Sodium Fluoroacetate by LC-MS/MS

Similar documents
Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

CORESTA Recommended Method No. 86

16 Malachite green 17 Leucomalachite green

Determination of Aminoglycosides in animal tissue by means of LC/MS-MS

Test method for the determination of NDMA and NDEA by LC-MS/MS in Sartan containing film coated tablets

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS

Determination of urea in ultrapure water by IC-MS/MS

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Infant formula and adult nutritionals Determination of vitamin D by liquid chromatographymass spectrometry

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Fumonisin. Fumonisin B 1 Fumonisin B 2. Fumonisin B 3. CAS No.:

The Quantitation and Identification of Coccidiostats in Food by LC-MS/MS using the AB SCIEX 4000 Q TRAP System

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

Validation Report 18

Supporting Information

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Psychoactive Drugs Urine LC-MS/MS Analysis Kit User Manual

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Archived Content. This content was archived on June 24, 2013.

British American Tobacco Group Research & Development. Method - Determination of ammonia in mainstream smoke

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Sulfotepp impurities in Chlorpyrifos EC formulations

The analysis of organic acid content of additives, premix, feed, and water.

VMA, HVA, 5-HIAA Urine LC-MS/MS Analysis Kit User Manual

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

H 3 CO H 3 CO S CH 3

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

British American Tobacco Group Research & Development. Method - Determination of phenols in mainstream cigarette smoke

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

DISCLAIMER: This method:

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

TECHNICAL TEMEPHOS. 1. Specification. Full specification WHO/SIT/19.R4 Revised 10 December Description

CIPAC. CIPAC Free relevant impurities methods:

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

TECHNICAL BRODIFACOUM

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

A Simple SPE Method for the Determination of Malachite Green, Crystal Violet and Other Synthetic Dyes in Seafood

Soils, sludges and treated bio-waste Organic constituents - LAS by HPLC with fluorescence detection (LC-FLD) and mass selective detection (LC- MSD)

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Micro Volume QuEChERS kit

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of trace anions in concentrated hydrofluoric acid

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Method - Determination of aromatic amines in mainstream cigarette smoke

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

Appendix II- Bioanalytical Method Development and Validation

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Chemistry Gas Chromatography: Separation of Volatile Organics

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Analyst Software. Automatic Optimization Tutorial

637. Thiamethoxam. HPLC method

This method describes the identification of the following prohibited colorants in cosmetic products:

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Highly sensitive quantitative estimation of genotoxic impurities from API and drug formulation using LC/MS/MS

11 APPENDICES Appendix A. Analytical Method Dicamba on Filter Paper

Catecholamines Urine LC-MS/MS Analysis Kit User Manual

BIOO FOOD AND FEED SAFETY. Histamine Enzymatic Assay Kit Manual. Catalog #: Reference #:

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection

PYRIPROXYFEN TECHNICAL

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

Tecan AC Extraction Plate

New York State Department of Health - Wadsworth Center Laboratory of Organic Analytical Chemistry NYS ELAP Laboratory ID 10763

Quantitative Analysis and Identification of Migrants in Food Packaging Using LC-MS/MS

Sodium Chloride - Analytical Standard

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Limit-test of NDMA and NDEA in Sartans. by GC-MS (Liquid-direct-injection)

Transcription:

Sodium Fluoroacetate by LC-MS/MS 1 SCOPE OF APPLICATION Description of an in-house method for the quantitative determination of sodium fluoroacetate in liquid and powdered milk- and soy-based infant formulas by liquid chromatography tandem mass spectrometry (LC-MS/MS). The limit of quantification (LOQ) of sodium fluoroacetate is 1 µg/kg by this method. An application of this method to matrices not covered by the scope of application requires an additional validation. 2 DEFINITION AND ABBREVIATIONS 2.1 Definition Sodium fluoroacetate (Figure 1) is a synthetic pesticide known as 1080 and used to fight mammalian pest species. Farmers and graziers use the poison to protect pastures and crops from various herbivorous mammals. It is used as well to protect sheep and goats from predatory coyotes (predacide). In New Zealand and Australia it is employed to control invasive non-native mammals that prey on or compete with native wildlife and vegetation. Sodium fluoroacetate is highly toxic to mammals, including humans. This pesticide is approved for use in the following countries: USA, Canada, Mexico, Australia, New Zealand, Korea, Japan and Israel. New Zealand has used 1080 for pest control since the 1950's, while the United States began use in the 1940's. Sodium fluoroacetate is also a naturally occurring poison found in at least 40 plants native in Australia, South and West Africa and Brazil. F O ONa Figure 1. Chemical structure of sodium fluoroacetate (NaFC 2 H 2 O 2 ; CAS 62-74-8; MW 100 g/mol) 1

