Analysis of Plasticizer Contaminants in Beverages and Milk using an Automated System Based on Turbulent-flow Chromatography Coupled to LC-MS/MS

Similar documents
Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Determination of urea in ultrapure water by IC-MS/MS

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

Laszlo Hollosi, Hamide Senyuva, Klaus Mittendorf, Thermo Fisher Scientific, Dreieich, Germany. Sample + IS. Extraction/Derivatization

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Method of determination of phtalates in spirituous beverages by gaschromatography/mass

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

Application Note. Authors. Abstract. Xin Sun Shandong Agriculture University, Taian, , China

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Fast methods for the determination of ibuprofen in drug products

HILIC Method Development in a Few Simple Steps

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Rapid, sensitive, and easy UHPLC-MS/MS analysis of fungicides in fruit juices with QuEChERS

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Tecan AC Extraction Plate

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Determination of trace anions in concentrated hydrofluoric acid

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

High-Resolution Accurate-Mass (HRAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo Fisher Scientific, San Jose, CA, USA

of mass spectrometry

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

Thermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method

Targeted Screening of Fungal and Plant Metabolites in Wheat, Corn, and Animal Feed Using Automated Online Sample Preparation Coupled to Orbitrap LC-MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Determination of Trace Cations in Power Plant Waters Containing Morpholine

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges

LC-MS/MS Analysis of Phytocannabinoids and their

Conc n of A OAs present (um) Conc n of B OAs present (um)

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Increasing Selectivity and Confidence in Detection when Analyzing Phthalates by LC-MS/MS

Comprehensive Neurochemical Profiling of Brain Tissue Samples

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

[ Care and Use Manual ]

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

Sulfotepp impurities in Chlorpyrifos EC formulations

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Psychoactive Drugs Urine LC-MS/MS Analysis Kit User Manual

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS

The key to your laboratory s success

Test method for the determination of NDMA and NDEA by LC-MS/MS in Sartan containing film coated tablets

Confirmation and Quantitation of THC in Oral Fluid Using an MRM Method on a GC-Triple Quadrupole MS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Determination of Aminoglycosides in animal tissue by means of LC/MS-MS

Transcription:

Method: 52251 Analysis of Plasticizer Contaminants in Beverages and Milk using an Automated System Based on Turbulent-flow Chromatography Coupled to LC-MS/MS Ebru Ates, Klaus Mittendorf, Thermo Fisher Scientific Food Safety Response Center, Dreieich, Germany Key Words Transcend TurboFlow (TLX) 1. Schematic of Method Sample: Filtration/Centrifugation TSQ Adipate B everages and Milk Phthalates Plasticizer 250 µl Sample + 100 µl IS (make-up to final volume 1 ml MeOH) Vortex 2. Introduction Phthalates are endocrine active chemicals used in a variety of consumer products. In some markets, restricted levels of certain phthalates are permitted for use in food contact materials, but they are not permitted as direct food additives. Phthalates have been used to deliberately adulterate beverages and sports drinks in Taiwan, and phthalates and other plasticizers are widely found as ubiquitous contaminants particularly in fatty foodstuffs. Contamination arises from numerous sources such as the environment and food packaging. Cross-contamination with phthalates can easily arise during trace analysis in the laboratory and there are significant advantages in minimizing sample handling through online automated analysis. A method using online Thermo Scientific TurboFlow chromatography is presented. 3. Scope Centrifuge Milk Sample TLX-MS/MS This method can be applied to the determination of 10 phthalates and one adipate plasticizer at concentrations ranging from 0.05 to 100 mg/l (DMP, DEP, DPP, BBzP, DiBP, DcHP, DHP, DEHP, DEHA, DiNP, DiDP). The method has been validated for 11 plasticizers in beverages and milk. 4. Principle This method employs an automated sample preparation technique involving sample concentration, cleanup and analytical separation in a single run using online sample prep with a Thermo Scientific Transcend TLX system powered by TurboFlow technology. TurboFlow technology serves as a novel sample preparation technique due to its special flow profile and both size exclusion and reversed phase column chemistry. TurboFlow technology enables very effective separation of matrix and target compounds resulting in relatively clean sample extracts. Identification of plasticizers is based on ion-ratios using selected reaction monitoring (SRM) of characteristic transition ions, and quantification of one of the selected SRM ions using labeled internal standards and external calibration. 5. Reagent List Part Number 5.1 Acetone, HPLC grade A9494 5.2 Acetonitrile Optima, for LC-MS A9554 5.3 Water Optima, for LC-MS W64 5.4 Methanol Optima, for LC-MS A4564 5.5 Formic acid A11750 5.6 Isopropanol, HPLC grade A4514

