Statistics of Radioactive Decay

Similar documents
Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

Absorption and Backscattering ofβrays

Absorption and Backscattering of β-rays

Lab NUC. Determination of Half-Life with a Geiger-Müller Counter

Physics 1000 Half Life Lab

THE GEIGER-MULLER TUBE AND THE STATISTICS OF RADIOACTIVITY

Radioactivity APPARATUS INTRODUCTION PROCEDURE

LAB 2 1. Measurement of 2. Binomial Distribution

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

FYSP106/K3 GEIGER & MÜLLER TUBE. 1 Introduction. 2 The equipment

Lab 14. RADIOACTIVITY

PHYS 3650L - Modern Physics Laboratory

Radioactivity. PC1144 Physics IV. 1 Objectives. 2 Equipment List. 3 Theory

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

EXPERIMENT 11: NUCLEAR RADIATION

STATISTICAL HANDLING OF RADIOACTIVITY MEASUREMENTS

GAMMA RAY SPECTROSCOPY

Radioactivity INTRODUCTION. Natural Radiation in the Background. Radioactive Decay

RADIOACTIVITY MATERIALS: PURPOSE: LEARNING OBJECTIVES: DISCUSSION:

EXPERIMENT FOUR - RADIOACTIVITY This experiment has been largely adapted from an experiment from the United States Naval Academy, Annapolis MD

Experiment #4: Radiation Counting Statistics

Nuclear Physics and Astrophysics

EXPERIMENT: REACTION TIME

electrons out of, or ionize, material in their paths as they pass. Such radiation is known as

Physics 248, Spring 2009 Lab 6: Radiation and its Interaction with Matter

Chapter 16: Ionizing Radiation

Lab 12. Radioactivity

EEE4106Z Radiation Interactions & Detection

EXPERIMENT 2 Reaction Time Objectives Theory

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

6. Atomic and Nuclear Physics

PHYSICS 176 UNIVERSITY PHYSICS LAB II. Experiment 13. Radioactivity, Radiation and Isotopes

INSTRUCTOR RESOURCES

11 Gamma Ray Energy and Absorption

MASS ATTENUATION COEFFICIENT OF LEAD

NUCLEAR SPECTROMETRY

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Radioactivity. Lecture 6 Detectors and Instrumentation

E. K. A. ADVANCED PHYSICS LABORATORY STATISTICS OF COUNTING WITH A GEIGER COUNTER ARTIFICIAL RADIOACTIVITY

Radiation Detection and Measurement

Overview: In this experiment we will study the decay of a radioactive nucleus, Cesium. Figure 1: The Decay Modes of Cesium 137

Experiment: Nuclear Chemistry 1

Ionization Detectors. Mostly Gaseous Detectors

CHAPTER 1 RADIATION AND RADIOACTIVITY

BETA-RAY SPECTROMETER

THE COMPTON EFFECT Last Revised: January 5, 2007

Shielding Alpha, Beta, and Gamma Radiation 11/08 Integrated Science 3

PHYS 391 Lab 2b: Counting Statistics

Radiation and Radioactivity. PHYS 0219 Radiation and Radioactivity

What is Radiation? Historical Background

Introduction. Principle of Operation

2) Estimate your annual radiation dose from background radiation.

Radioactivity. Introduction

L 36 Modern Physics [3] The atom and the nucleus. Structure of the nucleus. The structure of the nucleus SYMBOL FOR A NUCLEUS FOR A CHEMICAL X

Science of Nuclear Energy and Radiation a Comprehensive Course for Science Teachers June 22-25, 1998 McMaster University

5 Atomic Physics. 1 of the isotope remains. 1 minute, 4. Atomic Physics. 1. Radioactivity 2. The nuclear atom

Experiment 2. Reaction Time. Make a series of measurements of your reaction time. Use statistics to analyze your reaction time.

