Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Similar documents
Figure 1. Decay Scheme for 60Co

ORTEC AN34 Experiment 10 Compton Scattering

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Scintillation Detector

ORTEC Experiment 19. Gamma-Ray Decay Scheme and Angular Correlation for 60 Co. Equipment Required. Purpose

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

LAB 4: Gamma-ray coincidence spectrometry (2018)

3. Perturbed Angular Correlation Spectroscopy

1 of :32

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

THE COMPTON EFFECT Last Revised: January 5, 2007

Gamma ray coincidence and angular correlation

The Mössbauer Effect

Mass of the electron m 0

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

Gamma Spectroscopy. References: Objectives:

Rice University Physics 332 LIFETIME OF THE MUON I. INTRODUCTION...2! II. MEASUREMENT PROCEDURES...3! III. ANALYSIS PROCEDURES...7!

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

MEASURING THE LIFETIME OF THE MUON

GAMMA RAY SPECTROSCOPY

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

Decay of the First Excited State at 13.3 kev in 73Ge

Multi Channel Analyzer (MCA) Analyzing a Gamma spectrum

Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

COMPTON SCATTERING OF GAMMA RAYS

Radiation Detection. Laboratory & Computational Physics 2. Last compiled March 2, Constructed from legacy notes with amendments by Innes Bigaran

Foundations of Modern Physics by Tipler, Theory: The dierential equation which describes the population N(t) is. dn(t) dt.

ORTEC. Time-to-Amplitude Converters and Time Calibrator. Choosing the Right TAC. Timing with TACs

Experiment 6 1. The Compton Effect Physics 2150 Experiment No. 6 University of Colorado

Gamma Spectroscopy. Calligaris Luca Massironi Andrea Presotto Luca. Academic Year 2006/2007

Absolute activity measurement

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

arxiv: v1 [physics.ins-det] 3 Feb 2011

PHYSICS 359E: EXPERIMENT 2.2 THE MOSSBAUER EFFECT: RESONANT ABSORPTION OF (-RAYS

AGATA preamplifier performance on large signals from a 241 Am+Be source. F. Zocca, A. Pullia, D. Bazzacco, G. Pascovici

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

Detection and measurement of gamma-radiation by gammaspectroscopy

Radiation Detection. Laboratory & Comp. Physics 2

dn(t) dt where λ is the constant decay probability per unit time. The solution is N(t) = N 0 exp( λt)

Experiment 27 Positron Annihilation Lifetime Spectrometry

ORTEC Experiment 7. High-Resolution Gamma-Ray Spectroscopy. Equipment Required. Purpose. Introduction

Gamma Ray Spectroscopy

Analysis of γ spectrum

Fig. 1b: Transition intensities Iγ for the β decay of 181Hf (From: R. Firestone, Table of Isotopes, 8th edition, 1996).

K 40 activity and Detector Efficiency

SCINTILLATION DETECTORS AND PM TUBES

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

Positron-Electron Annihilation

K 40 activity and Detector Efficiency

Gamma-ray spectroscopy with the scintillator/photomultiplierand with the high purity Ge detector: Compton scattering, photoeffect, and pair production

Gamma Ray Spectroscopy, Using NaI(Tl) Detectors. Department of Physics The University of Hong Kong

Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

Quality Assurance. Purity control. Polycrystalline Ingots

Measuring the Muon Lifetime

W. Udo Schröder Departments of Chemistry & of Physics and Astronomy

Compton Imaging with Coincidence Measurements for Treaty Verification Purposes

Application of positrons in materials research

Measurement of Compton Scattering

PHY 192 Compton Effect Spring

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

γ-γ Coincidence in 22 Na

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Measurement of Mean μ-lifetime

ACCURATE MEASUREMENTS OF SURFACE EMISSION RATE FOR LARGE-AREA ALPHA AND BETA REFERENCE SOURCES

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Energy loss of alpha particles - Prelab questions

