Separation of Structurally Similar Steroids on HALO C18 and PFP

Similar documents
penta-hilic UHPLC COLUMNS

penta-hilic UHPLC COLUMNS

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

Breaking the speed limit: Fast, high-resolution peptide and tryptic digest separations using fused-core particles

Superficially Porous Silica Particles with Wide Pores for Biomolecular Separations

Alternatives to Sub-2 µm UHPLC Columns

Bringing uhplc Performance to the Separation of Peptides

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Discover the Advantages of HALO and HALO BioClass Fused-Core Columns

Discover the Advantages of HALO and HALO BioClass Fused-Core Columns

Discover the Advantages of HALO and HALO BioClass Fused-Core Columns

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Discover the Advantages of HALO and HALO BioClass Fused-Core Columns

A Look at Agilent HPLC Columns Choices

C18 Column. Care & Use Sheet

LC and LC/MS Column Selection Flow Chart

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Open Column Chromatography, GC, TLC, and HPLC

Kromasil Eternity Designed for long life

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Discover the Advantages of HALO and HALO BioClass Fused-Core Columns

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

LC Technical Information

Reversed Phase Solvents

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Trends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development

synergi Ultra-Performance HPLC The Concept Behind Synergi: Separate the Entire Polarity Spectrum Material Characteristics

Setting the Standard for ph Method Development

KromasilSFC. Designed for green technology. Introducing Kromasil SFC XT

High Resolution Fast LC

DEVELOPING HPLC METHODS WHEN C18 COLUMNS DON T WORK

NOTES. Zenix SEC-80. Sepax Zenix SEC-80 provides a valuable solution

Alltech Alltima HP Introduction

Packings for HPLC. Packings for HPLC

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Analysis - HPLC A.136. Primesep 5 µm columns B.136

HPLC COLUMNS VaRian, inc. Pursuit XRs EXtRa REsolution. Ma XiMuM lifetime. ultimate PERfoRMancE.

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

HPLC Method Development with Eclipse Plus: Standard Practices and New Columns. Agilent Technologies

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Successfully Scaling and Transferring HPLC and UPLC Methods

Impact of Pore Exclusion on Reversed-Phase HPLC Column Performance

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

It s hot! ZIC -chilic

BETASIL Columns TG Å high purity silica

Ultra-Performance LC Columns SM

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

Do you need trouble-free speed? The NEW Chromolith HR

Choosing Columns and Conditions for the Best Peak Shape

Evaporative Light Scattering Detector (ELSD)

HPLC Method Development: Standard Practices and New Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Small Molecule Selectivity Sampler

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

HPLC & LC-MS. Techniques to Improve Speed, Resolution and Sensitivity without Investing in Capital Equipment

Determination of Pharmaceuticals in Environmental Samples

The Challenge: Sepax SEC C-line columns!

HPLC Method Development: Standard Practices and New Columns. Agilent Technologies February 2007

How proteins separate on reverse-phase HPLC

Do you need trouble-free speed? The NEW Chromolith HR

1.7 m Fortis UHPLC Columns

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

H P L C C O L U M N S

Too Polar for Reversed Phase What Do You Do?

Kromasil Eternity Designed for long life

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

Technical Guide Thermo Scientific Syncronis HPLC Columns

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns

8. Methods in Developing Mobile Phase Condition for C18 Column

Your Reversed Phase Method

for Acclaim Mixed-Mode HILIC-1 Column

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Getting More Resolution from Your LC Michael Woodman Columns and Consumables September 10, 2008

Setting the Standard for ph Method Development

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

HPLC UHPLC Columns. Dikma Technologies Inc.

Logical Method Development for Peptides and Proteins Using RP-HPLC and SEC

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Applications. Overview of applications of elevated temperature and temperature programmed liquid chromatography

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Fast Screening Methods for Beta Blockers by HPLC with Agilent Poroshell 120 Columns

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Analysis of Positional Isomers with Agilent Poroshell 120 PFP Columns

Method Development for Chiral LC/MS/MS Analysis of Acidic Stereoisomeric Pharmaceutical Compounds with Polysaccharide-based Stationary Phases

William E. Barber, Ph.D. Applications Chemist October

LC MS analysis of metabolites. Basis of Chromatography

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

A C18 Silica Column With Exceptional Temperature and ph Stability

CLIPEUS - A Small Shield for a Big Job

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Transcription:

Application Note: 047-STR Separation of Structurally Similar Steroids on HALO C8 and PFP, 4 G009 HALO C8 HALO PFP 4. Prednisone. Cortisone. Prednisolone 4. Hydrocortisone 0 4 5 6 7 Columns: 4.6 x 00 mm, HALO C8 4.6 x 00 mm, HALO PFP Part Numbers: C8, 984-60 PFP, 984-609 Mobile Phase: 50/50: water/methanol Flow Rate:.0 ml/min. Pressure: About 0 Bar Temperature: 5 C Detection: UV 40 nm, VWD Injection Volume: 0.5 µl Sample Solvent: 80% methanol in water Response Time: 0.0 sec. Flow Cell:.5 µl semi-micro ECV: ~4 µl Prednisone Prednisolone Cortisone Hydrocortisone The unique selectivity of HALO PFP is useful in the separation of the closely related steroids prednisolone and hydrocortisone. The electron-deficient ring structure of the perfluorophenyl group aids in separating compounds through pi-pi interactions with the sample.

