Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Similar documents
Defining quality standards for the analysis of solid samples

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

of mass spectrometry

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Introduction to Fourier Transform Infrared Spectroscopy

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Introduction to Fourier Transform Infrared Spectroscopy

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

for XPS surface analysis

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

HILIC Method Development in a Few Simple Steps

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

MetWorks Metabolite Identification Software

Fast, Effective XPS Point Analysis of Metal Components

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

IN QUALITATIVE ANALYSIS,

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Thermo Scientific 253 Plus 10 kv Isotope Ratio MS. Utilize the Gold Standard. in isotope ratio MS. Robustness Sensitivity Precision

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Elemental Analysis: CHNS/O characterization of polymers and plastics

Thermo Scientific GasBench II

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Elemental Analysis: NCS characterization of paper

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

ICP-MS. High Resolution ICP-MS.

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Monitoring Protein PEGylation with Ion Exchange Chromatography

Keysight Technologies Young s Modulus of Dielectric Low-k Materials. Application Note

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

AN2970 Application note

Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers

Expanded capabilities in ammonium and amine detection

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

Key Words Q Exactive Focus, Orbitrap, veterinary drugs, small molecule HRAM quantitation, small molecule HRAM screening, UHPLC, vdia

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

TECHNIC A L WORK ING GROUP ITWG GUIDELINE ON SECONDARY ION MASS SPECTROMETRY (SIMS)

[ Care and Use Manual ]

Application of the GD-Profiler 2 to the PV domain

Keysight Technologies Measuring Substrate-Independent Young s Modulus of Low-k Films by Instrumented Indentation. Application Note

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases

Complete Materials Deformulation Using TGA-IR

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Prima PRO Process Mass Spectrometer

Keysight Technologies Oxygen-Free High-Resolution Electrochemical SPM. Application Note

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

PERSPECTIVE STABLE ISOTOPE RATIO MS

Cyclone Click to go to the page. Cyclone

Utility of the Charge Detector in Ion Chromatography Applications

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Ideal and powerful solution

Quantitation and Characterization of Copper and Nickel Plating Bath Additives by Liquid Chromatography

Transcription:

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer Defining quality standards for the analysis of solid samples

Redefine your quality standards for the elemental analysis of solid samples The Thermo Scientific ELEMENT GD PLUS GD-MS redefines the analysis of advanced high purity materials directly from the solid. Extra low detection limits are provided with minimum calibration and sample preparation effort, making bulk metal analysis and depth profiling applications the domain for GD-MS. Ceramics and other nonconductive powders are analysed by using a secondary electrode approach, providing the same level of sensitivity and data quality. This makes GD-MS the reliable standard method for metal analysis.

3 The ELEMENT GD PLUS GD-MS mass spectrometer is tailored to serve high purity material manufacturers and their customers in industries such as: Aerospace: nickel super alloys, depth profiling of coatings and diffusion layers Microelectronics: copper, alumina powder, sputter targets Renewable energy: silicon blocks, wafers, solar cells Medical/pharmaceutical/food: stainless steel, alloys Nuclear: uranium, nuclear fuel

Incomparable speed, sensitivity, accuracy The ELEMENT GD PLUS GD-MS combines components with superior attributes into one instrument incomparable in speed, sensitivity and accuracy. Technology Overview Micro second pulsed, fast flow, high power glow discharge ion source - Short analysis time due to comparatively high sputter rates - Superior sensitivity - Low level of polyatomic interferences compared to static GD sources - Widely adjustable working range for pulsed mode operations - Uniform crater shape, flexible anode diameter State of the art double focusing mass spectrometer - Incomparable signal to noise ratios resulting from high ion transmission combined with a low background leading to sub-ppb detection limits - Maximum level of selectivity and accuracy due to high mass resolution: a prerequisite for indisputable analytical results More than 12 orders of magnitude automatic detection system - Determination of ultra-traces and matrix elements within a single scan, due to a fully automatic detector with > 12 orders of linear dynamic range - Direct determination of the matrix elements for IBR (Ion Beam Ratio) quantification Excellent abundance sensitivity - Minimum contribution of high matrix signals on neighboring analyte peaks State-of-the-art software suite for productivity and ease-of-use - Full computer control of all parameters - Fully automated analysis and data evaluation - LIMS connectivity with automatic data transfer - Control and diagnostic - Microsoft Windows 7 Operating System Quantitative multi-element analysis across the periodic table Resolution switching time <1 second. Less than 10 minutes sample turn-around for many applications Matrix to ultra-trace detection capabilities in a single scan Depth profiling from sub-ppm to 100% with nanometer depth resolution Minimum matrix effects for straightforward semiquantitative quantification

5 High throughput and routine operation The ELEMENT GD PLUS GD-MS ion source including its sample holder is designed for easy sample change-over, offering routine operation and high throughput. Easy Sample Handling The ingenious and yet simple design of the Glow Discharge Source The sample can quickly and easily be removed from the ion source, reduces sample switching time to a fraction of the time it used to simply unloaded and re-loaded, and repositioned for the next be. The sample itself is placed in a vacuum chamber, eliminating measurement. Opening and closing of the ion source manifold any risk of leakage between the sample and the GD cell. is fully automatic.

