arxiv: v1 [physics.ins-det] 9 Apr 2016

Similar documents
Characterization of a high-performance Ti/Au TES microcalorimeter with a central Cu absorber

High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy

Metallic magnetic calorimeters. Andreas Fleischmann Heidelberg University

EURECA: the X-ray Universe in high spectral resolution

A TES Bolometer for THz FT-Spectroscopy

NIST designed cryostat

High speed photon number resolving detector with titanium transition edge sensor

Ir TES electron-phonon thermal conductance and single photon detection

Superconducting Quantum Interference Devices for Current Sensing and Thermometry in the Millikelvin Range

X-ray spectrometry with Peltier-cooled large area avalanche photodiodes

Detection of X-Rays. Solid state detectors Proportional counters Microcalorimeters Detector characteristics

The High Resolution X-ray Spectrometer, SXS, on the Astro-H mission

Future X-rayX Spectroscopy Missions. Jan-Willem den Herder

Detecting high energy photons. Interactions of photons with matter Properties of detectors (with examples)

PoS(extremesky2009)086

MoBiKID Kinetic Inductance Detectors for up-coming B-mode satellite experiments

The EBIT Calorimeter Spectrometer: a new, permanent user facility at the LLNL EBIT

arxiv: v1 [physics.ins-det] 13 Nov 2017

The Future of Neutrino Mass Measurements: Terrestrial, Astrophysical, and Cosmological Measurements in the Next Decade. Seattle February 8-11, 2010

SUPPLEMENTARY INFORMATION

M. Kenyon P.K. Day C.M. Bradford J.J. Bock H.G. Leduc

Ground Calibration of X-ray CCD Detectors with Charge Injection for the X-ray Imaging Spectrometer on Astro-E2

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

08 - Miscellaneous and historical detectors

X-ray Quantum Calorimeter (XQC)

The Athena X-ray Integral Field Unit

Instrumentation for sub-mm astronomy. Adam Woodcraft SUPA, University of Edinburgh

Micro & nano-cooling: electronic cooling and thermometry based on superconducting tunnel junctions

Document Number: SPIRE-UCF-DOC Issue 1.0. November Matt Griffin

Development of a gamma-ray detector with iridium transition edge sensor coupled to a Pb absorber

FUNDAMENTAL PARAMETER METHOD FOR THE LOW ENERGY REGION INCLUDING CASCADE EFFECT AND PHOTOELECTRON EXCITATION

Measurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers

arxiv:astro-ph/ v1 4 Sep 2001

PB I FEL Gas-Monitor Detectors for FEL Online Photon Beam Diagnostics BESSY

SEM. Chemical Analysis in the. Elastic and Inelastic scattering. Chemical analysis in the SEM. Chemical analysis in the SEM

ABSTRACT 1. INTRODUCTION

On the development of compound semi-conductor thallium bromide detectors for astrophysics

Centre for Electronic Imaging

ORTEC. SLP Series Silicon Lithium-Drifted Planar Low-Energy X Ray Detector Product Configuration Guide

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Performance Testing of the Astro-H Flight Model 3-stage ADR

detectors Cryogenic X-ray detectors for synchrotron science 1. Introduction: why cryogenic detectors at the synchrotron?

Hands on CUORE: investigation on the vibrations and temperature control of the cryostat

GEANT4 Simulations of. the LAXPC Performance. H. M. Antia. Tata Institute of Fundamental Research

Antiproton Decelerator at CERN, another advanced CCC for the FAIR project at GSI is under construction and will be installed in CRYRING. This

dc-squid current sensors for the readout of high-resolution Metallic Magnetic Calorimeters J. Beyer for MetroBeta consortium

Position calibration of cryogenic dark matter detectors

Special SLS Symposium on Detectors

X- & γ-ray Instrumentation

Direct Dark Matter and Axion Detection with CUORE

arxiv: v2 [astro-ph.im] 23 Jul 2018

How we wanted to revolutionize X-ray radiography, and how we then "accidentally" discovered single-photon CMOS imaging

Ultra-High Resolution Gamma-Ray Spectrometer Development for Nuclear Attribution and Non-Proliferation Applications

