INFLUENCE OF EXPOSURE GEOMETRY ON THE RESPONSE OF CR39 SSNT RADON DETECTORS *

Similar documents
Uncertainty in radon measurements with CR39 detector due to unknown deposition of Po

The optimum time of etching proved the Sensitivity of the CR-39 detector

ABSTRACT. Keywords: CR-39 Detector, chemical etching techniques, new etchant, Methanol. INTRODUCTION

Study of Radium and Radon Exhalation Rate in Some Sand Samples Using Solid State Nuclear Track Detectors

Measurement of indoor radon, thoron and annual effective doses in the some dwellings of Jaipur city, Rajasthan, India

Measurement of Radon and Uranium Concentrations and Background Gamma Rays at the University of Baghdad -Jadiriyah Site

RADON EQUILIBRIUM MEASUREMENT IN THE AIR *

Measurement of radon ( 222 Rn) and thoron ( 220 Rn) concentration with a single scintillation cell

Radon Activity And Exhalation Rate In Building Materials From Crushing Zone Of Shivalik Foothills In India

International Journal of PharmTech Research CODEN (USA): IJPRIF, ISSN: , ISSN(Online): Vol.9, No.9, pp , 2016

CALIBRATION OF INSTRUMENTS MEASURING RADON OVER A LARGE ACTIVITY RANGE. N. Michielsen, V. Voisin

Sensitivity of LR 115 detectors in hemispherical chambers for radon measurements

RESPONSE OF A RADON CHARCOAL CANNISTER TO CLIMATIC AND RADON VARIATIONS IN THE INTE RADON CHAMBER. A. Vargas, X. Ortega, I.

Ion Chamber. Radon Measurements. Theremino System Rev.1. Theremino System IonChamber_ENG Page 1

SYSTEM OF MONITORING THE ATMOSPHERICAL RADON WITH AN IONIZATION CHAMBER DETECTOR TYPE IN PULSE MODE

Multilayer Nuclear Track Detectors for Retrospective Radon Dosimetry

Chapter 2 MATERIALS, INSTRUMENTS AND TECHNIQUES

Theoretical basis for long-term measurements of equilibriumfactors using LR 115 detectors

Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD

CARBOXEN 564 A NEW CARBON MOLECULAR SIEVE SORBENT USED FOR RADON AND THORON MONITORING

J. Rad. Nucl. Appl. 2, No. 1, (2017) 11 Journal of Radiation and Nuclear Applications An International Journal

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.8, No.3, pp , 2015

A Simple Measurement Technique of the Equilibrium. Equivalent Thoron Concentration with a CR-39 Detector

LONG-TERM MEASUREMENTS OF RADON PROGENY CONCENTRATIONS WITH SOLID STATE NUCLEAR TRACK DETECTORS

ATOMIC PHYSICS Practical 11 STUDY OF DECOMPOSITION OF RADIOACTIVE RADON 1. INTRODUCTION

COMBINED LSC-BASED METHOD FOR RADON IN AIR MEASUREMENTS

Influence of aerosol concentration and multivariate processing on the indication of radon progeny concentration in air

Radioactivity measurements and risk assessments in soil samples at south and middle of Qatar

Evaluation Model of Atmospheric Natural Radiaoctivity Considering Meteorological Variables

Single-sheet identification method of heavy charged particles using solid state nuclear track detectors

Radiation Safety Training Session 1: Radiation Protection Fundamentals and Biological Effects

Radon Determination by Activated Charcoal Adsorption and Liquid Scintillation Measurement. Canoba, A.C.; López, F.O. and Oliveira, A.A.

Keywords: Cape coast, concentration, E-PERM, exposure, LR-115, radon

LSC-BASED APPROACH FOR RADON IN SOIL GAS MEASUREMENTS. The Marzeev Institute of Hygiene and Medical Ecology 50, Popudrenko str., Kiev 02094, Ukraine.

