Skoog Chapter 7 Components of Optical Instruments

Similar documents
Reflection = EM strikes a boundary between two media differing in η and bounces back

Reflection = EM strikes a boundary between two media differing in η and bounces back

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

Spectroscopy Problem Set February 22, 2018

25 Instruments for Optical Spectrometry

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Skoog Chapter 6 Introduction to Spectrometric Methods

R O Y G B V. Spin States. Outer Shell Electrons. Molecular Rotations. Inner Shell Electrons. Molecular Vibrations. Nuclear Transitions

Chapter 15 Molecular Luminescence Spectrometry

Molecular Luminescence Spectroscopy

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Singlet. Fluorescence Spectroscopy * LUMO

Chapter 17: Fundamentals of Spectrophotometry

Chapter 6 Photoluminescence Spectroscopy

1901 Application of Spectrophotometry

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

Spectroscopy: Introduction. Required reading Chapter 18 (pages ) Chapter 20 (pages )

Chapter 17: Fundamentals of Spectrophotometry

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

Analytical Spectroscopy Review

JABLONSKI DIAGRAM INTERACTIONS BETWEEN LIGHT AND MATTER LIGHT AS A WAVE LIGHT AS A PARTICLE 2/1/16. Photoelectric effect Absorp<on Emission ScaDering

Chem 310 rd. 3 Homework Set Answers

Instrumental Analysis: Spectrophotometric Methods

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

LABORATORY OF ELEMENTARY BIOPHYSICS

What is spectroscopy?

Spectroscopy. Page 1 of 8 L.Pillay (2012)

levels. The signal is either absorbance vibrational and rotational energy levels or percent transmittance of the analyte

Introduction ENERGY. Heat Electricity Electromagnetic irradiation (light)

PART VI : MOLECULAR LUMINESCENCE SPECTROSCOPY (Recommendations 1985)

Introduction to Spectroscopic methods

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

Spectrochemical methods

Ultraviolet-Visible and Infrared Spectrophotometry

CHEM Outline (Part 15) - Luminescence 2013

Analytical Chemistry II

C101-E145 TALK LETTER. Vol. 17

9/28/10. Visible and Ultraviolet Molecular Spectroscopy - (S-H-C Chapters 13-14) Valence Electronic Structure. n σ* transitions

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Lecture 3: Light absorbance

PHYSICS nd TERM Outline Notes (continued)

Chem 434 -Instrumental Analysis Hour Exam 1

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

Chem Homework Set Answers

Ultraviolet-Visible Spectroscopy

Ch 313 FINAL EXAM OUTLINE Spring 2010

JABLONSKI DIAGRAM 2/15/16

Classification of spectroscopic methods

LAB #3: FLUROESCENCE SPECTROSCOPY AND ELECTRON TRANSFER (This lab is adapted from the U of MN Phsyical Chemistry lab manual)

Chemistry 2. Molecular Photophysics

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

27-1 (a) Resonance fluorescence is observed when excited atoms emit radiation of the same

Characterisation of vibrational modes of adsorbed species

Advanced Spectroscopy Laboratory

Ultraviolet-Visible and Infrared Spectrophotometry

A Fluorometric Analysis of Quinine in Tonic Water

Overview of Spectroscopy

Section 7. Temperature Measurement

Spectrophotometric Determination of Iron

1 WHAT IS SPECTROSCOPY?

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Chapter 4 Scintillation Detectors

Course: M.Sc (Chemistry) Analytical Chemistry Unit: III

ARC SPECTRUM OF IRON /COPPER / BRASS

Chem 155 Midterm Exam Page 1 of 10 Spring 2010 Terrill

Lab 11: Must what goes in be the same as what comes out? Spectroscopy & Fluorescence in Chlorophyll.

Single Photon detectors

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

SCINTILLATION DETECTORS AND PM TUBES

Chemistry Instrumental Analysis Lecture 15. Chem 4631

Photochemical principles

Molecular Luminescence. Absorption Instrumentation. UV absorption spectrum. lg ε. A = εbc. monochromator. light source. Rotating mirror (beam chopper)

If you like us, please share us on social media. The latest UCD Hyperlibrary newsletter is now complete, check it out.