Multilayer coating facility for the HEFT hard X-ray telescope

Calorimetric approach to the direct measurement of the neutrino mass: the MARE project

Resistance Thermometry based Picowatt-Resolution Heat-Flow Calorimeter

Eugenio Monticone. Nanoscience and Materials Division Istituto Nazionale di Ricerca Metrologica

BENEFITS OF IMPROVED RESOLUTION FOR EDXRF

The intense, pulsed positron source EPOS at the Research Centre Dresden-Rossendorf

Abstract of Study of Vapor-Deposited Au:Er Films and Development of a Metallic

Multicolor mm/submm TES Bolometer Camera development for ASTE. Tai Oshima (NRO/NAOJ)

Calibration of Ocean Colour Sensors

Advances in the Micro-Hole & Strip Plate gaseous detector

Development of a Hard X-Ray Polarimeter for Solar Flares and Gamma-Ray Bursts

Supplementary Figures

Voltage-biased superconducting transition-edge bolometer with strong electrothermal feedback operated at 370 mk

IbIs Curves as a useful sensor diagnostic

Calibration of the IXPE Instrument

A NEW GENERATION OF GAMMA-RAY TELESCOPE

Bolometers for submm/mm-wave astronomy

arxiv: v2 [physics.ins-det] 8 Feb 2013

MEASUREMENT OF TEMPORAL RESOLUTION AND DETECTION EFFICIENCY OF X-RAY STREAK CAMERA BY SINGLE PHOTON IMAGES

CALCULATION OF THE DETECTOR-CONTRIBUTION TO ZIRCONIUM PEAKS IN EDXRF SPECTRA OBTAINED WITH A SI-DRIFT DETECTOR

Direct Dark Matter and Axion Detection with CUORE

MARE-1 in Milan: an update

Gamma and X-Ray Detection

Efficiency and Attenuation in CdTe Detectors

X-ray ionization yields and energy spectra in liquid argon

He-3 Neutron Detectors

The Chemical Control of Superconductivity in Bi 2 Sr 2 (Ca 1 x Y x )Cu 2 O 8+±

Research Center Dresden Rossendorf

COST MP0601 Short Wavelength Laboratory Sources

Check the LCLS Project website to verify 2 of 6 that this is the correct version prior to use.

SLS Symposium on X-Ray Instrumentation

Optimization of NSLS-II Blade X-ray Beam Position Monitors: from Photoemission type to Diamond Detector. P. Ilinski

An active-shield method for the reduction of surface contamination in CUORE

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Performance test of a G-M cooler in magnetic field

Formation of High-b ECH Plasma and Inward Particle Diffusion in RT-1

arxiv: v1 [physics.ins-det] 9 Apr 2018

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

The HXDS Solid State Detectors

Outline. Introduction, motivation Readout electronics, Peltier cooling Input J-FETsJ

estec NIRSpec Technical Note NTN Spectral intensity of the MSA glow sources Abstract:

CRYOGENIC CONDUCTION COOLING TEST OF REMOVABLE PANEL MOCK-UP FOR ITER CRYOSTAT THERMAL SHIELD

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

Status of the AMoRE experiment searching for neutrinoless double beta decay of 100 Mo

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Set-up for ultrafast time-resolved x-ray diffraction using a femtosecond laser-plasma kev x-ray-source

Spin-resolved photoelectron spectroscopy

Development of a cryogenic induction motor for use with a superconducting magnetic bearing

Transcription:

Journal of Low Temperature Physics manuscript No. (will be inserted by the editor) arxiv:1604.02535v1 [physics.ins-det] 9 Apr 2016 L. Gottardi Y. Takei J. van der Kuur P.A.J. de Korte H.F.C.Hoevers D. Boersma M. Bruijn W. Mels M. L. Ridder D. Takken H. van Weers Characterisation of a TES-based X-ray microcalorimeter in the energy range from 150 to 1800 ev using an Adiabatic Demagnetisation Refrigerator 23.07.2007 Keywords TES, X-ray calorimeter, superconductivity, synchrotron radiation Abstract We characterised a TES-based X-ray microcalorimeter in an adiabatic demagnetisation refrigerator (ADR) using synchrotron radiation. The detector response and energy resolution was measured at the beam-line in the PTB radiometry laboratory at the electron storage ring BESSY II in the range from 200 to 1800 ev. We present and discuss the results of the energy resolution measurements as a function of energy, beam intensity and detector working point. The measured energy resolution ranges between 1.5 to 2.1 ev in the investigated energy range and is weakly dependent on the detector set point. A first analysis shows a countrate capability, without considerable loss of performance, of about 500 counts per second. PACS numbers:07.20.fw,07.85.nc,85.25.am,85.25.oj,95.55.-n 1 Introduction We are developing an imaging array of Transition Edge Sensor (TES) microcalorimeters for future X-ray astronomy mission like EDGE (Explorer of the Diffuse emission and Gamma-ray burst Explosions) 1, XEUS 2 and Constellation-X 3. The experiment described here is part of the European-Japanese project EURECA, which aims to demonstrate technological readiness of a 5 x 5 pixel array of TES-based micro-calorimeters read-out by two SQUID-amplifier channels using frequencydomain-multiplexing (FDM) 7. We discuss here the details of the detector set-up SRON Netherlands Institute for Space Research, Sorbonnelaan 2, 3584CA, Utrecht, The Netherlands Tel.:+31-30-2538561 Fax:+31-30-2540860 E-mail: l.gottardi@sron.nl

2 vacuum can experiment DETAIL 55 K shield IR/UV filters cryoperm PbSn shield 4K shield 4K shield Fe55 source TES array coil FAA salt pils GGG salt pils 4T magnet Pulse tube SQUID harness thermal links IR/UV filters Fig. 1 (Color online) Cross section of the detector integrated in a two-stage Adiabatic Demagnetisation Refrigerator precooled by a Pulse Tube and the first results of the tests made using synchrotron radiation at the PTB beamline of the BESSY II 9. The aim of the campaign was to test the sensor behaviour to investigate crucial detector issues like calibration of the energy scale, non linearity, large signal analysis and energy resolution retrieval from pile-up events. 2 Experimental details A cross section of the experimental set-up is shown in Fig. 1. Tab. 1 gives a summary of the cooler and sensor main parameters ADR TES sensor parameter value parameter value Pulse tube Temperature 3.5 K Ti/Au area 146µm 150µm PT cooling power 350 mw Ti/Au thickness 25 nm (Ti), 50 nm (Au) GGG salt pills T 880 mk Cu abs. area 100µm 100µm FAA salt pills T 48 mk Cu abs. thickness 1000nm hold time at 73mK 24 h T C 100 mk magnetic field 4 T R N 143 mω G at T C 0.36 nw/k C 0.3 pj/k Power at T bath = 73mK 6.5 pw Table 1 ADR and TES microcalorimeter main parameters. At a TES resistance of R 0.5R N the thermometer sensitivity to temperature and current is respectively α 380 and β 2,[ 5 6 ] The sensor is a single-pixel of a 5x5 array and consists of a Cu absorber on top of a Ti/Au TES deposited on a Si x N y membrane, which provides a weak thermal link to the ADR bath temperature. The TES is voltage-biased with a R th = 10mΩ