6. Calibration Standards 6.1 Standards 6.1.1 Dimethyl phthalate (DMP) Sigma Aldrich 6.1.2 Diethyl phthalate (DEP) Sigma Aldrich 6.1.3 Diisobutyl phthalate (DIBP) Sigma Aldrich 6.1.4 Dioctyl phthalate (DOP) Sigma Aldrich 6.1.5 Butyl benzyl phthalate (BBzP) Sigma Aldrich 6.1.6 Dihexyl phthalate (DHP) Dr. Ehrenstorfer 6.1.7 Di-2-ethylhexyl adipate (DEHA) Sigma Aldrich 6.1.8 Di(2-ethylhexyl)phthalate (DEHP) Sigma Aldrich 6.1.9 Dicyclohexyl phthalate (DCHP) Sigma Aldrich 6.1.10 Diisononyl phthalate (DiNP) Sigma Aldrich 6.1.11 Diisodecylphthalate (DiDP) Sigma Aldrich 6.2 Internal Standards 6.2.1 Bis(2-ethylhexyl) Dr. Ehrenstorfer phthalate-3,4,5,6- ( -DEHP) 6.2.2 Diisobutyl phthalate-3,4,5,6- Dr. Ehrenstorfer ( -DIBP) 6.2.3 Dihexyl phthalate 3,4,5,6- Sigma Aldrich ( -DHP) 7. Standards Preparation Rinse all glassware with methanol before pipetting plasticizer standards. Prepare fresh working standard mixtures weekly. 7.1 Stock Solution Prepare individual standard stock solution of plasticizer standards in methanol at a concentration of 1 mg/ml in amber flasks. Store the standard stock solutions at 4 C. 7.2 Working Mixture Prepare two working mixtures. Prepare plasticizer mixture 1 (including DMP, DEP, DPP, BBzP, DiBP, DcHP and DHP) at 40 µg/ml in methanol. Prepare plasticizer mixture 2 (including DEHP, DEHA, DiNP, DiDP) at 200 µg/ml. Store the standard mixtures at 4 C. 7.3 Stock Standard Solution of Internal Standard Prepare individual internal standard stock solutions in methanol at a concentration of 1 mg/ml. Store the standard stock solutions at 4 C. 8. Apparatus Part Number 8.1 Transcend TLX-1 system 8.2 Thermo Scientific TSQ Quantum Access Max triple stage quadrupole mass spectrometer 8.3 Precision balance 02225102 8.4 Sartorius analytical balance 14557812 8.5 Thermo Scientific Barnstead 0905043 EASYpure II water 8.6 Ultrasonic bath Elmasonic S40H 15335101 8.7 Vortex shaker 14505141 8.8 Vortex standard cap 3205026 8.9 Centrifuge, Thermo Scientific Hereaus, 503260260 Thermo Scientific Multifuge X3 9. Consumables Part Number 9.1 Thermo Scientific Hypersil GOLD, 25003152130 150 2.1 mm 3 µm 9.2 C18 XL 0.5 50 mm CH953280 9.3 LC vials 3205111 9.4 LC vial caps 3151266 9.5 Pipette Finnpipette 10 100 µl 14386318 9.6 Pipette Finnpipette 100 1000 µl 14386320 9.7 Pipette Finnpipette 500 5000 µl 14386321 9.8 Pipette holder 14245160 9.9 Pipette Pasteur soda lime glass 136786A 150 mm 9.10 Pipette suction device 3120891 9.11 Pipette tips 0.5 250 µl, 500/box 21377144 9.12 Pipette tips 1 5 ml, 75/box 2137750 9.13 Pipette tips 100 1000 µl, 200/box 2137746 9.14 Glass tube 14957E 10. Glassware Part Number 10.1 Fisherbrand, Beaker, 25 ml FB100250 10.2 Fisherbrand, Pasteur pipette 1367830 10.3 Fisherbrand, Volumetric flask, 10 ml FB40010 10.4 Fisherbrand, Volumetric flask, 100 ml 10205C 10.5 Fisherbrand, Volumetric flask, 10205F 1000 ml 7.4 Working Standard Solution of Internal Standard Prepare a standard working mixture of internal standards in methanol at a final concentration of 5 µg/ml. Store the standard stock solutions at 4 C. Page 2 of 6