REPORT RESULTS OF RADON DIFFUSION COEFFICIENT (SAMPLES SYNTHESIA O-14015)

WM2018 Conference, March 18-22, 2018, Phoenix, Arizona, USA. PVT and LaBr3(Ce)-based Radon Express Analyzers 18164

TRACERLAB. Natural Radiation, the Determination of Radon, Thoron and it s Progenies. Quality and Technology - Made in Germany - TRACERLAB GmbH

ALPHA AND GAMMA SPECTROSCOPY METHODS FOR THORON PROGENY IMPLANTED IN GLASSES AND OTHER MATERIALS

SECTION 8 Part I Typical Questions

Research about the quantity of Radon in our everyday places

Chemical etching characteristics for cellulose nitrate

Radon Emanation Testing for DRIFT

P7 Radioactivity. Student Book answers. P7.1 Atoms and radiation. Question Answer Marks Guidance

EXPERIMENTAL TECHNIQUE TO MEASURE THORON GENERATION RATE OF BUILDING MATERIAL SAMPLES USING RAD7 DETECTOR

Optical density for CN-85 and CR-39 Plastic Detectors and α-particle Radiography

WHAT IS IONIZING RADIATION

Results of the 2015 national indoor radon intercomparison measurements in Serbia

ZX or X-A where X is chemical symbol of element. common unit: [unified mass unit = u] also known as [atomic mass unit = amu] or [Dalton = Da]

Performance Characterization of A New Cam System M.J. Koskelo 1, J.C. Rodgers 2, D.C. Nelson 2, A.R. McFarland 3 and C.A. Ortiz 3

AMS MEASUREMENTS OF DEUTERIUM CAPTURED IN TUNGSTEN LAYERS DEPOSITED BY MAGNETRON SPUTTERING

Radiation Protection Fundamentals and Biological Effects: Session 1

Radiation Awareness Training. Stephen Price Office of Research Safety

This document is a preview generated by EVS

Atomic Structure Summary

Variation of Bulk Etch Rate and some other Etching Parameters with Etching Temperature for Cellulose Nitrate LR-115 Detector

Differentiating Chemical Reactions from Nuclear Reactions

Experiment Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

V.Schmidt, P. Hamel. Radon in the Living Environment, April 1999, Athens, Greece

The LSC Approach to Radon Counting in Air and Water

Track Etch Detectors (TED)

Radioactivity is the spontaneous disintegration of nuclei. The first radioactive. elements discovered were the heavy atoms thorium and uranium.

Application Note. The Continuous Air Monitoring (CAM) PIPS Detector Properties and Applications

Particle size distribution of the radon progeny and ambient aerosols in the Underground Tourist Route "Liczyrzepa" Mine in Kowary Adit

Nuclear Radiation. Natural Radioactivity. A person working with radioisotopes wears protective clothing and gloves and stands behind a shield.

Chapter 3 Radioactivity

Determination of Radon Gas Concentrations and Radon Exhalation Rate in Soil Sample in Selected Regions in Anbar Governorate

NORM and TENORM: Occurrence, Characterizing, Handling and Disposal

DYNAMICS OF OUTDOOR RADON AND THORON PROGENY CONCENTRATIONS IN SOME GEOGRAPHICAL AREAS OF ROMANIA *

Assessment of Rn and U Concentrations in the Soil of Qadafery, Kalar and Zarayan Located in Sulaimani Governorate of Kurdistan Region- Iraq

Uranium Concentrations measurement for Ground Water and Soil Samples in Al-Najaf/Iraq

STUDIES ON THE AEROSOL RADIOACTIVITY LEVEL AND AIR QUALITY AROUND NUCLEAR RESEARCH INSTITUTE AREA

Measurements of Thoron Concentration by Passive Cup Method and Its Application to Dose Assessment

