Metabolomics of Opiate-Induced Changes in Murine Brain by GC/Q-TOF

Similar documents
Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Analysis of Extractable and Leachable (E&L) Compounds Using a Low-Energy EI-Capable High Resolution Accurate Mass GC/Q-TOF

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

MassHunter TOF/QTOF Users Meeting

Identifying Disinfection Byproducts in Treated Water

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Agilent All Ions MS/MS

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

MassHunter Software Overview

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

Metabolic Phenotyping Using Atmospheric Pressure Gas Chromatography-MS

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Extend Your Metabolomics Insight!

Die Nadel im Heuhaufen

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Application Note. Authors. Abstract. Introduction. Environmental

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

The new Water Screening PCDL

Compounding insights Thermo Scientific Compound Discoverer Software

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

WADA Technical Document TD2003IDCR

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Making Sense of Differences in LCMS Data: Integrated Tools

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Multi-residue analysis of pesticides by GC-HRMS

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Author. Abstract. Introduction

Automated and accurate component detection using reference mass spectra

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Agilent METLIN Personal Metabolite Database and Library MORE CONFIDENCE IN COMPOUND IDENTIFICATION

Pharmaceutical Impurity Identification and Profiling Using Agilent Q-TOF LC/MS Combined with Advanced MassHunter Data Processing Software

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Welcome! Course 7: Concepts for LC-MS

Application Note. Edgar Naegele. Abstract

Agilent G3212 GC-APCI Source

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Agilent Technologies at TIAFT 2013

Metabolomics in an Identity Crisis? Am I a Feature or a Compound? The world leader in serving science

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Supplementary Materials: Model-based peak alignment of metabolomic profiling from comprehensive two-dimensional gas chromatography mass spectrometry

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry

GC-CI-MS analysis of TMS derivatives

profileanalysis Innovation with Integrity Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research

Highly Sensitive and Rugged GC/MS/MS Tool

MRMS axelerate rapidly detected micropollutants and plant response metabolites in poplar leaves

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

WALKUP LC/MS FOR PHARMACEUTICAL R&D

C Glucose Qualitative Flux Analysis in HepG2 cells

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Agilent 5977A Series GC/MSD System

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

What s New in NIST11 (April 3, 2011)

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Quantitation of Cystine and Identification of Related Metabolites in White Blood Cells Using a High Resolution Accurate Mass LC/MS Approach

U.S. EPA Method 8270 for multicomponent analyte determination

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Cerno Application Note Extending the Limits of Mass Spectrometry

Theory and Practical Consequences.

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Agilent Technologies LCMS Portfolio

ANALYTICAL REPORT. 25B-NBOH (C17H20BrNO3) 2-({[2-(4-bromo-2,5-dimethoxyphenyl)ethyl]amino}methyl)phenol RSUNJYKZRKIBNB-UHFFFAOYSA-N

MetWorks Metabolite Identification Software

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

QTOF-based proteomics and metabolomics for the agro-food chain.

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Using the ACD/MS Manager Software with Agilent 1100 Series LC/MS Systems. Application Note

Untargeted Screening on the X500R QTOF

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Metabolomics Workflow. Discovery Workflow Guide

WADA Technical Document TD2015IDCR

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Agilent MassHunter Quantitative Data Analysis

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Transcription:

Metabolomics of Opiate-Induced hanges in Murine Brain by G/Q-TOF Application Note Metabolomics Authors Manhong Wu, Ming Zheng, David lark, and Gary Peltz Department of Anesthesia School of Medicine Stanford University Stanford, A Peyman Sahbaie Veterans Affairs Palo Alto Healthcare System Palo Alto, A Abstract A study was performed to elucidate opiate-induced metabolic changes in murine brain. The EI MS, EI MS/MS, and PI capabilities of the Agilent 7 Series G/Q-TOF MS, in combination with Agilent MassHunter Software tools, enabled a very flexible and comprehensive workflow for identifying metabolomic differences. The workflow was used to distinguish between morphine-sensitive and resistant murine strains, determine differences in their response to morphine administration, and identify compounds using various techniques. Sofia Aronova and Stephan Baumann Agilent Technologies, Inc. Santa lara, A

