EFFECTS OF MOBILE PHASE COMPOSITION ON THE SEPARATION OF CATECHOLAMINES BY LIQUID CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION

Similar documents
High Pressure/Performance Liquid Chromatography (HPLC)

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers.

High Performance Liquid Chromatography

LUMEFANTRINUM LUMEFANTRINE

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

ANALYTICAL METHOD PROCEDURES

Appendix II- Bioanalytical Method Development and Validation

ARTEMETHER AND LUMEFANTRINE ORAL SUSPENSION:Final text for addition to The International Pharmacopoeia (November 2008)

ARTEMETHER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008)

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Shodex TM ODP2 HP series columns

ProPac WCX-10 Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Acclaim Mixed-Mode WCX-1

Department of Civil and Environmental Engineering, Stanford University, 473 Via Ortega, Stanford, California 94305, United States

column If you would like a subscription, or more information, please contact your nearest Waters Office.

H 3 CO H 3 CO S CH 3

637. Thiamethoxam. HPLC method

Development and Validation of a HPLC Method for Chlorphenamine Maleate Related Substances in Multicomponents Syrups and Tablets

DEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR IN-VIVO STUDY OF DICLOFENAC POTASSIUM

High Performance Liquid Chromatography

Cation Exchange HPLC Columns

Comprehensive Neurochemical Profiling of Brain Tissue Samples

The Theory of HPLC. Ion Pair Chromatography

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

CIPAC. CIPAC Free relevant impurities methods:

for Acclaim Mixed-Mode WCX-1

Liquid Chromatography

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Supporting Information

Determination of Caffeine by HPLC

for Acclaim Trinity TM P1

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

GFC separation of water-soluble polymers with TSKgel PW-type columns (2) using the PWXL series. Contents

It s hot! ZIC -chilic

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Instrumental Chemical Analysis


VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Chapter content. Reference

Reversed Phase Solvents

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Packings for HPLC. Packings for HPLC

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC

LC and LC/MS Column Selection Flow Chart

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Chromatography. Gas Chromatography

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

penta-hilic UHPLC COLUMNS

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE

Ondansetron Hydrochloride Tablets

INDIGOTINE. Disodium 3,3'-dioxo-[delta 2,2' -biindoline]-5,5'-disulfonate (principal component) (principal component)

Biochemistry. Biochemical Techniques HPLC

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

TECHNICAL BRODIFACOUM

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

Pharmacophore 2011, Vol. 2 (4), ISSN Pharmacophore. (An International Research Journal)

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Dionex IonPac AS28-Fast-4µm column

Analytical Chemistry

Determination of Trace Cations in Power Plant Waters Containing Morpholine

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003

Dilution(*) Chromatography

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

Ion Chromatography (IC)

with diode array detection

Chapter 23 Introduction to Analytical Separations

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

8. Methods in Developing Mobile Phase Condition for C18 Column

Determination of Iodate by HPLC-UV after On-Line Electrochemical Reduction to Iodide

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form

Luminescence transitions. Fluorescence spectroscopy

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

FAST ANALYSIS OF GABA AND GLUTAMATE

HPLC Background Chem 250 F 2008 Page 1 of 24

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

penta-hilic UHPLC COLUMNS

TECHNICAL TEMEPHOS. 1. Specification. Full specification WHO/SIT/19.R4 Revised 10 December Description

Determination of trace anions in concentrated hydrofluoric acid

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

Too Polar for Reversed Phase What Do You Do?

DEVELOPMENT AND VALIDATION OF NEW RP-HPLC METHOD FOR THE DETERMINATION OF AFLOQUALONE IN HUMAN PLASMA AND FORMULATION

Retention Behavior of p-alkylphenols in Reversed-Phase Liquid Chromatography Using Ethanol/Water Mixtures

Volume 6, Issue 2, January February 2011; Article-015

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

IMPROVED CHROMATOGRAPHIC METHOD FOR DETERMINATION OF SODIUM DICLOFENAC IN INJECTABLE SOLUTION AND PREDICTION OF CHEMICAL STABILITY

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Transcription:

Pharmacology EFFECTS OF MOBILE PHASE COMPOSITION ON THE SEPARATION OF CATECHOLAMINES BY LIQUID CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION A. ISIMER N. E. BASCI A. BOZKURT S. O. KAYAALP SUMMARY: In this study, the effects of ion-pairing agents and other ingredients of mobile phase on the separation of nor adrenaline (NA), adrenaline (A) and dopamine (DA) were studied in reversed-phase high performance liquid chromatography with electrochemical detection. The effects of two ion-pairing agents, hexane-sulphonic acid sodium salt (HSA) and pentane-sulphonic acid sodium salt (PSA), have been compared with widely used octane-sulphonic acid sodium salt (OSA). In phosphate based mobile phase, increasing the concentration of OSA and HSA increased the capacity factors (K) of all catecholamines (CAs) in the standard mixture and higher concentration of HSA was required to reach the same values. PSA had minimal effect on the retention times at the same molar concentration range. In ammonium acetate based mobile phase, increasing the concentration of the ammonium acetate significantly reduced the K values of all CAs when HSA was used as an ionpairing agent. Alteration of the ammonium acetate concentration in PSA containing mobile phase had minimal effect on K values. In contrast to the results obtained with phosphate buffer, increasing the ph of the ammonium acetate based mobile phase resulted in an increase in the K values of all compounds investigated. HSA was found to be a suitable ion-pairing agent for liquid chromatographic separation of CAs in either phosphate or ammonium acetate based mobile phases and the applicability of the method was demonstrated by analysis of CAs in different rat tissues after alumina extraction. Key Words: Catecholamines, liquid chromatography, ion-pairing agents, electrochemical detection. INTRODUCTION Catecholamines (CAs) produce many important physiologic effects in the brain, the cardiovascular system and other organs. The concentration of the major CAs, nor adrenaline (NA), adrenaline (A) and dopamine (DA) in biological tissues is modified by physiological factors and influenced by pharmacological agents. It is therefore essential to be able to elucidate its variation in quantitative chemical tests and in turnover studies. Moreover, plasma and urinary CA levels and their measurements are of From Department of Pharmacology, Gülhane Military Medical Academy, From Department of Pharmacology, Hacettepe University, Medical School, Ankara,Türkiye. clinical importance as a diagnostic tool in clinical chemistry laboratories. Introduction of high performance liquid chromatography/electrochemical detection (HPLC-ED) has shown to offer high selectivity and sensivity for the analysis of CAs and related compounds in complex media (5, 7, 8). Most of the published HPLC-ED methods for determination of these compounds have employed reversed-phase technique and purification procedure via alumina or ion-exchange. Retention of CAs on a reversed-phase column can be manipulated by (i) changing the ph of the mobile phase, (ii) adding a counter ion to the mobile phase to retain a charged molecule of interest, (iii) ion pair extraction or (iv) adding an organic modifier to the mobile phase. Since Journal of Islamic Academy of Sciences 4:2, 130-135, 1991 130