3 (thevenin equivalent) load resistance, and kept at the transition by negative electrothermal feedback (ETF) 4. The current through the TES was measured by a 100-SQUID array 1 operated in flux locked loop (FLL). The inductance of the SQUID input coil is L s 70 nh. The SQUID array is directly read out by a low noise commercial PTB-Magnicon electronics 2. The detector has been integrated in a Janis two-stage ADR cooler precooled at 3.5 K by a mechanical Cryomech Pulse Tube (PT). To reduce the electro-magnetic interferences from the external environment, the detector cold-head, the harness and the room temperature electronics is fully enclosed in a dedicated Faraday cage. In the cold stage, the Faraday cage is formed by a double shield anchored at 3.5K consisting of a cryoperm shield and a copper load-tin plated superconducting shield. The cryostat is foreseen of windows along the optical path of the detector. We employ two 150 nm aluminium filters, each supported on a 200 nm parylene substrate, respectively placed on the 60 and 3.5 K cryostat shields. We characterised the detector using the soft X-ray two plane grating monochromator beam-line (SX700) in the PTB laboratory at BESSY II synchrotron facility in Berlin 9. The photons energy can be selected with high resolution (< 0.5 ev) in the range from 50 to 1800 ev. The radiation flux can be easily change from a few tenths to thousands of photons per second. 3 Results We report here the results of the measurement campaign at PTB-BESSY. A detailed characterisation of the single pixel thermal and electrical responsivity can be found in 5 6. We study the microcalorimeter detector by measuring the energy resolution in the energy range from 150 ev to 1.8 kev and for the microcalorimeter optimum bias point observed at R/R N = 0.46 and zero perpendicular magnetic field, B 0 mg obtained by cancelling the remanent magnetic field with an auxiliary superconducting coil. The base temperature was T bath = 73 mk and stabilised at a level of 7µK rms for all the measurements described in this paper. The dependence from the TES bias point and the applied perpendicular static magnetic field was also studied and will be discussed. In Fig. 2.a. the energy resolution is shown as a function of the incident photon energy. In the graph we plotted with full circles the X-ray energy resolution obtained after applying the matched filter to each single photon. The open circles show the baseline resolution obtained by filtering the detector noise with the same filter used for the X-ray pulses. When the instrumental resolution of the detector is dominated by random noise, the baseline resolution is equal to the X-ray resolution. At 250 ev we measured the best energy resolution of 1.52±0.03 ev (see insert of Fig. 2.a.). In the presence of electro-thermal feedback (ETF) and for large ETF loop gain L 0, the energy resolution can be approximated, in the small signal 1 kindly provided by NIST 2 Magnicon-PTB, www.magnicon.com

4 energy resolution FWHM [ev] 2.4 2.2 2 1.8 1.6 1.4 01 1.2 01 01 1 baseline-wf X-ray pulses-wf τ fall + excess noise de=1.56 ev 0.8 0 500 1000 1500 2000 energy [ev] τ fall [µ sec] a) b) 140 130 120 110 100 90 80 70 60 tau fall polynomial fit 00 11 50 00 11 40 0 500 1000 1500 2000 energy [ev] Fig. 2 a) X-ray (full circle) and baseline (open circle) energy resolution as a function of the photon energy for the TES optimal working point. The photon flux was of about 50 photons/sec. The theoretical (M=0) energy resolution for this detector at the working point discussed here, is estimated to be E th 0.6 ev. b) Pulse fall time τ f all as a function of energy. The dashed curve is the polynomial curve fitting the data. analysis, as E FWHM 2.355 4kT c τ f all P J0 (n(1+m 2 )/2) 1/4, (1) where T C is the TES transition temperature,α and β describe respectively the temperature and current dependent TES transition steepness and P J0 = I0 2 R is the steady-state Joule power. The pulse fall time is calculated to be τ f all = τ 0 /(1+ L 0 /(1+β)), where τ 0 = C/G and n = 3.7 is determined by the heat transport mechanism. M represents the ratio of the level of excess noise to the Johnson noise as described by Ullom et al. 8. The theoretical energy resolution (M = 0) for this sensor is estimated to be E th 0.6 ev. The observed dependency of the energy resolution on the photons energy is related to the change of the pulse fall time as a function of energy shown in Fig. 2.b. In a neighbourhood of this particular bias point the sensor parameters like α, β, and L 0 are changing quite rapidly 5, leading to a strong dependence of the τ f all on the signal amplitude and thus the energy. From Eq. 1 and the polynomial curve obtained to fit the experimental measurements of τ f all as a function of energy we derive the dashed curve shown in Fig. 2, which gives the expected energy resolution in presence of excess noise for our sensor. We used M = 3, P J0 = 6.5 pw and we assumed them to be constant for all the energies. The behaviour of the X-ray and baseline resolution is qualitatively explained by Eq. 1. The discrepancy between the measured baseline resolution and the calculated resolution is of only about 15%. This could be due to the thermal fluctuation noise (not include in the estimated de due to the presence of a dangling heat capacitance thermally decoupled from the TES 5. The X-ray energy resolution is about 20% worse than the baseline resolution. This may indicate that the applied matched filter is not optimal due to the nonstationary property of the noise. In that case one would expect however the difference to be larger at higher energy. Drifts due to fluctuations of the bath temperature or magnetic field could also explain the discrepancy. Fig. 3 shows the energy distribution at 250 ev for a count-rate as large as 500 photons per second. When large photon fluxes are applied to the calorimeter