Introduction Metabolomics is a powerful approach for investigating the biochemistry of morphine addiction, as it provides the most direct information about a system s physiological state. There is currently very little information available regarding metabolomic changes that mediate neurobehavioral responses. It is likely that clinically important opiate responses could be mediated by opiate-induced metabolomic changes. This application note describes a study that employed an untargeted metabolomics approach using gas chromatography/mass spectrometry (G/MS) to characterize opiate-induced metabolic changes in murine strains that display drastically different levels of sensitivity to morphine. The Agilent 7 G/Q-TOF was used in order to take advantage of the accurate mass information, full spectrum sensitivity, MS/MS capabilities, and both EI and I modes. This approach was combined with the full featured capabilities of Agilent MassHunter and Agilent Mass Profiler Professional (MPP) software to enable identification and confirmation of metabolites whose levels were changing in these murine strains. It was of particular interest to identify inter-strain differences in metabolite levels that happened in response to morphine administration, since these changes help in understanding the mechanism of morphine addiction. This metabolomics study revealed a significant change in adenosine levels between control and morphine administration in a morphine-sensitive murine strain. We also observed changes in the levels between the two strains for a few other metabolites, including adenosine 5 -monophosphate, glyceric acid, cholesterol, and the neurotransmitter N-acetylaspartylglutamic acid. Experimental Materials 57BL/6 and 19Sv1 murine strains (males, 7 8 weeks old) were obtained from Jackson Laboratories (Bar Harbor, ME). Morphine was obtained from Sigma hemicals (St. Louis, MO). Instruments This study was performed on an Agilent 789B G system, coupled to an Agilent 7 G/Q-TOF system. The instrument conditions are listed in Table 1. Table 1. G run conditions olumn G and Mass Spectrometer onditions Injection volume 1 µl Split mode ratio Inlet temperature 5 Oven temperature program arrier gas Transfer line temperature 9 MS conditions Ionization mode Source temperature 3 Quadrupole temperature 15 Mass range Spectra acquisition rate Agilent DB-5 MS Ultra Inert, 3 m.5 mm,.5 µm film (p/n 1-553UI) Split 1:1 (EI) and Splitless (PI and MS/MS) 6 for 1 minute, 1 /min to 35, 3.5 minutes hold Helium at 1 ml/min constant flow EI, positive I (% methane flow) 4 to 6 m/z 5 Hz, collecting both in centroid and profile modes

Sample preparation Mice were administered either with morphine for four consecutive days, or with saline control over the same period of time. Brainstem tissue was collected from eight week old male 57BL/6 (morphine-sensitive) and 19Sv1 (morphine-resistant) mice in seven to eight biological replicates. Metabolites were extracted by the Folch method [1]. The aqueous fraction was collected, dried under vacuum, and subsequently derivatized by methoximation using a saturated solution of hydroxylamine Hl in pyridine followed by silylation with N-Methyl-N-(trimethylsilyl) trifluoroacetamide (MSTFA) and 1% trimethylchlorosilane (TMS). Data processing and statistical analysis The data were processed by chromatographic peak deconvolution using the Unknowns Analysis tool from MassHunter Quantitative Analysis Software package, followed by compound identification by comparison to the Agilent Fiehn G/MS Metabolomics Retention Time Locked (RTL) Library. Molecular Structure orrelator (MS) software was used to further validate the structures of tentatively identified compounds. Statistical analysis was performed by Mass Profiler Professional (MPP), a multivariate statistical analysis package. It was used to visualize data clustering as well as to determine significant differences in compound abundance levels between pairs-wise conditions. Results and Discussion hromatographic peak deconvolution and library search hromatographic peak deconvolution using the Unknowns Analysis tool was able to find approximately 7 components in each sample (Figure 1). The corresponding hits were assigned using the Agilent-Fiehn metabolomics MS library with a Match Factor score > 5 for approximately 7 1 components in each sample. After all the components that did not display significant changes were filtered out in MPP, the unidentified components, as well as those identified by the Agilent-Fiehn library were searched against the NIST MS library for confirmation and identification of the components not present in the Agilent-Fiehn library. Some of the abundant components that did not have a good match in either library but did display significant changes, were taken through additional analysis steps such as elucidation of the empirical formula using PI and EI MS/MS, as well as proposal of a structure using accurate mass information and the Molecular Structure orrelator (MS) software tool, as will be described later. Figure 1. The Unknowns Analysis tool was used to perform deconvolution and the initial library search. The lower right-hand panel shows deconvoluted ions of the component that have the same peak shapes, thus confirming that they all belong to the same component. 3