2.2 Abbreviations LC-MS/MS ESI SRM IS Liquid Chromatography tandem Mass Spectrometry Electro Spray Ionisation Selected Reaction Monitoring Internal Standard 3 PRINCIPLE OF METHOD Milk powder is first re-constituted in water. Acetonitrile is added to precipitate proteins. After centrifugation, the supernatant is washed with hexane and then acidified with concentrated sulphuric acid. QuEChERS salts (MgSO 4 and NaCl) are added for phase separation and the mixture is centrifuged. The resulting supernatant is evaporated to 0.5 ml remaining volume and centrifuged before LC-MS/MS analysis in selected reaction monitoring (SRM) by electrospray ionisation (ESI) in negative mode. The compound is analysed as its fluoroacetate anion. Quantification is performed by the isotopic dilution approach using 13 C labelled sodium fluoroacetate. Positive identification of fluoroacetate in samples is conducted according to the confirmation criteria defined in EU Commission Decision 2002/657/EC [1]. 4 SAFETY PRECAUTIONS Material Safety Data Sheets (MSDS) should be available for all chemicals, inherent risks and corresponding safety precautions shall be identified. Follow general safety precautions and environmental aspects as described in the local Safety, Health & Environment rules in place. WARNING - Sodium fluoroacetate is highly toxic to humans. Take all necessary precautions especially when working with concentrated stock standard solutions. 5 CHEMICALS AND MATERIALS Commercial references are only a guideline. Use equivalent chemicals or materials when listed items are not locally available. 2

5.1 Chemicals Before using chemicals, refer to the Sigma/Aldrich Guide to Chemical Safety and/or other adequate manuals or safety data sheets approved by your local authorities and ensure that the safety guidelines are applied. CAS number - Chemical or reagent, purity (e.g. supplier, article number and website) 7732-18-5 - Water for chromatography (e.g. Merck LiChrosolv art. 1.15333.1000, www.emdmillipore.com) 75-05-8 - Acetonitrile, hypergrade for LC-MS (e.g. Merck LiChrosolv art. 100029, www.chemdat.info 7487-88-9 QuEChERS extraction packets, 10 g, 200 foil packs per box, each - pack containing 4 g of magnesium sulphate (MgSO 4 ) and 1 g of 7647-14-5 sodium chloride (NaCl) (e.g. Agilent art. 5982-7550, www.agilent.com) 540-69-2 - Ammonium formate, LC-MS ultra, eluent additive for UHPLC-MS (e.g. Fluka art. 14266, www.sigmaaldrich.com ) 7664-93-9 - Sulfuric acid, concentrated, w = 95 97 % (e.g. Merck art. 100731, www.merckmillipore.com ) 64-18-6 - Formic acid, concentrated (e.g. Merck art. 100264, www.chemdat.info) 62-74-8 - Sodium fluoroacetate, w = 99 %, 10 µg/ml in water (e.g. Dr Ehrenstorfer art. DRE-L13772000AL, www.lgcstandards.com) - 13 C 2 -Sodium fluoroacetate, w = 99 %, isotopic purity > 99.5 % (e.g. BDG Synthesis art. 130042-10, http://bdg.co.nz ) 5.2 Materials Falcon tubes, conical, polypropylene, 50-mL (e.g. Becton Dickinson - Labware, art. 352070, www.bdbiosciences.com) Falcon tubes, conical, polypropylene, 15-mL (e.g., Becton Dickinson - Labware, art. 352097, http://www.bdbiosciences.com) Centrifuge with rotors adapted for 50-mL and 15-mL tubes, 4000 x g, - temperature controlled (e.g. Multifuge Heraeus, www.thermo.com ) - Vortex (e.g. Millian Genie 2, http://www.milian.com ) Centrifuge with rotor adapted for 2-mL tubes, 17 000 x g, (e.g. Heraeus - Frisco 17, www.thermoscientific.com ) Microcentrifuge tubes, polypropylene, 2 ml (e.g. Trefflab, art. - 9607246901, www.treff-ag.ch ) - Analytical balance with precision range 0.01 mg - Shaker GenoGrinder, model 2010, www.spexsampleprep.com 5.3 Special equipment and instrumentation Where a specific model is cited, an alternative may be used if it has the same characteristics. HPLC Agilent 1200 SL (www.agilent.com) coupled to a Sciex 5500 triple stage quadrupole mass spectrometer equipped with a TurboIonSpray ionization source (www.absciex.com). 3