problems with various interferences can be solved in a number of ways, phosphate buffered mobile phases have been investigated in detail (4, 9). Furthermore, addition of an aliphatic sulfonate as a paired ion was necessary to enhance the separation of CAs and especially to achieve the resolution between adrenaline (A) and 3,4-dihydroxybenzylamine (DHBA), a useful internal standard (10). Octanesulfonic acid (OSA) was found to be the paired-ion of choice. One of the alternative mobile phase solutes is ammonium acetate. Recently, Bartlett (2) reported that ammonium acetate system was superior to conventional phosphate based systems for the separation of CAs. The present study was intended to investigate the effects of adding paired ions of varying carbon chain length such as, pentanesulfonic acid (PSA) or hexanesulfonic acid (HSA) and organic modifier, and of altering ph and buffer content of mobile phase on the separation of DOPA, NA, A, DA and DHBA in reversed phase HPLC-ED. MATERIALS AND METHODS Chemicals HPLC-grade acetonitrile was purchased from Fisher Scientific (Pittsburgh, PA, USA). Pentanesulfonic acid sodium salt, hexanesulfonic acid sodium salt, octanesulfonic acid sodium salt, nor-adrenaline, adrenaline, dopamine and 3,4-dihydroxybenzylamine were obtained from Sigma Chemical Co. (St. Louis, MO, USA). All other chemicals were analytical grade. Apparatus The chromatographic system consisted of a Model 6000A solvent delivery system, a Model U6K injector, a Model 730 data module and a µbondapak C 18 reversed-phase stainless-steel analytical column (10 µm particle size, 30 cm x 4.0 mm I.D.) protected with a guard column packed with Bondapak C 18 /Corasil (Waters Assoc. Milford, Mass., USA). Catecholamines were detected using a Waters Model 460 electrochemical detector which was equipped with a glassy-carbon working electrode set at an electrode potential of + 0.6 V versus an Ag/AgCl reference electrode. Standard solutions Catecholamine (NA, A and DA) stock solutions were prepared separately at a concentration of 6 mm in 0.1 N HCl containing 5 mol/l sodium metabisulphite. All solutions were stored in dark at -20 ο C and remained stable for at least one month. A working standard mixture of CAs was prepared daily in mobile phase to contain 0.6 µm of each and an injection volume of 20 µl was employed. Mobile phase preparation Aqueous solutions of 0.1 mol/l sodium dihydrogen phosphate and 0.34 mmol/l EDTA and varying concentrations of acetonitrile and an ion-pairing agent were made up in distilled water. The required ph value was adjusted with phosphoric acid. Another series of experiments were performed with ammonium acetate buffer system, in which mobile phase included 0.25 mol/l ammonium acetate, 0.34 mmol/l EDTA and varying concentrations of acetonitrile and an ion-pairing agent. The mobile was phase buffered with glacial acetic acid to required ph value. The mobile phases were filtered through a 0.45 µm Type HA filter (Millipore, Bedford, MA, USA). Mobile phase flow rate was maintained at 1.0 ml/min through the system. The capacity factor of CAs, K, is defined as follows: K = (t R - t o ) / t o where t R is the retention time of CA and t o is the retention time of void volume of the chromatographic system. Application to biological samples Rats were killed by decapitation and tissues were quickly removed. Weighed tissue samples were homogenized in ice cold 0.4 N perchloric acid containing 0.1% EDTA and 0.1% Na 2 S 2 O 5. Homogenates were centrifuged at 8000 g for 15 min. Supernatants were separated and stored -20 o C. Catecholamines were extracted from thawed supernatant using batch extraction with alumina at alkaline ph which was carried out as previously described (1). A 20 µl of alumina eluent in 0.1 mol/l perchloric acid was injected into the HPLC system. RESULTS AND DISCUSSION Effects of phosphate based mobile phase composition on the capacity factors of catecholamines: Ionic strength of mobile phase is known to significantly affect chromatographic behavior of the CAs in ion-paired reserved-phase chromatography. Moyer and Jiang (10) reported that the retention time was not affected by varying concentrations of phosphate but the electrochemical detector responses of CAs were altered. The optimum responses were obtained with phosphate buffer at a concentration of 0.1 mol/l. Therefore, this concentration was used in all experiments done with phosphate based mobile phase. As shown in Figure 1, increasing concentrations of OSA and HSA increased the K values of all components of the standard mixture. However, higher molar concentrations of HSA was required to reach the same values. In contrast, PSA had minimal effect on the retention times, at the same molar concentration range. The effects of increasing ph on the capacity factors of CAs were shown in Figure 2. No significant change was observed in both HSA and PSA containing mobile phases. Bartlett (2) and Kontur, et al. (6) also showed that increasing the ph (3.5-5.0) of the phosphate buffered mobile phase did not affect the retention time of CAs. Increasing the acetonitrile content of phosphate based mobile phase reduced the K values of CAs in a predictable way regardless of the type of ion-pairing agent used. Effects of ammonium acetate based mobile phase composition on the capacity factors of catecholamines: 131 Journal of Islamic Academy of Sciences 4:2, 130-135, 1991

Figure 1: Effect of increasing the concentration of PSA, HSA and OSA in mobile phase upon the capacity factors (K) of catecholamines. Chromatography was performed on µbondapak C 18 column with a mobile phase of 0.1 mol/l phosphate, 0.3 mmol/l EDTA, 3% (v/v) acetonitril, ph 3.5, flow rate 1.0 ml/min. Figure 2: Effect of increasing ph of phosphate based mobile phase on the capacity factors (K) of catecholamines. Mobile phase consisted of either 1.2 mmol/l PSA or 8.5 mmol/l HSA; other conditions were as described in Figure 1. Journal of Islamic Academy of Sciences 4:2, 130-135, 1991 132

Figure 3: Effect of ammonium acetate concentration of mobile phase on the capacity factors (K) of catecholamines. Mobile phase consist ed or either 8.5 mmol/l HSA or 2.3 mmol/l PSA. A µbondapak C 18 column used with 1% (v/v) acetonitrile, 0.3 mmol/l EDTA and ph 4.5 in a flow rate of 1.0 ml/min. Figure 4: Effect of increasing the concentration of PSA and HSA in mobile phase on the capacity factors (K) of catecholamines. Chromatography was performed on a µbondapak C 18 column with a mobile phase of 0.25 mol/l ammonium acetate, 3% (v/v) acetonitril and ph 4.5 in a flow rate 1.0 ml/min. Increasing the molar concentration of ammonium acetate significantly reduced the K values of all CAs when HSA was used as an ion-pairing agent (Figure 3a). In contrast to this observation, alteration of the ammonium acetate concentration in PSA containing mobile phase had minimal effect on K values (Figure 3b). The effects of increasing concentrations of ion-pairing agents on the separation of CAs were shown in Figure 4. Results obtained with HSA and PSA in ammonium acetate based mobile phase resembled those seen in phosphate based mobile phase. Increasing the acetonitrile content of mobile phase reduced the K values of CAs in a predictable manner regardless of the type of ion-pairing agent used, which was the same in the phosphate based mobile phase. In contrast to the results obtained with phosphate buffer, increasing the ph of ammonium acetate based mobile phase resulted in an increase in the K values of all compounds investigated (Figure 5). Results obtained with phosphate based mobile phase suggested that CAs would be separated independently of ph changes. However, the effects of ph were markedly different when ammonium acetate based mobile phase was used. One explanation of this difference caused by the mobile phase is that ammonium ion could function as a secondary ionpairing agent interacting with stationary phase and with 133 Journal of Islamic Academy of Sciences 4:2, 130-135, 1991

