MUON LIFETIME MEASUREMENT EXPERIMENT

Similar documents
Measurement of Mean μ-lifetime

MUON LIFETIME MEASUREMENT

MESUREMENT OF MUON LIFETIME USING COSMIC MUON STOPPED IN PLASTIC SCINTILLATOR DETECTOR.

MEASURING THE LIFETIME OF THE MUON

Study of the Scintillation Detector Efficiency and Muon Flux

Measuring Cosmic Ray Muon Decay Constant and Flux

Measurement of Muon Lifetime

John Ellison University of California, Riverside. Quarknet 2008 at UCR

Radioactivity and Ionizing Radiation

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

Cosmic Ray Muon Detection

Muon Detector. PMT coupled Plastic Scintillator for Cosmic Muons Detection. Lodovico Lappetito. RilevatoreMuoni_ENG - 18/11/2015 Pag.

SiPM & Plastic Scintillator

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Cosmic rays and the muon lifetime 1

Particle Energy Loss in Matter

Scintillation Detector

Measuring the Muon Lifetime

Cosmic Ray Muons Research Project

Y2 Neutrino Physics (spring term 2017)

EEE4106Z Radiation Interactions & Detection

Review of Particle Properties: ( ). See the review section on Cosmic Rays under Astrophysics and Cosmology.

Chapter 4 Scintillation Detectors

Nuclear Physics and Astrophysics

Overview: In this experiment we will study the decay of a radioactive nucleus, Cesium. Figure 1: The Decay Modes of Cesium 137

Particle Energy Loss in Matter

Analysis of γ spectrum

Rice University Physics 332 LIFETIME OF THE MUON I. INTRODUCTION...2! II. MEASUREMENT PROCEDURES...3! III. ANALYSIS PROCEDURES...7!

Cosmic Rays Detector. Use of Coincidence Detector for Measures of Cosmic Rays. Lodovico Lappetito. RivelatoreRaggiCosmici_ENG - 6/22/2015 Page 1

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Physics Quarknet/Service Learning

DETECTORS. I. Charged Particle Detectors

energy loss Ionization + excitation of atomic energy levels Mean energy loss rate de /dx proportional to (electric charge) 2 of incident particle

E. K. A. ADVANCED PHYSICS LABORATORY STATISTICS OF COUNTING WITH A GEIGER COUNTER ARTIFICIAL RADIOACTIVITY

Radionuclide Imaging MII Detection of Nuclear Emission

Investigation of Combined Positive and Negative Muon Decay in a Scintillator

COSMIC RAY MUONS. v4.1 Last Revision: R. A. Schumacher, May 2017

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

- ~200 times heavier than the e GeV µ travels on average. - does not interact strongly. - does emit bremsstrahlung in

Overview: In this experiment we study the decay of a radioactive nucleus, Cesium 137. Figure 1: The Decay Modes of Cesium 137

Muon Physics. T.E. Coan and J. Ye. v

BETA-RAY SPECTROMETER

General Physics (PHY 2140)

Particle Physics Homework Assignment 3

Cherenkov Detector. Cosmic Rays Cherenkov Detector. Lodovico Lappetito. CherenkovDetector_ENG - 28/04/2016 Pag. 1

Radiation (Particle) Detection and Measurement

Scintillation Detectors

Particles and Waves Final Revision Exam Questions Part 1

Measuring the lifetime of cosmic ray muons

Cosmic Rays: A Way to Introduce Modern Physics Concepts. Steve Schnetzer

Scintillation Detectors

ABSORPTION OF BETA AND GAMMA RADIATION

CfE Higher Physics. Particles and Waves

Cosmic Drizzle. Thomas Coan. What s a cosmic ray (note the s ) Origin, propagation and lifetime of CRs. Digression 1: facts about your mother

SCINTILLATION DETECTORS AND PM TUBES

FLAP P9.2 Radioactive decay COPYRIGHT 1998 THE OPEN UNIVERSITY S570 V1.1

Lecture 3. lecture slides are at:

Chapter NP-4. Nuclear Physics. Particle Behavior/ Gamma Interactions TABLE OF CONTENTS INTRODUCTION OBJECTIVES 1.0 IONIZATION

Appendix A2. Particle Accelerators and Detectors The Large Hadron Collider (LHC) in Geneva, Switzerland on the Border of France.

