VASCO Flex TM Remote Particle size Analyzer

Similar documents
nanoparticle size measurements

The solution for all of your

Particle Size Determination with Dynamic Light Scattering DLS

Particle Analysis at the Touch of a Button. Litesizer series

Particle Charge Titration Zeta Potential Size Distribution

What is the value of multi-angle DLS?

Measuring Lysozyme Monomer at 0.1 mg/ml Concentration. Equipment used : Sample Preparation and Measurement :

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

NANO-flex 180 DLS nanoparticle sizing. Laser. Scattered light from particles. Size & concentration vol%

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

SAXSpace. The modular solution for nanostructure analysis. ::: Innovation in Materials Science

LS Spectrometer. The DLS and SLS system for sophisticated research

The Dangers of Dilution When Measuring Water Based Pharmaceutical Suspensions and How Nanoflex Overcomes these Obstacles

HYDROBETA: A NEW INSTRUMENT FOR MEASURING IN-SITU PROFILES OF THE VOLUME SCATTERING FUNCTION FROM 10 TO 170 DEGREES

PLUS. Zeta/Nano Particle Analyzer

Litesizer Sheet 1. [Home]

RHEOLASER LAB MICRORHEOLOGY & END USE PROPERTIES ANALYSIS. MICRORHEOLOGY

Introduction to Dynamic Light Scattering with Applications. Onofrio Annunziata Department of Chemistry Texas Christian University Fort Worth, TX, USA

The Compact Solution for Nanostructure Analysis. SAXSpace

Spectroscopy in Transmission

The ultimate in desktop particle characterization

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight

The Compact Laboratory SAXS/WAXS/GISAXS System. SAXSpoint

DOE SBIR & STTR FY 2019 Phase 1, Release 1 Topics

NanoParticle Tracking Analysis The NANOSIGHT system.

Quantum Northwest, Inc. Product overview

Robust and Miniaturized Interferometric Distance Sensor for In-Situ Turning Process Monitoring

A New Hyperspectral Spherical-Cavity Absorption Meter

Amended Specifications as per the Pre Bid meeting held on in Chapter 4

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

The ultimate in desktop particle characterization

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Photoluminescence Spectrometer (FLS980)

Intelligent Sensor Management for Brewing Processes

Design Considerations for a Variable Angle Absolute Reflectance Accessory For the LAMBDA 950/850/650 UV/Vis/NIR and UV/Vis Spectrophotometers

Reliability issues of photonic components for space applications

Monitoring Emulsion Polymerization by Raman Spectroscopy

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

HOW ADVANCED PYROMETERS INCREASE THERMAL PROCESS REPEATABILITY AND PRODUCT QUALITY

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Perseverance. Experimentation. Knowledge.

Development of an optical multi-purpose sensor using filtered scattered light

Methods for charge and size characterization colloidal systems

Instrumentation and Operation

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy

STABILITY OF PIGMENT INKJET INKS

LIBSlab ANALYZERS ANALYZERS

SENSORS FOR MEASURING THE VOLUME SCATTERING FUNCTION OF OCEANIC WATERS

How DLS Works: Interference of Light

Particle Analysis at the Touch of a Button. Litesizer series

Particle Size and Rapid Stability Analyses of Concentrated Dispersions

Advanced techniques Local probes, SNOM

and Environmental Science Centre

Scanning Probe Microscopy. Amanda MacMillan, Emmy Gebremichael, & John Shamblin Chem 243: Instrumental Analysis Dr. Robert Corn March 10, 2010

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

SPECTROPHOTOMETERS. Visible and UV-Visible

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

WHITE PAPER ON QUANTUM COMPUTING AND QUANTUM COMMUNICATION

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

UV-vis Analysis of the Effect of Sodium Citrate on the Size and the Surface Plasmon Resonance of Au NPs. Eman Mousa Alhajji

PARTICLE SIZE ANALYTICAL RANGES AND APPLICABILITY. m mm (10-6 m) nm (10-9 m)

Ultra-narrow-band tunable laserline notch filter

New advances in folded pathlength technology for Process Tunable Diode Laser Absorption Spectrometers (TDLAS)

PERSPECTIVE STABLE ISOTOPE RATIO MS

6. Laser Doppler Anemometry. Introduction to principles and applications

Improving nano-scale imaging of of intergrated micro-raman/afm systems using negativestiffness

Applied Physics Department HUJI Applied Physics Department

Session #1: Theoretical background and computer simulations of molecular vibrations.

