Expect more productivity

Similar documents
Thermo Scientific TSQ 8000 Evo Triple Quadrupole GC-MS/MS. Expect more productivity. with the evolution of ultimate performance GC-MS/MS

NOW YOU RE. Thermo Scientific TSQ 9000 Triple Quadrupole GC-MS/MS System

GC/MS/MS Dioxin and Dioxin-like PCBs in Feed and Food. Jessica Westland, LSAG Applications Chemist

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins

Multi-residue analysis of pesticides by GC-HRMS

Highly Sensitive and Rugged GC/MS/MS Tool

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Electron Ionization Source Parameters in GC-MS

NOW YOU RE. Thermo Scientific ISQ 7000 Single Quadrupole GC-MS System

Automated and accurate component detection using reference mass spectra

Analytical Instrumentation

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

T H E ANA LYSIS O F DIOX INS AND F U R A NS USING H RG C- H IG H R E SO LU T IO N MS W IT H T H E AU T OS P EC- ULTIMA NT

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Defining quality standards for the analysis of solid samples

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

Translational Biomarker Core

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

High Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

TOXICOLOGY & FORENSIC APPLICATIONS

The Truth About Dioxin Analysis: Using High Resolution GC-TOFMS and GCxGC-TOFMS to. Analytical Approaches

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Thermo Finnigan LTQ. Specifications

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Thermo Scientific TriPlus RSH Autosampler Integrated Sampling System. You are productive solving your chromatography challenges

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Determination of urea in ultrapure water by IC-MS/MS

Guide to Peptide Quantitation. Agilent clinical research

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Three-Fold Increase in Productivity for Pesticide Residue Analysis in Baby Food Using Fast Triple Quadrupole GC-MS/MS

ABI 3200 Q TRAP LC/MS/MS System

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

SIFT-MS. technology overview

Using Magnetic Sector GC-HRMS in a Commercial Dioxin Lab

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

110 Lowell Rd Hudson, NH USA Tel:

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Application Note GCMS-01 Comparison of Ionization Techniques for the Analysis of Trace-Level Pyrethroid Insecticides by GC-MS/MS

Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

high performance OPTIC 3 and applications a total analytical solution

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Compounding insights Thermo Scientific Compound Discoverer Software

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

Organochlorine Pesticides by GCxGC-ECD

U.S. EPA Method 8270 for multicomponent analyte determination

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

Implementing GC-HRAM MS for More Efficient and Effective Routine Pesticide Residues Analysis

WADA Technical Document TD2003IDCR

DI 3500 Discrete Aoalvzer

all suspects Identify Thermo Scientific Extractables & Leachables Workflow Unknown impurity identification and quantification workflows for:

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Gas Chromatograph Mass Spectrometer GCMS-TQ8050 C146-E326

for XPS surface analysis

Routine-grade robustness with the Advanced Electron Ionization source: confirmation of contaminants in food products at trace levels by GC-MS/MS

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Finnigan LCQ Advantage MAX

Gas Chromatograph Mass Spectrometer GCMS-TQ8040 C146-E251

Chapter 3: Development of a PTV-LVI-GC-MS/MS method

Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C

Overview. Introduction

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Advantages of Reversed Sandwich Injection for Pesticide Residue Analysis

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Food analysis. Solutions for Your Analytical Business Markets and Applications Programs

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Transcription:

Expect more productivity with the evolution of ultimate performance Thermo Scientific TSQ 8000 Evo triple quadrupole GC-MS/MS

Expect More Productivity Evolving with the changing laboratory environment The pressure on analytical laboratories has never been greater. Managers face a dynamic environment of changing regulatory requirements, lower detection levels, more compounds, less time, lower budgets and increased competition. Laboratories must evolve to stay ahead of the game, and their analytical systems need to evolve, too. The Thermo Scientific TSQ 8000 Evo triple quadrupole GC-MS/MS system is for labs looking for the next step up in triple quadrupole GC-MS/MS productivity. It is the latest evolution of the highly successful TSQ 8000 GC-MS/MS system and the evolution of unstoppable productivity, MS/MS simplicity, and ultimate performance SRM. The TSQ 8000 Evo triple quadrupole GC-MS/MS system has been designed for and developed with high throughput analytical laboratories. It is a unique system that offers a harmonious combination of hardware and software features that help laboratories adapt to their changing environment and deliver quality results on time, every time. 2