5.3.1 HPLC column Acquity UPLC BEH Amide, 2.1 mm x 100 mm, 1.7 µm (Waters art. 186004801, www.waters.com). 5.4 Glassware decontamination No specific requirement. 6 PREPARATION OF REAGENTS Volumes of glassware are purely indicative and may be modified as long as the proportion of reagents is maintained. 6.1 Sodium fluoroacetate stock standard solution, 10 µg/ml in water The stock standard solution is available as ready-to-use 10-mL solution. Store at room temperature for the time given in the certificate of analysis. 6.2 Sodium fluoroacetate working standard solution, 1.0 µg/ml in acetonitrile:water (9 + 1) Into a 10-mL volumetric flask, pipette 1.0 ml of the stock standard solution 10 µg/ml (6.1). Complete to volume with acetonitrile. Store at - 20 C for no longer than 6 months. Allow warming at room temperature before use. 6.3 Sodium fluoroacetate working standard solution, 0.2 µg/ml in acetonitrile Into a 10-mL volumetric flask, pipette 2.0 ml of the stock standard solution 1 µg/ml (6.2). Complete to volume with acetonitrile. Store at - 20 C for no longer than 6 months. Allow warming at room temperature before use. 6.4 Sodium fluoroacetate working standard solution, 0.05 µg/ml in acetonitrile Into a 10-mL volumetric flask, pipette 2.5 ml of the stock standard solution 0.2 µg/ml (6.3). Complete to volume with acetonitrile. Store at - 20 C for no longer than 6 months. Allow warming at room temperature before use. 6.5 13 C 2 -Sodium fluoroacetate (IS) stock standard solution, 1000 µg/ml in water Into a 10-mL volumetric flask, weigh 10 mg ± 0.1 mg of standard. Dissolve and complete to the mark with water. Alternatively (to minimize analyst exposure during weighing) weigh the container containing the analyte first (w 1, in mg), then transfer its whole content into a 10-mL volumetric flask. 4

