E v a l u a t i o n C e r t i f i c a t e

Similar documents
E C t y p e - e x a m i n a t i o n C e r t i f i c a t e

A compression load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Molen or Precia Molen.

9.1 Compatibility of modules for nonautomatic weighing instruments (NAWIs) Common requirements

NEW VSL Conditioning plate!

CALIBRATION CERTIFICATE # 503

Evaluating New Generation Vibrating Tube Sensor for Density Measurement under Process Conditions

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018

Linearity of Coriolis Flowmeters at Full Scale Value. Dr. Jesús Aguilera - Endress + Hauser Paul Ceglia - Endress + Hauser

Fine Tuning Coriolis Flow Meter Calibrations Utilizing Piece- Wise Linearization

+ + ( indicator ) + (display, printer, memory)

KNOWLEDGE

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES

Guidelines for the Selection and Operation of Provers with Micro Motion ELITE Coriolis Flow Meters

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

Certification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60

Traceable Mass Determination and Uncertainty Calculation

Infrared Thermometer Calibration A Complete Guide

Integrated Circuits Thermal Test Method Environment Conditions - Natural Convection (Still Air)

INTERNATIONAL STANDARD

Project PAJ2 Dynamic Performance of Adhesively Bonded Joints. Report No. 3 August Proposed Draft for the Revision of ISO

Sonic Anemometer Classification

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

Relative pressure transmitter type 520

Load Cell Approval Field and Laboratory Evaluation Manual

ISO INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Addendum to ARI Standard , Air Terminals September 2002

Determination of particle size distribution Single particle light interaction methods. Part 4:

Uncertainties associated with the use of a sound level meter

ISO INTERNATIONAL STANDARD

Understanding the Uncertainty when Using a Type Coefficient for Temperature Corrections of a Coriolis meter. Dean M. Standiford Emerson-Micromotion

ENERGY DISTRIBUTION ANALYSIS IN A LOW HEAD FRANCIS TURBINE DURING THERMODYNAMIC EFFICIENCY MEASUREMENTS

KNOWLEDGE. Allow Smart Meter Verification to Reduce your Proving and Proof-Test Costs. Abstract. Introduction

Installation guide 862 MIT / MIR

OIML R RECOMMENDATION. Edition 2006 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Instruments for measuring the areas of leathers

CNG measuring systems for vehicles

INTERNATIONAL OIML R 15 RECOMMENDATION

ISO INTERNATIONAL STANDARD. Paints and varnishes Determination of density Part 3: Oscillation method

OIML R 50-3 RECOMMENDATION. Edition 2014 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Test report CVN Project number Page 2 of 2

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

OIML R 141 RECOMMENDATION. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Manual of Petroleum Measurement Standards Chapter 5 Metering

INTERNATIONAL STANDARD

OIML D 28 DOCUMENT. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Conventional value of the result of weighing in air

1 Client The request to draft this report was made by DELTA Light & Optics, Venlighedsvej 4, DK-2970 Hørsholm, Denmark.

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0

Measurement of fluid flow in closed conduits

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

MODELLING OF VIBRATION WITH ABSORBER

Marine Heat Flow Measurements Information Brochure

Custody Transfer Measurement and Calibration Round Robin Testing for Natural Gas with Coriolis Meters

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

WIESON TECHNOLOGIES CO., LTD.

Calibration of Temperature Block Calibrators

PRELIMINARY DRAFT INDIAN STANDARD METHOD FOR CALIBRATION AND CLASSIFICATION OF TORQUE MEASURING DEVICES INCLUDING TORQUE WRENCH TESTER

Typical pressure measurement uncertainty defined by an FPG8601 Force Balanced Piston Gauge

ANSI/AHRI Standard (Formerly ARI Standard ) 2006 Standard for Performance Rating of Desuperheater/Water Heaters

English - Or. English NUCLEAR ENERGY AGENCY STEERING COMMITTEE FOR NUCLEAR ENERGY

INTERNATIONAL STANDARD

Pressure Measurement Single-range transmitters for general applications

OA03 UNCERTAINTY OF MEASUREMENT IN CHEMICAL TESTING IN ACCORDANCE WITH THE STANDARD SIST EN ISO/IEC Table of contents

POWER UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES

ORGANISATION INTERNATIONALE DE MÉTROLOGIE LÉGALE INTERNATIONAL RECOMMENDATION

POWER QUALITY MEASUREMENT PROCEDURE. Version 4 October Power-Quality-Oct-2009-Version-4.doc Page 1 / 12

