KERBER Ion Mobility Spectrometers

Similar documents
KERBER Ion Mobility Spectrometers

Gruznov, Vladimir. Calhoun: The NPS Institutional Archive Monterey, California. Naval Postgraduate School

NEUTROTEST- A NEUTRON BASED NONDESTRUCTIVE DEVICE FOR EXPLOSIVE DETECTION

Ion Mobility Spectrometer (IMS) Standalone IMS with integrated micro-computer and color display

Chemical Radiological & Explosive. Detection Solutions for First Responders

Chemical Radiological & Explosive. Detection Solutions for First Responders

DEVELOPMENT AND OPTIMIZATION OF THE UV REDUCER FOR THE DETERMINATION OF EXPLOSIVES

Ion Mobility Spectrometry for the Detection of Explosives

User Guide & Technical Information

Fundamentals of explosive chemistry. Synopsis:

Third Series: The First Pillar of Petrochemicals: Methane (2 of 10)

Nanofiber Technology for Next Generation Chemical Sensors. Company and Technical Overview Non-NDA Version

Application of Nuclear Quadrupole Resonance to Detection of Explosives and Research Activities at CIAE

During photosynthesis, plants convert carbon dioxide and water into glucose (C 6 H 12 O 6 ) according to the reaction:

Chemistry 104 Final Exam Content Evaluation and Preparation for General Chemistry I Material

Supporting Information. Use of Mass Spectrometric Vapor Analysis to Improve Canine Explosive Detection Efficiency

Explosives: categorization

F321: Atoms, Bonds and Groups Structure & Bonding

Unit 3: Chemical Equilibrium Chemistry Write balanced chemical equations for each of the following. Pay close attention to the physical states!

3 Chemical Equilibrium

Written by: - SHAHZAD IFTIKHAR Contact # Website: s:

CHAPTER 9 CHEMICAL QUANTITIES

Detection and Classification of Explosive Compounds in Presence of Interferents Utilizing Laser Ion Mobility Spectrometry

7.1 Describing Reactions. Burning is a chemical change. When a substance undergoes a chemical change, a chemical reaction is said to take place.

PRACTICE EXAMINATION QUESTIONS FOR 1.2 AMOUNT OF SUBSTANCE

4. Aqueous Solutions. Solution homogeneous mixture of two components

Chapter 9. Table of Contents. Stoichiometry. Section 1 Introduction to Stoichiometry. Section 2 Ideal Stoichiometric Calculations

AP CHEMISTRY 2009 SCORING GUIDELINES

4) Tetrasulfur trioxide. 5) barium fluoride. 6) nitric acid. 7) ammonia

Unit 7: Stoichiometry Homework Packet (85 points)

APLICACIÓN DEL SISTEMA TANDEM DMA-MS AL ANÁLISIS ATMOSFÉRICO

Chlorine and Hydrogen Chloride Monitoring Utilizing Ion Mobility Spectroscopy (IMS)

Based on the kinetic molecular theory of gases, which one of the following statements is INCORRECT?

Identify the reaction type, predict the products, and balance the equations. If it is a special decomposition or synthesis, identify which kind.

Representing Chemical Change

Chemistry 400: General Chemistry Sacramento City College HW#1: Review to Begin Chemistry 400. Review of Chapter 1

CHEM111 UNIT 1 MOLES, FORMULAE AND EQUATIONS QUESTIONS

Salt (sodium chloride) is added to many types of food. Sodium chloride is produced by reacting sodium with chlorine.

Question 8 Chemical properties of metals and nonmetals. 1) magnesium 2) sulfur trioxide 3) iron (II) hydroxide 4) sodium nitrate

Questions Q1. The first ionization energies, in kj mol -1, of four elements with consecutive atomic numbers are shown below. A 1680 B 2080 C 496 D 738

Rapid Field Testing of Ecstasy Pills Using a 1064-nm Handheld Raman Device

Explosive Screening by Vapour Detection: Operational Aspects

EXAM REVIEW. a b c d What would be the mass of mol of sulfuric acid?

Chemical Oxidation Oxidizing agents

HOMEWORK 1C. (d) 2D + E 2F K eq = 1 x 10 9 I C E

Structure and IM Forces Practice Problems

AP Chemistry Unit 2 Test (Chapters 3 and 4)

Stoichiometry of Gases

General Chemistry Multiple Choice Questions Chapter 5

TOPIC: Chemical Bonds

Development of Portable GC/MS System with Benchtop Performance for Critical DoD Applications. Mitch Wells, Ph.D. Philip Tackett, Ph.D.