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

Alpha-particle Stopping Powers in Air and Argon

Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging

High Purity Germanium Detector Calibration at ISOLDE

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

RANGE OF ALPHAS. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

AN34 Experiments in Nuclear Science Laboratory Manual Fourth Edition

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools

CHAPTER-II Experimental Techniques and Data Analysis (Positron annihilation spectroscopy)

Gamma-Ray coincidence and 60 Co angular correlation

Application of NaI(T1) Scintillation Detector to Measurement of Tritium Concentration*

Measurement of Compton Scattering

NUCL 3000/5030 Laboratory 2 Fall 2013

BUREAU INTERNATIONAL DES POIDS ET MESURES

Preparatory experiments for cold-neutron induced fission studies at IKI

Positron Annihilation Spectroscopy

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

Received October 7, 1963

He-3 Neutron Detectors

Detectors for 20 kev 10 MeV

Review of Particle Properties: ( ). See the review section on Cosmic Rays under Astrophysics and Cosmology.

Radiation Signals and Signatures in a Detector (Gamma spectroscopy) Sangkyu Lee

The Kinematics and Electron Cross Sections of Compton Scattering

Random Coincidence between two Independent Pulses

Radioactivity. is related to de/dx. The range, R, is defined by the integral of de/dx:

Stability and Characteristics of Large CZT Coplanar Electrode Detectors

DUNPL Preliminary Energy Calibration for Proton Detection

arxiv: v1 [physics.ins-det] 14 Nov 2017

Measuring Radiation: An Introductory Discussion

Louis Baum University of Michigan, REU Student Summer UM Nuclear Sciences Group

arxiv: v2 [physics.ed-ph] 23 Jan 2018

Sample Spectroscopy System Hardware

Transcription:

Nuclear Lifetimes Theory The measurement of the lifetimes of excited nuclear states constitutes an important experimental technique in nuclear physics. The lifetime of a nuclear state is related to its width, (energy), by the uncertainty principle: E t = ---------- (Eq. 1) where E = uncertainty in energy associated with a state, t = uncertainty in time associated with the state, = 1.054 x 10 34 joules-s. In general, for nuclear lifetimes, Eq. (1) becomes τ = Γ ---------- (Eq. 2) Where τ = mean life of a level of width Γ. This experiment will use the coincidence method of timing identification to measure the mean lifetime in the decay scheme of 57 Co. The decay scheme for 57 Co is shown in Figure 1a. The decay of this isotope is essentially all by electron capture, (EC), to the 136 kev level of 57 Fe. Figure 1b shows a high-resolution x-ray spectrum of 57 Co, in which the K α1 and K β1 x-rays resulting from the electron capture are shown. The decay of the 136 kev level of 57 Fe can occur by one of two principal modes: by a 136 kev gamma directly to the ground state or by branching through the 14 kev level to ground state. 57 Co 270d 57 Fe Kα1 6.4 kev EC 99.8% 136 kev 11% γ 3 14 kev 0 57 Fe 97% γ 2 γ 1 98 ns Counts/Channel (Relative) K β1 7.058 kev γ = 14.41 kev 1 1 st excited state of 57 Fe (a) Figure 1: (a) Decay Scheme of 57 Co Channel No. (Relative) (b) (b) Low-Energy Photon Spectrum from 57 Co Nuclear Lifetimesv5.doc (July 2008) Page 1

The 136 kev gamma, (γ 3 ), branch occurs 11% of the time. The 122 kev gamma, (γ 2 ), is 87% abundant. The 14 kev level, (γ 1 ), de-excites most of the time by internal conversion. The ratio of internal conversion to gamma decay, (e/γ), for this level is ~9.0. Figure 2 shows a high-resolution gamma spectrum of a 57 Co source. The lifetime of the 14 kev state can be measured by determining the time distribution of coincidence events between γ 2 and γ 1. The accepted value for this lifetime is 98 ns. Figure 2: High -Resolution Gamma Spectrum for 57 Co Experimentally the best way to do this delayed coincidence experiment is with a time-to-amplitude converter (TAC). In this experiment, γ 2 will be used to start a time measurement, and γ 1 will be used to stop the measurement. The output of the TAC will then provide a time distribution of the lifetime of the first excited state of 57 Fe, calibrated with known delays. Nuclear Lifetimesv5.doc (July 2008) Page 2