Double-Slit Interference

Monitoring the Aggregation of Particles through Raman Spectroscopy

Wolter Imaging On Z. Chris Bourdon, Manager Z Imaging and Spectroscopy Julia Vogel, LLNL; Ming Wu, SNL ICF Diagnostics Workshop, October 5 th 2015

Jan. 5, 2006 Development of a Helical Undulator for ILC Positron Source

Agilent Cary 630 FTIR Spectrometer Supporting Organic Synthesis in Academic Teaching Labs

Non contact measurement of viscoelastic properties of biopolymers

Lab #13: Polarization

South pacific Journal of Technology and Science

University of Minnesota Nano Center Standard Operating Procedure

Introduction to Nanoparticle Tracking Analysis (NTA) Measurement Principle of ZetaView

Technology Developments for ESO at the IAC

Miniature Illuminator for Laser Doppler Velocimeter Assembled on Micromachined Silicon optical bench.

PERSPECTIVE STABLE ISOTOPE RATIO MS

Regular Reflectance and Transmittance Measurements of Transmissive Materials Using a STAR GEM Optical Accessory

Extrel is widely respected for the quality of mass spectrometer systems that are

FSA TM Multi-bit Digital Processors

The investigation of the photokinetics of a platinum organoamine complex using the Cary 50/60

FRITSCH NANO PARTICLE SIZER IDEAL FOR PIGMENTS CHEMICALS PETROCHEMISTRY FOODSTUFFS PHARMACEUTICALS ENVIRONMENT COSMETICS DYNAMIC LIGHT SCATTERING DLS

User Fees for the 4D LABS Characterization Facility

Number Density Measurement of Neutral Particles in a Miniature Microwave Discharge Ion Thruster

The new 11-R (one part of the Mini WRAS) and GRIMM MINI-WRAS Andreas Jaksch. Symposium Stockholm Mai

Fadei Komarov Alexander Kamyshan

Survey Meter OD-01 Address: Phone: Fax: URL:

473-SHX Dew Point Mirror

Improving Micro-Raman/AFM Systems Imaging Using Negative-Stiffness Vibration Isolation

Seeing the Nano-scale: Nanoparticle Tracking Analysis HVM MNT Expo 2006 Oxford. Jeremy Warren CEO, NanoSight Ltd

Ms. Monika Srivastava Doctoral Scholar, AMR Group of Dr. Anurag Srivastava ABV-IIITM, Gwalior

Parametric down-conversion

ActiPix SDI300 Surface Dissolution Imaging System

Portable Instrument for Online Investigations of Optical Properties of Airborne Particles

The Laboratory SAXS/WAXS/GISAXS Beamline. SAXSpoint 2.0

Transcription:

Technical note NT01-VASCO Flex_EN_V01 VASCO Flex TM Remote Particle size Analyzer Nano-particle Size measurements brought into your process! 1