Figure 5: Effect of ammonium acetate mobile phase ph on the capacity factors (K) of catecholamines. Mobile phase consisted of either 2.3 mmol/l PSA or 8.5 mmol/l HSA. Other conditions were as described in Figure 4. amines. This event is dependent on the ph which determines the degree of ionization of ammonium ion. Bartlett (2) also showed that in ammonium acetate based mobile phase, increasing the ph from 4.0 to 5.5 augmented the capacity factors of NA, A and DA. Application to biological samples Alumina extracts of rat adrenal glands were assayed for NA, A and DA. Chromatography was performed upon µbondapak C 18 column (10 µm particle size, 30 cm x 4.0 mm I.D.) with a mobile phase consisting of 0.1 mol/l phosphate buffer, 8.5 mmol/l HSA, 0.34 mmol/l EDTA, ph 3.5 with a flow rate of 1.0 ml/min and a detection voltage of 0.6 volt. As shown in Figure 6, three CAs and internal standard (DHBA) were readily detected and values obtained agreed with results reported in the literature (3). Figure 6: Chromatogram of adrenal gland supernatant. Chromatography was performed on a µbondapak C 18 column with a mobile phase of 0.1 mol/l phoshphate, 3% (v/v) acetonitrile, 8.5 mmol/l HSA and ph 3.5 in a flow rate of 1.0 ml/min. Journal of Islamic Academy of Sciences 4:2, 130-135, 1991 CONCLUSION These observations suggest that HSA is a suitable ion pairing agent to achieve a baseline separation of CAs in both phosphate and ammonium acetate based mobile phases. However, the capacity factors of three CAs calculated at the same HSA concentration (8.5 mmol/l) and the K values for all CAs obtained in phosphate buffer were found to be about 120% higher than those obtained in ammonium acetate based mobile phase. 134

REFERENCES 1. Anton AH, Sayre DF : A Study of the Factors Affecting the Aluminium Oxide-Trihydroxyindole Procedure for the Analysis of Catecholamines. J Pharmacol Exp Ther, 138:360-374, 1962. 2. Bartlett WA : A Comparison and Clinical Applications of Ammonium Acetate and Phosphate Based Mobile Phases for the Separation of Catecholamines on Reversed Phase Columns. J Liq Chromatogr, 8:719-751, 1985. 3. Coulter CL, McMillen C, Browne CA : The Catecholamine Content of the Perinatal Rat Adrenal Gland. Gen Pharmacol, 19:825-830, 1988. 4. Horvath C, Melander W, Molnar I, Molnar P : Enhancement of Retention by Ion-Pair Formation in Liquid Chromatography with Non-polar Stationary Phases. Anal Chem, 49:2295-2305, 1977. 5. Kagedal B, Goldstein DS : Catecholamine and Their Metabolites. J Chromatogr, 429:177-233, 1988. 6. Kontur P, Dawson R, Monjan A : Manipulation of the Mobile Phase Parameters for the HPLC Separation of Endogenous Monoamines in Rat Brain Tissue. J Neurosci Meth, 11:5-18, 1984. 7. Krstulovic AM : Investigations of Catecholamine Metabolism Using High Performance Liquid Chromatography. Analytical Methodology and Clinical Application. J Chromatogr, 229:1-15, 1982. 8. Mefford IN : Application of High Performance Liquid Chromatographic-Electrochemical Detection to Neurochemical Analysis: Measurement of Catecholamines, Serotonin and Metabolites in Rat Brain. J Neurosci Meth, 3:207-215, 1981. 9. Molnar I, Horvath C : Reversed-Phase Chromatography of Polar Biological Substances : Separation of Catechol Compounds by High-Performance Liquid Chromatography. Clin Chem, 22:1497-1502, 1976. 10. Moyer TP, Jiang N : Optimized Isocratic Conditions for Analysis of Catecholamines by High-Performance Reversed- Phase Paired-Ion Chromatography with Amperometric Detection. J Chromatogr, 153:365-372, 1978. Correspondence: Askin Isimer Gülhane Military Medical Academy, Department of Pharmacology, Etlik, 06018 Ankara, TÜRKIYE. 135 Journal of Islamic Academy of Sciences 4:2, 130-135, 1991