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

2. 2 Complete this table of the parts of an atom: Particle Charge Location in atom Proton. Negative

26. N 2 + H 2 NH N 2 + O 2 N 2 O 28. CO 2 + H 2 O C 6 H 12 O 6 + O SiCl 4 + H 2 O H 4 SiO 4 + HCl 30. H 3 PO 4 H 4 P 2 O 7 + H 2 O

CHAPTER 3 WATER AND THE FITNESS OF THE ENVIRONMENT. Section B: The Dissociation of Water Molecules

SL Score. HL Score ! /30 ! /48. Practice Exam: Paper 1 Topic 4: Bonding. Name

PRACTICE EXAMINATION QUESTIONS FOR 1.1 ATOMIC STRUCTURE (includes some questions from 1.4 Periodicity)

K P VERSUS K C PROPERTIES OF THE EQUILIBRIUM CONSTANT

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Lab 4 Major Anions In Atmospheric Aerosol Particles

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Chapter 11. Intermolecular Forces, Liquids, and Solids

Name May 2, 2012 Physical Behavior of Matter and Bonding Review

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Exam Style Questions

Chem 127, Final Exam December 14, 2001

Unit Two Worksheet WS DC U2

CHEM111 UNIT 1 MOLES, FORMULAE AND EQUATIONS QUESTIONS

2) How many oxygen atoms are there in 1.55 ng of Ca3(PO4)2? a) 3.01 x b) 1.20 x c) 3.01 x d) 1.21 x e) 2.

Indicators of chemical reactions

Topic 4: Chemical Bonds. IB Chemistry SL Ms. Kiely Coral Gables Senior High

An Introduction to Chemical Reactions, Gases, and Chemical Explosives

Danyal Education (Contact: ) A commitment to teach and nurture

Terahertz absorption spectra of highly energetic chemicals

Elements,Compounds and Mixtures

E-JUST Entrance Exams 2017

General Chemistry. Contents. Chapter 8: The Atmospheric Gases and Hydrogen. Composition of Dry Air. 8-1 The Atmosophere. Chemicals from the Atmosphere

Test Booklet. Subject: SC, Grade: HS CST High School Chemistry Part 2. Student name:

Chemistry. Student Number. Mark / 64. Final Examination Preliminary Course General Instructions. Total Marks 64

Help! I m Melting, wait...i m dissolving! Notes (Ch. 4)

General Chemistry. Chapter 8: The Atmospheric Gases and Hydrogen. Principles and Modern Applications Petrucci Harwood Herring 8 th Edition

Multiple Choice Identify the choice that best completes the statement or answers the question.

Using Fast Neutrons to Detect Explosives and Illicit Materials

UV3000. Accurate, precise, and portable ambient gas point analyzer

1.7 REDOX. Convert these to ionic and half equations and you can see clearly how the electrons are transferred:

g of CO 2 gas is at a temperature of 45 o C and a pressure of 125 kpa. What is the volume of the container? 11 L

Chemical Reactions Unit

1.23 Gas Calculations

ELEMENTS, COMPOUNDS AND MIXTURES AND HOW THEY ARE REPRESENTED. Jan 12-13, 2014

S 8 + F 2 SF 6 4/9/2014. iclicker Participation Question: Balance the following equation by inspection: H + + Cr 2 O 7 + C 2 H 5 OH

Explosives Detection and Identification by PGNAA

SL Chemistry. Friday August 21st Sunday, August 23, 15

Chapter 14. Objectives

November 18, Oct 23 5:37 PM. Oct 23 5:30 PM. Oct 23 5:39 PM. Oct 23 5:38 PM. Oct 23 5:53 PM. Oct 23 5:57 PM

CHEMISTRY HIGHER LEVEL

Name May 2, 2012 Physical Behavior of Matter and Bonding Review

The Copper Cycle. HCl(aq) H + (aq) + Cl (aq) HCl(aq) + H 2 O(l) H 3 O + (aq) + Cl (aq)

Basic SL Concepts. D. 2.0 (Total 1 mark) When the equation above is balanced, what is the coefficient for oxygen? D.

