Bent crystals as a tool for manipulation of ultra-relativistic electron beams. Institut fur Kernphysik, Johannes Gutenberg Universitat Mainz, Germany

Similar documents
Single and Multiple Volume Reflections of Ultra-Relativistic Electrons in a Bent Crystal as Tools for Intense Production of Electromagnetic Radiation

arxiv: v1 [physics.acc-ph] 10 Nov 2015

INTRODUCING CHANNELING EFFECT

The limits of volume reflection in bent crystals

CRYM: a channeling emulation program based on the latest experimental data

Preparing for a Crystal Experiment Proposal

High Energy High Intensity Hadron Beams

1,0 0,8. Coefficient 0,6 0,4 0,2

JLab Nov. 1. R. Avakian

Studies of Nanotube Channeling for. Efficient Beam Scraping at Accelerators

Status and Results of the UA9 Crystal Collimation Experiment at the CERN-SPS

NEGATIVE PARTICLE PLANAR AND AXIAL CHANNELING AND CHANNELING COLLIMATION

Channeling Experiments with Electrons at the Mainz Microtron MAMI

Experiments on deflection of charged particles using silicon crystals at. Proton Synchrotron (KEK(

A Crystal Routine for Collimation Studies in Circular Proton Accelerators

GECO - GEANT4 CRYSTAL OBJECTS ENRICO BAGLI TITLE OF THE PROJECT NAME OF THE PRINCIPAL INVESTIGATOR ABSTRACT

Crystal Channeling Radiation and Volume Reflection Experiments at SLAC

V.G. Baryshevsky. Institute for Nuclear Problems, Belarusian State University, Minsk, Belarus

ADVANCED PHOTON SOURCES AND THEIR APPLICATIONS

arxiv: v1 [nucl-ex] 23 Mar 2015

arxiv: v1 [physics.acc-ph] 29 Nov 2014

48 K. B. Korotchenko, Yu. L. Pivovarov, Y. Takabayashi where n is the number of quantum states, L is the normalization length (N = 1 for axial channel

Cross section measurements of the elastic electron - deuteron scattering

A Study of RHIC Crystal Collimation

JLEIC forward detector design and performance

The Detector Design of the Jefferson Lab EIC

Feasibility of measuring the magnetic dipole moments of the charm baryons at the LHC using bent crystals

DEFLECTION OF PROTON BEAMS BY CRYSTAL MISCUT SURFACE

3. Synchrotrons. Synchrotron Basics

Channeling of high-energy particles in a multi-wall nanotube

Check the LCLS Project website to verify 2 of 6 that this is the correct version prior to use.

A method to polarise antiprotons in storage rings and create polarised antineutrons

The heavy-ion magnetic spectrometer PRISMA

SHiP: a new facility with a dedicated detector for neutrino physics

Search for an electric dipole moment with polarized beams in storage rings

PoS(EPS-HEP2017)533. First Physics Results of AWAKE, a Plasma Wakefield Acceleration Experiment at CERN. Patric Muggli, Allen Caldwell

XVII International Conference on Hadron Spectroscopy and Structure - Hadron September, 2017 University of Salamanca, Salamanca, Spain

BREMSSTRAHLUNG IN A THIN LAYER OF MATTER AT HIGH ENERGY

EXPERIMENTAL INVESTIGATIONS OF SYNCHROTRON RADIATION AT THE ONSET OF THE QUANTUM REGIME

Determination of parameters of cascade showers in the water calorimeter using 3D-distribution of Cherenkov light

Characterizations and Diagnostics of Compton Light Source

RADIATION SOURCES AT SIBERIA-2 STORAGE RING

Project P2 - The weak charge of the proton

Crystal Channelling Simulation CATCH 1.4 User s Guide

Advantages of axially aligned crystals used in positron production at future linear colliders

arxiv: v1 [physics.acc-ph] 1 Sep 2015

The Mainz Microtron MAMI

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH

Examples for experiments that can be done at the T9 beam line

arxiv: v1 [hep-th] 29 Sep 2017

Design of the Mainz Active Polarized Proton Target

Beam Asymmetry measurement in Pion Photoproduction on the neutron using CLAS

arxiv: v3 [hep-ex] 10 Feb 2018

Electron Transport Line for Mu2e Calibration System. August 7, Abstract

CERN EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH THE CLIC POSITRON CAPTURE AND ACCELERATION IN THE INJECTOR LINAC