5 500 counts/bin 400 300 200 countrate 500 c/s pileup rejection 35% de=1.72± 0.02 ev χ 2 = 0.9 100 0 240 245 250 255 260 energy [ev] Fig. 3 Energy spectra for the optimal bias point and photon flux of about 500 photons/sec. We rejected about 30% of events due to pile-up a slightly worse energy resolution is observed. However, as shown in the figure, for a radiation flux as large as 500 photons/sec we could still measure an energy resolution of 1.78±0.02 ev. To produce the spectra we rejected about 30% of events due to pile-up. The energy degradation could be due to a non perfect pile-up rejection or non-linear effects in the detector caused by the large number of photons reaching the microcalorimeter. The excess energy counts observed in the low energy side of the spectrum are due to photons not directly absorbed in the microcalorimeter absorber. This is consequence of the fact that the collimator opening is slightly larger than the absorber size. The data analysis for high fluxes is still in progress. The complete results will be presented in a future paper. The dependency of the photon energy resolution on the TES bias point and magnetic field is shown in Fig. 4 for an energy of 250 ev. The best energy resolution is observed for R/R N 0.46 at zero perpendicular magnetic field B in the TES. We observed a degradation of the energy resolution of about 20% from the optimum when the TES is biased between 20% and 60% of R N. This is consistent with the results reported by Y.Takei et al. 5 on this sensor, where it is shown that the responsivity scales accordingly with the noise in this bias region. When a magnetic filed is applied the energy resolution becomes worse due to a lower thermometer superconducting transition steepness α. For a magnetic field as large as B =±200 mg the energy resolution becomes worse of about 50%. 4 Conclusions We presented the response and energy resolution measurements of a single pixel TES microcalorimeter operating in an ADR performed at the beam-line in the PTB radiometry laboratory at the electron storage ring BESSY II in the range from 200 to 1800 ev. At E = 250 ev we measured an energy resolution of 1.52±0.03 ev at the best bias point corresponding to a TES resistance R/R N = 0.46, for zero perpendicular magnetic field and for a count rate of 50 photons/sec. The energy resolution was found to be dependent on the photon energy and is related

6 energy resolution FWHM [ev] 4 3.5 3 2.5 2 1.5 B = -57 mgauss B 1 = 0 mgauss B = 200 mgauss 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 R/R n Fig. 4 X-ray energy resolution for photons of energy E = 250eV as a function of TES dynamic resistance R and the perpendicular magnetic field. to the change of the pulses fall time. A small degradation of the energy resolution was observed for large count-rate. With 500 photons/sec reaching the detector an energy resolution of 1.78±0.02 ev at 250 ev was measured with a pile-up rejection of 30%. Further we found a weak dependency of the energy resolution on the detector working point consistent with the responsivity and noise measurement reported in Ref. 5. The data analysis is still in progress. We aim to fully investigate crucial detector issues like the calibration of the energy scale, non linearity, energy resolution retrieval from pile-up events and large signal analysis. Acknowledgements We are grateful to Marcos Bavdaz and Didier Martin from ESA for giving us the possibility to use the beam-line at PTB-BESSY and to people from the PTB radiometry laboratory for their help during the measurements. We thank Paul Lowes and Arjan de Klein for their precious technical help and Chris Whitford for providing the IR/UV-filters. This work is financially supported by the Dutch Organization for Scientific Research (NWO). References 1. ESA, Cosmic Vision Proposal, 2007 2. ESA Cosmic Vision Proposal, 2007 3. GSFC, NASA, http://constellation.gsfc.nasa.gov 4. K.D. Irwin, et al,appl. Phys. Lett. 66, 1998, (1995) 5. Y. Takei, et al,journal of Low temperature Physics in this volume 6. H.F.C. Hoevers, et al, Journal of Low temperature Physics in this volume 7. P.A. de Korte, et al, Journal of Low temperature Physics in this volume 8. J.N. Ullom, et al, Appl. Phys. Lett. 87, 194103, (2005) 9. G. Ulm, et al., SPIE 3444, 610, (1998)