3

Expect More Capacity Fast EvoCell technology and intelligent instrument control More capacity is offered through the acquisition of more information, more compounds, and more results per unit time in your laboratory. This enables higher levels of productivity and efficiency in analytical workflows. Innovative EvoCell collision cell technology, in combination with the high efficiency timed-srm capability of the TSQ 8000 Evo GC-MS/MS system, opens the door to new possibilities for highcomplexity methods in routine laboratories. Enhanced velocity optics driving EvoCell collision cell technology provide high SRM transition speeds, precision, and sensitivity for even the most complex methods Bifenthrin Detection Limit (fg On Colum) 250 200 150 100 3.5x sensitivity at faster acquisition speeds Similar sensitivity at 4x transition speed 50 EvoCell Technology Older Cell Technology 0 0 100 200 300 400 500 600 700 800 900 Transition Speed (MRM/Second) Increased sensitivity at fast transition speeds allows the use of up to 4x transition speeds of standard collision cell technology 9 8 7 6 5 4 3 2 1 0 Chlorpropham Cyprodinil DDE,p Fludioxonil Folpet Furalaxyl Hexachlorobenzene Methiocarb Pirimicarb %RSD MDL (pg/ul) Calibration linearity (r 2 ) 5-500ppb Triadimenol Analysis of pesticides in rice (10 µg/kg) with the EvoCell collision cell at 500 µs dwell time, acquiring 800 transitions per second EvoCell Collision Cell Technology Features Benefits Impact Increased number of transitions per compound More points of confirmation More resistance to matrix interference Higher confidence More on-time results Increased number of compounds Higher capacity methods More method consolidation More efficiency in result production Fast GC compatible Faster run times Faster turnaround More on-time results 4 Wider SRM windows More resistance to the effects of RT shift caused by matrix Faster turnaround More on-time results

Truly powerful methods use speed efficiently As more compounds are added to a single run, managing acquisition windows becomes increasingly complex. The TSQ 8000 Evo GC-MS/ MS system dramatically reduces this complexity by automatically optimizing the targeting of a particular compound. Simply enter the retention time and the time required to capture the peak, and t-srm takes care of the rest. This ensures that compound detection is optimized for maximum sensitivity, and more compounds can be added to the method without compromising the excellent sensitivity of each individual analyte. The mass spectrometer is not consuming valuable resources scanning for compounds at the times when those compounds are not eluting. Multiple single quadrupole pesticides methods consolidated into one 40-minute, 350 pesticides (700 transitions) run Traditional Segmented SRM Complicated set-up Wasted dwell time Reduced sensitivity Reduced tolerance to RT shifts TSQ 8000 Evo GC-MS/MS system Timed SRM Automated set-up Optimized dwell time Maximized sensitivity Increased resistance to RT shifts Traditional Segmented SRM TSQ 8000 Evo GC-MS/MS system Timed SRM 5

Ultimate sensitivity SRM Laboratories performing analyses in food safety, environmental monitoring, and sports doping can all benefit from high selectivity and ultimate sensitivity selected reaction monitoring (SRM) enabled by the TSQ 8000 Evo GC-MS/MS system, which is the highest performing triple quadrupole GC-MS/MS system offered on the market. 1 TSQ 8000 Evo pesticide detection limits (1µL injection) Detection limit (99% confidence level) of 166 pesticides based upon 0.5 and 1 ppb peak area precision (no internal standard correction) using 1 µl PTV injection (n=10) parts-per-billion 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 2,3,5,6-Tetrachloroaniline Atrazine BHC, Alpha Bifenthrin Cadusafos Chlorfenson Chlorothalonil Chlorthal-monomethyl Cyfluthrin Cypermethrin DDE o,p Deltamethrin Dichlobenil Difenoconazole Diniconazole Endosulfan ssulfate Etaconazole Etofenprox Fenarimol Fenhexamid Fenvalerate Flucythrinate Flusilazole Furalaxyl Hexazinone Isocarbamid Linuron Methoxychlor Mevinphos Napropamide Oxadiazon Pentachloroaniline Phosalone Pirimicarb Propham Pyrifenox-Z Quintozene Tebufenpyrad Tetraconazole Tolclofos-methyl Triallate Triticonazole The TSQ 8000 Evo GC-MS/ MS system is a perfect fit for laboratories in need of high efficiency pesticide methods. Enhanced selectivity, speed, and sensitivity translate into real routine efficiency and productivity. Expect performance above and beyond former triple quadrupole instruments. DDE p,p 5 µg/kg in green tea DDE p,p Calibration Curve 5-500 µg/kg in green tea Oxyfluorfen 5 µg/kg in green tea Oxyfluorfen Calibration Curve 5-500 µg/kg in green tea 6 High selectivity of low concentrations in complex tea matrix