Experiments I Measurement of gamma spectra Use the 2 2 inch NaI detector to collect a gamma spectrum of the 60 Co source. The figure shows the set-up using the detector, high voltage supply (1000 V for both detectors used here), preamplifier, main amplifier and MCA (Multi-Channel Analyzer - a PC card). Observe the preamplifier and main amplifier pulses with the oscilloscope. The spectra show two peaks, at 1175 and 1333 kev. Print the spectrum, and identify the peaks. Replace the 60 Co source with the 57 Co source and repeat the procedure. SOURCE 905 3 NaI(Tl) SCINTILLATOR AND PHOTOTUBE 266 PM BASE Dynode 113 PREAMPLIFIER 575A AMPLIFIER MCA SYSTEM 556 HV POWER SUPPLY Figure 3: Electronic Block Diagram for Gamma-Ray Spectroscopy System with NaI(Tl) Detector Next, use the thin window NaI detector to collect the 14.4 kev gamma spectrum from the 57 Co source. Compare the 57 Co spectra with the spectra shown on Figures 4a and 4b. Fig. 4a shows a typical spectrum of 57 Co as it will appear at the output of the amplifier connected to the NaI (TI) 2x2 inch detector. Note that the 122 kev and 136 kev lines are not resolved in the spectrum as they were when taken with an HPGe detector as shown in figure 2. Figure 4: (a) Spectrum of 57 Co taken with 2x2 inch NaI(Tl) Detector. (b) Spectrum of 14.4 kev Gamma from 57 Co taken with Thin-window NaI(Tl) Detector. Nuclear Lifetimesv5.doc (July 2008) Page 3

II Measurement of the time resolution of the system 556 HV POWER SUPPLY 266 113 575A 551 PM BASE PREAMPLIFIER AMPLIFIER TIMING SCA 905 3 NaI(Tl) SCINTILLATOR SOURCE AND PHOTOTUBE Direct 480 PULSER Start 56 TIME-TO- AMPLITUDE CONVERTER TAC ACE-2K MCA SYSTEM 905 1B Attenuated Stop NaI (Thin window) PHOTOTUBE 266 113 575A 551 PM BASE PREAMPLIFIER AMPLIFIER TIMING SCA 556 HV POWER SUPPLY Figure 5: Electronics for Lifetime Measurement with TAC. Figure 5 shows the electronics that will be used for this experiment. In order to measure the time resolution, the detectors high voltages are switched off so that only the split (and therefore coincident) pulses from the pulser are used. The timing SCA (Single Channel Analyzer) puts out both a +5 V slow pulse and a -0.8 V fast pulse each time the SCA records an event. For timing experiments with a TAC (Time-to- Amplitude Converter), the fast negative pulse is always used. The TAC is essentially a fast electronic stopwatch. We provide it with a start pulse to start its timing sequence and a stop pulse to stop its sequence. The time difference between the start and stop pulses is T. The TAC gives us an output that is proportional to T. In other words, if T = 1 µsec, the output of the TAC might be a 1 V pulse. If T 2 = 2 µsec, the TAC would give a 2 V pulse, etc. If we then consider what the TAC does, it not only says that two events are in coincidence, but it also tells us how these coincidences are distributed with respect to time. The full-scale range of the TAC can be set from 50 nanoseconds to several milliseconds from the front panel. As we will see, for many applications, it is the best way to do coincidence spectroscopy. Nuclear Lifetimesv5.doc (July 2008) Page 4

