ICP-MS-based characterization of inorganic nanoparticles sample

Similar documents
ICP-MS-based characterization of inorganic nanoparticles sample preparation and off-line fractionation strategies

Examples of Method Validation Studies Conducted in Different Economies

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

ICP-OES Application Note Number 35

Dartmouth Trace Element Analysis Core: Lab methods

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

TITLE NANOPARTICLE SUSPENSIONS COUNTING AND SIZING NANOPARTICLES VIA SINGLE PARTICLE INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

DISCLAIMER: This method:

CEINT/NIST PROTOCOL REPORTING GUIDELINES FOR THE PREPARATION OF AQUEOUS NANOPARTICLE DISPERSIONS FROM DRY MATERIALS. Ver. 2.0

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Fast ph-assisted functionalization of silver nanoparticles with monothiolated DNA

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

Imaging gold nanoparticles in mouse liver by laser ablation inductively coupled plasma mass spectrometry

Supporting Information

Preparing Colloidal Gold for Electron Microscopy

A Comparison of Microsecond vs. Millisecond Dwell Times on Particle Number Concentration Measurements by Single Particle ICP-MS

Supporting Information

Analysis of domestic sludge using the Agilent 4200 MP-AES

Study of Nanoparticles in a Few Rivers in North East Italy using SP-ICP-MS

Mercury Determination in Lichen, BCR-482, Using the QuickTrace M-7600 CVAAS Mercury Analyzer

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Traceability, validation and measurement uncertainty 3 pillars for quality of measurement results. David MILDE

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Supporting Information

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Accurate Sizing and Precise Counting of 10 nm Gold Nanoparticles using the Enhanced Sensitivity of the NexION 2000 ICP-MS

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Assessing the Fate of Nanoparticles During Coagulation Using SP-ICP-MS. ICP - Mass Spectrometry APPLICATION. Introduction

Quantification of ligand packing density on gold nanoparticles using ICP-OES

NICKEL-63/59 IN WATER

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Determination of Zinc, Cadmium, Lead and Copper in Effluent Sample

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Accurate Quantification of Cadmium, Chromium, Mercury and Lead in Plastics for RoHS Compliance using the Agilent 7500ce ICP-MS

Supporting Information. Single Particle Detection by Area Amplification Single Wall Carbon Nanotube Attachment to a Nanoelectrode

Samples compliant with the WATER

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Single Analyte Custom Grade Solution. CGWH2O1 M2-W H2O µg/ml ea: Tungsten Ammonium Metatungstate

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Observation of size-independent effects in nanoparticle retention behavior during asymmetric-flow field-flow fractionation

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

High-Throughput Semiquantitative Screening of Ambient Air Samples by ORS-ICP-MS and Integrated Sample Introduction System (ISIS) Application

ANALYSIS CERTIFICATE OF 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Not Just for Paint Chips Anymore. High Throughput, Open Vessel Microwave Digestion of Matrices Requiring Moderate Conditions

Center for Cell Imaging Department of Cell Biology

Fergus Keenan Shona McSheehy Julian Wills

Elemental Scientific. Spike Recovery. Elemental Scientific

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

Supporting Information for

SP-ICP-MS Analysis of Size and Number Concentration in Mixtures of Monometallic and Bimetallic (Core-shell) Nanoparticles

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Elemental Scientific. Spike Recovery. Elemental Scientific

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Development and validation of the test guideline on agglomeration behavior of nanomaterials in different aquatic media.

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3163 Lot Number:

Rapid determination of five arsenic species in polished rice using HPLC-ICP-MS

SeCtiOn 5 [STOCK AND CUSTOM] Assurance. Multi-Element CLP Standards

Heteroagglomeration of nanosilver with colloidal SiO2 and clay

Basic Digestion Principles

Three Dimensional Nano-assemblies of Noble Metal. Nanoparticles-Infinite Coordination Polymers as a Specific

Test Method: CPSC-CH-E

Supplementary Material (ESI) for Chemical Communications This journal is (c) The Royal Society of Chemistry 2009

Experiment 1 (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with 1,10- Phenanthroline

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

TECHNETIUM-99 IN SOIL

Analytical Approaches to Arsenic

CERTIFICATE OF. Single Analyte Custom Grade Solution g/ml (measured at 20 ± 4 ºC) Graviametric NIST SRM Lot Number: See Sec. 4.

Modulating Enzymatic Activity in the Presence of Gold Nanoparticles

Nanomaterials and Chemistry Key Laboratory, Wenzhou University, Wenzhou, (P. R. China).