Activity 11 Solutions: Ionizing Radiation II

ABSORBED DOSE TO WATER MEASUREMENTS IN HIGH ENERGY ELECTRON BEAMS USING DIFFERENT PLANE PARALLEL CHAMBERS *

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

BULK ETCH RATE MEASUREMENT OF CR-39 DETECTOR AT CONSTANT NORMALITY USING THE DIAMETERS AND THE LENGTHS OF THE TRACKS OF α-particles

RADIOACTIVITY. Nature of Radioactive Emissions

Physics 30: Chapter 8 Exam Nuclear

Level of Radionuclide Contents in Surface Water from Shutt- Al-Arab River in Basrah Governorate, Iraq

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

M. Rogozina, M. Zhukovsky, A. Ekidin, M. Vasyanovich. Institute of Industrial Ecology, Ural Branch Russian Academy of Sciences

SIMULATION OF SPACE RADIATION FOR NANOSATELLITES IN EARTH ORBIT *

European Project Metrology for Radioactive Waste Management

Characterising NORM hazards within subsea oil and gas facilities. Daniel Emes SA Radiation

RADIOECOLOGICAL PROBLEMS IN HOME BUILDING IN THE CITY OF NOVI SAD

A Brief Overview of Radiation and Analytical Water Testing for Radiological Contaminants.

7.1 Atomic Theory and Radioactive Decay

Introduction to Ionizing Radiation

D DAVID PUBLISHING. 1. Introduction. Guillermo Espinosa and José-Ignacio Golzarri

Chapter 29. Nuclear Physics

Radiation Protection & Radiation Therapy

ARMUG New CAM Developments. Arran Morgan MSc Physicist

CR-39 TRACK DETECTORS IN COLD FUSION EXPERIMENTS: REVIEW AND PERSPECTIVES. A. S. Roussetski

Neutron and Gamma Ray Imaging for Nuclear Materials Identification

Image Analysis of Cr-39 and Cn-85 Detector Irradiated by Thermal Neutron

L 36 Modern Physics [3] The atom and the nucleus. Structure of the nucleus. The structure of the nucleus SYMBOL FOR A NUCLEUS FOR A CHEMICAL X

MATHEMATICAL MODEL OF RADON ACTIVITY MEASUREMENTS

Etching Properties of Polyethyleneterephthalate (PET) Melinex-E Nuclear Track Detectors (NTDs)

Gamma Irradiation Effects on Track Properties of PADC-American Acrylics Track Detector

Transcription:

Romanian Reports in Physics, Vol. 63, No. 2, P. 376 382, 11 INFLUENCE OF EXPOSURE GEOMETRY ON THE RESPONSE OF CR39 SSNT RADON DETECTORS * ELENA ROBU 1, FRANZ JOSEF MARINGER 2, MASSIMO GARAVALIA 3, LUCA PICINI 3 1 Physics Department, Bucharest University, PO Box MG-11, Bucharest, Romania 2 Federal Office of Metrology and Surveying, 10 Wien, Faradaygasse 3, Arsenal Objekt 214, Vienna, Austria 3 Radiation Measurements Laboratory, Regional Agency of Environmental Protection, Udine, Via Tavagnacco 91, 33100 Udine, Italy email: elena_robu@hotmail.com Received January, 10 Abstract. A number of about 1 solid state nuclear track detectors (SSNTD) of CR39 type were exposed in controlled conditions in a Radon Exposure Calibration chamber. The purpose of the work was to study the dependence of the response of the detector to the exposure conditions. Identically shaped CR39 detectors were placed in open cylindrical cups of various geometries (height and diameter). For each geometry the side surface of the detector cup was coated with three materials, paper, plastic and aluminum. The effect of the coating of the detector cup on the plate-out of the radon decay products, as well as on the detector response was investigated for each geometry of the detector cup. The dependence of the response on the geometry of the cup was also studied. Key words: CR39, SSNTD, radon detector. 1. INTRODUCTION Approximately half of the human exposure to natural radiation is due to the airborne short-lived progeny of the indoor radon gas ( 222 Rn) [1,2]. The radon gas is originated from the ground and other materials containing its predecessor, 226 Ra. In fact, there are different radioisotopes of radon. The most commonly discussed three radioisotopes are 222 Rn, 2 Rn (thoron) and 219 Rn, which are members of the natural radioactive decay series of 238 U, 232 Th and 2 U, respectively. Among these three radioisotopes, 222 Rn is the most important due to its longest half life of 3.8 d. Therefore, when radon is used without specification of a particular radioisotope, it is usually referring to 222 Rn. Being an inert noble gas, 222 Rn may diffuse from the place of formation and penetrates the boundary surface with the air. Accumulation * Paper presented at the Annual Scientific Session of Faculty of Physics, University of Bucharest, June 5, 09, Bucharest Măgurele, Romania.