Dissolve and complete to mark with water for chromatography. Weigh again the empty original container once dried (w 2, in mg). Concentration of this solution in µg/ml is (w 1 - w 2 )/(10 x 1000). Store at - 20 C for no longer than 6 months. Allow warming at room temperature before use. 6.6 13 C 2 -Sodium fluoroacetate (IS) working standard solution, 10 µg/ml in acetonitrile Into a 10-mL volumetric flask, pipette 100 µl of the stock solution 1000 µg/ml (6.5). Complete to volume with acetonitrile. Store at - 20 C for no longer than 6 months. Allow warming at room temperature before use. 6.7 13 C 2 -Sodium fluoroacetate (IS) working standard solution, 0.2 µg/ml in acetonitrile Into a 50-mL volumetric flask, pipette 1000 µl of the working standard solution 10 µg/ml (6.6). Complete to volume with acetonitrile. Store at - 20 C for no longer than 6 months. Allow warming at room temperature before use. 6.8 Standard solutions for calibration curve Into six separate 5-mL volumetric flasks, transfer the volumes of working standard solutions as described in the following table. Complete to the mark with acetonitrile. Store at -20 C for no longer than 6 months. Allow warming at room temperature before use. Working standard solution of sodium fluoroacetate, 0.2 µg/ml (6.3) (µl) Working standard solution of IS, 0.2 µg/ml (6.7) (µl) Acetonitrile STD 1 STD 2 STD 3 STD 4 STD 5 STD 6 0 50 150 300 500 1000 500 500 500 500 500 500 Complete to the 5-mL mark This corresponds to: Concentration of sodium fluoroacetate (ng/ml) 0 2 6 12 20 40 Concentration of IS (ng/ml) 20 20 20 20 20 20 6.9 Solutions for LC-MS/MS 6.9.1 Mobile phase A, water containing 5 mm of ammonium formate and 0.01 % (v/v) formic acid Into a weighing boat, weigh 315 mg ± 5 mg of ammonium formate. Transfer this mass into a 1000-mL volumetric flask. Add ca. 300 ml of water for chromatography and mix to dissolve. Add 100 µl of concentrated formic acid. Complete to volume with water for chromatography. Mix. Store at room temperature for no longer than 1 month. 5

6.9.2 Mobile phase B, acetonitrile Use acetonitrile gradient grade for liquid chromatography. 6.9.3 Solution for flushing injection port, acetonitrile water (1 + 1) Into a 1000-mL volumetric flask, transfer by means of graduated cylinder, 500 ml of acetonitrile gradient grade for chromatography. Complete to volume with water for chromatography. Transfer into a HPLC bottle. Store at room temperature for no longer than 1 month. 7 SAMPLING AND PREPARATION OF TEST SAMPLES 7.1 Sampling procedure A representative sample (min 100 g or 100 ml) should have been sent to the laboratory. It should not have been damaged or changed during transport or storage. 7.2 Laboratory sample Store in the laboratory at room temperature until analysis, unless otherwise mentioned. 7.3 Test sample preparation Powdered sample: Mix well the powdered laboratory sample by means of a spoon before taking a test portion. Alternatively, transfer the whole sample into a container of capacity about twice that of the laboratory sample volume. Close the container immediately. Mix thoroughly by repeatedly shaking and inverting the container. Liquid sample: Shake thoroughly the container containing the sample. 8 PREPARATION OF TEST PORTIONS & EXTRACTION PROCEDURE QC samples (certified, P-test, in-house reference samples or spiked samples) must be regularly included and analysed in duplicate. Different product types should be analysed regularly in duplicate. If necessary, different sized glassware may be substituted for specific volumes listed during the preparation of test solutions as long as the proper dilutions ratios are maintained. 8.1 Test portion preparation 8.1.1 Powdered sample Into a 50-mL polypropylene Falcon tube, weigh 5.0 g ± 0.1 g of powdered sample (7.3). Record the mass to 0.1 g. 6

