Thermocouple TC-K Sensor 0 C to 1200 C

Similar documents
Temperature Sensor -40 C to 140 C

10 samples per second

Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

Have a look at the following video which shows an invention developed in the High-Low Tech Lab at MIT.

Chemistry MultiMeasure Sensor PS-2170

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Spectrometer User s Guide

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

IR/Thermistor Pen. Instruction Manual

CR10TCR THERMOCOUPLE REFERENCE

Rotary Motion Sensor

WeatherHub2 Quick Start Guide

ph Probe ReallyEasyData com

Instruction Manual. Qubit Fluorometer. probes.invitrogen.com/qubit

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

CR10XTCR THERMOCOUPLE REFERENCE

for MiLAB Desktop Experiments in Physics imagine explore learn

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Today s Weather 24 Hour Forecaster

O P E R A T I N G M A N U A L

CR10XTCR THERMOCOUPLE REFERENCE

473-SHX Dew Point Mirror

K D A A M P L I F I E R S F I R M W A R E U S E R G U I D E

XR Analog Clock - Manual Setting Model Troubleshooting Guide

6.Ebz!boe!8.Ebz!!! Gpsfdbtufst!!! G U I D E n catio Lo

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.

Quantum Series Product Catalog

MODEL 107 TEMPERATURE PROBE INSTRUCTION MANUAL

MEASUREMENT: PART II

LEE Project Room AH177

PiCUS Calliper Version 3

566/568. Infrared Thermometers. Getting Started

Experiment C-15 Distillation - part 1

Activity 1: Investigating Temperature

THERMOCOUPLE CHARACTERISTICS TRAINER

473 Dew Point Hygrometer

VIBRATION METER. Instruction Manual.

Orbit Support Pack for Excel. user manual

Chemistry 1. Worksheet 4. Temperature in Chemistry. 1 MathTutorDVD.com

Bante210 Benchtop ph Meter Instruction Manual

473 Dew Point Hygrometer

personal weather station

Hadrons Desktop U.S. Atomic Clock & Weather Station

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

Assembly and Operation Manual. April 2016

How to Make Photometric & Colorimetric Measurements of Light Sources using an Ocean Optics Spectrometer and SpectraSuite Software

Experiment P-5 Motion of a Cart on an Inclined Plane

Ramberg-Osgood Convertor. User Manual

Lightcloud Application

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

Experiment C-10 Titration of a Strong Acid and a Strong Base

Small Gage Pressure Sensor

Developing a Scientific Theory

Medium Pressure Sensor Analog Output

PTA-427 BAROMETRIC PRESSURE TRANSDUCER OPERATOR S MANUAL

THERMAL RADIATION. The electromagnetic radiation emitted by a hot tungsten filament will be studied.

ISSP User Guide CY3207ISSP. Revision C

FIELD SPECTROMETER QUICK-START GUIDE FOR FIELD DATA COLLECTION (LAST UPDATED 23MAR2011)

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

Lab Activity H4 It s Snow Big Deal

TG646 WEATHER STATION

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

Small, Gauge Pressure Sensor

Minimum (-31) every 10 s -35 (-31)

Low Pressure Sensor Amplified Analog Output SM6295-BCM-S

U.S. Atomic Clock & Weather Station. Instruction Manual

What is a WQSensor? Software Installation. Uninstalling WQSensors Software. NexSens Technology, Inc. TABLE OF CONTENTS

Software BioScout-Calibrator June 2013

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

Mini Environmental Quality Meter

Account Setup. STEP 1: Create Enhanced View Account

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

X: The Hall Effect in Metals

RainMachine Mini- 8 Quick- Start Guide

PDF-2 Tools and Searches

Electricity and magnetism. Verifying the Lenz Law by measuring the electric current flowing through a coil created by an external magnetic field

INSTRUCTION MANUAL ANALOG COLORIMETER

3WHB10K 3-WIRE HALF BRIDGE TERMINAL INPUT MODULE INSTRUCTION MANUAL

Small Absolute Pressure Sensor

CHEMISTRY 170. Radioisotopes

LABORATORY INVESTIGATION

OEM Silicon Pressure Die

Rapid RH Portable ph Meter. User's Manual

Newton's Laws and Atwood's Machine

Kinetics of Crystal Violet Bleaching

Ocean Optics Educational Spectrometers. Getting Started Manual

Experiment 1 Solutions: Equipotential Lines and Electric Fields

Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer.