Metallic materials Knoop hardness test. Part 1: Test method. Matériaux métalliques Essai de dureté Knoop Partie 1: Méthode d'essai

The Fundamentals of Moisture Calibration

REPORT ON API 21.1 EGM STANDARD Brent E. Berry ABB-Totalflow

Standard Practices for Air Speed Calibration Testing

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Euramet project 1075 Bilateral comparison

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

ISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2

Paper # # Verification of Coriolis Flow

Review of Anemometer Calibration Standards

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Laboratory Evaluation Report for: Dielectric Pipe Unions

Verification for Non-Automatic Weighing Instruments (NAWI)

IS INTERNATIONAL STANDARD. Natural gas - Guidelines to traceability in analysis

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM

ALASTAIR MCLACHLAN Applications Cameron

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

ED 701 General Industry Pressure Transmitter

APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

CERTIFICATE OF CALIBRATION

ISO INTERNATIONAL STANDARD. Test code for machine tools Part 5: Determination of the noise emission

Surface-mounting Thermostats ATH Type Series

Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

Advisory Circular. U.S. Department of Transportation Federal Aviation Administration

ISO 3741 INTERNATIONAL STANDARD

METHODS FOR CERTIFYING MEASUREMENT EQUIPMENT. Scott Crone

DEVELOPMENT, CONSTRUCTION, DELIVERY AND WARRANTY OF A DEVICE ABLE TO DETERMINE BOUNCE PARAMETERS OF A TABLE TENNIS BALL ON A TABLE SURFACE

Book 14 Edition 1.1 March Socketable Flat LED Module and LED Light Engine

Transcription:

E v a l u a t i o n C e r t i f i c a t e Page 1 of 1 Issued by In accordance with Producer WELMEC guide 8.8 General and Administrative Aspects of the Voluntary System of Modular Evaluation of Measuring instruments under the MID. OIML R117-1 Edition 2007 (E) Dynamic measuring systems for liquids other than water. Emerson Process Management Flow B.V. Neonstraat 1 6718 WX Ede The Netherlands Measuring instrument A Measurement sensor (Coriolis sensor), intended to be used as a part of a measuring instrument. Manufacturer Type : : Micro Motion Fxxx, see paragraph 1.2 of Description Destined for the measurement of : Liquid petroleum and related products, potable liquids, liquid chemicals and liquefied gasses under pressure with densities between 450 and 1100 kg/m 3 Q min Q max : see paragraph 1.2 of Description Minimum measured quantity : see paragraph 1.2 of Description Accuracy class : 0,3; 0,5 and 1,0 Environment classes : M3 / E3 Temperature range liquid : -10 C / +50 C Temperature range ambient : -40 C / +55 C Further properties and test results are described in the annexes: Description TC7050 revision 6; Documentation folder TC7050-4. Remarks This revision replaces the previous versions, including its documentation folder; The measurement sensor is approved for measuring mass. Some versions are also approved for measuring density and volume. See paragraph 1.2 of the description for details. Issuing Authority 29 July 2013 1 C. Oosterman Head Certification Board 101 Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands T +31 78 6332332 certin@nmi.nl www.nmi.nl This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability. Parties concerned can lodge objection against this decision, within six weeks after the date of submission, to the general manager of NMi (see www.nmi.nl). Reproduction of the complete document only is permitted.

Page 1 of 4 1 General information on the measurement transducer All properties of the measurement sensor, whether mentioned or not, shall not be in conflict with the legislation. This Evaluation Certificate is the positive result of the applied voluntary, modular approach, for a component of a measuring instrument, as described in WELMEC guide 8.8. The complete measuring system must be covered by an EC type-examination Certificate. 1.1 Essential Parts - Measurement sensor, see the accompanying Documentation folder. Essentially, the measurement sensor consists of a housing in which two parallel measuring tubes are mounted. On the measurement tubes, three coils are mounted: one drive-coil and two pick-off coils. The drive coil, which is controlled by an external device, sets the measurement tubes in a vibrating motion. The pick-off coils generate signals representative for the frequency of motion of the measurement tubes. The resonant frequency depends, among other things, on the density of the liquid in the measurement tubes. The time difference between the signals from both pick-off coils depends on the mass flow of the liquid through the measurement tubes. Processing of the measurement signals is performed by the same external device that controls the drive coil. - In- and outputs The measurement sensor is equipped with several in- and outputs: - Drive current input, for setting the measurement tubes in a vibrating motion. - 2 Pick-off outputs, generating sinusoidal millivolt signals. - One 3-wire Pt-100 output, for the measurement of measurement tube temperature.

