Rapid Speciation and Determination of Vanadium Compounds in Water Samples

Similar documents
Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Authors: C. Derrick Quarles, Jr. *, Patrick Sullivan, M. Paul Field, Hwan Kim, and Daniel R. Wiederin

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

DISCLAIMER: This method:

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Trace Analysis of Hexavalent Chromium using IC-ICP-DRC-MS

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Basic and Application Inductively coupled plasma mass spectrometry (ICPMS)

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Determination of Adsorbable Organic Halogen in Wastewater

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Trace Analyses in Metal Matrices Using the ELAN DRC II

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Real World Analysis of Trace Metals in Drinking Water Using the Agilent 7500ce ICP-MS with Enhanced ORS Technology. Application. Authors.

Agilent Technologies at TIAFT 2013

A Comparison of Arsenic Speciation

Low Level Detection of Priority Inorganic Pollutants in Water. Anthony Neumann, MSc Darren Crichton, BSc

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Fergus Keenan Shona McSheehy Julian Wills

ICP-OES Application Note Number 35

Glyphosate in all its forms

Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ

Development of a Sampling and Analysis Method for the Measurement of Hexavalent Chromium in Ambient Air

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Handling Interferences in the Modern Laboratory with Advanced Triple Quadrupole ICP-MS Technology

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Determination of urea in ultrapure water by IC-MS/MS

ICP/MS Multi-Element Standards

PRINCIPLE OF ICP- AES

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Dionex IonPac AS28-Fast-4µm column

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

Chromatographic Methods of Analysis Section - 4 : Ion Exchange Chrom. Prof. Tarek A. Fayed

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Voltammetry. Voltammetry. An Introduction in Theory. Metrohm Ltd. CH-9100 Herisau Switzerland

Analysis Repeatability of Trace and Major Elements in a Water Sample

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Prof. Dr. Biljana Škrbić, Jelena Živančev

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

Simultaneous Arsenic and Chromium Speciation by HPLC/ICP-MS in Environmental Waters

Partial Energy Level Diagrams

Samples compliant with the WATER

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Arsenic Speciation in Chicken. Mary Carson, Ph.D. FDA/CVM/OR/ Division of Residue Chemistry

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

ISO INTERNATIONAL STANDARD

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Current State of Extraction Don t Be Deceived! Sharon F. Webb, Ph.D. Director of Quality Program

Rapid, simple, interference-free analysis of environmental samples using the XSERIES 2 ICP-MS with 3 rd generation CCT ED

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

ENVIRONMENTAL CHEMICAL ANALYSIS

DEVELOPMENT AND VALIDATION OF NEW ANALYTICAL METHOD FOR BIOACTIVE COMPOUNDS

Cation Exchange HPLC Columns

Advances in Interference Removal for Accurate Arsenic Analysis in Food and Beverages

Luminescence transitions. Fluorescence spectroscopy

Elemental Scientific. Stability. Elemental Scientific

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Expanded capabilities in ammonium and amine detection

elemental state. There are two different possibilities: DESCRIPTION 1. One cation (+ ion) replaces another. 2. One anion (- ion) replaces another.

Implementing EPA Method 6020 with the Agilent ICP-MS Portfolio

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Introduction to Pharmaceutical Chemical Analysis

Elemental Scientific. Spike Recovery. Elemental Scientific

Chem 110 General Principles of Chemistry

Priority Pollutants in Untreated and Treated Discharges from Coal Mines

Removal of vanadium from neutralized acid mine drainage (AMD) by adsorption to saw dust

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Determination of trace anions in concentrated hydrofluoric acid

Determination of Elements at Sub-ppb Concentrations in Naphtha Mixtures Using the NexION 300 ICP-MS

Separation of Toxic Metal Cations on Stannous Silicate layers in Micellar TLC

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Determination of Nanoparticle Sizeand Number Concentration using the npquant Evaluation Module for Qtegra ISDS. The world leader in serving science

Transcription:

Rapid Speciation and Determination of Vanadium Compounds in Water Samples Speaker 1: Wei Liu Ph.D., MBA Thermo Fisher Scientific Speaker 2: James Harrington Ph.D., Research Triangle Institute 1 The world leader in serving science

Outline U.S. drinking water regulations Metals regulations in drinking water Metals speciation and methods IC-ICP-MS as a tool for metals speciation Speciation resources 2

