings and produce some anomalous data points during the titration. 7. Heating the reaction solution for 5 10 minutes before filtering off the precipitate will flocculate the barium sulfate and make it easier to collect the solid on filter paper. 8. Provide a container into which the students will dispose of their BaSO 4 and waste liquids. Please follow safe practices in handling and disposing of waste from this experiment. 9. The stored calibration for the Conductivity Probe works well for this experiment. 10. For best results, instruct your students to perform a new calibration on their Drop Counters. If time does not permit a new calibration, a substitute value of 28 drops/ml may be used. This value will provide good results. If students will not be calibrating their Drop Counters, instruct them follow the procedure for manually entering a calibration value and to enter a value of 28 for the drops/ml ratio. 11. If you are using a calculator and EasyData, there are several different combinations of equipment that will work for collecting conductivity data. The most common method, which works for both the TI-83 Plus and TI-84 Plus families of calculators, is to use a Conductivity Probe connected to a LabPro or a CBL 2. This is the equipment that must be used if you are collecting data with a calculator and a Drop Counter (Method 2 of the Procedure). Advanced Chemistry with Vernier 16-1 T

Experiment 16 The other combination of equipment, which uses the USB port on a TI-84 Plus calculator, is to collect data with a Conductivity Probe connected to an EasyLink. The EasyLink cannot be used with a Drop Counter because the Drop Counter is not supported by the EasyLink. For more information on EasyLink refer to Appendix H. HAZARD ALERTS Barium hydroxide: Toxic by ingestion. Hazard code: C Somewhat hazardous. Sulfuric acid: Severely corrosive to eyes, skin and other tissue; considerable heat of dilution with water; mixing with water may cause spraying and spattering. Solutions might best be made by immersing the mixing vessel in an ice bath. Extremely hazardous in contact with finely divided materials, carbides, chlorates, nitrates, and other combustible materials. Hazard code: A Extremely hazardous. The hazard information reference is: Flinn Scientific, Inc., Chemical and Biological Catalog Reference Manual, P.O. Box 219, Batavia, IL 60510, (800) 452-1261, www.flinnsci.com. ANSWERS TO THE DATA ANALYSIS QUESTIONS Answers have been removed from the online versions of Vernier curriculum material in order to prevent inappropriate student use. Graphs and data tables have also been obscured. Full answers and sample data are available in the print versions of these labs. SAMPLE DATA Equivalence point (ml) Mass of filter paper + precipitate (g) Mass of filter paper (g) Mass of precipitate (g) x.xx x.xx x.xx x.xx 16-2 T Advanced Chemistry with Vernier

Conductimetric Titration and Gravimetric Determination of a Precipitate SAMPLE GRAPH Plot of conductivity vs. volume of sulfuric acid Advanced Chemistry with Vernier 16-3 T