Princeton University, Physics 311/312 Beta Decay, Page 1 BETA DECAY

L 37 Modern Physics [3] The atom and the nucleus. Structure of the nucleus. Terminology of nuclear physics SYMBOL FOR A NUCLEUS FOR A CHEMICAL X

PLK VICWOOD K.T. CHONG SIXTH FORM COLLEGE Form Seven AL Physics Radioactivity

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

L-35 Modern Physics-3 Nuclear Physics 29:006 FINAL EXAM. Structure of the nucleus. The atom and the nucleus. Nuclear Terminology

Protean Instrument Dutchtown Road, Knoxville, TN TEL/FAX:

PHY 192 Compton Effect Spring

Radionuclide Imaging MII Detection of Nuclear Emission

Millikan Oil Drop Experiment

RADIOACTIVITY Q32 P1 A radioactive carbon 14 decay to Nitrogen by beta emission as below 14 x 0

LAB 13 - RADIOACTIVITY, BETA, AND GAMMA RAYS

Overview: In this experiment we study the decay of a radioactive nucleus, Cesium 137. Figure 1: The Decay Modes of Cesium 137

Chemical Engineering 412

PHYS 3446 Lecture #12

Some hints for the Radioactive Decay lab

Experiment 2 Random Error and Basic Statistics

Name Date Class NUCLEAR RADIATION. alpha particle beta particle gamma ray

Chapter Seven (Nuclear Detectors)

Determining the Efficiency of a Geiger Müller Tube

dn(t) dt where λ is the constant decay probability per unit time. The solution is N(t) = N 0 exp( λt)

Absorption of Gamma Rays

Figure 1. Time in days. Use information from Figure 1 to calculate the half-life of the radioactive isotope.

RADIOACTIVE DECAY - MEASUREMENT OF HALF-LIFE

Modern Physics Laboratory (Physics 6180/7180)

Experiment 6 1. The Compton Effect Physics 2150 Experiment No. 6 University of Colorado

Radioactivity: Experimental Uncertainty

Ph 3504 Radioactive Decay

Experiment 2 Random Error and Basic Statistics

Signals in Particle Detectors (1/2?)

Physics Experimental Physics Temple University, Spring C. J. Martoff, Instructor

RADIOACTIVITY, BETA, AND GAMMA RAYS

Gamma Spectroscopy. References: Objectives:

EXPERIMENT 2-6. e/m OF THE ELECTRON GENERAL DISCUSSION

ABSORPTION OF BETA AND GAMMA RADIATION

SCINTILLATION DETECTORS AND PM TUBES

EQUIPMENT Beta spectrometer, vacuum pump, Cs-137 source, Geiger-Muller (G-M) tube, scalar

General Overview of Gas Filled Detectors

University of Michigan Physics : Advanced Laboratory Notes on RADIOACTIVITY January 2007

Scintillation Detector

Read Hewitt Chapter 33

COUNTING ERRORS AND STATISTICS RCT STUDY GUIDE Identify the five general types of radiation measurement errors.

Physics 23 Fall 1989 Lab 5 - The Interaction of Gamma Rays with Matter

Figure 1. Decay Scheme for 60Co

Transcription:

Statistics of Radioactive Decay Introduction The purpose of this experiment is to analyze a set of data that contains natural variability from sample to sample, but for which the probability distribution function (i.e. the Poisson Distribution) is well known. You will compare your measurements to theoretically derived functions, and test the compatibility of your measurements and the theory. The data are obtained by measuring the decay of a radioactive source using a Geiger counter. Goals: gain familiarity with the specific form and use of the Poisson distribution gain experience with the use of a Geiger counter for measuring radioactive decay events Theory The disintegrations from a radioactive substance occur at random. If the number of counts is measured for a pre-specified time interval, and then the measurement is repeated over the same time interval, it is likely that that number will be different every time you perform a new measurement. It can be shown that in such cases of random decay the frequency distribution Pn () describing the probability of observing n disintegrations in some time interval t is given by the Poisson distribution. This has been discussed in your lectures. The Poisson distribution is given by Pn ()= μn e μ n! where μ is the mean of the distribution. The standard deviation σ of this distribution is given by: σ = μ For large values of μ, the Poisson distribution approaches a Gaussian (normal) distribution: 1 P()= n ( 2πμ e n μ) 2 2μ The Poisson Distribution discussion In previous experiments, we discussed random experimental errors which resulted from limitations of the experiment itself due to imperfections of apparatus or technique. There is another class of error which is due to the random nature of the process being studied, and this second category is the subject of our current experiment. This is often associated with