Safe Drinking Water Act and EPA Drinking Water Regulations Safe Drinking Water Act (SDWA): Public Health Service Act (PHSA) in 1912 and revised to become SDWA in 1974 Amended in 1986 and 1996 Authorizes EPA to regulate drinking water to protect the public health EPA drinking water regulations: Started to regulate drinking water contaminants in 1912 Currently regulate more than 90 contaminants including 17 metal elements Evaluate unregulated contaminants 3

Regulated Contaminants and Unregulated Contaminants SDWA 1996 amendment The U.S. EPA Regulated contaminants Unregulated contaminants 6-year review Possible modification Contaminant candidate List (CCL) CCL 1 CCL 2 CCL3 CCL4 Unregulated Contaminant Monitoring Rule UCMR1 UCMR2 UCMR3 UCMR4 Every five years 4

Metals (and Metalloid) Regulations in Drinking Water National Primary Drinking Water Regulations: legally enforceable standards that apply to public water systems. Secondary list: non-enforceable guidelines to regulate contaminants: May cause cosmetic effects (such as skin or tooth discoloration), or Aesthetic effects (such as taste, odor, or color) in drinking water Primary: Sb, As, Ba, Be, Cd, Cr, Cu, Pb, Hg, Se and TI Regulated Unregulated Secondary: Al, Cu, Fe, Mn, Ag, and Zn UCMR3: V, Mo, Co, Sr, Cr, Cr (VI) CCL4: V, Mo, Co, Te (Jan 2015) UCMR4? (2016) 5

Metals Speciation Speciation analysis: to identify and quantify different species (chemical forms) of a particular metal element Metals Species 1 Species 2 Species 3 Antimony Sb (III) Sb (V) Arsenic As (III) As (V) Organoarsenic Chromium Cr (III) Cr (VI) Mercury Hg2+ Methylmercury Ethylmercury Selenium Se (IV) Se (VI) Others Vanadium V (IV) V (V) 6

Metals Speciation and its Importance Why is speciation important? Study of the health effects: toxicity Safety purpose: bioavailability and reactivity Understanding of geochemical changes: mobilization and transformation Truth about speciation: A toxic species is more relevant than the total concentration (California Cr (VI)) Speciation analysis is important but not required in new regulations yet A few speciation analytical methods are in draft form, very few got approved by EPA (321.8 for bromine speciation) and ASTM (D6994-04 for cyanide speciation) 7

Principles of Speciation Analysis Sample containing various compounds Separation Individual detection of compounds Preservation of original species distribution during sample preparation and storage: -Loss of species -Transformation of species Different separation mechanisms: Charges Different species must be well separated Ability to tackle several analytes with same instrumentation ICP-MS accurately determines the total element concentration within each separated fraction of the species 8

Commonly Used Techniques for Speciation GC-ICP-MS Gas chromatography for separation and ICP-MS for detection Example: mercury speciation IC-ICP-MS (IC sometimes is called HPIC or even HPLC) Ion chromatography for separation and ICP-MS for detection Example: arsenic speciation HPLC-ICP-MS HPLC or UHPLC for separation and ICP-MS for detection HPLC-Q-ICP-MS or HPLC-HR-ICP-MS Example: vanadium speciation CE-ICP-MS Capillary electrophoresis for separation and ICP-MS for detection Example: arsenic speciation 9

Arsenic Speciation: CE-ICP-MS and IC-ICP-MS Capillary electrophoresis Sun et al. Journal of Chromatography A, 1039 (2004) 201 208 Advantage: short analysis time, high separation efficiency, and low operating cost Disadvantages: High detection limit (100x higher detection limit than IC), high RSDs (can be >30%) IC-ICP-MS for arsenic speciation Thermo Scientific AN43099 10

Speciation: Ion Pair and Ion Exchange Chromatography Ion Pair(ing) Chromatography Anionic, neutral and cationic species are separated in only one chromatographic run Both are ion chromatography Ion (Exchange) Chromatography Low ph: Thermo Scientific Dionex TM AS7 or AS4 column with HNO 3 as eluent High ph: Dionex AS 7,11, 14, 16 column with eluent of carbonate and hydroxide TN12 IonPac NS1 column Ammann (2011) review on arsenic speciation Jackson and Bertsch (2001) AS16 column for arsenic species separation 11

A Complete Integrated IC-ICP-MS System IC-ICP-MS is a fully integrated technique One software and simple hardware connection The completely metal-free IC system eliminates contamination by the system Large range of IC columns Tailored IC applications Flexibility and support to develop applications For many elemental speciation applications IC is the preferred chromatographic choice for ICP-MS: Mobile phases are simpler/cleaner for lower interferences, lower background and lower limits of detection Narrower bore columns (2 mm ID) for higher efficiency separation and lower mobile phase consumption Thermo Scientific icap Q ICP-MS Inert tubing 0.125 mm i.d. Data System Thermo Scientific Dionex ICS 5000+ system Thermo Scientific Qtegra Intelligent Scientific Data Solution software 12