Approximately 6 metabolites previously identified in each sample using the Agilent-Fiehn unit mass metabolomics library were confirmed using accurate mass information. This allowed us to rule out any false positives. The Fragment Formula Annotation (FFA) tool in MassHunter Qualitative Analysis Software was combined with library search results to enable easy confirmation of an identified compound (Figure ). A fragment is annotated and colored green when the formula of the fragment is a subset of the molecular formula identified by a library search. This is useful for rapid confirmation of the compound identity (Figure ). The majority of identified metabolites represented amino acids, organic acids, and carbohydrates (Figure 3). Statistical analysis workflow Analysis of metabolomics data is often a tedious and time-consuming process. MPP software is ideal for filtering, interpretation, sample model creation, and prediction; this is required to efficiently evaluate complex and noisy data. MPP provides an easy-to-follow workflow that helps the user decide how best to evaluate their data. For more sophisticated users, MPP also provides access to different statistical operations, and users can treat their data in many different ways in order to optimize their data analysis (see the Mass Profiler Professional brochure 599-4164EN for further details). ounts 1 4 1.9 73.465 1.8 [3 H9 Si]+ 1.7 1.6 1.5 1.4 1.3 1. 1.1 1.9.8.7.6.5.4.3..1 Figure. 19.687 [6 H14 N O4 Si]+ 169.69 [8 H13 O Si]+ 36.95 [9 H14 N5 O Si]+ 8.1393 [1 H6 N O4 Si]+ 348.1363 46.81 [16 H N3 O4 Si]+ [14 H N5 O4 Si3]+ 54.31 [1 H4 N5 O4 Si4]+ 6 8 1 1 14 16 18 4 6 8 3 3 34 36 38 4 4 44 46 48 5 5 54 56 58 Annotated spectrum of one of the compounds (adenosine) using FFA in Agilent MassHunter Qualitative Analysis. When the library hit was found, FFA automatically recognized the molecular ion (MI), and, based on the empirical formula of the hit and accurate mass spectral data, it assigns fragment formulas. These annotated ions are colored in green. Whenever a good match for an ion fragment cannot be found, the ions from the spectrum have the original color (red). Si Si O O O Si O N N N N H N Si Organic acids Amino acids arbohydrates Lipids Nucleic acid metabolism Other Figure 3. Distribution by metabolite class of the 6 compounds identified using the Agilent-Fiehn library. 4