Expect More Performance Ultimate sensitivity for contaminants regulated at the lowest levels The confirmatory determination of polychlorinated dibenzodioxins and furans (PCDD/Fs) is one of the most challenging of the ultra-trace analytical methods in contaminant analysis. This challenge is due to the extremely low regulated levels and stringent analytical criteria in force. Meeting that challenge requires extremely powerful SRM that the TSQ 8000 Evo GC-MS/MS system delivers routinely. Fish meal 0.03 ng/kg 88% dw 2,3,7,8-TCDD 319.89 > 256.93 2,3,7,8-TCDD 321.89 > 258.93 13C 2,3,7,8-TCDD 331.94 > 267.97 Fish meal containing low levels of 2,3,7,8-TCDD 13C 2,3,7,8-TCDD 333.93 > 269.97 0.1 0.09 Concentration [pg/µl] 0.08 0.07 0.06 0.05 0.04 0.03 Instrument detection limit (IDL) for PCDD/Fs when satisfying all confirmatory criteria CSL x 5 dilution (n=10) injected using splitless mode 0.02 0.01 0 2378-TCDF 2378-TCDD 12378-PeCDF 23478-PeCDF 12378-PeCDD 123478-HxCDF 123678-HxCDF 234678-HxCDF 123478-HxCDD 123678-HxCDD 123789-HxCDD 123789-HxCDF 1234678-HpCDF 1234678-HpCDD 1234789-HpCDF OCDD OCDF European Commission GC-MS/MS Confirmatory Performance Criteria TSQ 8000 Evo GC-MS/MS system Capabilities Compliance Confirmed Two specific precursor ions with two specific production ions All recommended methods developed as defined in criteria Fully optimized by AutoSRM Yes Tolerance of ion ratios within ± 15% < 10% measured at EPA 1613 CSL level (n=14) Yes Resolution of each quadrupole equal to or better than unit mass resolution All recommended methods developed Q1 and Q3 at 0.7 Da Yes The % RSD of the five (or more) Relative Response Factors (RRFs) for each unlabeled PCDD/PCDF and labelled internal standards must not exceed 20% 6 point curve EPA 1613 CSL-CS4 2% Yes 7

Expect More Robustness Unstoppable productivity The Thermo Scientific ISQ Series single quadrupole GC-MS system and TSQ 8000 triple quadrupole GC-MS/MS system have a strong reputation in allowing laboratories to tackle the demands of producing results on time, every time. The TSQ 8000 Evo triple quadrupole GC-MS/MS system continues that legacy by enabling routine-grade robustness for ultimate performance applications in some of the most challenging matrices. The patented Thermo Scientific ExtractaBrite ion source is heated throughout and includes the first RF region (RF lens), commonly the first place susceptible to ion burn. This design ensures high matrix tolerance for high throughput applications. Crucially, it is fully removable, even when hot, under vacuum for necessary cleaning or swapping with a spare source. There is never a need to vent to clean your instrument or to heat or clean quadrupoles. Enjoy constant productivity. pg/µl 100 Robustness Cold Pressed Orange Oil (external standard calibration) 75 50 25 Biphenyl (3.6% RSD) Ortho-phenylphenol (3.7% RSD) Butylated hydroxyanisole (4.2% RSD) Phorate (3.1% RSD) Tetrahydrophthalimide (4.7% RSD) 0 1 6 11 16 21 26 31 36 41 46 51 56 66 61 71 76 81 86 91 96 Injection # Robustness of 1:20 diluted orange oil spiked with pesticides and injected directly (n=100) 14 Before 14 After 12 12 10 10 8 % RSD 8 6 4 2 0 Dichobenil Tribromoanisol Sulfotep HCB Parathion Iprodion EPN Azinphos-Methyl Pemethrin Deltamethrin %RSD pesticides (10 ppb) before and after 1,400 vegetable matrix injections % RSD 8 6 4 2 0 Dichobenil Tribromoanisol Sulfotep HCB Parathion Iprodion EPN Azinphos-Methyl Pemethrin Deltamethrin