11. Procedure 11.1 Sample Preparation and Spiking Samples of orange juice, bitter lemon and milk were spiked as described below. Orange Juice 11.1.1 Squeeze one orange into a beaker (rinsed with methanol). Centrifuge (5 min at 5000 rpm) the juice by using 15 ml glass centrifuge tubes (rinsed with methanol). Spike in an LC vial, 250 µl of juice with 100 µl of IS working mixture and the appropriate amount of plasticizer standard working mixture. Fill up to a final volume of 1 ml with methanol and vortex for 10 sec. Milk, (1.5% Fat) Pasteurized, Homogenized 11.1.2 Pipette 250 µl of milk directly into an LC vial. Add 100 µl of IS working mixture and the appropriate amount of plasticizer standard mixture. Fill up to final volume of 1 ml with methanol, vortex for 10 sec. Put the vial into a 15 ml glass centrifuge tube and centrifuge (5 min at 5000 rpm) to remove protein. Transfer the supernatant into an LC vial by the help of a glass pasteur pipette. Bitter Lemon 11.1.3 Pipette 250 µl of bitter lemon (market sample) directly into an LC vial and spike with 100 µl of IS working mixture and the appropriate amount of plasticizer standard working mixture. Fill up to a final volume of 1 ml with methanol and vortex for 10 sec. 12. LC Operating Conditions LC analysis is performed on a Transcend TLX System. The LC conditions are as follows: TurboFlow Column: C18 XL, 0.5 50 mm Analytical Column: Hypersil GOLD C18, 150 2.1 mm, 3 µm Total Run Time: 22 min Mobile Phase: A: acetonitrile (0.1% formic acid) B: methanol (0.1% formic acid) C: water (0.1% formic acid) 12.1 Injector Settings Injector: Thermo Scientific Pal injector with 100 μl injection syringe volume Wash solvents for the Autosampler Solvent 1: acetonitrile/isopropanol/acetone (40/40/20) Solvent 2: methanol Pre clean with solvent 1 [steps]: 3 Pre clean with solvent 2 [steps]: 3 Pre clean with sample [steps]: 0 Filling speed [μl/s]: 50 Filling strokes [steps]: 1 Injection port: LC Vlv1 (TX channel) Pre inject delay [ms]: 500 Post inject delay [ms]: 500 Post clean with solvent 1[steps]: 5 Post clean with solvent 2 [steps]: 5 Valve clean with solvent 1[steps]: 5 Valve clean with solvent 2 [steps]: 5 Injection Volume: 10 µl Tray Temperature: 10 C 13. Mass Spectrometric Conditions MS analysis is carried out using a TSQ Access MAX triple quadrupole mass spectrometer controlled by Thermo Scientific Aria software. Data acquisition and processing is performed using Thermo Scientific Xcalibur 2.1 software. 13.1 Mass Spectrometer Conditions Ionization: Electrospray (ESI) Polarity: Positive ion mode Spray Voltage [V]: 3500 Ion Sweep Gas Pressure [arb]: 0 Vaporizer Temperature [ C]: 350 Sheath Gas Pressure [arb]: 50 Aux Gas Pressure [arb]: 15 Capillary Temperature [ C]: 270 Collision Gas Pressure [mtorr]: 0 Cycle Time [s]: 0.8 Scan Mode: timed selected reaction monitoring (tsrm) The mass spectrometer is programmed with 28 timed segments which is set up for the 11 target plasticizers and 3 labeled internal standards. For each compound one quantifier and one qualifier ion is monitored, including the respective labeled internal standard. The program of segments for tsrm events is shown in Table 2. Loading Pump Eluting Pump Step Flow Flow Step [min] sec [ml/min] Grad A B C Tee Loop [ml/min] Grad A B C 1 0 30 2.0 Step 100 Out 0.7 Step 40 30 30 2 0.5 60 0.4 Step 40 30 30 T In 0.3 Step 40 30 30 3 1.5 330 1.0 Step 100 In 0.7 Ramp 1 98 1 4 7.0 480 0.7 Step 75 25 In 0.7 Step 1 98 1 5 15.0 240 0.5 Step 100 Out 0.7 Ramp 40 30 30 6 19.0 180 0.5 Step 100 Out 0.7 Step 40 30 30 Table 1: TLX-LC gradient program Page 3 of 6