METHOD SCOPE AND APPLICATION

Panayot Petrov, John Entwisle, Heidi Goenaga-Infante GC-ICP-MS reference methodology to quantify polybrominated flame retardants in environmental

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

Instantaneous and Quantitative Functionalization of Gold Nanoparticles with Thiolated DNA Using a ph-assisted and Surfactant-Free Route

In a typical routine, the pristine CNT (purchased from Bill Nanotechnology, Inc.) were

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

Nanoparticle Analysis: An Upcoming Challenge for Environmental Analysis

Graphene oxide was synthesized from graphite using the MH (modified Hummer s method) 30 and

CHEMICALS & REAGENTS

Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Limit-test of NDMA and NDEA in Sartans. by GC-MS (Liquid-direct-injection)

Transcription:

Analytical and Bioanalytical Chemistry Electronic Supplementary Material ICP-MS-based characterization of inorganic nanoparticles sample preparation and off-line fractionation strategies Anne-Lena Fabricius, Lars Duester, Björn Meermann, and Thomas A. Ternes 1

Experimental Table S1. Information about the nanoparticle suspensions used given by the manufacturer AgPURE-W TiO 2 CeO 2 Au 10 nm Au 200 nm ZnO ras materials GmbH, Germany Laboratory synthesized NYACOL; Nanotechnologies, Inc, USA Sigma-Aldrich, Germany Particular GmbH, Germany Concentration 10.0 ± 0.50 % 5.9 g/l 20 wt.% 5.9 10 12 part/ml 1.9 10 9 part/ml 100 mg/l Additives Ammonium nitrate (3-15%) None Nitrate (0.2 mol/mol) Sodium citrate buffer (100 mg/l) + proprietary stabilizing surfactant Sodium citrate buffer (100 mg/l) Core size; (diameter) [nm] Hydrodynamic diameter [nm] 15 (99%< 20) 100 10-20 8-12 180-220 - - - - 18-30 175-235 136.1 ± 4.2 2

Table S2. Details about microwave assisted digestion procedures Ag TiO 2 CeO 2 ZnO Au HNO 3 (65%) 1.4 ml - 1.2 ml 0.35 ml 0.35 ml H 2 SO 4 (96%) - 1.4 ml - - - HCl (30%) - - - 1.05 ml 1.05 ml H 2 O 2 (30%) - - 0.2 ml - - Vessel material Teflon Teflon Teflon Teflon Glass Internal Standard Sample Ru (1 mg/l) 0.1 ml 0.5 ml Dilution 1:100.000 1:1.000 1:100.000 1:100 1:100 Assumed concentration ~1 mg/l ~5.9 mg/l ~2 mg/l ~1 mg/l 99.4 µg/l* 253 µg/l* ph value 5.8 5.8 4.5 5.9 6.2 6.3 Reference material TMDA52.3**: 20.6 ± 1.8 µg/l TMDA52.3**: 120.0 ± 7.6 µg/l SPS-SW2*** 2.5 ± 0.02 µg/l TMDA**: 263.0 ± 25.3 µg/l Noble metals****: 100 µg/l ICP-element std Ag (1 mg/l) Ti (1 mg/l) Ce (1 mg/l) Zn (1 mg/l) Au (1 mg/l) * Conversion from concentrations given in particles/ml (information of the customer) to the concentration of Au in µg/l were conducted in accordance to [1]. ** Certified Reference Waters for Trace Elements, Environment Canada. *** Surface water trace metals, Spectrapure Standards, Norway. **** VHG certified NIST-traceable multi element aqueous standard, VHG Labs, Inc (LGC standards), USA. In case of Ag, TiO 2 and CeO 2 ENP suspensions the digestion procedure was carried out in Teflon vessels. For the Au ENP suspensions glass vials were used to avoid possible interaction with the Teflon surfaces. In case of ZnO, after testing both materials, also Teflon vials were chosen due to lower blank values and better recoveries. For ICP-MS measurements digested samples were transferred to polypropylene centrifuge tubes (VWR, Germany) or, in case of Au, to Rotilabo -screw neck ND24 glass vials (Carl Roth, Germany). 3

Table S3. Parameters of ICP-QMS analysis Isotopes of the elements analyzed and the respective limits of detection (LoD; blank + 3 sigma) and limits of quantification (LoQ; blank + 10 sigma; acidic and aqueous matrices). Collision cell modus, [He], was conducted at a helium gas flow of 3 ml/min. Certified concentrations of the reference materials (CRM) used for method validation are given for each element. Ag [µg/l] Ti [µg/l] Ce [µg/l] Zn [µg/l] Au [µg/l] Isotope 107 Ag 47 Ti [He] 140 Ce 66 Zn [He] 197 Au Matrix acid water acid water acid water acid water acid water LoD 0.26 0.21 0.71 0.18 0.21 0.21 1.0 0.1 0.35 - LoQ 0.67 0.61 1.73 0.49 0.64 0.64 2.29 0.18 0.93 - CRM TMDA 52.3 TMDA 52.3 SPS-SW2 TMDA 52.3 Noble metals TM 27.3**: 2.01 ± 0.26 µg/l TM 27.3**: 16.2 ± 2.6 µg/l ** Certified Reference Waters for Trace Elements, Environment Canada (see Table S2). 4