Fast and easy sample to sample switching The Ion Source A glow discharge occurs when a potential difference is applied between two electrodes in a cell filled with gas at reduced pressure. In a configuration for elemental analysis the sample acts as the cathode, and its surface is sputtered by impacting gas ions. The sputtered particles, mostly neutral atoms, are ionized downstream in the plasma. Because the processes of sputtering and ionization are separated, especially in pulsed mode operation, minimal non-spectral matrix effects are observed. Therefore, perfect conditions can be achieved for the establishment of Relative Sensitivity Factors (RSF), enabling quantitative analysis or using simple Ion Beam Ratios (IBR) for semi-quantitative analysis. Typical Discharge Parameters Discharge gas flow (typically): 300-500 ml/min Voltage: 500-1400 V Current: 5-75 ma The ELEMENT GD PLUS GD-MS ion source offers generally high, although widely adjustable sputter rates and a simple and fast sample change-over, providing routine operation and high throughput without any compromise in performance. Pulsed mode operation results in significantly higher ionization efficiency at lower sputter rates, reducing the amount of deposits in the source. High throughput is additionally supported by electronic (Peltier) sample cooling (or heating), eliminating the need for cooling with cryogenic gases as required in other GD-MS instruments. There is a much reduced requirement for perfectly flat samples because the sample is not used as a vacuum seal.

7 Characteristics of the Glow Discharge Source High sensitivity for short analysis times Fast and simple sample to sample switching Low level of polyatomic interferences without the need for cryo-cooling Complete set of consumables for ultra-high purity and medium purity analysis Flexible cell for flat samples, pressed powders and pin samples (optional sample holder) Plug-in cone and anode parts for quick exchange eliminates the risk of cross contamination Sputter rates widely adjustable for bulk analysis or depth profiling Large sputtered sample area for representative surface sampling, minimizing inhomogenities in the material Flexible anode diameter for advanced depth profiling applications

Measure 50 elements at low ppb within 5 minutes The Mass Spectrometer The ELEMENT GD PLUS GD-MS uses advanced high resolution magnetic sector Any combination of resolution setting can be performed within a single field technology. The primary limitation of GD-MS is the presence of spectral analysis. The patented fixed-slit design guarantees maximum stability and interferences arising from the combination of matrix elements and the discharge reproducibility. gas with other species in the plasma. Consequently high mass resolution is The reverse Nier-Johnson sector geometry ensures excellent abundance a prerequisite for the accurate determination of analytes, separated from the sensitivity of < 10 ppb in copper matrix, determined as the background signal majority of possible interferences. on m-1 (mass 62 vs. mass 63). The analyzer is optimized for speed and mass The mass spectrometer of the ELEMENT GD PLUS GD-MS provides stability. The magnet is designed for the mass range 1-260 u, just right for the interference free measurements resulting in simple linear calibration curves demands of elemental analysis. It is relatively small, highly laminated, water for quantification. Three fixed resolution settings, with switching times of cooled and driven by a sophisticated high power regulator, resulting in minimum < 1 s, ensure optimum conditions to reliably remove spectral interferences. magnet switching and settling times.

9 High precision and accuracy of the mass calibration is vital for short analysis times, allowing precise peak top jumping. Due to the fully automatic mass locking process, mass calibration is no longer a regular procedure. Key features of the ELEMENT GD PLUS GD-MS Sensitivity (peak height, total ion current): > 1 x 1010 cps, (1.6 x 10-9 A) for copper in medium resolution (R 4000) Resolution: LR 300, MR 4000, HR 10000 switchable within < 1s Mass stability: < 25 ppm / 8 hour Abundance sensitivity: <10 ppb (determined as m-1/m in copper, medium resolution) Scan speed: < 150 ms from m/z 7 to 238 to 7

Dynamic beyond limits A sophisticated detection system completes the refined design of the ELEMENT GD PLUS GD-MS mass spectrometer. Detection System Typical applications involve the simultaneous analysis of matrix elements (%), In the ELEMENT GD PLUS GD-MS instrument this is achieved through the traces (ppm) and ultra-traces (ppb). To achieve this, the detection system offers: use of a unique and patented* combination of a dual mode (dark noise < 0.5 1012 cps) secondary electron multiplier (SEM) and a Faraday collector (maximum Wide dynamic range: 0.5 cps to > cps High speed: down to 1 ms integration time current > 1012 cps). The Faraday detector is no longer a slow collector requiring Automatic, fast switching between different detection modes long analysis time: due to its fast detection electronics it does not suffer decay Automatic cross calibration between different detection modes or response times and allows integration times down to 1 ms.

11 >% Detector ranges for the ELEMENT GD mass spectrometer

Our complete portfolio for surface and bulk metal analysis. For your analytical challenges we offer a complete portfolio of solutions. Whether you need to determine thin layer compositions or ultra trace metals in bulk material, we can support you with expertise and technology, offered by our sales network and service support all over the world. Discover more: www.thermoscientific.com/metallurgy www.thermofisher.com/gd-ms www.thermofisher.com/gd-ms 2016 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Africa +43 1 333 50 34 0 Australia +61 3 9757 4300 Austria +43 810 282 206 Belgium +32 53 73 42 41 Brazil +55 11 3731 5140 Canada +1 800 530 8447 China 800 810 5118 (free call domestic) 400 650 5118 BR30066-EN 0316G Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland +358 9 3291 0200 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9494 Italy +39 02 950 591 Japan +81 6 6885 1213 Korea +82 2 3420 8600 Latin America +1 561 688 8700 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Norway +46 8 556 468 00 Russia/CIS +43 1 333 50 34 0 Singapore +65 6289 1190 Sweden +46 8 556 468 00 Switzerland +41 61 716 77 00 Taiwan +886 2 8751 6655 UK/Ireland +44 1442 233555 USA +1 800 532 4752