Application Note: 57-AM Isocratic Separation of Amphenicols on HALO Phenyl-Hexyl Phase G009. Thiamphenicol. Chloramphenicol 40 nm 80 nm 0.0 0. 0.4 0.6 0.8.0 Column: 4.6 x 50 mm, HALO Phenyl-Hexyl Part Number: 984-406 Mobile Phase: 55/45-A/B A= 0.05 M Ammonium acetate buffer, ph=5.8 B=Acetonitrile Flow Rate:.0 ml/min. Pressure: 94 Bar Temperature: 5 C Detection: UV 40/80 nm, VWD Injection Volume: 0. μl Sample Solvent: Acetonitrile Response Time: 0.0 sec. Flow Cell:.5 μl semi-micro Extra column volume: ~4 μl Thiamphenicol Chloramphenicol This separation shows a rapid HPLC method for the analysis of amphenicols on HALO Phenyl-Hexyl stationary phase. To improve the sensitivity of detection the first peak was monitored @ 40 nm and the second @ 80 nm. :

Application Note: 5-BZ Separation of Benzodiazepines on HALO Phenyl-Hexyl, C8, and PFP Phases STRUCTUR G00A G00B G00C. Oxazepam. Lorazepam. Nitrazepam 4. Alprazolam 5. Clonazepam 6. Temazepam 7. Flunitrazepam 8. Diazepam Columns: 4.6 x 50 mm, HALO Phenyl-Hexyl, C8, and PFP Part Numbers: 984-406, 984-40, and 984-409, respectively Mobile Phase: A= 5 mm Ammonium acetate in water (ph=5.8 not adjusted), B= Acetonitrile Gradient from 4-6% B in.5 minutes Flow Rate:.5 ml/min. Pressure: 00 Bar Temperature: 5 C Detection: UV 54 nm, VWD Injection Volume:.0 μl Standard diluted with Acetonitrile and buffer Response Time: <0. sec. Flow Cell: 5 μl semi-micro LC System: Agilent 00 Gradient dwell volume= 0.88 ml Oxazepam Lorazepam Alprazolam Clonazepam Flunitrazepam Diazepam These separations of benzodiazepines on three different HALO Fused-Core HPLC stationary phases show the utility of having a variety of phases to optimize selectivity and/or to shorten analysis time. Nitrazepam Temazepam

Application Note: 04-ST Separation of Statin Drugs on HALO C8 G006 4 STRUCTUR. Pravastatin. Atorvastatin. Mevastatin 4. Simvastatin 0.0 0. 0.4 0.6 0.8.0. Column: 4.6 x 50 mm, HALO C8 Part Number: 984-408 Mobile Phase: 0/80: A/B A= 0.0 M formic acid in water B= 0.0 M formic acid in methanol Flow Rate:.0 ml/min. Pressure: 40 Bar Temperature: 0 C Detection: UV 40 nm, VWD Injection Volume:.0 μl Sample Solvent: mobile phase Response Time: 0.0 sec. Flow Cell:.5 μl semi-micro ECV: ~4 μl Pravastatin Mevastatin The statin drugs can be rapidly separated using short HALO C8 columns. Atorvastatin Simvastatin

Application Note: 65-B Separation of Antiulcer Drugs on HALO Penta-HILIC G0047 (54 nm) 4 STRUCTUR. Cimetidine. Nizatidine. Famotidine 4. Ranitidine 0.0 0. 0.4 0.6 0.8.0..4.6 Column: 4.6 x 00 mm, HALO Penta-HILIC Part Number: 984-605 Mobile Phase: 0/90: A/B A= 0.04 M Ammonium formate, ph=.0 (adj.) B= Acetonitrile Flow Rate:.0 ml/min. Pressure: 0 Bar Temperature: 0 C Detection: UV 54 nm, VWD Injection Volume: μl Sample Solvent: mobile phase Response Time: 0.0 sec. Flow Cell:.5 μl semi-micro ECV: ~4 μl The strongly basic antiulcer drugs can be rapidly separated on HALO Penta-HILIC phase using a mobile phase that works well with a mass spectrometer detector. Cimetidine Nizatidine Famotidine Ranitidine

Application note: 64-B Separation of 5 Beta Blocker Drugs on HALO Penta-HILIC (54 nm) 4 G0046 STRUCTUR 5. Alprenolol. Propranolol. Pindolol 4. Acebutolol 5. Atenolol 0.0 0. 0.4 0.6 0.8.0..4.6.8 Column: 4.6 x 00 mm, HALO Penta-HILIC Part Number: 984-605 Mobile Phase: 0/90: A/B A= 0.04 M Ammonium formate buffer, ph=.0 B= Acetonitrile Flow Rate:.0 ml/min. Pressure: 5 Bar Temperature: 0 C Detection: UV 54 nm, VWD Injection Volume:.0 μl Sample Solvent: mobile phase Response Time: 0.0 sec. Flow Cell:.5 μl semi-micro ECV: ~4 μl Alprenolol Propranolol Pindolol Acebutolol The HALO Penta-HILIC stationary phase can rapidly separate highly basic compounds with good peak shapes in a mass spectrometry friendly mobile phase. Atenolol