The difference between Q-ICP-MS and ICP-SF-MS The power of high resolution Q-ICP-MS ICP-MS with quadrupole analyser: No separation between the analyte (m/z 59.93) and the interferences (m/z 59.958, 59.982) ICP-MS with magnetic sector field analyzer: separation of the analyte from the interferences by their small mass difference (High Resolution) Medium Resolution m/z 60 60 Ni + 44 Ca 16 O + 23 Na 37 Cl + 23 Na 2 14 N 12 C 16 O 3 ICP-SF-MS: medium resolution R=4000 13

Comparison of ICP-MS and SF-ICP-MS in Speciation AN 30127 The chromatograms show identical peak shapes and retention times SF-ICP-MS has much lower detection limit compared to ICP-MS 14

Resources for Speciation Webinars: Complete Inorganic Elemental Speciation Solutions for Environmental Applications Bromine Speciation in Ozonated Drinking Water Using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry (June 9) Speciation web site: http://www.thermoscientific.com/en/abo ut-us/videos/speciation-using-ic-icpms.html European Virtual Institute for Speciation Analysis: www.speciation.net Application notes/notebook/white papers: Application notebook: Speciation Application Summary Ion Chromatography: Trace Elemental Species Separation and Detection Application note 43098: Speciation Analysis of Cr(III) and Cr(VI) in Drinking Waters Application note 30127: Speciation of Trace Elemental Species using GC-ICP- MS and GC-HR-ICP-MS White Paper: Coupling of an Inert Ion Chromatographic System with ICP-Q-MS for Robust and Accurate Elemental Speciation White paper: Benefits of Coupling IC with ICP/MS 15

Thank You for Your Attention! Stay connected with us Twitter @ChromSolutions Analyte Guru Blog http://analyteguru.com/ YouTube http://www.youtube.com/chromsolutions Questions? Facebook http://www.facebook.com/chromatography Solutions Pinterest http://pinterest.com/chromsolutions/ 16

Speciation of Vanadium by IPRP-UPLC-ICP-SF-MS Introduction Vanadium in the environment Vanadium chemistry and environmental implications Chromatographic Method development Mechanism of separation Variation of mobile phase components Spectrometric analysis Separation vs resolution Calibration and quantification Application to an environmental sample Conclusions and Future Directions

What Is RTI International RTI is an independent, nonprofit institute that provides research, development, and technical services to government and commercial clients worldwide. $800M FY14 revenue, reinvested in programs, facilities, capabilities. Our mission is to improve the human condition by turning knowledge into practice.

History, Facts and Figures Established in 1958 Collaboration among state government, area universities, and business leaders Over 3,700 staff in 75 countries Over 130 academic disciplines spanning social and natural sciences, international development, etc. Headquartered in RTP, NC, satellite offices around the world 180-acre RTP campus, with 22 buildings and 900,000 sq ft

Laboratory and Chemistry Services Methods development and evaluation Testing and analytical services Lab testing and quality standards

Environmental Research Services Air and water quality Waste management Climate change Risk assessment Sustainability Site assessment and remediation Environmental and natural resource economics

Vanadium in the environment Included on EPA Drinking Water Contaminant Candidate List. Concentration in the environment 3-310 µg/g (ppm) in soil 0.2-100 µg/l (ppb) in fresh water 0.2-29 µg/l in seawater Sources of environmental emission Coal combustion emissions Fly ash Vehicle emissions Metallurgic production (WHO Air Quality Guidelines, 2000)

Oxidation states Vanadium chemistry -1 1 2 3 4 5 VO - 3 or VO + Synthetic, unstable V 3+ VO 2+ 2 Isotopes 51 V (99.75%) and 50 V (0.25%) Chemistry V 2+ Resembles phosphate in environment/biology Can form polymeric species V(V) is an oxidizing agent, more toxic V(IV) has antidiabetic properties

Vanadium Speciation - Toxicity Listed as an NTP Priority Contaminant Differential acute toxicity of Vanadium species VOSO 4 5 H 2 O Rat oral administration LD 50 98.0 mg/kg BW Rat oral administration LD 50 448.0 mg/kg BW Symptoms Diarrhea, irregular respiration, decreased locomotor activity. Llobet, J.M., Domingo, J.L., Tox Lett (1984), 23, 227-231

