Fusion UV/Persulfate TOC Analyzer

Similar documents
Fusion UV/Persulfate TOC Analyzer

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Simplifying the Process: Automated USP 643 / EP

USGS District Laboratory, Troy, NY Dissolved Inorganic Carbon Analysis Standard Operating Procedure

United States EPA Method 415.3

TRL-TOC-M MODEL MODULAR TC/IC/TOC/TN ANALYZER FOR LIQUID AND SOLID SAMPLES. TRL-TOC-M Model TC/IC/TOC/TN Analyzers are designed to handle:

Total Organic Carbon, Total Nitrogen

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Standard Operating Procedure for the Analysis of Dissolved Inorganic Carbon CCAL 21A.1

SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Organic Carbon, Total (Low Level) (UV Promoted, Persulfate Oxidation) CAS # Total Organic Carbon TOC C

Chemistry Instrumental Analysis Lecture 27. Chem 4631

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

Examining the Role of TOC Analyzers in the Pharmaceutical Laboratory

2. Pharmaceutical industry

Total Organic Carbon Analysis of Solid Samples for Environmental and Quality Control Applications

SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer

DI 3500 Discrete Aoalvzer

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

costech instruments ECS 4010 Elemental Combustion System CHNS-O

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Automated multi-vapor gravimetric sorption analyzer for advanced research applications

Maximizing Sample Throughput In Purge And Trap Analysis

Thermo Finnigan LTQ. Specifications

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Protein Sequencer PPSQ-31A / 33A C297-E055B

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

2. Pharmaceutical industry

University Wet Chemistry Analyzer Packages

C146-E209. Headspace Samplers. HS-20 Series

Zinc Metal Determination Perkin Elmer Atomic Absorption Spectrometer AAnalyst Procedures

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler

SMARTCHEM 300 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

SMARTCHEM 200 STATE-OF-THE-ART DIRECT READ DISCRETE ANALYZER FOR AUTOMATED CHEMISTRIES

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

δ 13 C of DIC and carbonate samples: comparison of traditional mass spectrometry methods with an infrared spectrometry method

STANDARD OPERATING PROCEDURES

110 Lowell Rd Hudson, NH USA Tel:

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

SMARTCHEM 140 DIRECT READ DISCRETE ANALYZER FOR SIMPLE AND AUTOMATED CHEMISTRIES

Optimization of 1,4-Dioxane and Ethanol Detection Using USEPA Method 8260 Application Note

Chloride by Flow Injection Analysis (FIA)

Product Descriptions and Offerings

novaa 800 D Atomic Absorption Spectrometer

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

Elemental Scientific. Spike Recovery. Elemental Scientific

TO-15 Checklist Determination of VOCs in Air by GC-MS

Volatile Organic Compounds in Every Day Food

SMARTCHEM 140. DIRECt READ DISCREtE ANAlyZER FOR SIMPlE AND AUtOMAtED CHEMIStRIES

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

Determination of the Halogen Elements in the Deep UV Region of the Spectrum by ICP - OES

Analysis of domestic sludge using the Agilent 4200 MP-AES

Determination of Carbon d13c isotopic composition from DIC samples

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

Automating Wet Chemical Analysis

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Member of the envea Group. Automatic Mercury Analyzer for the Laboratory

Dr. OligoTM DNA / RNA / OLIGO SYNTHESIZERS

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

cobas e 411 analyzer Confidence in every result.

Thermo Scientific GasBench II

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

Hexavalent Chromium by Flow Injection Analysis (FIA)

Regulatory and Alternative Analytical Procedures are defined as follows 2 :

Application Note PB 401. Improve HPLC Sample Preparation in an Analytical Laboratory A New Automated Sample Preparation Process

Elemental Scientific. Stability. Elemental Scientific

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Headspace Technology for GC and GC/MS: Features, benefits & applications

S8 TIGER Series 2 for ASTM D 6443

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

AOAC Official Method 2016.xx. Determination of Total Sulfur in Fertilizers by High Temperature Combustion

System and JUREK ANNE. Introduction: in an in purge and. trap sampling. Discussion: As part of. consistent and reliable data. (MoRT) to.

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Finnigan LCQ Advantage MAX

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Low-Level Sulfur Compounds in Beer by Purge and Trap with a Pulsed Flame Photometric Detector (PFPD)

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

The Clinical Chemistry System that offers more so you do less!

Analysis. Introduction: necessary. presented. Discussion: As part of be carried. consistent and reliable data. (MoRT) to.