Results and discussion Fig. S1. TEM-images of nanoparticles suspensions Ag TiO 2 20 nm 20 nm CeO 2 ZnO 20 nm 20 nm Au 10 nm Au 200 nm 20 nm 100 nm 5

Centrifugation: calculation of the run time The time needed for sedimentation of the silver nanoparticles was calculated in accordance to Griffith 2010 [2] and the information given in the users manual of the rotor (TH-641, Thermo Scientific, Germany). The sedimentation time was estimated as follows: The time (T) required for sedimentation of a particle to the bottom of the tube is defined by the ratio of the clearing factor of the rotor (K) and the sedimentation coefficient (S) of the particles (Eq.1): K T = Eq.1 S The K-Factor describes the relative pelleting efficiency (sedimentation of particles to the bottom of the tube) of the rotor and can be calculated as followed (Eq.2): K = 2 rmax rotor speed ( 253 000) ln r min, Eq.2 1,000 The rotor speed was set to 41,000 rpm, the maximum and minimum distance between particle and the center of rotation (r max and r min ) are determined by the rotor (TH-641, Thermo Scientific, Germany) and the length of the tubes: r max = 7.19 cm r min = 15.32 cm The sedimentation coefficient was calculated in accordance to the following equations (Eq. 3 & Eq. 4): v S = ω 2 r Eq.3 v = sedimentation velocity of the particle [cm/s] ω = rotor speed in [rad/s] 2rpm ω = ; rpm = 41000, rpm = 41, 000 60 6

d v = 2 ( ρp ρl) g 18 µ Eq.4 d = diameter of the particle [cm] ρ P = density of the particle ρ L = density of the liquid = 1 g/cm 3 µ = viscosity of the liquid medium = 1.52 x 10-3 Pa s g = gravitational force; = 13.43 x 10 6 m/s² g = ω 2 r The time required for the sedimentation of a 50 nm Ag particle in a tube of approximately 8 cm was ~1.52 days (36.5 hours, 41,000 rpm). Since particle size distribution of the Ag ENP suspension showed a certain polydipersity (refer to results and discussion). Hence, the centrifugation time was prolonged to 48 hours to ensure the sedimentation of smaller particles. Moreover, only the upper ~1 cm from the surface of the liquid within the centrifugation tube was sampled. 7

Fig. S2. Time dependant dissolution during dialysis Dissolution of Ag + from Ag ENP suspension of three samples (diamond, square and triangle) over a period of 29 days. 80 70 Dissolved silver fraction [%] 60 50 40 30 20 10 0 0 5 10 15 20 25 30 35 Time [d] 8

Calibration and results of the standard addition in ion selective electrode measurments Table S4. Calibration of the silver ion selective electrode was conducted within a concentration range of 0.1 mg/l to 100 mg/l (values measured) Concentration log (Concentration) Voltage [mv] Ag [mg/l] log(ag) U [mv] 0.1-1.00 261 0.2-0.70 266 0.5-0.30 278 1 0.00 301 2 0.30 317 5 0.70 341 10 1.00 359 20 1.30 376 50 1.70 398 100 2.00 413 450 400 U [mv] 350 300 y = 53.969x + 304.02 R 2 = 0.9909 250 200-1.00-0.50 0.00 0.50 1.00 1.50 2.00 2.50 log (Konz Ag) Fig. S3. Calibration curve of ISE 9

Table S5. Prior to further measurements, the response of the electrode was tested by a standard addition procedure. A Ag ENP working suspension (WS 1:10,000 dilution of the stock suspension) was spiked with a ICP element standard solution of different concentrations (see below). The concentration of dissolved silver determined by ISE was calculated on basis of the equation of the calibration curve. After blank correction, the recoveries were calculated on the basis of the concentrations of the Ag element standard added Voltage Concentration Blank correction Recovery U [mv] Ag + [mg/l] [%] WS + 0 mg/l Ag (blank) 272 0.26 WS + 1 mg/l Ag 309 1.24 0.98 98.16% WS + 2 mg/l Ag 321 2.06 1.81 90.43% WS + 5 mg/l Ag 342 5.06 4.80 96.00% WS + 10 mg/l Ag 359 10.44 10.19 101.86% WS + 20 mg/l Ag 375 20.66 20.41 102.04% WS + 50 mg/l Ag 396 50.62 50.36 100.73% References 1. Lewis, D.J., et al., Luminescent nanobeads: attachment of surface reactive Eu(III) complexes to gold nanoparticles. Chemical Communications, 2006(13): p. 1433-1435. 2. Griffith, O.M., Practical Techniques for Centrifugal Separations. Thermo Fisher Scientific; Application guide, 2010. 10