Speciation of Vanadium compounds Speciation varies with conditions ph, redox chemistry, species stability Low ph III, IV; High ph V Liquid chromatographic separation can separate based on charge Method must stabilize speciation, provide accuracy at low concentration Detection methods: UV-Vis, AA, ICP-OES: Insufficient sensitivity for low (ppb-ppt) concentrations ICP-MS low (ppb-ppt) level quantification Photo courtesy of Wikipedia Al-Kharafi, F. M.; Badawy, W. A. (1997). "Electrochemical behaviour of vanadium in aqueous solutions of different ph". Electrochimica Acta 42 (4): 579 586. Cadmium @ Wikipedia

Ion pairing reverse phase chromatography RP chromatography Organic mobile phase Requires O 2 addition, interferes with plasma Carbon deposits on cone Ion pairing RP chromatography Non-polar ion pairing agents separate ions on non-polar stationary phase Less organic mobile phase. Separates based on polarity and charge Easy to modify separation by varying ph Previously applied to As, V in other matrices, etc. C 18 C 18 C 18 C 4 H 9 C 18 C 18 C 18 C 18 C 18 C 4 H 9 + N C 4 H 9 C 4 H 9

Experimental UHPLC Waters ACQUITY system Column: Acquity BEH C 18 (1.7 µm), 2.1x50 mm Mobile phase: 18 mm EDTA, 0.50 mm tetrabutylammonium hydroxide (TBAOH), 20 mm H 3 PO 4 ph 7.00 w/ NH 4 OH, 4% MeOH Temp: Amb, 0.60 ml/min, isocratic (P ~ 10,000 psi) ICP-SF-MS Thermo Scientific Element 2 ICP-MS system Ni cones, ESI PC3 peltier-cooled cyclonic spray chamber 1475 W FP, Pt guard electrode 51 V isotope Low resolution (M/ΔM ~ 350) Medium resolution (M/ΔM ~ 6000)

Why UHPLC? Ultra-high performance liquid chromatography Higher resolution more theoretical plates Faster separation higher throughput Literature HPLC/CE methods Retention time - ~5-10 min. CE drifting retention times IEC-ICP-AES Takaya and Sawatari, Indus. Health (1994) 32, 165-178 use; retention ~10 minutes for V(V), LOQ 1 ppm Our method complete separation ~1 min

Omitting mobile phase constituents varies selectivity TBAOH No ion pairing agent Method development Mobile phase No retention for either charged species, elutes with the void No resolution C 4 H 9 C 4 H 9 + N C 4 H 9 C 4 H 9 Kilibarda, Afton, Harrington, Yan, and Levine, J. Chrom. A 1304 (2013) 121-126.

Method development mobile phase EDTA No complex, no displacement No nonpolar core No complex, ions higher charge, reverse order No EDTA to displace V ions Decreased oxidative stability EDTA controls rate of oxidation Controls inner sphere Minimizes inner sphere electron exchange Kilibarda, Afton, Harrington, Yan, and Levine, J. Chrom. A 1304 (2013) 121-126.

Alternate eluent components Other complexing agents for V speciation 2,6-pyridinedicarboxylic acid w/ lithium hydroxide Decreased species stability degradation after 2 hours Less stable complexation, less able to control inner coordination redox Different column, so different selectivity/separation mechanism. M.J. Tomlinson, J. Weng, J.A. Caruso, JAAS (1994) 9, 957-964. 4-(2-Pyridylazo)resorcinol Chromophore, UV-Vis detection Non-vanadium-specific chelation Interference by other metal ions Pre-treatment step and developing step, highly susceptible to pre-treatment process and ph S.J. Tsai, S. Hsu, Analyst (1994) 119, 403-407.

Varying ph varies selectivity Method development Mobile phase Varies EDTA protonation, charge pk a3 = 6.16 Phosphate - pk a2 = 7.21 Complex protonation does not vary Displacement by free EDTA varies Order of elution unchanged ph, Resolution and RT ph 7 full resolution (R s = 1.63), short RT Kilibarda, Afton, Harrington, Yan, and Levine, J. Chrom. A 1304 (2013) 121-126.