Expect More Flexibility Flexibility to best solve your analytical challenge The TSQ 8000 Evo GC-MS/MS system addresses many laboratory mass spectrometry needs through various scan modes along with source and probe options. Excellent performance is enabled for single quadrupole-type scan modes which, in turn, expand system versatility in the modern laboratory. Mode Q1 Q2 (EvoCell) Q3 Application Selected ion monitoring (SIM) Transmission only Transmission only Selected m/z Target quantitation Full scan Transmission only Transmission only Scanning Unknown ID, library search Selected reaction monitoring (SRM) Selected m/z CID Selected m/z Target quantitation Product ion scan Selected m/z CID Scanning SRM method development and compound elucidation, build and search libraries Precursor ion scan Scanning CID Selected m/z Searching for unknown compounds giving characteristic fragments Constant neutral loss Scanning CID Scanning (- neutral loss offset) Searching for unknown compounds with common structures, e.g. acids SRM/Full Scan Alternating selecting m/z and transmission only Alternating CID/ Transmission only Alternating selecting m/z and scanning Target quantitation and unknown ID by library search Ion sources and probes are removable without requiring a break in the vacuum, and they enable you to perform MS and MS/MS experiments on solids in real time while effortlessly switching between electron ionization (EI) and chemical ionization (CI). Direct Insertion Probe (DIP) Slower volatilization with heated capillary tube for solid samples. The DIP can be utilized for rapid analysis of solids or trace components in solid matrices such as forensic samples, tissue, etc. Direct Exposure Probe (DEP) Rapid heating filament for liquids or solutions. The DEP is ideal for rapid molecular weight confirmation of solids dissolved or suspended in a suitable solvent. Chemical Ionization Chemical ionization is a softer form of ionization than electron ionization (EI). It offers a greater opportunity to generate more abundant high mass and molecular ions and a higher degree of selectivity or sensitivity in the source ionization process, especially with negative chemical ionization (NCI), favoring electronegative compounds, such as halogenated species. Chemical ionization is ideally used for structure elucidation also in MS/MS mode. 9

brilliant Design for brilliant Results Remove the Source of your Downtime Allows full source removal without venting the MS including ion guide surface. No wire connections are necessary, and venting is never necessary to clean your instrument. Never Clean or Replace Quads Heated ion guide protects the main quadrupole sets so they never require cleaning or replacement. ExtractaBrite wireless ion source cartridge Dual Heated Zones on Source Maximize Ruggedness Dual independently-heated zones on the TSQ 8000 Evo system allow for thousands of injections of the dirtiest matrices before source cleaning is required. 10 Dual Filaments for Prolonged Uptime Intelligent dual filament design keeps you running longer between maintenance intervals. No Noise is Good Noise Off-axis optics provided by the curved ion guide effectively eliminate neutral noise, resulting in less background and lower limits of detection.

Industry-Leading Detector Linearity The Thermo Scientific DynaMax detection system standard on the TSQ 8000 Evo system offers industry-best linearity. Combined with the low detection limits attainable by SRM, this detector makes the mass spectrometer the ultimate quantitative instrument. EvoCell Collision Cell Technology High performance SRM at high velocity transition speeds. Switch Between Full Scan, SIM and MRM in Milliseconds Effortless switching is made possible with the fast scanning capabilities of the TSQ 8000 Evo GC-MS/MS system. No Helium Required Choose between nitrogen or argon for collision gas. No expensive helium is required. Fast Scanning Allows Fast Chromatography Dynamic ion expulsion in the collision cell allows hundreds of MRM transitions per second. Combined with t-srm for efficiently managed transition scheduling, the TSQ 8000 Evo system can analyze hundreds of compounds with multiple transitions each over short chromatographic runs. On-Axis (in-line) Optics noise reduced to ~2 ions/sec 11