2 The response of CR39 SSNT radon detectors 377 of 222 Rn in a closed space, like the indoor environment of a dwelling, can pose a potential health hazard. Many research papers and books have been devoted to the studies of 222 Rn and its short-lived progeny. Various problems related to radon have been investigated such as the measuring techniques, radon penetration properties into houses, dose determination, health risk estimation, etc. On the other hand, radon map on some terrains may help discover underground uranium/thorium ores. It can also serve as a pre-signal for earthquakes or volcano eruptions etc. Many different methods have been developed for radon measurement. They can be classified according to the duration as grab sampling and long-term measurements. Grab sampling methods, among which the best known is the use of scintillation cells, give information on the 222 Rn concentration in a relatively short period of time. However, the airborne 222 Rn concentration is subjected to variations so the knowledge in a relatively short period of time might not be representative of the average concentration. In contrast to grab sampling, long-term measurements take much longer time and the average 222 Rn concentration during the exposure period can be acquired. The most often used long-term methods are based on Solid State Nuclear Track Detectors (SSNTDs) and activated charcoal canisters. These two methods do not require any power supply during the operation so that they belong to the group of passive methods. To determine the radon concentration from SSNTD readings (which is the track density, or the number of tracks per unit area), one needs to know the detector sensitivity that relates the track density to the total exposure of the detector to radon and its progeny. Experimental determination of this sensitivity, i.e., calibration of these detectors for radon and progeny measurements is carried out by exposing them to known concentrations of radon and/or its progeny in a radon exposure chamber. Calibration should be carried out with the same procedures as those followed in the real life measurements (including procedures for detector processing and readout). 2. THE PRINCIPLE OF SSNTDs Heavy charged particles, such as alpha particles, light and heavy ions or fission products, cause extensive ionization when they pass through a medium [3,4]. This primary ionization triggers a series of new chemical processes that result in the creation of free chemical radicals and other chemical species. Along the path of the alpha particle, a zone enriched with free chemical radicals and other chemical species is then created. This damaged zone is called a latent track and can remain stable for many years in some dielectric materials.