Once deconvolution was completed in Unknowns Analysis, compound information was saved in an xml-based, compound exchange file format (.EF). These files were imported into MPP to determine which compounds had significant changes in their abundance levels between pairs of conditions or murine strains. An important part of the MPP workflow is a correct setup of the compound filters to ensure that a significant proportion of the noise in the data is filtered out. This is so that it does not interfere with statistical analysis. The inherent degree of variance in the data was evaluated using Principal omponent Analysis (PA) (Figures 4 and 5), followed by significance and fold-change analysis visualized by Volcano Plots (Figures 6 and 7). Evaluation of data using Principal omponent Analysis PA is a frequently employed unsupervised multivariate statistical analysis technique for data dimensionality reduction. It is performed through the transformation of measured variables into uncorrelated principal components, each being a linear combination of the original variables. Figures 4 and 5 show representative examples of PA analyses. The PA plots reveal clear separation between control and morphine-administered groups, as well as separation between the two murine strains. Y-axis 1-1 - - -1 1 1 1 1-1 - -3 Y-axis -1 1 5-5 -1 olor by treatment ontrol Morphine 1 5-1 1-15 X-axis - -5 - X-axis -1-1 -1-15 -1 1 olor by strain 19Sv1 57BL/6-1 Figure 4. 1-1 - Z-axis PA of control versus morphine-treated mice in the 19Sv1 strain confirms the existence of two distinct clusters. Eight biological replicates (mice) were analyzed for each condition (control, red; morphine, blue) in the clustering analysis. A similar plot was obtained for the 57BL/6 strain. Figure 5. 1-1 - Z-axis PA of an inter-strain comparison without morphine administration, showing two distinct clusters. Eight biological replicates (mice) were analyzed for mouse strain (19Sv1, red; 57BL/6, blue) in the clustering analysis. A similar plot was obtained comparing the same strains after morphine administration. 5

1. 1. Adenosine 5 -log1 (corrected Pvalue).8.6.4 -log1 (corrected Pvalue) 15 1. 5 1 5 log (fold change) 5 1 1 log (fold change) 1 Figure 6. Volcano plot of fold change in concentration versus probability value for morphine-treated versus control morphine-sensitive mice (57BL/6). The level of adenosine is decreased in morphine-administered mice as compared to control in the 57BL/6 strain (p <.5), and it is the only compound whose level changes significantly between the two conditions. The green lines indicate cutoff values of p =.5 (vertical axis) and a fold change of 1.5 (x-axis). Figure 7. Volcano plot of fold change in concentration versus probability value for morphine-sensitive (57BL/6) versus morphine-resistant mice (19Sv1). The levels of 1 compounds significantly differ between the two strains (p <.5). The green lines indicate cutoff values of p =.5 (vertical axis) and a fold change of 1.5 (x-axis). Metabolite Fold hange Analysis Following PA, Fold hange (F) analysis was performed on morphine-treated and control samples for both morphine-sensitive and resistant mice (57BL/6 and19sv1, respectively). Initially, the magnitude of a biologically significant fold change in the concentration of any given compound between conditions and murine strains was determined. This analysis resulted in the identification of compounds (entities) with substantial abundance differences between the selected classes. Next, in order to determine if the differences found between the evaluated pairs of conditions or strains by fold change were statistically significant, a series of t-tests was performed. The results of fold change analysis and statistical significance are displayed in a Volcano Plot. In a comparison between morphine-treated and control samples for 57BL/6 (morphine-sensitive) mice, we noticed that adenosine was the only compound that showed a statistically significant change: a reduction in concentration for morphine-administered mice as compared to control (p-value <.5; Figure 6). In contrast, a comparison of 57BL/6 and 19Sv1 mice in the absence of morphine treatment revealed a number of compounds (including adenosine, adenosine 5 -monophosphate, glyceric acid, cholesterol, neurotransmitter and N-acetylaspartylglutamic acid) with significant fold changes at a p-value <.5 (Figure 7), indicating significant metabolic differences between the two murine strains. 6