Expect More Simplicity Easy MS/MS The advantages of selected reaction monitoring (SRM) and multiple reaction monitoring (MRM) analysis often come with challenges, especially with respect to adoption of new technology in the laboratory. These challenges are due to the method set-up and optimization and management of complex analytical methods. Laboratories that strive to realize the benefits of MS/MS must overcome some barriers in the tuning, set-up and optimization to reduce the time required to achieve a smooth operating routine. The TSQ 8000 Evo GC-MS/MS system was built to guarantee an easy start-up. Whether you are managing retention times, starting a completely new analysis, transferring a method from a single quadrupole system, or porting a known MRM method from another instrument, the TSQ 8000 Evo system ensures the fastest route to routine high performance results through its integrated software tools. AutoSRM: A purpose-built software for automated SRM method creation and optimization from full scan to the complete analytical method setup TSQ 8000 Evo GC-MS/MS Instrument Method: Offers true timed-srm operation, allowing for high sensitivity and ease of use for the most complex SRM methods Thermo Scientific TraceFinder Software: State of the art, multi-platform user-friendly chromatography analysis software From the Start For new compounds, choose to begin the AutoSRM function, ask for a precursor ion study (Step 1), and place a vial with the compound mix in the autosampler. The AutoSRM function reports a full scan chromatogram of the injection, and you simply identify your peaks and choose the most appropriate precursors that AutoSRM presents. In the case of coeluting compounds, AutoSRM automatically performs one injection per compound. From an Existing SIM Method If you are moving from a single quadrupole GC-MS method using SIM analysis, or you already know which ions you want to select for your precursor ions, you can start with Step 2. The AutoSRM function performs product ion scans for each selected precursor and presents the results in a single window. Simply select (or ask AutoSRM to select) the best product ion for that compound. SRM Optimization Method Sync AutoSRM TSQ 8000 Evo Instrument Method 12 From a Previous MS/MS Method If you have already performed previous AutoSRM steps or are simply moving from another MS/MS system, then Step 3 can take you to the final fully optimized SRM transitions for your compounds. Fully automated collision energy optimization is performed to ensure that transitions are as sensitive as they can be. These optimized SRM transitions are then exported into a finished MRM method ready for analyzing real samples in routine. TraceFinder Software

Your Starting Point AutoSRM Workflow Step 1: Selects your precursor ions from full scan Unknown SRM transitions Start from the very beginning Start with existing SIM method Step 2: Selects your product ions from product ion scans Known SRM transitions From an existing method From SRM transition list Step 3: Optimizes the collision energy for selected transitions Optimized SRM transitions From Compound Data Store From existing GC-MS/MS method 13

Be More Productive Fast, flexible, easy-to-use mass spectrometry software The challenge The constant pressure to increase productivity challenges laboratory staff at every level, from the technician to management. Streamlined, workflow-driven software solutions are needed to address these challenges. At the same time, the growing list of compounds that laboratories must quantify and screen, combined with increasingly complex regulatory requirements, necessitate flexible method development and powerful reporting tools. TraceFinder software is the solution TraceFinder software makes routine quantitation simple, fast and productive. It offers a complete solution that can be used to develop methods, acquire and process data, and generate standard and customized reports with the full portfolio of Thermo Scientific mass spectrometers. Powerful method development TraceFinder software provides powerful tools for method developers, including: Compound databases (CDB) for rapid selected reaction monitoring (SRM) method development User-defined flags for nearly every parameter Automated retention time and ion ratio adjustment Compound Database contains hundreds of compounds and parameters for SRM work flows, allowing rapid method development 14 Simple, full-featured data review TraceFinder software offers simple, yet exceptionally feature-rich data review capabilities. The intuitive, workflow-driven arrangement of information simplifies the technician s role in reviewing data. The technician can quickly and easily observe the data processing status, view compound-related flags to locate compounds which need attention, and take appropriate steps to address any problems. Powerful, automated reporting The new TraceFinder software report designer offers enhanced laboratory productivity with customizable, automated reporting with numerous standard report templates.