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

5. TOC in daily practice

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

GAS CHROMATOGRAPHY (GC)

Manganese III Digestion Method * (with chloride removal)

Focus XC + 6 Microwave capability = Infinity Explore Infinite Possibilities. with the Infinity Microwave Peptide Synthesizer

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

AutoChem II 2920 A Catalyst Characterization Laboratory

Transcription:

www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Fusion UV/Persulfate TOC Analyzer The Fusion Total Organic Carbon (TOC) Analyzer utilizes powerful Ultra Violet (UV) Persulfate oxidation allowing superior carbon liberation from even the most challenging matrixes. By implementing the patented Static Pressure Concentration (SPC) technology, the Fusion TOC Analyzer is able to achieve unprecedented low end sensitivity from a Non-Dispersive Infrared (NDIR) detector. The Fusion TOC Analyzer is designed to offer productivity for a wide variety of applications. Page 1 of 8

Advantages of the Fusion Auto-calibration for unattended calibration monitoring Intellidilution for automatically diluting a sample back into calibration range 21 CFR Part 11 functionality Turn-key method development Exportable reports in user-definable formats including metadata User friendly software Pre-programmed method features for pharmaceutical, drinking water and waste water Self-diagnostic capabilities including leak check Mass flow controller for reduced gas consumption and enhanced flow control Unparalleled Results The Fusion is designed to determine the carbon content in water and other solutions. Using safe and proven UV promoted persulfate oxidation of carbonaceous material to carbon dioxide (CO2) followed by NDIR detection of the CO2 product, the Fusion is sensitive from 0.2ppbC - 4,000ppmC. Varieties of carbon can be independently determined by selecting a pre-defined instrument method. These include: Total Carbon (TC) Inorganic Carbon (IC) Total Organic Carbon (TOC = TC-IC) Non-Purgeable Organic Carbon (NPOC or TOC by sparging) To determine TOC by the NPOC method, the Fusion uses a syringe driver and 7-port valve to accurately transfer samples and reagents to the reactor. It then uses carrier gas to transfer the reaction product (CO2) from the sample either to vent or to the NDIR detector in the following sequence: 1. Removal and venting of IC and POC by acidification and sparging in the IC sparger. 2. Following IC removal, an aliquot of the sparged sample is transferred to the UV reactor and persulfate reagent is added to oxidize the organic carbon, based on the following chemical reactions: a. Free radical oxidants formed b. Excitation of organics c. Oxidation of organics The oxidation products in Step 2 are swept into the CO2 selective NDIR detector. The exit valve from the NDIR is closed to allow the detector to becomepressurized. Once the gases in the detector have reached equilibrium, the concentration of the CO2 is analyzed. This pressurization of the sample gas stream in the NDIR, Static Pressure Concentration, allows for increased sensitivity and precision. It measures all of the oxidation products in the sample in one reading, compared to flow-through technology. The output signal is proportional to the Page 2 of 8

concentration of CO2 in the carrier gas, from the oxidation of the sample. The PC workstation uses the TOC TekLink software to control the above sequence of operations, process the detector signal, and report the final concentration of the sample based on linearized, multi-point calibration data. Applications and Industries Pharmaceutical Environmental Methods EPA 415.1-415.3, 9060A, Standard Method 5310C, ASTM D4779 and D4839, and prenv 13370, Cleaning Validation / USP TOC Method <643> / EP 2.2.44 / JP Unmatched Linearity This screen shot demonstrates the excellent linearity achieved using Teledyne Tekmar s patent pending Static Pressure Concentration for unparalleled results. Page 3 of 8

Features and Benefits Permeation Dryer A. Autosampler - The Fusion has a standard 40mL vial, 75-position integrated autosampler with an arm and carousel for position selection. Optional carousels are available with 90-position; 55mL vials or 120-position; 20mL vials. B. UV Oxidation Reactor The UV reactor is composed of a glass vessel and a UV light source. The Fusion introduces the sample and persulfate reagent into the UV reactor. The persulfate reagent, combined with UV light, oxidizes carbon in the sample. Tekmar s improved UV reactor increases sample conservation and improves radiation interaction with water samples and oxidant. C. Halogen Scrubber - The detector, which measures CO2, can be affected by halogens. To prevent analytical errors, the halogen scrubber removes chlorine and other halogens from the CO2 before it enters the detector. D. Septum Piercing Needle allows for the use of vial caps with a septa thus eliminating sample exposure time to the atmosphere. E. Syringe and Valve - The syringe driver is a precision measuring instrument that draws in and dispenses fluid. The syringe driver has a volume delivery range of 125µL to 25mL and sample delivery between 2mL and 10mL depending on the applied method. F. Moisture Control System (MCS) - consists of a mist trap and permeation dryer, both of which are designed to remove moisture from the sample. After oxidation of the sample, carrier gas sweeps CO2 and water vapor out of the UV reaction chamber. Next, the CO2 travels through the mist trap, where most of the moisture is collected and removed. The gases then travel to the Page 4 of 8