VASCO Flex TM Analyzer: «in situ» Nano Particle size measurement for process monitoring! Key Words: Dynamic Light Scattering (DLS), Nano-Particle sizer, fiber remote probe, In situ measurements, process monitoring, glass capillary. Abstract This note presents our unique fiber remote DLS probe for in situ nano particle size measurements named VASCO Flex TM. Developed by CORDOUAN Technologies, VASCO Flex TM is a fully versatile particle size analyzer that makes use of advanced single mode optical fiber to bring DLS measurement to your process. Thanks to its innovative optical fiber remote head which principle is described hereafter, we show how VASCO Flex can be implemented very simply to existing experimental setups like synthesis reactors, or SAXS systems, giving users maximum measurement agility to monitor and improve its process. Introduction Since few years now the use of nano particles in the industry is expanding rapidly because of the unique properties brought by nano materials into final products. Thus, as nano-material science progresses, the fields of application are getting broader, ranging from health and medicine, energy, food & agronomy, environment, electronics, advanced material science, aeronautics, cars, paints/ inks, and it is just the beginning of a new era! Among the important properties of nano-particles, size is probably the most critical one because it is intimately related to their physical and chemical properties like specific area/porosity, bio-availability, stability, ability to be Chemical Synthesis reactor functionalized, etc. So, as the number of installations of nano-particle reactors deployed in the field, either in advanced research labs or in fabrication factories, keeps growing fast, the need for reliable and accurate size monitoring tools is getting crucial. In this context and anticipating that demand from the market, CORDOUAN technologies has developed its unique VASCO Flex system. DLS Measurement principle Today, many recognized methods exist to measure the size and size distribution of nano-particles [1]. Among these methods, Dynamic Light Scattering (DLS) also known as Photon Correlation Spectroscopy (PCS) is certainly one of the prevalent technique of choice in colloidal sciences. Indeed, DLS is a mature and very powerful technique based on the analysis of scattered light fluctuations caused by the Brownian motion of particles [2, 3]; its principle consists in analyzing the fluctuation of a coherent laser light scattered by particles suspended in a liquid as a function of time and at a given angle. It provides accurate particle size measurements from the nanometer up to a few microns in a minute. Today, different measurement configurations are proposed in commercial DLS set up; in the most common ones, the sample is placed in a rectangular disposal glass or quartz cuvette and the scattered light is usually detected at 90 from incident light direction (see figure 1). In some more recent DLS systems like the VASCO sizer from CORDOUAN Technologies, the measurement cell is integrated directly into the instrument and the light is detected backward direction (135 ). In all case, such configuration requires batch sampling; this is acceptable in many laboratory applications, but it is not adapted for in situ and real time process monitoring (time consuming operation, sample stability issues, reproducibility issue, etc). This implies a change of paradigm: if you cannot bring your sample to the measurement, you have to bring the measurement to your process; this is basically the philosophy of the VASCO flex. Figure 1: classical DLS measurement configuration 2

The VASCO flex innovative approach VASCO Flex TM is a unique and fully agile nano-particle size analyzer based on DLS measurement. At the heart of the VASCO Flex system is the Optical Fiber Remote Head (OFRH). The OFRH integrates into the same case housing both the sample illumination optical system and the scattered light collector. The illumination and the collector systems are made of two optimized optical collimators, one used as condenser and the other as a focuser (see figure 2) The OFRH is linked to a central unit with an optical fiber patch cord which integrates two single mode fibers: one Polarization Maintaining fiber used for the laser beam and one standard single mode fiber used to collect the scattered light from the sample to be characterized. The central unit includes a single photon detector (APD or PM), a powerful data processing linear correlator, an external temperature sensor that can be attached to the OFRH, and a highly reliable fiber pigtailed laser diode source with its electrical driver. A PWM temperature controller for Pelletier elements can also be integrated into the central unit for an accurate sample temperature control. Figure 2: the VASCO Flex and its Optical Fibre Remote Head The central unit also integrates an alignment laser diode and an optical switch which allows to couple the alignment laser automatically into the signal fiber in order to image the coherence area into the sample cell or reactor and to facilitate installation (see insert of fig 2). Advantages and Benefits of VASCO Flex Compact and robust: The VASCO Flex has been designed to be easily integrated into various environments, accounting for user s constraints. Using optical fibers and telecom based technologies, VASCO Flex is a cost effective, robust and compact solution for process monitoring (maintenance free); The use of single mode optical fiber naturally acts as a spatial filter that saves space and cost of additional parts like those needed in conventional DLS system. Also light propagation in an optical fiber is much more robust and immune to stray light and external perturbation than free space optical layout Agility : Its working distance (distance between the OFRH and the measurement area) can be easily tuned from 4 cm up to 40 cm, allowing non contact and in situ measurements, ie, without tedious batch sampling (time and cost saving). Also, the fiber patch cord length can be specified to any length between 1 to 20 m; this is a real advantage for remote operation in difficult environments: the Optical remote head can easily be placed in a vacuum chamber or inside a glove box. Easy to implement: With its alignment laser, the OFRH can be implemented and adjusted very easily, even for a non experienced user. OFRH can also be mounted on XYZ translation stages for fine positioning of the probe. Versatility: thanks to its design the VASCO flex can accommodate various measurement configurations: in situ measurement inside a reactor through a glass window, in a standard disposable square cuvette, in cylindrical glass capillaries with diameter as low as 1 mm, in a sample drop, etc. Highly reliable Data analysis: the VASCO flex system is powered by the NanoQ 2.0 software with its unique Pade Laplace inversion algorithm; combined with multiple acquisition capability and measurement replay, this makes VASCO flex an ideal tool for size kinetics monitoring. 3