Empirical formula determination of an unknown using EI MS/MS and PI The combination of accurate mass/high resolution information with Molecular Formula Generation (MFG) using the FFA tool in MassHunter Qualitative Analysis helped identify possible formulas for the fragments. However, the molecular ion is often uncertain in EI, making it difficult to confirm the correct annotation and narrow down the class of the compound. One of the advantages offered by the use of the accurate mass 7 G/Q-TOF system is its ability to obtain additional information through the use of MS and MS/MS, with PI and EI ionization techniques. One example in this study was an unknown compound eluting at 1.34 minutes that accumulated after morphine administration in the morphine-resistant 19Sv1 murine strain relative to the control, but did not show significant changes in its levels in the morphine-sensitive strain (Figure 8). An MS/MS experiment can be performed on the ions generated in the EI scan in order to identify product ions of abundant precursor ions in the EI spectrum and, therefore, distinguish possible interferences. In this way, one can easily filter out interfering ions with relatively high m/z. Figure 9 illustrates that ions at m/z 19.1 and m/z 7.88 are not product ions of m/z 8.665, that was used as a precursor ion. In fact, abundances for the 19.1 and 7.88 m/z ions differed between the two murine strains, but the abundances of the ion at m/z 8.665 and its product ions did not, suggesting that the m/z 8.665 ion might belong to a different compound that coelutes with the unknown. Thus, MS/MS helped distinguish interferences in the spectrum. 1 5.8.6.4. 1.8 1.6 1.4 1..8 1.6.4. ounts Figure 8. 7.88 [ 4 H 1 N 19.1 [ 6 H 13 N O 86.963 58.91 [ 5 H 1 N 11.1 8.665 [ [ 13 H 1 NO 3 ] [ + H 6 O 5 158.1419 7.835 33.798 H 4 NO [ 8 H 18 N O [ [ 9 H N 4 O 4 Si 3 8 H 16 N 5 O Si 5 6 7 8 9 1 11 1 13 14 15 16 17 18 19 1 3 4 5 6 7 8 9 3 31 3 33 34 35 EI spectrum of the unknown peak eluting at 1.34 minutes, which accumulates in the morphine-treated 19Sv1 mice. The spectrum is annotated using the MFG tool of Agilent MassHunter Qualitative Analysis Software. ounts 1 5.8.6.4. 1.8 1.6 1.4 1..8 1.6.4. Figure 9. EI full scan 7.88 [ 4 H 1 N 1 4 EI MS/MS, selecting ion 8, E 5 ev. 73.463 1.8 1.6 1.4 1. 8.651 1.8 11.3.6 4.33.4 136.196 1.9995. 58.37 91.614 184.345 4 6 8 1 1 14 16 18 4 6 19.1 [ 6 H 13 N O ounts 86.963 58.91 [ 5 H 1 N 11.1 8.665 [ [ [ 13 H 1 NO 3 H 6 O 5 158.1419 7.835 33.798 H 4 NO [ 8 H 18 N O [ [ 9 H N 4 O 4 Si 3 8 H 16 N 5 O Si 5 6 7 8 9 1 11 1 13 14 15 16 17 18 19 1 3 4 5 6 7 8 9 3 31 3 33 34 35 MS/MS performed on the Agilent 7 G/Q-TOF system can be used to find contaminating compounds in a peak of interest. In this case, the two ions in the spectra having the highest abundance (m/z 7.88 and m/z 19.1) are clearly not derived from ion 8.665 m/z, possibly making it a contaminant. This hypothesis was confirmed by tracking the changes in the abundance of these ions when comparing morphine-treated versus control conditions. 7