Production 1 Production 2 Start Time Stop Time Tube Ion Retention Analyte Parent (CE) (CE) [min] [min] Lens Ratio Time [min] DMP 194.84 163.09 (11) 77.26 (33) 0.5 2.0 49 0.23 1.40 DEP 223.08 149.08 (18) 121.13 (28) 0.0 2.0 52 0.11 1.56 DPP 251.10 149.07 (16) 121.13 (32) 0.5 2.5 57 0.10 2.37 DiBP 279.13 149.08 (19) 121.10 (31) 1.0 4.0 57 0.07 3.33 -DiBP 283.13 153.09 (20) 69.30 (46) 1.0 4.0 56 0.07 3.30 BBzP 313.09 91.20 (28) 149.05 (12) 1.0 4.0 60 0.72 3.23 DcHP 331.17 149.08 (25) 167.07 (12) 2.5 4.5 59 0.46 4.70 DHP 335.17 149.05 (16) 121.11 (38) 3.0 6.0 60 0.08 5.75 -DHP 339.19 153.05 (17) 125.10 (39) 3.0 6.0 68 0.08 5.73 DEHA 371.25 129.11 (14) 111.13 (22) 4.0 8.0 72 0.35 7.08 DEHP 391.18 149.06 (25) 121.05 (45) 4.5 7.5 72 0.09 7.03 -DEHP 395.26 153.07 (24) 171.07 (13) 4.5 8.0 68 0.32 7.02 DiNP 419.29 149.03 (26) 85.28 (14) 4.5 7.5 76 0.67 7.48 DiDP 447.31 149.01 (30) 85.23 (17) 5.0 8.5 78 0.77 7.90 Table 2: Parameters for tsrm analysis, ion ratios and retention times of plasticizers in methanol (CE = collision energy) 14. Calculation of Results 14.1 Identification Identification of plasticizers is indicated by the presence of ions measured in selected reaction ion monitoring mode (SRM) corresponding to the retention times of appropriate standards. For peak identification the ion ratios are checked. The ion ratios for sample extracts should fall within the tolerance of the corresponding standard (657/2002 EC 1 ). 15. Interpretation of Results 15.1 Quantification By comparing the peak areas of the samples with those of external calibration the quantification of the standards in the spiked samples is carried out. It employs internal standardization using peak area ratios for standards in methanol. D 4 -DiBP is used as the internal standard for DMP, DEP, DPP, DiBP and BBzP; -DHP is used as the internal standard for DHP; and -DEHP is used as the internal standard for DEHP, DEHA, DiNP and DiDP. Plot the calibration curves as the relative peak areas (analyte versus the corresponding internal standard) as a function of concentrations. The plasticizer concentration (c P ) in the samples is determined from the equation: C p = ( A p A IS ) b/a 16. Method Performance Single laboratory method performance characteristics were established by spiking experiments with three samples (homemade orange juice, bitter lemon and milk, see 10.1) with a mixture of plasticizer standards. Method accuracy was assessed at three different spiking levels of plasticizers (low, mid and high level). Other validation parameters included specificity, linearity range and robustness. 16.1 Specificity Using tsrm the specificity was confirmed based on the presence of transition ions at the correct retention time corresponding in timed segments to the plasticizer standards in methanol (Table 2). Specificity determination was based on ion ratio confirmation according to allowed variations in 657/2002 EC (Table 2). The deviation for retention time was in the range of ±2.5%. 16.2 Linearity and Calibration Curve The linearity of calibration curves is assessed over the range from 0.05 to 5 mg/kg (DMP, DEP, DPP, BBzP, DiBP, DcHP and DHP) and 2 100 mg/l (DEHP, DEHA, DiNP, DiDP). In all cases, the correlation coefficients of linear functions are >0.985. The calibration curves are created from eight calibration standards which are injected in each batch in duplicate starting from zero value up to the highest calibration concentration. Between each calibration level methanol is injected as blank. C P plasticizer concentration in mg/l A P peak area of the plasticizer A IS peak area of internal standard b the y-intercept a the slope of calibration curve Page 4 of 6