Method development Mobile phase Must balance mobile phase composition w/ ionic strength ionic strength, instrumental sensitivity Aureli, et al., JAAS (2008), 23, 1009-1016 reported decreasing sensitivity at higher concentrations of carbonate buffer, EDTA salt Increase in EDTA higher carbon content Requires organic (MeOH), but may affect complex speciation Previous reports - >4% MeOH

Separation vs Resolution 51 V polyatomic interference - 35 Cl 16 O Medium Res Low Res Complete resolution of vanadium species 20 mm NaCl Kilibarda, Afton, Harrington, Yan, and Levine, J. Chrom. A 1304 (2013) 121-126.

Calibration and quantification Calibration range 0.25 25.0 ppb Spiked eluent stds LOD V(IV) 0.008 ppb V(V) 0.013 ppb Nominal [V(IV)] = [V(V)] = 2.50 ppb V(IV) V(V) Standard Nominal Calc Amt % Diff Calc Amt % Diff Cal1 0.100 0.181 80.7 0.192 92.2 Cal2 0.250 0.317 26.7 0.309 23.7 Cal3 0.500 0.557 11.4 0.550 10.07 Cal4 1.000 1.036 3.60 1.024 2.44 Cal5 2.500 2.509 0.36 2.506 0.23 Cal6 5.000 4.923-1.54 4.932-1.37 Cal7 10.000 9.828-1.72 9.863-1.365 Cal8 25.000 25.080 0.32 25.065 0.260

Species Stability Good intraday (same day) stability Solvent standards measured within 4 hrs No conversion, but variation in recovery due to instrumental drift Interday (different day) stability 7-day autosampler stability Nominal 5.0 ppb Variation artefact of cal fit V4 V5 Standard Nominal Calc Amt % Diff Calc Amt % Diff Cal1 0.100 0.121 20.6 0.147 47.5 Cal2 0.250 0.272 8.71 0.295 17.9 Cal3 0.500 0.523 4.57 0.538 7.65 Cal4 1.000 1.009 0.926 0.995-0.472 Cal5 2.500 2.475-0.990 2.496-0.180 Cal6 5.000 5.171 3.42 4.880-2.39 Cal7 10.000 9.947-0.529 10.001 0.0128 Cal8 20.000 19.873-0.633 19.919-0.404

X-Series II analysis Comparison of other instruments Ni cones, NH 3 CCT gas 8.0 ml/min (nominal [V] = 5.0 ppb) Separation comparable, S/N lower, comparable cal range. ELOQ ~1.00 ppb w/o smoothing

Lake water sample Collected at Falls Lake Filtered, diluted with mobile phase Analyzed within 24 hrs Spiked w/ nominal 5 ppb Measured ~ 1 ppb V(V) Environmental application Kilibarda, Afton, Harrington, Yan, and Levine, J. Chrom. A 1304 (2013) 121-126.

Conclusions Vanadium speciation is possible through application of chromatographic separation Ion pairing reverse phase separation is appropriate for environmentally relevant species Mobile phase composition can be varied to optimize selectivity Analysis of environmental samples allows quantification to 50 ppt Minimal matrix effect in natural fresh water on spike recovery N. Kilibarda, S. Afton, J. Harrington, F. Yan, and K. Levine, Rapid speciation and determination of vanadium compounds using ion-pair reversed-phase ultra-high-performance liquid chromatography inductively coupled plasma-sector field mass spectrometry, J. Chrom. A, 1304 (2013) pg 121-126.

Future applications Future directions Verification of analysis on other ICP systems X Series II, icap Q MS, etc Qcell Low Mass Cutoff Excludes O to prevent ClO formation Analysis of vanadium speciation in biological fluids urine, serum, etc Application of separation method to other elements - Cd, Fe, etc. Image courtesy of: ThemoFisher Scientific

Acknowledgements RTI International Internal research funding North Carolina Central University Nikola Kilibarda, Fei Yan Scott Afton

Resources for Speciation Webinars: Complete Inorganic Elemental Speciation Solutions for Environmental Applications Bromine Speciation in Ozonated Drinking Water Using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry (June 9) Speciation web site: http://www.thermoscientific.com/en/abo ut-us/videos/speciation-using-ic-icpms.html European Virtual Institute for Speciation Analysis: www.speciation.net Application notes/notebook/white papers: Application notebook: Speciation Application Summary Ion Chromatography: Trace Elemental Species Separation and Detection Application note 43098: Speciation Analysis of Cr(III) and Cr(VI) in Drinking Waters Application note 30127: Speciation of Trace Elemental Species using GC-ICP- MS and GC-HR-ICP-MS White Paper: Coupling of an Inert Ion Chromatographic System with ICP-Q-MS for Robust and Accurate Elemental Speciation White paper: Benefits of Coupling IC with ICP/MS 42