Page 2 of 4 1.2 Essential Characteristics 1.2.1 Flow characteristics Beside the characteristics stated on page 1 of this Evaluation Certificate TC7050, the sensor has the following characteristics: Mass measurement Sensor type Fxxx (xxx represents a number relating to the diameter of the sensor) F050 y) F100 y) F200 y) F300 y) Maximum Q max [kg/min] for all classes for accuracy class 0,3 for accuracy class 0,5 for accuracy class 1,0 Maximum pressure [bar(g)] Minimum Measured Quantity sensor [kg] Diameter in- and outlet [mm] 68 272 725 2268 9 36 116 362 4,5 18 58 181 2,3 36 58 181 345 (3) 5 10 20 200 12,5 25 50 80 Notes: - y) indicates the type of material the meter is build of. (1) : y) = S and A (3) :y) = P (2) : y) = H and B. - All sensor types can be used bi-directional. - The F-sensors can only be used in combination with the electronic flow transmitters mentioned in, and constructed according to Evaluation Certificate number TC7057. Volume measurement - The F050, F100 and F200 sensor are also approved for the measurement of density and volume. - The applicable values for Q max, Q min and MMQ in volume units are defined as: - Q max volume = Q max mass / maximum product density; - Q min volume = Q min mass / minimum product density ; - MMQ volume = MMQ mass / minimum product density. - Note: Meant are the minimum and maximum product density that can be expected for the actual product that is being measured and not the minimum and maximum product density as defined below under Measuring volume and density.

Page 3 of 4 1.2.2 Pressure correction and Temperature correction - Pressure correction a. Depending on the sensor characteristics, a dynamic pressure correction by means of a pressure transmitter is required when the pressure variation in the final application has an effect of more than 1/5 of the Maximum Permissible Error (MPE) for that application. b. When the sensor is calibrated at another average pressure then the average pressure in the final application (e.g. water calibration at low pressure), the corresponding pressure effect due to the pressure difference has to be considered. When the pressure effect is more than 1/5 of the MPE, then a pressure correction is required, either static (configured in electronics) or dynamic (pressure transmitter). c. The pressure coefficient values for the different sensors and the pressure values at which the correction has to take place for the different accuracy classes are mentioned in the documentation folder (7050/6-01). - Temperature correction In the flow transmitter (see Evaluation Certificate TC7057) a temperature correction is applied depending on the connected sensor type. Temperature correction for the sensor behaviour due to process temperature variations takes automatically place by default, based on the integral temperature sensor and the configured temperature coefficients in the electronics. - The temperature dependency on mass flow is called mass Flow Temperature coefficient FT (in % per 100 C). - The temperature dependency on density is called mass Density Temperature coefficient DT (in % per 100 C). 1.2.3 FD correction. FD represents the corrected tube period that is calculated while fluid flows through the sensor. The FD value must be separately determined during calibration. 1.2.4 LD Optimisation See document 7050/2-01 about details when the LD Optimisation is enabled or not. 1.3 Essential Shapes - Inscriptions. On the measurement sensor, clearly visible, at least the following is inscribed: - This Evaluation Certificate number: TC7050. - The sensor designation (type) - Serial number. - Seals. The measurement sensor is not sealed.

Page 4 of 4 2 Conditions for Conformity Assessment - Before taken into use the measurement sensor has to be calibrated on the product it is going to measure, at (if possible) operating temperature and pressure. This calibration can be performed on site or at a test place. In the latter case the relevant parameter settings have to be registered and checked at the initial verification on site. - If a measurement sensor is intended to be used with multiple liquids without adjustments, the sensor has to be calibrated on all applicable liquids, while the accuracy requirements are met for all products. - If the measurement sensor is applied in a measuring instrument: - If the sensor is used bi-directional, the examination in one direction is sufficient. - The use of this Evaluation Certificate is limited to: Other parties may use this Evaluation Certificate only with the written permission of Emerson Process Management Flow B.V., Neonstraat 1, 6718 WX Ede, the Netherlands. 3 Test results An overview of performed tests is given in the test reports: - No. CPC- 607073-02 issued by ; - No. CPC- 700915-01 issued by ; - No. CPC- 9200685-1 issued by ; - No. CPC- 11200060-01 issued by ; - No. NMi- 11200345-2 issued by ; - No. NMi- 10201042-1 issued by