xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

Similar documents
THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

Best selling products overview of company AURA a.s.

QUANTUM CONCEPT. Swimming User s Manual

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

SUBJECT TO CHANGE WITHOUT NOTICE

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

MCB NB1-63H Miniature Circuit Breaker

473-SHX Dew Point Mirror

Microcare LCD Solar MPPT User Documentation

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Small Panel with matrix screen

POINTS OF CAUTION BEFORE USE...

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

All-in-one or BOX industrial PC for autonomous or distributed applications

5SJ4...-.HG Circuit Breakers to IEC and UL 489

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

ISSP User Guide CY3207ISSP. Revision C

HiPace 300 with TC 400, DN 100 CF-F

Smart Sensing Embedded Spectroscopy Platform Botlek studiegroep 06-april-2017

PCAN-MicroMod Evaluation Kit. Test and Development Environment for the PCAN-MicroMod. User Manual

473 Dew Point Hygrometer

DIN Timers TD. Options and ordering codes. Specification

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

Metso Concentration Measurement 3300

Display counter electromechanical

CapaciTorr HV 200 HIGHLIGHTS

BMXART0814 analog input module M340-8 inputs - temperature

473 Dew Point Hygrometer

Product description. Developing lighter, more compact and. photoelectric sensor offers completely. ligent features: the sensors feature

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

FlexSQUARE Square shaped beacons

HiPace 300 with TC 110, DN 100 CF-F

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

SINAMICS G120X. Available in power ratings up to 700 hp (630 kw) Technical documentation 01 / 2019

Hands-on Lab 3. System Identification with Experimentally Acquired Data

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Minute Impulse Clock Controller I01DN

CapaciTorr HV Pumps. making innovation happen,together

HiPace 1200, with TC 1200, DN 200 CF-F

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

General Information: Real-time onsite solar forecasting

LOG_aLevel. Tsunami Warning System

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

No /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.

PHOENIX CONTACT - 04/2016. Features

Information Technology Solutions Neptune Datasheet

FATEK. FBs-1HLC. Precision Load Cell Module. Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP.

Regulated 3.3V Charge Pump MAX679

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

ISM Evolution. Elscolab. Nederland BV

ElectroMechanical Cylinder LEMC

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

32 Input AC Block I/O Module

SIMATIC Ident Industrial Identification Systems

OPERATING MANUAL. EIB-Kombisensor AS 315 N

Application Note - SolarEdge Inverters, Power Control Options

16 Input AC Block I/O Module

Determination of the Rydberg constant, Moseley s law, and screening constant (Item No.: P )

Motors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1.

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

FAGOR 8055i CNC Ordering Handbook. Ref. 1502

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Period/Frequency Output

INSTRUCTION MANUAL FOR MM10 Relay

W 30 Photoelectric proximity switches: Clear signals even with low remission

Standard specifications ZX165UFE02001

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka

Chilled Mirror Hygrometry

E2T0 DVP

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

UL 1077 DIN Rail Supplementary Protectors

MULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS UMX-4 & UMX-8

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

RainMachine Mini- 8 Quick- Start Guide

FSUSB31 Low-Power 1-Port Hi-Speed USB 2.0 (480Mbps) Switch

Mercury Stack Monitor SM-4

Multi-element process analyzer

BMXART0814 analog input module M340-8 inputs - temperature

Grabber. Technical Manual

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

FAGOR 8055 CNC Ordering Handbook. Ref. 1502

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

Non-Contact Safety Systems CMS

MAGPOWR TENSION CONTROL DLCA NET-SLIM. User Manual. Digital Load Cell Amplifier MI 850A358 1 A

PAA-ANALYZERS PRINCIPLE OF OPERATION

PYCKO SCIENTIFIC LIMITED

Drive electronics pq12

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Transcription:

SuperRelay S U P E R R E L A Y, T H E P E R F E C T A L T E R N A T I V E T O L O W C O S T P L C s A N D B A S I C R E L A Y S I N T H I S B R O C H U R E : ELC 18 Standard Models ELC 18 Economy Models ELC 12 Standard Models ELC 18 Expansion Modules ELC SMS Module ELC Ethernet Module ELC xlogicsoft configuration tool xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters. The xlogic SuperRelay perfectly fits in the space between timing relays and low-end PLCs. Each CPU incorporates not only a real-time clock and calendar, but also provides support for optional expansion I/O modules to enhance control and monitoring applications. The xlogic SuperRelay is the ideal solution for relay / PLC replacement, or simple control applications as building and parking lot lighting, access control, watering systems, pump control, ventilation systems, home automation and a wide field of applications demanding low cost to be a primary design issue. I N F O @ S U P E R - R E L A Y. C O M