Figure 1: Calibration curve of DEHP and DiNP with -DEHP as internal standard 16.3 Accuracy Method Accuracy and Precision (Table 3) is evaluated by recovery studies spiking bitter lemon, orange juice and milk at three concentration levels (at low, mid and high levels) of plasticizers. Six replicates are prepared for each experiment, in accordance with EU guidelines. The samples are spiked at 0.2, 2 an mg/l (DMP, DEP, DPP, BBzP, DiBP, DcHP and DHP) and 8, 40 and 80 mg/l (DEHP, DEHA, DiNP, DiDP) levels. Found concentrations (mg/l), recovery, standard deviation (STDV) and relative standard deviation (%RSD) are calculated. Orange Juice Bitter Lemon Milk Analyte Rec % (%RSD) Rec % (%RSD) Rec % (%RSD) DMP 94.5 (5) 102.4 (6) 111.0 (4) DEP 97.6 (4) 111.0 (5) 108.7 (3) DPP 106.7 (4) 112.4 (4) 118.0 (3) BBzP 103.3 (3) 90.0 (4) 98.9 (2) DiBP 115.8 (4) 90.0 (8) 92.2 (3) DcHP 77.8 (4) 81.0 (5) 69.0 (3) DHP 96.3 (4) 96.1 (5) 93.8 (3) DEHP 97.2 (15) 85.7 (8) 78.2 (9) DEHA 64.8 (14) 70.4 (7) 76.1 (7) DiNP 84.5 (12) 75.9 (8) 71.9 (3) DiDP 72.6 (10) 71.2 (1) * Table 3: Average recovery and RSD of plasticizer standards in orange juice, bitter lemon and milk 17. Conclusion A method for the determination of plasticizers in beverages and milk has been developed to enable fast and cost-effective automated determination of selected plasticizers. Online TurboFlow sample preparation coupled to the analytical HPLC separation equipped with a triple quadrupole detector enables very selective and effective determination of plasticizers. Elimination of time-consuming steps like liquid liquid extraction (LLE) or solid phase (SPE), followed by evaporation and reconstitution enables high sample throughput. Reducing sample treatment steps reduces the probability of cross contamination as well. 18. Reference 1. Commission Decision 657/2002 of August 2002 on implementing Council Directive 96/23/EC concerning performance of analytical methods and the interpretation of results. Official journal of the European communities, L221, 8-36, 2002. * DiDP is not applicable for milk matrix Page 5 of 6

19. Annex In addition to these offices, Thermo Fisher Scientific maintains a network of representative organizations throughout the world. Figure 2: Chromatogram: Separation of plasticizer standards in methanol (c = 1.5 mg/l) at TLX-LC gradient program (Table 1) Africa-Other +27 11 570 1840 Australia +61 3 9757 4300 Austria Belgium +32 53 73 42 41 Canada +1 800 530 8447 China +86 10 8419 3588 Denmark +45 70 23 62 60 Europe-Other Finland/Norway / Sweden +46 8 556 468 00 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9434 Italy +39 02 950 591 Japan +81 45 453 9100 Latin America +1 561 688 8700 Middle East Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Russia/CIS South Africa +27 11 570 1840 Spain +34 914 845 965 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752 www.thermoscientific.com Legal Notices: 2011 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. TG52251_E 12/11M Part of Thermo Fisher Scientific