Add 20 ml of water for chromatography. Mix thoroughly by inversion and place onto a GenoGrinder shaker. Shake for 1.5 min at 1500 rpm. No lump should be visible. Transfer 5.0 g ± 0.1 g of this slurry into a 15-mL polypropylene Falcon tube. Record the mass to 0.1 g. Add 50 µl of the IS working solution 0.2 µg/ml (6.7). Mix thoroughly and make sure that the spiked volume is totally absorbed by the matrix. This spike corresponds to 10 µg/kg equivalent-in-sample concentration of IS. 8.1.2 Liquid sample Into a 15-mL polypropylene Falcon tube, weigh 5.0 g ± 0.1 g of liquid sample (7.3). Add 250 µl of the IS working solution 0.2 µg/ml (6.7). Mix thoroughly and make sure that the spiked volume is totally absorbed by the matrix. This spike corresponds to 10 µg/kg equivalent-in-sample concentration of IS. 8.2 Extraction procedure To the test portion prepared as described in 8.1.1 or 8.1.2, add 8 ml of acetonitrile. Mix thoroughly. Place onto a GenoGrinder shaker and shake for 1.5 min at 1500 rpm. Centrifuge at 4000 g at room temperature for 5 min and transfer the supernatant (ca. 9 ml to 10 ml) into a 50-mL Falcon tube. Add 10 ml of hexane. Place onto a GenoGrinder shaker and shake for 1.5 min at 1500 rpm. Centrifuge at 4000 g at room temperature for 5 min. Pipette the upper hexane phase and discard it to waste. Add 100 µl of concentrated sulphuric acid (H 2 SO 4 ) to the solution containing the analyte. Mix thoroughly. The resulting ph must be 1 to have the analyte in its acidic form (pka of fluoroacetic acid is 2.39). Add a buffer salt mixture (Agilent QuEChERS ready-to-use mix) containing 4.0 g ± 0.4 g of MgSO 4 and 1.0 g ± 0.1 g of NaCl. Immediately hand-shake by inversion or by vortexing to prevent any lump formation. Place onto a GenoGrinder shaker and shake for 1.5 min at 1500 rpm. Centrifuge at 4000 g at room temperature for 5 min and transfer the supernatant (ca. 5 ml) into a 15-mL Falcon tube. Evaporate the collected supernatant under a stream of nitrogen at 40 C ± 2 C until a 0.5 ml remaining volume. A mark at the 0.5 ml level is visible onto the tube. Do not evaporate to lower volumes to prevent loss on evaporation. 7

Transfer the 0.5-mL remaining volume into a 2-mL tube and centrifuge at 17 000 g at room temperature for 5 min. Transfer the clear supernatant into a HPLC vial for further LC-MS/MS analysis. 8.3 Reagent blank In order to control any contamination during the sample workup, a reagent blank must be analysed along with each series of routine samples. Water is used instead of milk. Proceeded exactly as described in 8.1 and 8.2. 9 INSTRUMENTAL CONDITIONS 9.1 LC-MS/MS analysis Where a specific instrument is cited, an alternative may be used provided it has the same or better characteristics. As well, an alternative HPLC column may be used provided it allows a retention time of the first eluting analyte that is at least twice the retention time corresponding to the void volume of the column. 9.1.1 HPLC conditions (using an Agilent 1200SL HPLC system) Mobile phase A Water containing 5 mm of ammonium formate and 0.01 % formic acid (6.9.1) Mobile phase B Acetonitrile (6.9.2) Injection volume 20 µl Column Waters Acquity UPLC BEH Amide, 2.1 mm x 100 mm, 1.7 µm Column oven temp 45 C Flow rate 0.45 ml/min Needle wash In flush port for 20 s using acetonitrile : water (1+1) solution (6.9.3) Diverter valve HPLC flow is directed into the MS detector between 1.0 min and 2.5 min Gradient LC gradient is described in Table 1 Table 1. LC gradient used for the analysis sodium fluoroacetate Time (min) A (%) B (%) 0 10 90 2.0 10 90 3.0 60 40 4.5 60 40 4.6 10 90 8.0 10 90 Using these conditions, the compound elutes at ca. 1.7 min (see Enclosures 1 to 4). 8