Experimental Tests of Charge Symmetry Breaking in Hypernuclei

Light Source I. Takashi TANAKA (RIKEN SPring-8 Center) Cheiron 2012: Light Source I

PoS(Baldin ISHEPP XXII)042

Response function of the magnetic spectrometer PRISMA

ON THE DISCOVERY OF COHERENT BREMSSTRAHLUNG IN A SINGLE CRYSTAL AT THE FRASCATI NATIONAL LABORATORIES

Research with Synchrotron Radiation. Part I

Strange Hadron Production from STAR Fixed-Target Program

Zero degree neutron energy spectra measured by LHCf at s = 13 TeV proton-proton collision

Measurement of secondary particle production induced by particle therapy ion beams impinging on a PMMA target

A Meter-Scale Plasma Wakefield Accelerator

Geant4 simulations of the lead fluoride calorimeter

Differential Cross Section Measurements in Ion-molecule Collisions

Proton-Nucleus Scattering Approximations and Implications for LHC Crystal Collimation*

Notes on x-ray scattering - M. Le Tacon, B. Keimer (06/2015)

IPBI-TN June 30, 2004

Doubly-polarised pion photoproduction and the GDH sum rule on the nucleon at MAMI

Muoproduction of exotic charmonia at COMPASS

The LHCf data hadronic interactions and UHECR showers. Paolo Lipari LHCf meeting Catania, 6th july 2011

High Energy Channeling and the Experimental Search for the Internal Clock Predicted by L. de Broglie

The photoneutron yield predictions by PICA and comparison with the measurements

GRAINE Project: a balloon-borne emulsion gamma-ray telescope

Neutrino physics with the SHiP experiment at CERN

Investigation of Pygmy Dipole Resonance in neutron rich exotic nuclei

ABSOLUTE AIR-KERMA MEASUREMENT IN A SYNCHROTRON LIGHT BEAM BY IONIZATION FREE-AIR CHAMBER

First indication of LPM effect in LHCf, an LHC experiment

W, Z and top production measurements at LHCb

arxiv: v2 [hep-ex] 12 Feb 2014

Determination of lifetimes of nuclear excited states using the Recoil Distance Doppler Shift Method in combination with magnetic spectrometers

PoS(NOW2016)003. T2K oscillation results. Lorenzo Magaletti. INFN Sezione di Bari

A proposed very high energy electron proton collider, VHEeP

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Dilepton Forward-Backward Asymmetry and electroweak mixing angle at ATLAS and CMS

Theory English (Official)

Status of the LHCb RICH detector and the HPD

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Hands on LUNA: Detector Simulations with Geant4

GEANT4 Emittance Diagnostics Simulations for the ERL Injector Prototype

The possibility to use energy plus transmutation set-up for neutron production and transport benchmark studies

CONCEPTUAL STUDY OF A SELF-SEEDING SCHEME AT FLASH2

Study of multi-nucleon transfer reactions with light nuclei

2.24 Simulation Study of K L Beam: K L Rates and Background Ilya Larin Department of Physics Old Dominion University Norfolk, VA 23529, U.S.A.

Measuring very forward (backward) at the LHeC

Focusing of Parametric X-ray Radiation from a Bent Crystal

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Search for Gluonic Excitations with GlueX at Jefferson Lab

Transcription:

Bent crystals as a tool for manipulation of ultra-relativistic electron beams 1 INFN Sezione di Ferrara via Saragat 1 44122 Ferrara, Italy E-mail: laura.bandiera@cern.ch E. Bagli, G. Germogli, V. Guidi, A. Mazzolari INFN Sezione di Ferrara & Università degli Studi di Ferrara, Italy H. Backe, W. Lauth Institut fur Kernphysik, Johannes Gutenberg Universitat Mainz, Germany A. Berra, D. Lietti, M. Prest INFN Sezione di Milano Bicocca & Università degli Studi dell Insubria, Italy D. De Salvador INFN Sezione di Legnaro & Università degli Studi di Padova, Italy E. Vallazza INFN Sezione di Trieste, Italy V. Tikhomirov Institute for Nuclear Problem of Belarusian State University, Minsk, Belarus Channeling and coherent interactions of charged particles in crystals are known since the 60s and used as a tool for material analysis by low-energy ion channeling and for the generation of linearly polarized γ-beams through coherent bremsstrahlung at electron accelerators. We report on an experiment carried out at the MAinzer MIkrotron with the aim of investigating the electromagnetic radiation generated by 855 MeV electrons in a bent crystal. Such study allows one to investigate the influence of the crystalline curvature on the radiation emitted by sub-gev electrons in a bent crystal and the possible application of this kind of radiation. 38th International Conference on High Energy Physics 3-10 August 2016 Chicago, USA 1 speaker Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0). http://pos.sissa.it/

1.Introduction Channeling and coherent interaction of charged particles in crystals are known since the 60s and used as a tool for material analysis by low-energy ion channeling and for the generation of linearly polarized γ-beams through coherent bremsstrahlung at electron accelerators [1,2], such as the MAinzer MIcrotron (MAMI) in Germany and the Jefferson Lab in USA. Channeling consists in the trapping of charged particles with energy E and with an angle of incidence with the crystal planes (axes) smaller than ϑ critical = 2U 0 / E inside the planar (axial) potential well depth U 0 [3]. If the crystal is bent, channeled particles follow the crystal bending and are steered from their initial direction. The usage of bent crystals has been deeply investigated for beam manipulation in hadron-accelerator, e.g., CERN SPS and LHC, where bent crystals can be exploited for beam steering in crystal-assisted collimation or extraction [4-7]. Bent crystals may found relevant application also for the manipulation of high-energy e± beams. In this case, beam deflection is accompanied by the generation of electromagnetic radiation. Here, we present results on beam steering and, in particular, on intense e.m. radiation generation through interaction of high-energy electrons with bent crystals. In case of bent crystals, also un-channeled particles can be deflected through the mechanism of Volume Reflection (VR), which consists in the steering of over-barrier particle trajectories and occurs in a wide angular acceptance, which is equal to the bending angle of the crystal [ 8]. VR consists in the reversal of transverse momentum of over-barrier particles by the interaction with the planar potential barrier at the tangency point of the trajectory with curved crystalline planes. The experiment was carried out at MAMI with a sub-gev electron beam. A particular attention is given to the possible applications, such as an intense crystal-based x- or γ-ray source. 2.Experiment at MAMI A 855 MeV electron beam, available at the MAMI B facility, was set at a beam size of 200 70 μm 2 and a divergence of 70 30 μrad 2 along the horizontal and vertical directions, respectively. In this way, the beam divergence resulted to be much less than the planar critical angle, being about 220 μrad at this energy for the Si (111) planes. The setup was based on the one of Ref. [9] with the adding of a single-sided microstrip Si detector developed at the INSULAB of the University of Insubria of Como and the INFN of Trieste (Italy). A bending magnet separates the photons emitted by the 855 MeV electrons inside the crystal from the charged beam. The Si detector was placed 5.973 m downstream of the crystal along the electron beamline, with an angular resolution better than 10 μrad. At a distance of 8.627 m from the crystal along the photon beamline a 10 x 10 NaI scintillator detector. An aperture of 4 mm diameter in the lead shield surrounding the detector allows the collection of the forward portion of the emitted photons, resulting in a collimator aperture of 0.46 mrad, i.e., equal to 0.8 times the typical radiation angle, 1/γ 600 μrad. More details on the experimental setup can be found in Ref. [10]. Finally, a (30.5±0.5) μm bent Si crystal fabricated at the Sensors and Semiconductor Laboratatory of Ferrara University, was used to steer the 855 electron beam. With the usage of a mechanical holder, a secondary bending radius of 33.5 mm 2