378 Elena Robu et al. 3 If a piece of material containing latent tracks is exposed to some chemically aggressive solution such as NaOH or KOH, chemical reactions would be more intensive along the latent tracks. The overall effect is that the chemical solution etches the surface of the detector material, but with a faster rate in the damaged region. In this way, a track (or sometimes called pit) of the particle is formed, which may be seen under an optical microscope. One of the most commonly used SSNTDs is the CR-39 detector, which was based on polyallyldiglycol carbonate and was discovered by Cartwright et al. [5]. 3. EXPERIMENTAL SETUP In our work 136 SSNTD of CR39 type were exposed in the calibrated Radon Chamber of the Federal Office for Metrology and Surveying (BEV) [6]. Austrian Radon standard is a secondary standard, calibrated at PTB, Braunschweig (Germany). The calibrated Radon chamber is situated in a windowless, gastight cellar room. It is built of stainless steel panels to avoid electrostatic effects. The chamber is 11.4 m 2 and 27 m 3. The entire interior (tables, installations, air conditioning facilities) inside the chamber is made of stainless steel. The temperature inside the chamber was 21.71 o C and humidity 93.73%. 222 Rn source is provided by ARSENAL Research GmbH. The activity concentration of 222 Rn in chamber air was continuously surveyed by two AlphaGUARD PQ00PRO devices, manufactured by Genitron Instruments GmbH (Germany). The average activity concentration in the chamber air was 81 Bq/m 3. In order to study the influence of exposure geometry on the response of CR39 detector open exposure chambers of cylinder type with different diameters (2, 3 and 4 cm) and heights (2, 3, 4 and 5 cm) were prepared. Three detectors were exposed in each geometry, for 91 hours and minutes in the calibrated Radon Chamber. After the exposure of CR39 SSNTD in the calibrated Radon Chamber, all detectors were etched in a specially designed bath with stable etching solution temperature and blender (Radosys GmbH, Hungary). Etching solution was prepared with 4 liter of water and 1 kg of NaOH. Etching was performed at 90 o C for 4 hours and 15 minutes. In these conditions, we obtained the bulk etching velocity of 3.89 µm/h. CR39 response was read using RadoMeter 00 system. This system consists of a microscope and a controller computer. The microscope unit has a B&W CCD camera with 100 optical magnification. On each detector the microscope read one area about 47mm 2 divided in 12 12 fields. In Fig. 1 an image of one field obtained with this reading system is shown. Counted tracks are encircled in Fig. 1. Track shape is circular for normal

4 The response of CR39 SSNT radon detectors 379 incident particles, and has an elliptic shape for particles entering in the detector under an angle greater than the critical angle. From this image we can see that the reading system counts only tracks with the diameter in the range of 11 to 33µm; over-etched tracks are not counted. Fig 1 Image of one reading field obtained with Radosys reading system. 4. RESULTS AND DISCUSSIONS The track densities registered by the CR39 detectors exposed in the calibrated Radon Chamber were measured using the Radosys system. We observed that the track density depends on the geometry of the exposure chamber and on the material applied for coating the side walls of the chamber. In Fig. 2 the dependence of the track density on the diameter of the chamber is represented for various heights (5 cm, Fig. 2a; 4 cm, Fig. 2b; 3 cm, Fig. 2c; and 2 cm, Fig. 2d) of the chamber. In Fig. 3 the dependence of the track density as a function of chamber heights for diameters of 4 (Fig. 3a), 3 (Fig. 3b) and 2 cm (Fig. 3c) respectively, is represented. The non-linear dependences of track density on chamber geometry are explained by the opposite effect of track density variation due to the variation of the sensitive volume and to the variation of the contribution due to the plate-out effect. Both effects are sensitive to geometry modification. For example considering a chamber with constant diameter, the volume from where the alpha particles emitted by 222 Rn disintegration that can produce counted tracks decreases

380 Elena Robu et al. 5 with increasing the height of the exposure chamber. On the other hand, the contribution of tracks resulting from disintegration of the 222 Rn daughter particles deposited on the wall of the exposure chamber increases with chamber height. The magnitude of each type of variation depends on the diameter of the exposure chamber. Calibration factors obtained in these conditions for different exposure chambers are in the range from 4.24 10 +3 to 11.71 10 +3 [Bq m -3 h / mean density track mm -2 ]. 15 Height 5 cm 60 Height 4 cm 10 10 2 2. 2.5 2.75 3 3. 3.5 3.75 4 2 2. 2.5 2.75 3 3. 3.5 3.75 4 a b Height 3 cm Height 2 cm 2 2. 2.5 2.75 3 3. 3.5 3.75 4 c 2 2. 2.5 2.75 3 3. 3.5 3.75 4 Fig. 2 Track density for exposure chambers with heights of 5 (a), 4 (b), 3 (c) and 2 cm (d) as a function of chamber diameter for chamber wall coated with paper (rhombus), plastic (square) and aluminum (triangle). For quantitative explanation of these effects it is necessary to know the characteristics of the alpha particles (incident energy, angle of incidence) that lead to counted tracks in the exact conditions of this experiment (exposure, etching, d