Lab #12: Determination of a Chemical Equilibrium Constant

Electronic Excitation by UV/Vis Spectroscopy :

Instrumental Chemical Analysis

09/05/40 MOLECULAR ABSORPTION METHODS

Instrumental Chemical Analysis

Wavelength λ Velocity v. Electric Field Strength Amplitude A. Time t or Distance x time for 1 λ to pass fixed point. # of λ passing per s ν= 1 p

Model Answer (Paper code: AR-7112) M. Sc. (Physics) IV Semester Paper I: Laser Physics and Spectroscopy

Spectrophotometry. Dr. Shareef SHAIK ASST. PROFESSOR Pharmacology

CHAPTER 2. Preliminaries A Review of Optical Physics

Fluorescence Polarization Anisotropy FPA

World Journal of Pharmaceutical Research SJIF Impact Factor 8.074

Lecture- 08 Emission and absorption spectra

EMISSION SPECTROSCOPY

24 Introduction to Spectrochemical Methods

Figure 1 Relaxation processes within an excited state or the ground state.

Atomic Absorption Spectroscopy

Chemistry 1215 Experiment #11 Spectrophotometric Analysis of an Unknown Brass Sample

Basics of UV-Visible Spectroscopy *

What the Einstein Relations Tell Us

Diagnósticos em Plasmas

Luminescence. Photoluminescence (PL) is luminescence that results from optically exciting a sample.

Chemistry Instrumental Analysis Lecture 8. Chem 4631

UV-VIS Spectroscopy and Fluorescence Spectroscopy (Part 2 of 2)

Clinical Chemistry (CHE221) Professor Hicks Week 7. Endpoint vs Kinetic Techniques. Instrumentation and Assay techniques

Lecture 0. NC State University

Transcription:

Skoog Chapter 7 Components of Optical Instruments General Design of Optical Instruments Sources of Radiation Wavelength Selectors (Filters, Monochromators, Interferometers) Sample Containers Radiation Transducers (Detectors) Signal Processors and Readouts Fiber Optics

Image Detectors powerful detectors used instead of PMTs to detect a complete spectrum or part of a spectrum Prism monochromator Exit slit PMT Source Image Detector - located at the focal plane (no exit slit)

Common Image Detectors 1) Electron Image Intensifiers 2) Image Dissectors 3) Solid-State Imaging Systems a) Vidicon tubes b) Optical Multichannel Analyzers (OMAs) c) Photo Diode Arrays (PDAs) 4) Charge Coupled Devices (CCDs) These are often used with intensifiers device to increase sensitivity

Photodiodes, Linear Diode Array & Two Dimensional Arrays

Charge Coupled Device (CCD)

Photovoltaic Cell A ammeter hν thin layer of Ag selenium semiconductor iron or copper Light excites electrons in Se at Se-Ag interface into conduction band and to metal conductor current Good only for high light levels Subject to fatigue effects

Another example of a Photovoltaic cell

Photoconductive detector semiconductor used with voltage applied across it Photons electrons promoted to conduction band high conductivity (lower resistance) PbS, PbSe, InSb good for 0.7 to 4.5 µm (near IR) Ge activated with Cu, Au or Zn good from 2 to 15 µm operated at ~5 o K Considerably less sensitive than PMTs Better than thermal detectors in IR

Photographic detection place film at focal plane and expose (integrating detector) Advantages: 1) good resolution 2) fairly sensitive 3) covers entire spectral region Disadvantages: 1) very old technique 2) quantitatively very bad (can use densitometer)

Thermal Detectors for IR in IR region photons have lower energies necessary to resort to thermal detectors radiation absorbed and temperature change is detected Response time is limited by rate of heat transfer slow Sensitivity is also much poorer