Examples of VASCO Flex integration Below are two examples of VASCO flex integration into existing setup: The first one is the coupling of DLS measurement to a commercial SAXS bench. This system allows simultaneous DLS +SAXS measurement of a sample into the same glass capillary; Such coupling could be very interesting in application like the one described in ref [4] and [5] where simultaneous measurement by complementary techniques allows a better understanding of the nano-particles behavior and structure. Figure 3: the VASCO Flex and its Optical Fibre Remote Head coupled to a commercial SAXS measurement bench The second example is the integration of the VASCO Flex to a high pressure (80 bars) chemical reactor system used for the synthesis of polymer nano-particle under supercritical CO 2. The setup is presented in figure 4. In this configuration the reactor has two transparent side walls made of 2 cm thick glass windows. The laser beam is focused in the center of the reactor through the front glass window. The backscattered light is detected through the same window. In the setup, the distance between the reactor and the OFRH is about 15 cm. Figure 4: the VASCO Flex and its Optical Fibre Remote Head coupled to a nano-particle polymerization reactor; Figure 5: Set up validation for in situ measurement with a 100 nm calibrated latex standard 4

CONCLUSION Developed by CORDOUAN Technologies, VASCO Flex TM is a unique fully versatile particle size analyzer that makes full use of advanced single mode optical fiber to bring DLS measurement to your process. Thanks to its innovative optical fiber remote head VASCO Flex can be implemented very simply to existing experimental setups like synthesis reactors, or SAXS systems, giving users maximum measurement agility to monitor and improve its process. References: [1] Reliang XU, Particle Characterization: Light Scattering Methods: Kluwer Academic Publishers 2002 (ISBN: 0-792-36300-0) [2] Berne, B.J.; Pecora, R. Dynamic Light Scattering: Willey, New York, 2 nd edition- 2000 (ISBN 0-486-41155-9) [3] B. Chu: Laser Light Scattering Academic Press, New York, 1991 2nd ed. [4] lle Eyssautier, Didier Frot, and Loïc Barre, Structure and Dynamic Properties of Colloidal Asphaltene Aggregates, Langmuir 2012, vol. 28, n o 33, pp. 11997-12004 [5] Soheil Sharifi, Masoud Amirkhani, Jahanbakhsh Mashayekhi Asla, Mohammad Reza Mohammadi, Othmar Marti, Light Scattering and SAXS Study of AOT Microemulsion at Low Size Droplet; Soft Nanoscience Letters, 2012, 2, 8-12 Acknowledgments : The VASCVO flex system has been developed within the course of the SNOW FP7 collaborative project funded by the European Commission. 5