Leading the way in regulatory POPs quantitation Thermo Scientific TargetQuan 3 software is uniquely tailored for a workflow-orientated POPs quantitation, like PCDD/Fs, PCBs, PBDEs and others. This software package is designed specifically to serve laboratories charged with performing routine quantitation of POPs in a regulated environment. With TargetQuan 3 software, comprehensive processing of MS, MS/MS and HRMS data is possible on a single software platform, compliant with the US EPA 1613 requirements. 15

Experience More innovation Tackle future challenges through GC modularity Example of plug-in module installation by user Enable Quick Customization with GC Modularity Tailor the Thermo Scientific TRACE 1300 Series GC system to your needs with its proprietary user-exchangeable Instant Connect injector and detector modules. Swapping modules is easily done by the removal and replacement of three screws, accessible from the top of the GC. The entire process takes less than five minutes without requiring specialized service assistance. This enables budget-conscious laboratories to purchase a base-configured GC today, then easily expand their capabilities to accommodate new application and throughput demands. T: 2.01-13.60 100 90 80 70 60 50 40 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 GC and GC-MS Operating Conditions* Around the Clock Analysis 24 hours a day, 7 days a week, 365 days a year Daily Operations Leaving the GC idle at the end of workdays and on weekends Conventional Operation 6.86 Estimated Cylinder Lifetime With the Instant Connect Helium Saver Module 5 months 3.5 years 15 months 14.6 years * Conditions: Operating a TRACE 1300 Series GC system with helium at 4 ml/min (sccm) using a typical helium cylinder of 48 L volume at 2250 psig. 3.51 4.28 11.52 9.23 4.58 11.22 9.03 7.93 12.71 6.29 5.30 7.88 5.20 3.85 4.69 5.68 3.56 7.00 6.11 6.48 7.40 3.26 5.36 8.45 9.88 7.04 5.05 7.47 8.09 9.81 3.95 10.86 5.97 5.47 13.05 7.67 11.56 2.58 7.12 10.77 2.78 8.18 8.53 9.62 4.97 12.01 2.52 3.22 12.18 13.19 6.81 10.28 10.25 11.19 9.19 12.63 8.98 11.45 11.17 4.55 7.84 7.89 6.25 5.16 5.26 5.63 6.06 6.44 6.95 7.42 4.66 8.05 8.41 3.54 4.49 12.95 3.48 3.66 5.32 7.35 7.62 4.25 9.77 5.46 3.82 5.93 6.57 10.81 5.01 9.33 9.84 3.37 11.50 7.00 4.15 3.24 7.08 2.57 10.72 2.77 2.15 3.19 8.48 9.58 10.39 8.11 11.94 4.94 12.10 5.0 2.5 3.0 3.5 4.0 4.5 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 Time (min) Using the Instant Connect Helium Saver Module, results from US EPA Method 8270C (semi-volatiles) remain unchanged 10.32 11.25 Ensure Uninterrupted Analyses and Save Budget by Conserving Helium The helium shortage continues to inflict price pressure and supply uncertainty on laboratories that require these gas supplies to perform their research and analyses. Realizing the importance of finding a safe, cost-effective solution, the proprietary Instant Connect Helium Saver Module has been introduced to drastically reduce helium carrier gas consumption and extend helium cylinder lifetime up to 14 years per instrument, without any GC or GC-MS method modifications. Helium is continuously saved, both while the GC is in operation and while it is idle. Previously acquired retention times remain unchanged, and no method revalidation is required. Backflush and Large Volume Capabilities The capabilities of the Instant Connect injector modules are further enhanced by the available concurrent backflush options. These solutions enable the user to reverse the flow inside the injector, eliminating heavy or undesired compounds concurrently during the analysis run, protecting the column and detector while cutting down non-productive times, thus increasing throughput. Instant Connect-SSL concurrent backflush. The T-piece for column connections and its carrier gas control are integrated within the module Find out more at thermofisher.com/tsq8000evo 2017 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR10376-EN 0317S