Three types of thermal detectors: 1) Thermocouples (most common) junction between dissimilar metals often covered with black substance to increase absorption Voltage difference across junction is a function of temperature Amplify signal and detect Response time ~60 msec (i.e. slow) Sensitivity is greater using a thermopile = a bundle of many thermocouples

2) Bolometer (thermistor) resistance is a function of temperature Different kinds Ni or Pt metal or oxides like NiO, CoO or MnO Many have black coating on side toward source and a heat shield around them Typically connected to a bridge circuit Johnson noise is important Requires stable power supply

3) Golay Pneumatic Detector (best performance characteristics) hν pnuematic chamber detector source window flexible mount & mirror Heat from radiation gas expands mirror position changes amount of light reflected to photodiode changes Best sensitivity Response time ~4 msec heat transfer in gas phase faster than in solid photodiode detector

Schematic diagram of a Double Beam Spectrophotometer

Schematic diagram of a Double Beam Spectrophotometer

Schematic diagram of a Single Beam Spectrophotometer

Spectrophotometric system using a Fiber Optic Probe for UV-vis absorption measurements

Light propagation down a Fiber Optic Cable based on Total Internal Reflectance

Reflection = EM strikes a boundary between two media differing in η and bounces back Incident ray θ 1 θ 2 Reflected ray Medium 1 (air) η = 1.00 Medium 2 (glass) η = 1.50 Specular reflection = situation where angle of incidence (θ i ) equals angle of reflection (θ r )

I r (η 2 - η 1 ) 2 Reflectance = R = ---- = -------------- I i (η 2 + η 1 ) 2 Where I i and I r = incident & reflected intensity For radiation going from air (η = 1.00) to glass (η = 1.50) as shown in previous slide R = 0.04 = 4 % Many surfaces at 4 % each (i.e., many lenses) can cause serious light losses in a spectrometer. This generates stray radiation or stray light.

Reflectance varies with the angle of incidence Percent Reflectance (R) R = 4 % EM going from air (η = 1.00) to glass (η = 1.50) For monochromatic radiation, as incident angle deviates from the normal, the R tends to increase Angle of Incidence (θ i )

EM going from glass (η = 1.50) to air (η = 1.00) Percent Reflectance (R) R = 4 % Critical Angle EM going from a medium of higher η to a medium of lower η, the angle of incidence can only increase to the critical angle before all of the light is completely reflected back Angle of Incidence (θ i )

Critical Angle (Ф C ) Normal to surface At 90 o incidence sin Ф 1 = 1.0 η 1 sin Ф C = ----- η 2 Incident ray is Ф 1 90 o to normal this is called grazing incidence Ф 2 Refracted ray Maximum value of Ф 2 Ф 2 = Ф C Medium 1 (air) Medium 2 (glass) Important for: 1) Refractometers 2) Fiber Optics

Critical Angle (Ф C ) Normal to surface When incidence is at the Critical angle, refraction is at 90 o η 2 sin Ф C = ----- η 1 Refracted ray Ф 2 Medium 2 (air) Ф 1 Incident ray Maximum value of Ф 1 for Refraction Ф 1 = Ф C Medium 1 (glass) Important for: 1) Refractometers 2) Fiber Optics

Critical Angle (Ф C ) Normal to surface At angles greater than the Critical angle, 100 % reflection occurs or Total Internal Reflectance Refracted ray Ф 2 Medium 2 (air) Reflected ray Ф 1 Incident ray Medium 1 (glass) New value of Ф 1 for Reflection Ф 1 > Ф C Important for: 1) Refractometers 2) Fiber Optics

Light propagation down a Fiber Optic Cable based on Total Internal Reflectance

Typical Fiber Optic Construction

Attenuated Total Reflectance (ATR) Cell for IR Spectroscopy

Applying UV-vis Spectrophotometry Qualitative (as discussed) I) The UV-vis absorption spectrum is related to molecular structure, therefore it provides qualitative information as to structure both from ε and λ. In order to take advantage of this it is desirable to have a scanning instrument to measure the entire spectrum (either a double beam, direct reading instrument or a single beam unit with computer interface. By itself an electronic spectrum is not sufficient to identify a compound (while an IR spectrum is)

Quantitative II) The UV-vis region of the spectrum is particularly well suited to quantitative analysis for several reasons (both chemical & spectroscopic reasons): 1) Large values for ε make it possible to measure low concentrations 2) Many compounds (both organic & inorganic) absorb in the UV-vis region, but most common solvents do not. This is a limiting factor in IR.