Biot-Savart Law Performing various measures to study the magnetic field intensity variations around an inducting coil

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

INSTRUCTION MANUAL. CR10XTCR Thermocouple Reference. Revision: 1/03. Copyright (c) Campbell Scientific, Inc.

Enhanced Mapping. RP Data Professional. What you will learn in this guide. CoreLogic RP Data Professional Getting Started Guide Series

Measurements & Instrumentation. Module 3: Temperature Sensors

Acid-Base ph Titration Introduction

ph 5 Meter Manual The LaMotte 5 Series

Transcription:

imagine explore learn Thermocouple TC-K Sensor 0 C to 1200 C Product Number: ENTMP025 Overview The Thermocouple Type K (TC-K) sensor is a high temperature sensor with a range of 0 C to 1200 C. It is extremely accurate and boasts a rapid response time. The TC-K sensor is mainly used for high temperature measurements, monitoring chemical processes that occur in high temperatures or even measuring ovens. The high accuracy and reliability of this sensor makes it an excellent tool for advanced Chemistry experiments. The Temperature TC-K sensor can be connected to all types of einstein data loggers. Typical experiments Chemistry Exploring the temperature of a candle flame Different boiling points of various solutions Melting points of certain solids

T h e r m o c o u p l e TC- K 2 How it works A thermocouple consists of two long wires made of different metals connected at one end while at the other end they are close to each other but without making contact. When the connected end of the thermocouple is placed in a higher temperature than the unconnected end, voltage is produced between the wires. In order to correct for room temperature, another temperature sensor is built into the thermocouple. The adjusted voltage is then amplified and adjusted to a range of 0-3 V. The result is then displayed and recorded. Sensor specification Range: 0 C to 1200 C 32 F to 2192 F 273.15 K to 1473.15 K Accuracy: ±2 % over entire range Resolution (12-bit): 0.3 C 0.55 F Default Sample Rate: samples per second Recommended Sensor Usage: Resistant to mild chemical solutions Do not place the sensor's cable in liquid Data logging and analysis MiLAB 1. Take your einstein Tablet OR pair your einstein LabMate with your Android or ios tablet via Bluetooth 2. Insert the sensor cable into one of the sensor ports 3. Launch MiLAB 4. MiLAB will automatically detect the sensor and show it in the Launcher View 5. Make sure the icon next to the sensor is checked ( ) to enable it for logging 6. Tap Settings to switch between measuring in Celsius, Fahrenheit and Kelvin

T h e r m o c o u p l e TC- K 3 MiLAB Desktop 1. Pair your einstein LabMate with your PC, MAC, or Linux machine via Bluetooth, or connect it via the USB cable (found in the einstein LabMate box). 2. Insert the sensor cable into one of the sensor ports 3. Launch MiLAB 4. MiLAB will automatically detect the sensor and show it in the Current Setup Summary window 5. Click Full Setup, located at the bottom of the Current Setup Summary window to program the data logger s sample rate, number of samples, units of measurement, and other options 6. Click the Run button ( )on the main toolbar of the Launcher View to start logging Calibration The Temperature TC-K sensor is shipped fully calibrated.

T h e r m o c o u p l e TC- K 4 An Example of using the Thermocouple Sensor Exploring a Flame The heat of a flame is not uniform. Zones within a flame have differing temperatures. These zones can be mapped utilizing the thermocouple s high-sensitivity, fast reaction times and ability to withstand high temperatures. The following graph shows the temperature in three different zones of the candle flame. Figure 1: The temperature in three different zones of the candle flame Troubleshooting If the Temperature Sensor isn't automatically recognized by MiLAB, please contact Fourier Education's technical support. Technical support For technical support, you can contact the Fourier Education's technical support team at: Web: /support Email: support@fourieredu.com Phone (in the US): (877) 266-4066 Copyright and Warranty All standard Fourier Systems sensors carry a one (1) year warranty, which states that for a period of twelve months after the date of delivery to you, it will be substantially free from significant defects in materials and workmanship. This warranty does not cover breakage of the product caused by misuse or abuse.

T h e r m o c o u p l e TC- K 5 This warranty does not cover Fourier Systems consumables such as electrodes, batteries, EKG stickers, cuvettes and storage solutions or buffers. ALBERT EINSTEIN and EINSTEIN are either trademarks or registered trademarks of The Hebrew University of Jerusalem. Represented exclusively by GreenLight. Official licensed merchandise. Website: einstein.biz Fourier Systems Ltd. All rights reserved. Fourier Systems Ltd. logos and all other Fourier product or service names are registered trademarks or trademarks of Fourier Systems. All other registered trademarks or trademarks belong to their respective companies.