9.1.2 MS parameters MS parameters (Tables 2 and 3) are obtained by separately syringe-infusing standard solution (ca. 1 µg/ml) of each unlabelled and labelled compounds (syringe flow rate of 10 µl/min) along with the HPLC flow at 0.45 ml/min using a T connector. The HPLC flow is constituted with 10 % A (6.9.1) and 90 % B (6.9.2). Table 2. Typical MS parameters for the analysis of sodium fluoroacetate Parameter Applied Biosystems Sciex 5500 Ionisation type Electrospray (ESI) Polarity Negative ionisation Spray voltage -4500 V Source block temperature 500 C Curtain Gas: 30 psi Gas Ion Source Gas 1 (GS1): 40 psi Ion Source Gas 2 (GS2): 40 psi Vertical micrometer value: 5.0 Source position adjustments Horizontal micrometer value: 5.0 Electrode protusion: 1.0 mm Collision Energy (CE) -15 Entrance potential (EP) -10 V Collision exit potential (CXP) -9 V Declustering potential (DP) -45 V CAD gas pressure (MRM) Medium (8) Resolution High on each quadrupole Scan time (for each transition) 100 ms Table 3. Transition reactions monitored for the analysis of sodium fluoroacetate (as its fluoroacetate anion) and its corresponding IS and peak area ratios along with their limit of acceptance according to CD 2002/657/EC [1] Transition reactions (m/z) used for Quantification Analyte confirmation Peak area ratio ± limit (%) Fluoroacetate 77.0 33.0 77.0 57.0 0.80 ± 20 13 C 2 - Fluoroacetate (IS) 79.0 34.0 79.0 59.0 0.68 ± 20 Note: m/z 57 corresponds to the loss of hydrofluoric acid [M-HF] - and m/z 33 to the loss of carbone dioxide [M-CO 2 ] -. 9

9.2 Instrument check test Before routine analysis, ensure that your LC-MS/MS apparatus is working in conditions such as the method stays fit for purposes. This involves to inject a low concentration calibrant (e.g. STD2, 6.8) to check that sensitivity of the instrument is adequate. 10 OPERATING PROCEDURE & DETERMINATION 10.1 Sequence set up Inject solutions in the following order: acetonitrile (as blank solvent) at least three times, standard solutions (6.8), acetonitrile at least three times, reagent blank (8.3), extract solutions (8.2) and standard solutions (6.8) again. Inject acetonitrile after each three to four extract solutions to check for any carry-over. 10.2 Calibration Construct a calibration curve by plotting peak area ratio of the analyte and its IS (= y axis) against concentration ratio of the analyte and its IS (= x axis). Calculate the slope and the intercept by linear regression. Check the linearity of the calibration (regression coefficient R 2 should be higher than 0.98 and relative standard deviation of the average of response factors (= y/x) should be < 15 %). 10.3 Identification and confirmation Sodium fluoroacetate is identified and confirmed when the following criteria are fulfilled [1]: a) The ratio of the chromatographic retention time of the analyte to that of its IS, i.e. the relative retention time, corresponds to that of the averaged relative retention time of the calibration solutions within a ± 2.5 % tolerance. b) The peak area ratios from the different transition reactions recorded for the analyte and its IS are within the tolerances fixed by the EU criteria [1] as shown in Table 3. 10.4 Time of analysis Following this procedure, 20 samples can be analysed within 24 h. 11 CALCULATIONS AND EXPRESSION OF RESULTS 11.1 Calculation Calculate the mass fraction, w, of sodium fluoroacetate in microgram per kilogram of sample (µg/kg), using the equation: 10

A a I A is mis w = x S m where A a = peak area of the analyte in the sample (transition reaction used for quantification); A is = peak area of the IS in the sample (transition reaction used for quantification); I = intercept of the regression line for the transition reaction used for quantification; S = slope of the regression line for the transition reaction used for quantification; m is = mass of IS added to the test portion, in ng (i.e. 10 ng for powdered sample and 50 ng for liquid sample); m a = mass of the test portion, in g (i.e. 1 g for powdered sample and 5 g for liquid sample) 11.2 Expression of Results Report the result of sodium fluoroacetate in µg/kg with one significant figure. Non detected amount must be expressed as < 1 µg/kg. a 12 PERFORMANCE CHARACTERISTICS 12.1 Linearity Linearity was verified over the 0 2 area ratio range, corresponding to 0 0.8 ng of sodium fluoroacetate (0.4 ng of IS) injected on-column. The calibration follows a linear model with R 2 > 0.99 and relative standard deviation of the average of response factors < 15 %. 12.2 Limit of quantification (LOQ) LOQ has been estimated by considering a signal-to-noise (S/N) ratio of 10 at the transition reaction used for quantification while having S/N of at least 3 at the transition reaction used for peak confirmation. This LOQ is 1 µg/kg. 12.3 Recovery Recovery data have been obtained by spiking four powdered milk-based infant formulas, two soy-based infant formula and three liquid milk-based infant formula at the 1 µg/kg level in duplicate. Samples were previously known to be free of sodium fluoroacetate. Average recovery data were 113 % ± 5 % (n=9). Chromatograms are shown in Enclosures 1 to 4 13 INTERNAL CONTROL PLAN QC samples (certified, P-test, in-house reference samples or spiked samples) must be regularly included and analysed in duplicate. 11