Powerful build-in HMI-display features...and more! ELC-18 Series C u s t o m i z a b l e S t a r t - u p p a g e / s c r e e n W i t h B u i l d i n H M I f e a t u r e s 4 l i n e, 1 0 c h a r a c t e r b a c k l i g h t O p t i o n a l m e t a l m o u n t i n g p l a t e o f f e r s d i s p l a y m o u n t i n g t o t h e r e a r o f t h e c o n t r o l p a n e l d o o r. V a r i o u s v a l u e s / s e t t i n g s a n d p a r a m e t e r s c a n b e v i e w e d a n d U n i t S i z e a l l o w s f o r D I N - r a i l m o u n t i n g a d j u s t e d d i r e c t l y t h r o u g h t h e H M I t o g e t h e r w i t h c o m m o n l y u s e d b r e a k e r s d i s p l a y. i n b u i l d i n g a u t o m a t i o n a p p l i c a t i o n s. V a r i o u s b l o c k s d i f f e r e n t P r o g r a m m i n g d o n e a s w i t h a n y r e g u l a r p a r a m e t e r s c a n b e d i s p l a y e d o n H M I ( n o t j u s t v i a k e y p a d a s m o s t o n e s c r e e n / p a g e s i m u l t a n e o u s l y s i m i l a r p r o d u c t s ). R a n d o m l y s p e c i f y a s p e c i f i c p a g e t o d i s p l a y t h e I O s t a t u s o f t h e E L C 1 8 o r e x p a n s i o n m o d u l e a t t a c h e d A l a r m p a g e c a n r e c o r d a n d d i s p l a y t h e e x a c t a l a r m o c c u r r e n c e t i m e R e t e n t i v e m e m o r y c a p a b i l i t y s t a n d a r d f e a t u r e o n t h e E L C - 1 8 m o d e l. 1 0 B I T S A n a l o g i n p u t r e s o l u t i o n. C E - a p p r o v e d P r o g r a m m a b l e u p t o 3 2 ( u s e r d e f i n e d ) s c r e e n s / p a g e s

Connect optional expansion modules. Connect optional SMS / GSM message module. Connect optional Ethernet module. Connect HMI / Operator Panel using Modbus. ELC-18 Series MO D EL PO WER SUPPLY IN P UT S O U TP U TS RT C P W M ELC-18AC-R AC 110~240V ELC-18AC-L-R AC 110~240V ELC-18DC-D-R ELC-18DC-D-TN 2 Ch. ELC-18DC-D-TP 2 Ch. ELC-18DC-DA-R 8 Digital / Analog + 4 Digital ELC-18DC-DA-TN 8 Digital / Analog + 4 Digital 2 Ch. ELC- 18DC-DA-TP 8 Digital / Analog + 4 Digital 2 Ch. GENERAL SPECIFICATIONS Timers : 256 Counters : 256 Function Blocks : 256 Operation temp. : 0-55 Storage :-40-70 Protection : IP20 RTC accuracy : MAX ±5S/day RTC time intervals : 256 RTC Backup at 25 C: 10 hours Power-off retentivity : yes Storage capacity : 128K Dimensions : 95*90*55 Unit mm Certificate : CE Installation : DIN rail or screw for installation Expansion capacity : 9 analog PCS modules or up to 31 n-analog modules (ELC-E-16, CAN BUS)

ELC-18 Models ELC-18AC-R Rated voltage: AC 100-240V AC220V consumption: 3W Main voltage operation range: AC85-256V Allowable main frequency: 47-63Hz Signal 0: AC 0-40V Signal 1: AC79-240V Input current: < 0.03mA Input current: >0.08mA High-speed counting: IB, IC (Max.99k Hz) ELC-18DC-D-R (Output full-load) Typical 3W Signal 0: DC 0-3V Signal 1: DC 8-24V High-speed counting: IB, IC (Max.99k Hz) ELC-18DC-DA-R (Output full-load) Typical 3W Signal 0: DC 0-3V Signal 1: DC 8-24V High-speed counting: IB, IC (Max.99k Hz) Analog input Signal: DC 0-10V