of the (111) planes was obtained due to the quasi-mosaic effect [11]. The crystal holder was mounted on a high-precision goniometric system equipped with 5 degrees of freedom: two translational movements allow aligning the crystal on the horizontal and vertical directions with an accuracy of 1 μm; three rotational stages were used to rotate the sample around the x, y and z axes with an accuracy of 50, 9 and 175 μrad, respectively. The crystal was positioned to deflect particles in vertical direction, i.e., normal to that of the bending magnet. Figure 1. Experimental deflected beam distribution vs. the incoming angle with respect to the bent (111) planes. We report here a brief summary of the deflecting proprieties of the crystal presented in Ref. [12]. The deflection angle and efficiency of the electrons vs. the angle between crystal planes with the beam were recorded. Fig. 1 represents the distribution of the beam particles after interaction with the crystal vs. the crystal-to-beam orientation. For incidence angle θ in < - θ critical = -220 μrad, the crystal planes are misaligned with respect to the beam direction and the crystals seems to scatter particles as an amorphous medium. For angle within two times the critical angle, particles are channeled and deflected at the crystal bending angle of about 910 μrad. For incidence angle larger than the critical one but smaller than the bending angle, 220 μrad < θ in < 910 μrad, particles are volume-reflected by an angle of about -190 μrad in a direction opposite to that of crystal channeling. One should notice that at zero position not all the particles are deflected at the full bending angle, but there is a strong contribution of nearly undeflected particles or deflected at a smaller bending angle. Indeed, thus particles were dechanneled. Dechanneling is the kick out of particles from a channel as the transverse energy of channeled electrons becomes higher than the planar potential barrier due to the incoherent scattering of the particles by crystal electrons and nuclei. On the other hand, for the same reason, overbarrier particles may be captured by crystal planes; that occurs in the VR region, where some particles may be volume-captured in the planar potential well due to the contribution of incoherent scattering. Volume Capture (VC) consists in the entry of above-barrier particles into the channeling regime when particle trajectories are at the tangency point with the bent planes. 3

Summarizing, it is evident from Fig. 1 that, even channeling of particle may give rise to a larger deflection angle, VR is much more efficient to steer a sub-gev electron beam, since occur for overbarrier particles thus avoiding the spoiling effect of dechanneling. Figure 2. Experimental radiation spectrum vs. the incoming angle with respect to the bent (111) planes. The collimator aperture was 4 mm, differently from Ref. [13] in which a larger aperture of 40 mm did not permitted to highlight the CB V-tail structure caused by the forward photons. Here, we report an investigation on the radiation emitted by 855 MeV electrons in the bent crystal in case of alignment and misalignment between the beam direction and the bent (111) Si planes[13]. Fig. 2 displays the recorded experimental radiation spectrum after interaction with the crystal vs. the crystal-to-beam orientation: the angular range selected lies within -3 and 3 mrad. One may notice the low energy peak, which are associated with planar channeling at zero incidence, splits at increasing photon energy into two well distinguishable branches with enhanced photon intensity (see the V pattern in the picture). This phenomenon is observed just in the transition region between channeling radiation (CR) and coherent bremsstrahlung (CB) emission. We remind here that CR is generated by the nearly oscillatory motion of electrons in the planar channels, while CB peaks are generated by overbarrier electrons/positrons crossing the periodical structure of a crystal lattice, i.e., crossing crystal planes with a small incidence angle but still larger than θ critical. CB radiation is expected to be harder due to the smaller oscillatory period, which increases with θ in, but less intense tha CR. The V-shape feature has already been reported in the literature for straight crystals (see for instance Fig. 12 in [9]), while is a novelty for the case of bent crystals, since the collimator apeture used for the goniometer scan presented in Ref. [13] was too large, 40 mm, to highlight the CB V-tail structure, caused by the forward photons. The usage of a smaller aperture permitted also to visualize better the loss of intensity for hard photon emission under CB. In Fig. 2, one may also notice the extension of the intense and soft CR zone to the VR region on the right side of zero incidence angle. Indeed, for straight crystals, the radiation 4