permeation dryer, which removes the rest of the moisture from the sample gas. G. IC Sparger - glass fritted vessel that holds the sample while purging the Inorganic Carbon (IC) out of the sample and preparing it for analysis. After the addition of acid, purge gas flows through the sparger, removing the IC from the sample. The Fusion can report IC for both IC only and TC- IC modes, or vent it into the atmosphere while in the TOC mode. Additional Features Mass Flow Controller (MFC) - The patented MFC regulates either flow or pressure depending on the mode of operation. It allows for higher flows for clean up between samples and allows the user to optimize the sparge flow for each sample. Because of the MFC, the instrument automatically validates the system integrity by recording the pressure each time a sample is run. The MFC also performs pneumatic integrity tests on valves to make sure they are leak tight. Intellidilution This intelligent feature detects when a sample is out of range and will dilute it back to within the calibration range. Intellidilution also has the ability to meet individual analytical needs due to pre-set ranges (non-dilution methods only). Autocalibration Using a single stock solution, the system will automatically dilute final volumes based on the users linearizing concentration requirements, thus eliminating the need for multiple manual preparations of the calibration standard concentration levels. This feature eliminates the likelihood of human error and minimizes labor time. Static Pressure Concentration (SPC) - After the sample oxidizes, it is swept into the detector and pressurized with carrier gas ensuring the entire sample is present. The Non-Dispersive Infrared (NDIR) detector then measures the concentration of carbon dioxide. As a whole, this patented sensing technology enables the Fusion to reach new levels of detection required by todays demanding analytical requirements. TOC TekLink Fully Optimized User Interface Tekmar TOC TekLinkTM software allows the user to enter all analysis parameters and then once activated, will continuously monitor the system ensuring operating limits are not exceeded. TOC TekLinkTM is capable of performing useful diagnostics such as leak and benchmark tests for validation. All instrument parameters, method scheduling, and editing can be programmed. TOC TekLinkTM provides pre-developed methods, allowing startup with little or no modifications and also contains 21 CFR Part 11 compliance tools. Page 5 of 8

Specifications Chemistry: Photochemical Oxidation via UV-Persulfate1 Detector: Nondispersive Infrared (NDIR) with Static Pressure Concentration (SPC) - Patented Analytical TOC (NPOC), TC- IC, TC,IC Modes: Analytical: Limit of Detection: 0.2 ppb Maximum Measurable Concentration: 4,000 ppm (sample volume and dilution dependent) Carryover: = 1.0% Cross Contamination Page 6 of 8

Complete Process and Analysis Time: Controller: 21 CFR Part 11 Software Control: Data Handling: Precision*: = 1.0% RSD,+/-2 ppb or +/- 0.02 µgc, typical of a mid-range standard (Whichever is greater over seven replicates). * Analytical performance affected by laboratory water, reagent and gas purity, as well as sample container cleanliness, sample matrix, gas regulator cleanliness and precision, and operator skill. 4-8 minutes typical for TOC analysis; Typically 12-22 minutes for Triplicate TOC Analysis PC, Interface through Windows XP or greater TOC TeklinkTM Software is a 21 CFR Part 11 tool for your laboratory compliance Pre-defined Industry Standard Methods and Customized User Defined Methods Priority samples via schedule interrupt Real-time and Historical graphical display of NDIR detector data Reports exportable XML and HTML format Recalculation of data, outlier deletions, and precision performance criteria controls Calibration: Ability to view historical results from multiple schedules on one graphical display Auto-Calibration from Single Stock Standards or User Calibration Standards Multi-point (Linear or Quadratic) and auto-blanking Ability to use one calibration curve and blank for entire instruments analytical range Auto-Check Standards from Single Stock Standards or User Calibration Standards Other Features: - Pass / Fail Criteria - Decision Control upon Failure (Halt, Re-Calibrate, or Continue) Auto-System Suitability with Performance Auto-Leak Check Measurements Automatic Auto-dilution of samples/standards shutdown/standby Validation Support Package Available Self-cleaning sample Pre-programmed point and click method setup handling Page 7 of 8

Official Methods: Dimensions: Carrier Gas Supply: Inlet Carrier Gas Pressure: Programmable flow rate and pressure control and monitoring process that cleans reactor chambers on every repetition Intellidilution EPA 415.1-415.3, 9060A, Standard Method 5310C, ASTM D4779 and D4839, and prenv 13370, Cleaning Validation / USP TOC Method <643> / EP 2.2.44 / JP 18 inches (45.7 cm) W x 24.5 inches (62.2 cm) D x 32 inches (81.3 cm) H 99.99% pure nitrogen cylinder; 99.5+% nitrogen (with optional Piccolo Nitrogen Generator) 65 to 100 psi Windows is a registered trademark of Microsoft, TekLink is a registered trademark of Teledyne Tekmar Company. Covered by one or more of the following patents: 7,651,866 and other patent pending. 1UV Lamp contains Mercury, Do Not Put In Trash. Recycle or Dispose as Hazardous Waste. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Page 8 of 8