CHEMICAL EQUATIONS WHAT BALANCING AN EQUATION MEANS

Transcription:

KERBER Ion Mobility Spectrometers Modus LLC IMS KERBER is designed to detect trace quantities of low-volatile organic substances, among them are explosives, drugs and toxic substances in the air around controlled objects, on the surface of different objects, on fingers and clothes. The scope of application for the detector: vehicle, cargo and people inspection at customs control; territories and objects inspection by environmental control services; suspects inspection by law-enforcement officials etc. The detector can be used when inspecting territories, premises, mobile objects and cargo during customs and border control, in expertcriminology laboratories of different departments, analytical laboratories of industrial enterprises and scientific-research organizations. The detector is serviced by one person and designed for work both in field environment (directly at the place of control) and under conditions of stationary and mobile specialised laboratories. Main advantages Non-radioactive ionization source Doesn t require high-priced expandable materials Wide range of detected chemical agents including home-made peroxide explosives Open database of substances with possibility of alter extension

Substances detected Full name Marker Chemical formula List of explosives detected by the device 1 Ammonium nitrate NIT NH 4 NO 3 2 Dinitrotoluene DNT C 6 Н 3 CH 3 (NO 2 ) 2 3 Trinitrotoluene TNT C 6 Н 2 CH 3 (NO 2 ) 3 4 Trinitroresorcinol (styphnic acid) TNR C 6 H(NO 2 ) 3 (OH) 2 5 Trinitrophenol (picric acid) TNPH C 6 H 2 (NO 2 ) 3 OH 6 Dinitronaphthalene DNN C 10 H 6 (NO 2 ) 2 7 Dimethyldinitrobutane DMNB СH 3 (NO 2 CCH 3 ) 2 CH 3 8 Ethyleneglycoldinitrate EGDN C 2 Н 4 (ОNO 2 ) 2 9 Nitroglycerine NG CHONO 2 (CH 2 ONO 2 ) 2 10 Pentaerythritol tetranitrate (penthrite) PETN (CH 2 ONO 2 ) 4 C 11 Hexogen (RDX) RDX (CH 2 ) 3 N 3 (NO 2 ) 3 12 Octogen (HMX) HMX (CH 2 ) 4 N 4 (NO 2 ) 4 13 Tetryl TETR (NO 2 ) 3 C 6 H 2 N(NO 2 )CH 3 14 Tetrazole TZ СH 2 N 4 15 Benzofuroxan BF С 6 H 4 O 2 N 2 16 Triacetone triperoxide TATP (C 3 H 6 O 2 ) 3 17 Hexamethylene triperoxide diamine HMTD N(CH 2 OOCH 2 ) 3 N 18 Plastic explosives based on hexogen RDX Prev. (CH 2 ) 3 N 3 (NO 2 ) 3 (hexogen+plasticiser) 19 Plastic explosives based on octogene HMX Prev. (CH 2 ) 4 N 4 (NO 2 ) 4 (octogene+plasticiser) 20 Octol (HMX+TNT) HMX, TNT Mixture 21 Semtex (RDX+PETN+ plasticiser) RDX, PETN Mixture 22 Ammonite, amatol TNT, NIT, (RDX) Mixture List of drugs detected by the device 1 Amphetamine AMP C 9 H 13 N 2 Methamphetamine MET C 10 H 15 N 3 Cocaine COCB, COCS C 17 H 21 NO 4 4 Heroin (diacetylmorphine) HER C 21 H 23 NO 5 5 Tetrahydrocannabinol (psychoactive constituent of the THC C 21 H 30 O 2 cannabis plant) 6 Methylenedioxyamphetamine ( Sassafras ) MDA C 10 H 13 NO 2 7 Methylenedioxymethamphetamine MDMA C 11 H 15 NO 2 ( Ecstasy ) 8 Phenobarbital PHNB C 12 H 12 N 2 O 3 9 Morphine MORP C 17 H 19 NO 3 10 Codeine CODN C 18 H 21 NO 3 List of toxic chemicals detected by the device ( Kerber-T model) 1 Hydrogen sulfide H2S H 2 S 2 Hydrogen chloride HCL HCl 3 Hydrogen fluoride HF HF 4 Sulfur dioxide SO2 SO 2 5 Chlorine CL2 Cl 2 6 Ammonia NH3 NH 3 7 Nitric oxide NO NO 8 Nitrogen dioxide NO2 NO 2