Procedures 1. Set up the electronics as shown in Figure 5 but without the leftmost column, because here only pulser signals are used. Turn on the pulser and adjust its height and the gain of each amplifier so that the pulses observed at the unipolar output of the amplifier are about 3.7 volts high, as shown in Figure 6. Figure 6: Typical bipolar amplifier output observed with an oscilloscope. 2. Connect the bipolar outputs of the amplifiers to the respective timing SCA inputs. 3. For both SCA modules, turn the upper level control to the maximum value and the lower level control to its minimum value. 4. Connect the oscilloscope to the positive outputs of both SCA modules. 5. Observe the 5V logic pulse output of the SCA and slowly increase the lower level control until the signal suddenly disappears. Note this knob reading and turn the knob to a value 0.1 V (100/1000 div) smaller than the noted reading. 6. Continue to observe the same output and slowly decrease the value in the upper level control until the signal disappears again. Note this knob reading and turn the knob to a value 0.1 V (100/1000 div) larger than the noted reading. 7. Repeat steps 4 to 6 for the other SCA. 8. Set the delay on each SCA to minimum (100 nanoseconds). Feed the fast negative output of the SCA from the 2x2 inch detector to the start connector of the TAC, and the other one to the stop connector. Set the TAC at a full-scale time range of 500 nsec. The gate should be in anticoincidence. 9. Connect the scope to the TAC output. Adjust the delay on the Stop circuit SCA until the output pulses from the TAC are about 6 volts. Connect this signal to the MCA input and collect a spectrum of these pulses. Record the channel number of the peak and determine the number of counts in the peak for a 5 minute run. Also record the full width at half maximum of the peak (FWHM). 10. Repeat this measurement for different settings of the stop SCA delay (200, 250, 300 and 350 nanoseconds.) Use the oscilloscope to measure the delay accurately. Nuclear Lifetimesv5.doc (July 2008) Page 5

11. Make a plot of delay (y axis) versus the channel number of the peak in the TAC. The slope of the curve is the calibration in nanoseconds/channel for the TAC settings. In order to measure the time resolution of the pulser peak, multiply the FWHM of the peak by the slope of the delay versus pulse height curve. This calculation should be done for each pulser peak that is observed. III Lifetime measurement of the 14.4 kev state in 57 Fe Procedures Set up the electronics as shown in figure 5. The 905-3 2x2 inch NaI (TI) detector will be used to detect the γ 2 events at 122 kev and to start a time measurement for each sensed event. The other thin window NaI (TI) detector will be used to detect the γ 1 events at 14.41 kev and to stop the time measurements. 1. Turn on the high voltage power supply to 1000 volts for each detector. 2. Reset both SCA lower level controls to 0, the upper level to maximum and the delay to minimum. 3. Set the gain of both amplifiers to the recommended values shown on the apparatus. 4. Connect the unipolar output of the amplifier (from the 2x2 inch detector) to the MCA and collect a gamma spectrum for the 122 kev and 136 kev energies. 5. Take note of the channel number, X 1, at the valley which lies between the 122 kev photopeaks and the Compton edge. Also note the other channel, X 2, at the end of the 136 kev line. 6. Switch off the high voltage supply and use the pulser to set the window of the SCA for this START circuit. The lower level threshold will be set at X 1 while the upper level threshold will be set at X 2. 7. Next, connect the MCA to the output of the other amplifier and collect a gamma spectrum for the 14.4 kev peak. Note the channels before and after the photopeak as these will be used to set the lower and upper threshold for the other SCA. 8. Switch off the high voltage and use the pulser to set the window of this SCA for the STOP circuit. 9. Set the delay of the Start circuit to be 100ns and the delay of the Stop circuit to be 200ns. 10. Turn on the high voltage supply, switch off the pulser and connect the TAC output to the MCA. 11. Accumulate a spectrum for > 15 hours. 12. Save the spectrum as an ASCII file. 13. Use EXCEL to open the file and process the data. Nuclear Lifetimesv5.doc (July 2008) Page 6

Figure 7 shows the results of a typical measurement that was made for this experiment. In order to smooth out the distribution, groups of ten channels were averaged and plotted. The slope of the delay versus channel number for Figure 7 was 0.73 ns/channel. The lifetime of the state is therefore the product of the number of channels for half intensity times the 0.73 ns/channel. Using the data presented in Figure 7, we obtain a lifetime of ~95 ns, which is quite close to the accepted value of 98 ns. Figure 7: Mean lifetime calculation Nuclear Lifetimesv5.doc (July 2008) Page 7