PI in MS mode, using methane as a reagent gas, was then used to identify the molecular ion as the m/z 158.1419 ion, for which there were methane adducts that help confirm the molecular formula ( 8 H 19 N O; Figure 1). The high isotope abundance score and isotope spacing score increased confidence in the identification. Having an accurate empirical formula was one of the first steps in compound identification workflow, and it also helped determine if the compound was of interest, or outside the focus of the study, as it was in this case. ounts 1 5.6.4. 1.8 1.6 1.4 1. 1.8.6.4. Figure 1. 159.1496 ([8H18NO]+H)+ 187.1797 ([8H18NO]+H5)+ 179.815 164.111 19.799 199.181 ([8H18NO]+3H5)+ 156 158 16 16 164 166 168 17 17 174 176 178 18 18 184 186 188 19 19 194 196 198 Methane PI spectral data on the unknown compound eluting at 1.34 minutes confirms that the molecular ion is m/z 158.1419, and the high mass accuracy, isotope abundance, and isotope spacing scores increase confidence in the identification. After performing MFG with FFA, the PI spectrum shows typical PI methane adducts of m/z 158.1419: 159.1496 (M+H)+, 187.1797 (M+ H 5 )+, and 199.181 (M+ 3 H 5 )+. The theoretical isotopic spacing abundance is overlaid in red. The tabular results of the FFA workflow are shown above the spectrum. 8

Validating the structure of a tentatively identified compound using the Molecular Structure orrelator tool Since a-hydroxyglutaric acid, accumulated in morphine-sensitive strain 57BL/6, was tentatively identified using the NIST library but not the Agilent-Fiehn RTL library, we took additional steps to confirm the identity of this compound. First, using accurate mass information of the EI spectrum and the MFG tool of MassHunter Qualitative Analysis, we verified the consistency between the empirical formula of a-hydroxyglutaric acid and the annotated fragment ions (Figure 11). MS software was used to further validate the structure of the tentatively identified compound (Figure 1). First, the spectrum was imported into MS as a EF file, and MS predicted fragment formulas using accurate mass information. Then the hemspider database was searched to find all possible structural isomers. a-hydroxyglutaric acid as well as two other structures had the highest compatibility score (9.88). In addition to high compatibility score, a-hydroxyglutaric acid had a higher number of literature references than the other two structures with an equal score. Although this type of confirmation is not completely unambiguous, it provides additional validation for a tentatively identified compound. ounts 1 4 9 8 7 6 5 4 3 1 Figure 11. 73.47 [ 3 H 9 Si 114.71 19.74 [ 6 H 13 OSi 3.95 [ 8 H 19 O Si 47.1183 [ 1 O 3 Si 191.897 6.966 9.141 349.133 [ 13 H 9 O 5 Si 3 6 8 1 1 14 16 18 4 6 8 3 3 34 36 Accurate mass information and MFG were used to identify possible fragment formulas, and thus confirm the identity of the compound accumulated in the morphine-sensitive strain 57BL/6 as a-hydroxyglutaric acid. Figure 1. Structure validation results for the compound tentatively identified as a-hydroxyglutaric acid using Molecular Structure orrelator. Each individual fragment ion is ranked based on mass error corresponding to the proposed formula, along with a penalty based on how many bonds needed to be broken to generate that proposed formula. 9

onclusions Metabolomics studies can benefit from multiple features of the Agilent 7 G/Q-TOF such as accurate mass information, high sensitivity in full spectrum mode, MS/MS capabilities, and the ability to easily switch between EI and I modes. The use of numerous Agilent MassHunter and Agilent Mass Profiler Professional Software capabilities such as deconvolution, statistical analysis, automatic fragment formula annotation, and structure elucidation enabled the identification and confirmation of metabolites whose levels were changing in morphine-sensitive and resistant murine strains. Both G/MS and L/MS approaches have been applied to provide a more complete picture of the metabolome, and the results presented in this application note are consistent with previous L/MS findings []. References 1. J. Folch, M. Lees, G. H. Sloane Stanley, A simple method for the isolation and purification of total lipids from animal tissues, J Biol hem. 6, 497-59 (1957).. D. Liang, G. Liao, J. Wang, J. Usuka, Y. Y. Guo, G. Peltz, J. D. lark A genetic analysis of opioid-induced hyperalgesia in mice, Anesthesiology 14, 154 16 (6a). For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem. www.agilent.com/chem For Research Use Only. Not for use in diagnostic procedures. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 13 Printed in the USA June 5, 13 5991-481EN