6 The response of CR39 SSNT radon detectors 381 track counting using the Radosys instrument). These characteristics were established by simulation of track evolution during the development of the etching process using TRACK_TEST computer program developed by D. Nikezic and K.Yu [7, 4]. The program needs setup input data: alpha particle incident energy, angle of incidence, bulk etching velocity. The program permits visualization of the shape of the etched tracks and the assessment of the parameters (major and minor diameter, track length). 55 Diameter 4 cm 60 Diameter 3cm 55 2 2.5 3 3.5 4 4.5 5 height, cm Diameter 2 cm 15 a 2 2.5 3 3.5 4 4.5 5 height, cm b 10 2 2.5 3 3.5 4 4.5 5 height, cm c Fig. 3 Track density for exposure chambers with diameters of 4 (a), 3 (b) and 2 cm (c) as function of chamber height for chamber wall coated with paper (rhombus), plastic (square) and aluminum (triangle). In Fig. 4 the variation of the critical angle (in fact the cosine of the critical angle) as a function of alpha particle energy at the entrance of the exposed detector is represented. The critical angle represents the minimum incidence angle (with respect to the detector surface) that an alpha particle with given energy E should have when impinging on the detector in order to produce tracks that are counted.

382 Elena Robu et al. 7 0.8 0.75 0.7 0.65 cos (alpha) 0.6 0.55 0.5 0. 0.4 0. 0.3 4 4. 4.5 4.75 5 5. 5.5 5.75 6 6. 6.5 6.75 7 7. 7.5 7.75 Alpha particle incident energy, MeV Fig. 4 Critical angle variation as a function of incident alpha particle energy at the detector surface. For the future work we intend to develop a Monte Carlo simulation code similar to that previously reported [8,9], to be applied for the computation of the calibration factor in the specific conditions of this experiment. Acknowledgments. This work has been performed under the Sandwich Training Educational Programme of the International Center of Theoretical Physics Abdus Salam from Trieste, Italy. REFERENCES 1. D. Nikezic, K. N. Yu, Computer Simulation of Radon Measurements with Nuclear Track Detectors, (Ch. 3), in Computer Physics Research Trends, Editor: Silvan J. Bianco, Nova Science Publishers, Inc., pp. 119 1. 2. S. A Durrani, R. Ilic, Radon measurements by etched track detectors. Applications in Radiation Protection, Earth Sciences and Environment, World Scientific Publishing, Singapore, 1997. 3. S. A. Durrani, R. K. Bull, Solid State Nuclear Track Detection. Principles, Methods and Applications, Pergamon Press, Oxford, 1987. 4. D. Nikezic, K. N. Yu, Formation and growth of tracks in nuclear track materials, Materials Science and Engineering, R 46, 51 123 (04). 5. B. G. Cartwright, E. K. Shirk, P. B. Price, Nuclear-track-recording polymer of unique sensitivity and resolution, Nucl. Instr. Methods, 153, 1978, p. 7 460. 6. F. J. Maringer, Radon in Austria: metrology and practice, Kerntechnik, 73, 127 1 (08). 7. D. Nikezic, K. N. Yu, Computer program TRACK_TEST for calculating parameters and plotting profiles for etch pits in nuclear track materials, Computer Physics Communications, 174, 160 165 (06). 8. O. Sima, Computation of the Calibration factor for the cup-type SSNTD radon monitor, Rad. Meas.,, 603 606 (1995). 9. O. Sima, Monte Carlo simulation of radon SSNTD detectors, Rad. Meas., 34, 181 186 (01).