counting experiments (an important category in modern day physics) and follows the rules of Poisson Statistics. Consider an experiment to measure radioactive decay. One could count the number of decays in a series of (say) 10-s intervals. Since radioactive decays are random in time, the number of decays will not be repeatable between successive measurements. There will be a mean value, but rarely will any measurement actually produce this value. For example, suppose the true mean was 9 counts. Then due to the intrinsic natural variability, it may be possible to measure as low as only 1 or 2 counts, or perhaps as high as 20 counts, using the same experimental setup, because of the random nature of the process. The Poisson distribution gives you the probability Pn ( ) that you will obtain n counts when the mean count over many measurements is μ. Notice that n is an integer in this distribution (i.e. you either count something or you don t). Also, this distribution is very non-symmetric (skewed) when μ is small. This is very different to the distributions that you have normally met so far, for which you assumed you could have a + or error with equal probability. Part of the reason that the distribution is skewed is that you can t have a negative number of counts. However, when μ is large (say > 30) the Poisson distribution approaches a Gaussian distribution with a mean μ and a standard deviation μ. If you are doing a counting experiment in the laboratory (e.g. scattering, γ -ray spectroscopy, or α-particle absorption), you can say that the best estimate of the mean number of counts is the measured mean value n, and the best estimate of the standard deviation about this mean is n. The point here is that you can never know the true mean μ because that would require an infinite number of measurements. The Geiger-Muller (GM) Counter The GM counter is a combination of two devices: - a GM tube for the detection of radioactivity - an instrument that amplifies and counts the electrical signals received from the GM tube The tube has a very thin glass window facing the radioactive source. This permits the electrons emitted from the source to pass into the interior with minor absorption and scattering. The GM tube consists of an outer cylindrical conductor and a central wire maintained at a positive potential with respect to the outer cylinder. As an energetic particle crosses the detector it will ionize a gas molecule in the chamber. The resulting electron and ion are accelerated by the potential, each towards the electrode with opposite sign. For large enough potential difference the electron released in the ionization process will ionize another 2

molecule and this will result in an avalanche of charges that could be detected as an electrical signal. The range of voltages applied to the GM tube that will generate a signal for an incoming ionizing particle is called the Geiger-Muller region. In other words the sensitivity of the amplifier connected to the tube is such that counts are only detected when the tube is operating in the Geiger-Muller region. Different tubes have different characteristics. In our experiment we will use a tube with a range of 300-1000V. The radioactive source used in this experiment is Thallium 204, a radioactive isotope with a half-life of 3.8 years. When it disintegrates, an electron with energy of 0.77 MeV is emitted. It thus has sufficient energy to penetrate the tube and produce a count. Experiment: Apparatus: Geiger-Muller tube, stand and shelf High voltage source and counter Tl 204 source timer Procedure Part I Among your equipment you will find two semicircular pieces of plastic. One is unmarked; this is the non- radioactive blank. The other is the radioactive source. Record the number and letter on the source in your lab book. Check that the high voltage controls are set at minimum values, and switch the power on. The test switch should be off, and the count switch should be on. Switch on the preset timer, and set it to 10 seconds. Put the source and the blank together on the tray and put it on shelf number 4. Increase the voltage to 500 V. Start the timer and record the number of counts in 10 seconds. If necessary move the source to another shelf and repeat until the number of counts is between 800 and 4000. If you still cannot achieve a value of at least 800, record for a little longer, e.g. 15 or 20 or even 30 seconds. Measure the number of counts in your chosen time interval. Repeat 45 times. 3