3) Absorption bands are broad making it easy to achieve conditions where there are no instrumental deviations from Beer s Law 4) Good instrumentation is available, i.e. good sources, detectors & monochromators III) UV-vis can be used for studying chemical processes that involve conversion of a non-absorber to an absorber or vice versa

1) Spectrophotometric Titrations Example where titrant absorbs Sample + Titrant Product absorbs MnO 4 - + Fe 2+ MnO 2 + Fe 3+ A Reaction incomplete at the endpoint Endpoint Volume of Titrant Added

2) Study Equilibria (acid-base, complex formation, redox, etc.) Reactants don t absorb M + nl ML n Fe 3+ + SCN - FeSCN 2+ Products absorb A Essentially all M is reacted to ML and excess L added 1 2 [L]/[M] Hold [M] constant and increase [L]

Can calculate ε ML from A at excess [L] Get n from extrapolated curve Can calculate equilibrium constant (K) from [ML n ] and mass balances K = ----------- [M] [L] n e.g. C M = [M] + [ML n ] Other calculation methods can be used A involving graphical or computer curve fitting procedures, e.g. Job s Mole ratio Method or the Method of Continuous Variation

3) Study Kinetics X + Y Z absorbs A Measure A vs time after mixing time For quantitative applications, we usually want to measure at one particular λ. Must first scan spectrum to determine the most suitable λ for measurements.

Errors in Photometric Analysis 1) Deviations from Beer s Law - either chemical or instrumental can be handled, in general, by preparing a calibration curve Important the calibration curve should include standards both at higher & lower concentrations than the sample 2) Technique errors cells must be carefully cleaned & kept free of scratches, fingerprints, etc. Clean in concentrated HNO 3. Rinse several times with water. Rinse with sample before use.

Round cells, e.g. Spectronic 20 cells should be positioned the same way for each measurement because of imperfections in glass (square cells too) 3) Source drift in single beam instruments. Must: a) Allow source sufficient time to warm up b) Check 0 and 100 % T settings frequently

4) Stray Radiation strikes detector without going through sample I o A true = log ------ I I + o I s where I s A measured = log ----------- I + I s Stray Light Specification important characteristic of monochromators is intensity of stray radiation

Stray Light Specification e.g. Cary 14 I s = < 10-6 I o at all λ s Spectronic 505 I s = < 10-3 I o Stray light more serious at high concentrations (i.e. high A) makes it difficult to measure high A (i.e. A = 3 or 4) Some instruments are capable of measuring large absorbance Spec 505 100 + 0.1 A measured = log ------------- = 1.96 for A true = 2 1 + 0.1 I o 100 = log - -- = log ----- = 2 I 1 I s = 10-3 x 100 = 0.1

5) Reading Error random error involved in reading A value; today with digital readouts this usually involves: 1) Not allowing instrument to stabilize before taking the reading 2) Assuming greater precision (or accuracy) than the instrument is capable of 3) Biasing the result e.g. 0.019 + 0.002 and 0.021 + 0.002 Are these 2 readings different from one another? Answer is NO! What about if s.d. is is 0.001?