List of chemical warfare agents detected by the device ( Kerber-T model) 1 Sarin GB C 4 H 10 FO 2 P 2 Soman GD C 7 H 16 FO 2 P 3 Mustard gas MG C 4 H 8 Cl 2 S 4 Vx VX C 11 H 26 NO 2 PS 5 Phosgene CG CCl 2 O 6 Hydrocyanic acid HCN HCN Basic features Feature Value Overall dimensions of the detector, mm 110 162 410 Weight, kg 3.7 Measurement range of normalised (reduced) mobility of analyzed ions, сm 2 V -1 s -1 0.5 3.0 Detection range of low-volatile organic substances based on 2,4,6- trinitrotoluene (ТNТ), g, 1.0 10-11 2.0 10-7 Threshold for detecting low-volatile organic substances based on 2,4,6- trinitrotoluene (ТNТ), - particulate matter, g, not less 1.0 10-11 - based on vapours, g/сm 3, not less 1.0 10-14 Time for operating mode start-up, min, not more 15 Measurement time, s, not more 5 Time of changing the type of analyzed ions (negative or positive), min 1 2 Possibility of false response, %, not more 1 Time of continuous autonomy work with regular block of accumulation batteries, hour, not less 4 Time of detector cleaning under regular operating conditions, min, not more 3 Principles of operation IMS KERBER works according to method of ion mobility spectrometry. This method is based upon division of ions in substances according to their mobility during movement in the drift tube in the constant electric field. The detector working in the search mode for target substances continually takes in air surrounding an inspected object with the speed 5-10 сm 3 /s. Taken air containing molecules of target substances gets into ionization source based on an impulse corona discharge where molecules partially ionize. Ionization process passes through several stages. When the device works there appear positive and negative ions of ambient air (reactant ions) in the discharge chamber (ionization source) and their concentration substantially exceed concentration of detected substances. When target substances get into the device reactant ions transfer a charge to their molecules based on mechanism of chemical ionization under atmospheric pressure. Non-ionized molecules of target substances and air are removed from the system and the ions received are held in the ionization chamber with the help of ion gate. After certain periods of time the ion gate opens and ions portion gets into the drift tube with electric field gradient Е (V/cm). Ionized molecules of different substances have various drift velocity v d in the drift tube depending on their charge, mass and size. Ions with small mass come earlier whereas ions with large mass move more slowly and arrive to the

Ion current, ADC units Gas evacuation Pump Drift rings Ions drift direction Amplifier Ionization source (corona discharge) Collector Sampling Ion gate Pump and humidity sensor Drain granules Humidity sensor Screening mesh Drift area cyclic blow-off system Cleared air collector later. Molecular ions of various compounds differ in arrival time to the collector which allows defining their nature. This time is proportional to drift tube length L (cm) and inversely proportional to electric field gradient Е: where К is mobility coefficient in units of сm 2 V -1 s -1. This relation is of a static character, i.e. it is true only for ions swarm and not for individual ions. Ions mobility depends on temperature and pressure. In order to compare values of ions mobility received under different conditions K values are compared as being under normal conditions: Gas circulation direction in cyclic blow-off system where Т temperature (K) and Р pressure (mmhg) of gas atmosphere where ions move. К о is called reduced mobility (or normalized mobility coefficient). Separated ions get onto the ions current collector signals from which they come into special amplifying and processing system. Operation frequency of ions source is 10 Hz, i.e. every second the system generates 10 ranges. The results are constantly averaged out. Outliers caused by random fluctuations of gas current composition and electric disturbances are being eliminated whereby. The results averaged out are additionally smoothed and might 6000 5000 4000 3000 2000 1000 Background signal TNT TNT 0 15000 20000 25000 30000 35000 40000 45000 Drift time, s

be presented in the form of a ions mobility spectrum. There are peaks on the curve of dependence of ions current upon drift time which correspond to ions of various mobility. Detector software allows analyzing the received range as far as peaks are concerned which correspond to target substances taken into database according to mathematical expectation (assembly average) and time dispersion. If a target organic compound is found and its peak prevails set response threshold the detector gives a signal of alarm and the marker (code) of the detected substance. Insertion of the sampling wipe IMS KERBER has a combined sampling apparatus allowing both sampling of air containing vapours and suspended particulate matter and sampling of particles collected on a special sampling wipe. Vapor detection Using of IMS KERBER by customs officers in inspection of unclaimed baggage Testing of IMS KERBER in Federal Drug Control Service of the Russian Federation (using the unit with the external monitor) Modus LLC. Varshavskoye str., 56, 117638 Moscow, Russian Federation +7 (499) 723-11-28, 723-11-49 www.modus-ltd.ru sales@modus-ltd.ru