Part 2 Set the source far from the detector so that the number of counts obtained in 10 seconds is small. This will represent your background level, and is due to natural radioactivity around you in the walls, due to cosmic ray particles etc. Typically you should get values of the order of 1, 2, 3, 4, with less frequent occurrences of numbers like 5, 6, 7 etc. If you find you are getting lots of 5 s and 6 s, say, reduce the recording time to say 5 seconds. If you are getting mainly 0 s and 1 s, increase your recording time. Measure the number of counts in your selected recording period. Repeat 45 times. Note that the recording interval you choose does not have to be the same as in Part I. Analysis Analyze the background counts first, then the source results, as follows. a) Background counts. 1) Plot the data in a histogram format (i.e. abscissa = number of counts, ordinate = number of measurements yielding that number of counts). Use a bin size of one count. You are encouraged to do this with a spread-sheet (like Excel) if possible. 2) Determine the mean, n, and then plot the expected Poisson distribution for this mean value over top of your own data. Ensure that the area under your experimental curve and your theoretical curve are the same (remember that the formula given earlier for the Poisson distribution was normalized to unit area). Also check the standard deviation, and check if it is similar to n. (Note: this might be a good chance for you to learn how to use the standard deviation option on your calculator, or you might use the same function in your spread-sheet package. (It is STDEV in Excel) 3) You will have recorded 45 successive counts e.g. 2, 3, 2, 1, 4, 3,.. etc. Sum the points in groups of 3. In the above example, your first point will be 2+3+2 = 7, and the next point will be 1+4+3 = 8, etc. This will simulate using a longer averaging interval e.g. if you used 10 second intervals, summing 3 successive values will give you an equivalent rate for a 30-second interval. You will now only have 15 points. Calculate your new mean and standard deviation. Check again whether the standard deviation is similar to n (rigorous comparison is not necessary a qualitative comparison will do for now). Plot the expected Poisson distribution, using your new mean. Comment on the symmetry of your graph relative to the first one. Also plot the theoretical distribution assuming it is a Gaussian. 4

b) Radioactive Source counts. The case where you deal with the radioactive source can be considered as an extension of the background case to the situation of much higher count rates. What do you expect the distribution to start to look like at high count rates? 1. Plot the data in a histogram format (i.e. abscissa = number of counts, ordinate = number of measurements yielding that number of counts). Note that this time you will need to experiment with the best choice of bin-size. Describe why you use the choice of bin-size that you do. (Again, you might also find it useful to use a spreadsheet). 2. Determine the mean, and the standard deviation, and check that the relation σ = n still seems valid. Then plot the expected theoretical distribution (for this mean value and standard deviation) over top of your own data. (Should this be a Poisson distribution, or a Gaussian, or are they equivalent? Discuss). Ensure that the area under your experimental curve and your theoretical curve are the same. 3. From your histogram, estimate the probability of getting a single number of counts n which lies between n and n + 50. Now repeat the same determination, but this time using your theoretical fitted curve. In this case you may assume that your standard deviation squared is an exact estimate of the true variance, so you may treat your distribution as a normal distribution with known variance. Remember you are looking at the likelihood of obtaining a single value in this range. Will you use the standard deviation σ, orσ 45, in your calculations? You may use your normal-distribution table in your lecture notes if you like. 4. Divide the data into three groups (a,b,c) of 15 measurements, and find the mean and its standard deviation for the three sets. For example, for set a 15 15 n a = n i i=1 15 andσ na = ( n i n a ) 2 ( 15 1)15 (). i=1 Test the hypothesis that these 3 data sets are statistically equivalent by determining whether the 3 means are really the same number, statistically speaking. Do this by computing the mean of the 3 means, n all, and the corresponding χ 2 : χ 2 = n n a all + n n b all + n n c all 2 2 σ na σ nb σ nc 2. From the χ 2 distribution, the most likely value of χ 2 is 2. Why? If you have access to Excel (use CHIDIST) or MATLAB (or equivalent), you can get the probability that your value of χ 2 > 2. If this probability is not too small, say greater than 10%, then you have shown that the hypothesis is true (statistically speaking of course!). 5