ELC-18 Models ELC-18DC-D-TP (Output full-load) Typical 3W Signal 0:DC 0-3V Signal 1:DC 8-24V High-speed counting: IB, IC (Max.99k Hz) Output type: transistor (PNP type) continuous current max value: MAX.0.3A PWM: 2 channels (Q5, Q6) ELC-18DC-DA-TP (Output full-load) Typical 3W Signal 0:DC 0-3V Signal 1:DC 8-24V High-speed counting: AI8 (Max.99k Hz) Analog input Signal: DC 0-10V Output type: transistor (PNP type) continuous current max value: MAX. 0.3A PWM: 2 channels (Q5, Q6) Consult our website For the latest updated information www.super-relay.com

Connect optional SMS / GSM message module. Connect HMI / Operator Panel using Modbus. ELC-18 Economy MO D EL PO WER SUPPLY IN P UT S O U TP U TS RT C P W M H S C* ELC-18AC-R-E AC 110~240V ELC-18AC-L-R-E AC 110~240V ELC-18DC-D-R-E ELC-18DC-D-TN-E ELC-18DC-D-TP-E ELC-18DC-DA-R-E 8 Digital / Analog + 4 Digital ELC-18DC-DA-TN-E 8 Digital / Analog + 4 Digital ELC- 18DC-DA-TP-E 8 Digital / Analog + 4 Digital H S C = H i g h S p e e d C o u n t GENERAL SPECIFICATIONS Timers : 256 Counters : 256 Function Blocks : 256 Operation temp. : 0-55 Storage :-40-70 Protection : IP20 RTC accuracy : MAX ±5S/day RTC time intervals : 256 RTC Backup at 25 C: 10 hours Power-off retentivity : yes Storage capacity : 128K Dimensions : 95*90*55 Unit mm Certificate : CE Installation : DIN rail or screw for installation Expansion capacity : 31 modules (ELC-E-16, CAN BUS)

ELC-18 Models Rated voltage: AC 100-240V AC220V consumption: 3W Main voltage operation range: AC85-256V Allowable main frequency: 47-63Hz ELC-18AC-R-E Signal 0: AC 0-40V Signal 1: AC79-240V Input current: < 0.03mA Input current: >0.08mA (Output full-load) Typical 3W ELC-18DC-D-R-E Signal 0: DC 0-3V Signal 1: DC 8-24V (Output full-load) Typical 3W ELC-18DC-DA-R-E Signal 0: DC 0-3V Signal 1: DC 8-24V Analog input Signal: DC 0-10V

ELC-18 Models (Output full-load) Typical 3W ELC-18DC-D-TP-E Signal 0:DC 0-3V Signal 1:DC 8-24V Output type: transistor (PNP type) continuous current max value: MAX.0.3A (Output full-load) Typical 3W ELC-18DC-DA-TP-E Signal 0:DC 0-3V Signal 1:DC 8-24V Analog input Signal: DC 0-10V Output type: transistor (PNP type) continuous current max value: MAX. 0.3A Consult our website For the latest updated information www.super-relay.com

Rugged, low cost model. DIN Rail or Wall mounted. Connect optional Ethernet module. Connect HMI / Operator Panel using Modbus. 1 route High Speed Counting on all units ELC-12 Series MO D EL PO WER SUPPLY IN P UT S O U TP U TS RT C P W M H S C ELC-12AC-R AC 110~240V 8 Digital 4 Relays ELC-12DC-D-R 8 Digital 4 Relays ELC-12DC-D-TN 8 Digital 4 Transistors 1 Ch. ELC-12DC-D-TP 8 Digital 4 Transistors 1 Ch. ELC-12DC-DA-R 8 Digital / Analog 4 Relays ELC-12DC-DA-TN 8 Digital / Analog 4 Transistors 1 Ch. ELC- 12DC-DA-TP 8 Digital / Analog 4 Transistors 1 Ch. GENERAL SPECIFICATIONS Timers : 130 Counters : 130 Function Blocks : 130 Operation temp. : 0-55 Storage :-40-70 Protection : IP20 RTC accuracy : MAX ±5S/day RTC time intervals : 130 RTC Backup at 25 C: 72 hours Power-off retentivity : Storage capacity : 128K Dimensions : 72*90*53 (Unit, mm Certificate : CE Installation : DIN rail or screw for installation Expansion capacity :