Scale Expansion sometimes reading error can be improved upon by expanding scale Normally use a blank solution to set 100% T & set 0% T with shutter closed (i.e. no light) Expand scale by using a standard that has (for example) 50% T & set instrument to 100% T this expands lower end of scale by a factor of 2 & allows readings in the 0% T to 50% T range to be made with greater accuracy & precision

There is a limit to scale expansion imposed by instrument stability, so you can only expand scale to a point, then source and detector noise become limiting factors Can expand both ends of the scale although it is usually preferable to dilute Often reading error is not significant so it doesn t help to expand the scale

Luminescence light emission accompanying a transition from higher to lower energy levels 1) Phosphorescence example of photoluminescence (excited state generated by photons) often exhibited by solids like glow in the dark key chains, television screens (CRTs) & fluorescent lights 2) Fluorescence also photoluminescence which is usually observed in solution like quinine that is added to tonic water many analytical applications

3) Bioluminescence excited state induced biologically (enzymatic process) exhibited by fireflies, some algae & fish 4) Chemiluminescence excited state induced chemically by bond breakage, often oxidation & used for light sticks & some analytical applications 5) Triboluminescence excited state induced mechanically bite down on hard candy, also Curad bandaids 6) Electroluminescence electrical excitation found in some polymers & electric pickle

Photoluminescence is the most useful kind of luminescence for analysis because: 1) Many compounds exhibit this phenomenon 2) The effect can be readily produced 3) Several variables can be used to control the process (e.g. excitation λ, emission λ, pulsing or modulating excitation source, gating or synchronizing detector response) Chemiluminescence can be used for analysis also, but it is harder to control Bioluminescence is chemiluminescence Others are basically useless analytically

1 = absorption, 2 = vibrational relaxation, 3 = fluorescence, 4 & 7 = radiationless deactivation, 5 = intersystem crossing, 6 = phosphorescnce

When absorption of a photon occurs (process #1), several things can happen: Vibrational Relaxation (VR) - is a nonradiative process (#2) by which the upper vibrational levels lose energy & go to the lowest vibrational level in a given electronic energy state (very fast ~ 10-12 s) Internal Conversion (IC) - non-radiative process (#4) where excited state couples to upper vibrational level of lower electronic energy level followed by VR

Because of Vibrational Relaxation (VR) all absorbed photons result in the promoted electron ending up in the lowest vibrational level of the first excited singlet state This level can then do one of three things: 1) Fluoresce make transition to one of the vibrational levels of the ground state giving up energy as a photon (process #3)

2) Radiationless Deactivation (#4) return to ground state giving up energy as heat, by internal conversion or some sort of collisional deactivation 3) Intersystem Crossing (#5) lowest vibrational level of first excited singlet couples to upper vibrational level of triplet state followed by vibrational relaxation Once formed the triplet state can go to ground state radiationlessly or by emitting a photon = phosphorescence (#6)

The transition T 1 S o (G) with emission of a photon is spin forbidden, has a low probability and a slow rate Fluorescence involves a spin allowed transition very probable fast rate & short lifetime (typically 1-20 nsec) Phosphorescence involves spin forbidden transition not so probable slower rate & longer lifetime ( from 10 4 10 sec)

Moderately interesting website showing an animated Jablonski Diagram for absorption, VR, fluorescence, phosphorescence, etc. http://micro.magnet.fsu.edu/primer/java/jablo nski/lightandcolor/

Spectra 1) Excitation Spectrum fluorescence or phosphorescence intensity (at fixed λ) as a function of excitation λ or absorption λ 2) Fluorescence Emission Spectrum - fluorescence emission intensity vs. λ for a fixed excitation λ (= absorption λ, max.) 3) Phosphorescence Emission Spectrum phosphorescence emission intensity vs. λ for a fixed excitation λ (= absorption λ, max.)

Excitation Fluorescence Phosphorescence Phenanthrene Spectra

Fluorescence and Phosphorescence spectra are at longer λ s because the transition from S 1 S o or G is smaller than the absorption from S o (G) to some upper vibrational level of S 1 Degree of structure in fluorescence spectrum is due to the degree of solvation as discussed for absorption The rigidity of the phenanthrene molecule and its inherent lack of interaction with the solvent also plays a role in spectrum

Spectra 4) Excitation Emission Matrix (EEM) or Total Luminescence Spectrum 3D plot of emission for all possible combinations of excitation λ and emission λ Fluorescence Emission Intensity

EEMs represented as contour plots