Application Note: 60-CB Separation of Carbamate Pesticides on HALO ES-CN Phase G004. Carbetamide. Propham. Chlorpropham 0 0. 0. 0. 0.4 0.5 0.6 Column: 4.6 x 50 mm, HALO ES-CN Part Number: 984-404 Mobile Phase: 40/60-A/B A= Water B=Acetonitrile Flow Rate:.0 ml/min. Pressure: 65 Bar Temperature: 0 C Detection: UV40 nm, VWD Injection Volume: 0. μl Sample Solvent: Acetonitrile Response Time: 0.0 sec. Flow Cell:.5 μl semi-micro Extra column volume: ~4 μl Carbetamide Propham This separation illustrates a rapid HPLC determination of three carbamate pesticides on HALO ES-CN phase in just over half a minute. The unique Fused-Core technology allows the use of high flow rates at moderate pressures while retaining high efficiency. Chlorpropham :

Application Note: 54-P Isocratic Separation of Phenyl Ureas on HALO ES-CN 4 5 6 G006. Fenuron. Monuron. Fluomethuron 4. Diuron 5. Linuron 6. Neburon 0.0 0.5.0.5.0 Column: 4.6 x 50 mm, HALO ES-CN Part Number: 984-404 Mobile Phase: 50/50-A/B A=0.0 M Phosphate buffer, adj. to ph=.5 B=Acetonitrile Flow Rate:.0 ml/min. Pressure: 00 Bar Temperature: 0 C Detection: UV 45 nm, VWD Injection Volume: 0.5 μl Sample Solvent: Acetonitrile/water Response Time: 0.0 sec. Flow Cell:.5 μl semi-micro Extra column volume: ~4 μl Fenuron Fluomethuron Linuron Monuron Diuron Neburon This separation is an example of a rapid analysis of phenyl urea compounds on a HALO ES-CN column in under minutes. :

Application Note: 0-P Rapid Isocratic Separation of Fibrates on HALO C-8 Phase. Bezafibrate. Gemfibrozil. Fenofibrate t 0 0 0. 0. 0. 0.4 0.5 0.6 Column: 4.6 x 50 mm, HALO C-8 Part Number: 984-40 Mobile Phase: 0/80-A/B A= 0.0 M Phosphate buffer, ph=.0 B=Acetonitrile Flow Rate:.5 ml/min. Pressure: 50 Bar Temperature: 45 C Detection: UV 0 nm, VWD Injection Volume: 0. μl Sample Solvent: 50/50-methanol/acetonitrile Response Time: 0.0 sec. Flow Cell:.5 μl semi-micro Extra column volume: ~4 μl Bezafibrate Fenofibrate Fibrates are a class of cholesterol lowering drugs that can be rapidly analyzed using Halo C-8 phase to obtain widely separated peaks in about 0 seconds. Gemfibrozil :

Application Note: 6-PT Separation of Peptides and Small Proteins on HALO Peptide ES-C8 4 8 5 6 7 G0044 9 0 STRUCTUR. Gly Tyr. Val Tyr Val. Angiotensin ( 7) amide 4. Met Enk 5. Angiotensin ( 8) amide 6. Angiotensin II 7. Leu Enk 8. Ribonuclease A 9. Angiotensin ( ) (human) 0. Angiotensin ( ) (mouse). Porcine insulin 0.0 0. 0. 0. 0.4 0.5 0.6 0.7 0.8 0.9.0 Time (min.) Column: 4.6 x 50 mm, HALO Peptide ES-C8 Part Number: 94-40 Mobile Phase: A= 90%(0.% TFA in water)/0% acetonitrile B= 0% (0.% TFA in water)/70% acetonitrile Gradient: 0% B to 87% B in minute Flow Rate: 5.0 ml/min. Pressure: 0 Bar Temperature: 60 C Detection: UV 0 nm, VWD Injection Volume:.0 μl Sample Solvent: Mobile Phase A Response Time: < 0. sec. Flow Cell: 5 μl semi-micro LC System: Quaternary Agilent 00 Gradient dwell volume is 0.88 ml DISCUSSION: This separation shows the utility of the HALO Fused-Core Peptide ES-C8 stationary phase for the separation of peptides by HPLC. An average pore size of about 60 Angstroms enhances the mass transfer of peptides and small proteins of up to a molecular weight of approximately 5 kd, depending on the molecular configuration. Also, the stationary phase is a sterically protected C8 bonded silane to increase resistance to low ph mobile phases and elevated temperatures (up to 00 C.) that are commonly used in the separation of many biological materials. HALO and Fused Core are registered trademarks of Advanced Materials Technology, Inc.