ELC-12 Models ELC-12AC-R Rated voltage: AC 110-240V AC220V consumption: 3W Main voltage operation range: AC85-256V Allowable main frequency: 47-63Hz Signal 0: AC 0-40V Signal 1: AC79-240V Input current: < 0.03mA Input current: >0.08mA High-speed counting: I8 (Max.99k Hz) ELC-12DC-D-R (Output full-load) Typical 3W Signal 0: DC 0-3V Signal 1: DC 8-24V High-speed counting: I8 (Max.99k Hz) ELC-12DC-DA-R (Output full-load)typical 3W Signal 0:DC 0-3V Signal 1:DC 8-24V High-speed counting: AI8 (Max.99k Hz) Analog input Signal: DC 0-10V

ELC-12 Models (Output full-load)typical 3W ELC-12DC-D-TP Signal 0:DC 0-3V Signal 1:DC 8-24V High-speed counting: I8 (Max.99k Hz) Output type: transistor(pnp type) output continuous current max value: MAX.0.3A PWM: 1 channel (Q4) (Output full-load) Typical 3W ELC-12DC-DA-TP Signal 0:DC 0-3V Signal 1:DC 8-24V High-speed counting: AI8 (Max.99k Hz) Analog input Signal: DC 0-10V Output type: transistor(pnp type) output continuous current max value: MAX. 0.3A PWM: 1 channel (Q4) Consult our website For the latest updated information www.super-relay.com

Expansion Module Connect to the STANDARD ELC-18 Series Module. Connect up to 31 modules. ELC-E-16AC-R P O W E R AC 110~240V I N P U T S 8 AC Digital O U T P U T S 4 Relays (10A) 4 Relays (3A) D I G I T A L I N P U T S ELC-E-16DC-D-R P O W E R I N P U T S 8 DC Digital O U T P U T S 4 Relays (10A) 4 Relays (3A) D I G I T A L I N P U T S ELC-E-16DC-DA-R P O W E R I N P U T S 6 DC Digital & 2 Analog / Digital O U T P U T S 4 Relays (10A) 4 Relays (3A) D I G I T A L I N P U T S Signal 0: AC 0-40V Input current: <0.03mA Signal 0: DC 0-3V Input current: <1.0mA Signal 0: DC 0-3V Input current: <1.0mA Signal 1: AC 0-40V Input current: <0.03mA Signal 1: DC 8-24V Input current: <1.5mA Signal 1: DC 8-24V Input current: <1.5mA D I G I T A L O U T P U T S D I G I T A L O U T P U T S A N A L O G O U T P U T S Output Type: Relay output. Continuous Max. Current Value: Q1 Q4: Max 3A Q5 Q8: Max 10A Output Type: Relay output. Continuous Max. Current Value: Q1 Q4: Max 3A Q5 Q8: Max 10A Signal: DC 0-10V D I G I T A L O U T P U T S Output Type: Relay output. Continuous Max. Current Value: Q1 Q4: Max 3A Q5 Q8: Max 10A SMS Module Remote control the ELC 18 SuperRelay via SMS. Remote monitoring via SMS messages (Alarms, Status, etc). Easy configuration with free of charge xlogicsoft software. ELC-SMS-D-R Incorporating the ELC-SMS-D-R module into a system allows the user full remote monitoring as well as remote control of the application via SMS (Short Message Service) on any GSM phone or PDA. Worldwide availability, low operating cost, easy installation and integration in combination with high reliability makes SMS remote control and monitoring a desirable option in hard to reach, distant or hazardous environments. GSM Network support: The ELC-SMS-D-R is equipped with a Quad-band GSM module offering seamless functionality on 850Mhz, 900Mhz, 1800Mhz, 1900Mhz. Consult the SMS user manual for complete technical and installation details.

Ethernet Module Cable Modules Add the ELC-Ethernet module and provide Ethernet capability to your ELC SuperRelay. Two standard communication and configuration interface cables are available: RS232 and USB. ELC-Ethernet-DC module ELC-Ethernet-AC module ELC-RS232 ELC-USB xlogicsoft Free of charge SuperRelay configuration software. Library with pre-configured function blocks for ultra fast set-up. Function Block / Ladder programming. On-line Monitor & Off-line Simulation Free upgrades for all future software versions. Free Personal Tutorials Using the dialog boxes, function block parameter setup and modification is a quick and easy task to complete. Link function blocks to complete your program. Set up as many as 256 (ELC-18) function blocks in one circuit program. Use the label tool to write a comment, instruction or help note on the on the xlogic circuit program screen. V I S T O U R W E B S I T E A T A N D D O W N L O A D Y O U R T H E X L O G I C S O F T S O F T W A R E & U S E R M A N U A L F O R F R E E!