intensity falls off very rapidly out of the channeling region, which is as large as 2θ critical = 440 μrad. The strongest intensity for VR as compared to CB, that makes this kind of radiation more similar to CR, has been explained in Ref. [13] by the contribution of volume-captured particles, which have a similar dynamics to channeled ones. Figure 3. Experimental spectra for channeling (blue), VR at θ in = 420 μrad (red) and at θ in = 800 μrad (pink) from perfect alignment with the bent (111) Si planes. For comparison also the over-barrier (OB) spectra at at θ in = -420 μrad (black) and at θ in = -800 μrad (green) are shown. For a more detailed investigation of the features of the radiation accompanying VR, Fig. 3 shows the single spectra collected at different crystal-to-beam orientations: blue line for zero incidence angle (CR), at θ in =+ 420 μrad (red line) in the middle of VR region and at θ in = 800 μrad (pink line) at the end of VR region. In the latter case the contribution of VC is weaker, because electrons can be captured only at the crystal end, and thereby the radiation peak is less pronounced. In all these three cases, the radiation is peaked around 1.8 MeV, being the peak more pronunced for CR and for VR at θ in =+ 420 μrad. In order to compare VR with the misalignment case, Fig. 3 also shows the spectra at θ in =- 420 μrad (black line) on the opposite side to VR region and at θ in = - 800 μrad (green line). One may notice that the radiation accompanying VR remains more intense than for the over-barrier case with opposite incidence angle to crystal planes. 3. Conclusions The radiation emitted by 855 MeV electrons via planar channeling and volume reflection in a tens-micrometer long bent Si crystal was recorded. In both cases, the radiation spectra were much more intense than for the case of misalignment between crystal planes and beam direction, i.e. than for an equivalent amorphous material. Furthermore, the radiation spectra were peaked in the MeV energy range. As already seen in the 100 GeV energy range [14,15], the deflection efficiency is larger for VR than for channeling and the angular acceptance for both radiation and beam deflection is wider. Indeed, here we showed that the radiation accompanying VR is comparable in intensity to the radiation in straight crystals, i.e., it is a sort of intermediate case between CR and CB. Indeed, the intensity of radiation accompanying volume reflection is maintained high in the whole 5

angular acceptance, thus making this effect a good candidate for the realization of a gamma-ray source with poor-emittance electron beams in the Sub-GeV/GeV energy range accessible by many electron accelerators worldwide, e.g. SLAC, MAMI and JLab. References [1] M. L. Ter-Mikaelian, High-Energy Electromagnetic Processes in Condensed Media (Wiley, New York, 1972). [2] V. Baier, V. Katkov, and V. Strakhovenko, Electromagnetic Processes at High Energies in Oriented Single Crystals (World Scientific, Singapore, 1998). [3] J. Lindhard, Danske Vid. Selsk. Mat. Fys. Medd. 34, 14 361 (1965). [4] E. Tsyganov, Tech. Rep. (Fermilab, 1976) preprint TM-682. [5] V. M. Biryukov et al., Nucl. Instrum. Methods Phys. Res. Sect. B 234, 23 (2005). [6] E. Uggerhoj and U. Uggerhoj, Nucl. Instrum. Methods Phys. Res. Sect. B 234, 31 (2005). [7] W. Scandale et al., Phys. Lett. B 692, 78 (2010). [8] A. Taratin and S. Vorobiev, Phys. Lett. A 119, 425 (1987). [9] H. Backe, P. Kunz, W. Lauth, and A. Rueda, Nucl. Instrum. Methods Phys. Res., Sect. B 266, 3835 (2008). [10] D. Lietti et al., Rev. Sci. Instrum. 86, 045102 (2015). [11] G. Germogli, A. Mazzolari,, E. Bagli, and V. Guidi, Nucl. Instrum. Methods Phys. Res., Sect. B 355, 81 (2015). [12] A. Mazzolari et al., Phys. Rev. Lett. 112, 135503 (2014). [13] et al., Phys. Rev. Lett.115, 025504 (2015). [14] W. Scandale et al., Phys. Rev. A 79, 012903 (2009). [15] et al., Nucl. Instrum. Methods Phys. Res., Sect. B 309, 135 (2013). 6