13.1 Spiked experiment Calculate the recovery rate (Rec) of the spiked sample using the following equation: ρt ρ N Re c = 100 ρ where ρ T is the total concentration of sodium fluoroacetate measured in the spiked sample in micrograms per kg. ρ N is the native concentration of sodium fluoroacetate measured in the non-spiked sample in micrograms per kg. ρ Spiked is the concentration of sodium fluoroacetate spiked in the sample in micrograms per kg (calculated value) The recovery rate should between 90 120% when spiked at the 1 µg/kg level. Spiked 14 LITERATURE [1] Commission Decision 2002/657/EC of 12 August 2002 implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results, Off. J.Eur. Communities 2002, L221, 8-36. http://eur-lex.europa.eu/legal-content/en/txt/pdf/?uri=celex:32002d0657&rid=1 15 ENCLOSURES 1. Enclosure 1 LC-MS/MS chromatograms of a powdered milk-based (lactose free) infant formula unspiked and spiked at the 1 µg/kg (IS 10 µg/kg) level. 2. Enclosure 2 LC-MS/MS chromatograms of a liquid milk-based infant formula (ready-tofeed) unspiked and spiked at the 1 µg/kg (IS 10 µg/kg) level. 3. Enclosure 3 LC-MS/MS chromatograms of a powdered soya-based infant formula unspiked and spiked at the 1 µg/kg (IS 10 µg/kg) level. 4. Enclosure 4 LC-MS/MS chromatograms of a powdered milk infant formula unspiked and spiked at the 1 µg/kg (IS 10 µg/kg) level. 12

77 33 Milk Infant Formula Lactose Free LIMS 890000008555 Unspiked 77 57 79 34 (Internal Std) 79 59 (Internal Std) 77 33 Milk Infant Formula Lactose Free LIMS 890000008555 Spiked at 1 µg/kg 77 57 79 34 (Internal Std) 79 59 (Internal Std) Enclosure 1 LC-MS/MS chromatograms of a powdered milk-based (lactose free) infant formula unspiked and spiked at the 1 µg/kg (IS 10 µg/kg) level 13

77 33 Milk Infant Formula Ready-to-feed (liquid) LIMS 890000008557 Unspiked 77 57 79 34 (Internal Std) 79 59 (Internal Std) 77 33 Milk Infant Formula Ready-to-feed (liquid) LIMS 890000008557 Spiked at 1 µg/kg 77 57 79 34 (Internal Std) 79 59 (Internal Std) Enclosure 2 LC-MS/MS chromatograms of a liquid milk-based infant formula (readyto-feed) unspiked and spiked at the 1 µg/kg (IS 10 µg/kg) level 14

77 33 Infant Formula Soya-based LIMS 890000008560 Unspiked 77 57 79 34 (Internal Std) 79 59 (Internal Std) 77 33 Infant Formula Soya-based LIMS 890000008560 Spiked at 1 µg/kg 77 57 79 34 (Internal Std) 79 59 (Internal Std) Enclosure 3 LC-MS/MS chromatograms of a powdered soya-based infant formula unspiked and spiked at the 1 µg/kg (IS 10 µg/kg) level 15

77 33 Milk Infant Formula LIMS 890000008562 Unspiked 77 57 79 34 (Internal Std) 79 59 (Internal Std) 77 33 Milk Infant Formula LIMS 890000008562 Spiked at 1 µg/kg 77 57 79 34 (Internal Std) 79 59 (Internal Std) Enclosure 4 LC-MS/MS chromatograms of a powdered milk infant formula unspiked and spiked at the 1 µg/kg (IS 10 µg/kg) level 16