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Neutrinos & Weak Interactions

Exam Results. Force between charges. Electric field lines. Other particles and fields

NUCLEAR AND PARTICLE PHYSICS (PH242) PARTICLE PHYSICS

Radioactivity. The Nobel Prize in Physics 1903 for their work on radioactivity. Henri Becquerel Pierre Curie Marie Curie


Neutrino Physics. Neutron Detector in the Aberdeen Tunnel Underground Laboratory. The Daya Bay Experiment. Significance of θ 13

Chapter 3 Radioactivity

2007 Fall Nuc Med Physics Lectures

Radioactivity INTRODUCTION. Natural Radiation in the Background. Radioactive Decay

Atmospheric Neutrinos and Neutrino Oscillations

Chapter 30 Nuclear Physics and Radioactivity

1. (a) An ion of plutonium Pu has an overall charge of C. (iii) electrons... (3) (2) (Total 5 marks)

Particle Detectors. How to See the Invisible

Radioactivity. PC1144 Physics IV. 1 Objectives. 2 Equipment List. 3 Theory

LAB 4: Gamma-ray coincidence spectrometry (2018)

Modern Physics Laboratory Beta Spectroscopy Experiment

UGC ACADEMY LEADING INSTITUE FOR CSIR-JRF/NET, GATE & JAM PHYSICAL SCIENCE TEST SERIES # 4. Atomic, Solid State & Nuclear + Particle

arxiv: v1 [physics.ins-det] 3 Feb 2011

Neutron pulse height analysis (R405n)

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Sources of Radiation

NOTE: The Flatpak version has the same pinouts (Connection Diagram) as the Dual In-Line Package. *MR for LS160A and LS161A *SR for LS162A and LS163A

Radioactivity APPARATUS INTRODUCTION PROCEDURE

Lab 3 Revisited. Zener diodes IAP 2008 Lecture 4 1

CHARGED PARTICLE INTERACTIONS

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

EQUIPMENT Beta spectrometer, vacuum pump, Cs-137 source, Geiger-Muller (G-M) tube, scalar

Alpha-particle Stopping Powers in Air and Argon

Neutron Detection. n interactions with matter n detection High/low energy n detectors

Synthesis of plastic scintillator. Ildefonso León Monzón Universidad Autónoma de Sinaloa

Strand J. Atomic Structure. Unit 2. Radioactivity. Text

Flux Variation of Cosmic Muons

EXPERIMENT 11: NUCLEAR RADIATION

Objectives: Atomic Structure: The Basics

Muon Telescope at BEO Moussala *

Neutrino Helicity Measurement

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

Transcription:

MUON LIFETIME MEASUREMENT EXPERIMENT Animesh chatterjee, Abstract: INO Graduate school, TIFR In this experiment we are measuring the time taken by a muon to decay into an electron. At first when cosmic ray muon passes through the scintillator, it produces light signal & when this light signal passes through the PMT, PMT produces electrical signal. This signal is then passes through a time measuring circuit, which starts counting in the counter. When muon decays into electron, it produces another signal, which stops the counting of the counter. So by counting no. of the counts (bits), we can measures the mean life time of muon. Introduction: Muons are the fundamental particles and belong to the lepton family. These fundamental particles are heavier than electrons, with mass of about 105.7Mev/c 2, carry one unit of fundamental charge and they are unstable. Muons participate in electromagnetic and weak interactions and are not subjected to strong interactions. The muons while passing through the matter, can disappear in anyone of the two ways. Either by capturing the nucleus in which case a neutron and neutrino are emitted or by spontaneous decay in which electron along with neutrino, antineutrino pair are produced. µ e +v e+νμ μ + e + +νe+v μ These are electroweak decays as, two of the decay products are neutrinos. Production of cosmic ray muon: The particles arriving from space are known as primary cosmic rays and the particles created in the collisions are known as secondary cosmic ray. Most of the primary cosmic rays consist in upper atmosphere and interacts with the atmospheric nuclei such as nitrogen or oxygen producing secondary particles. These collisions produce mostly neutral

and charged pions. These pions with a mass 273 times that of the electron are not stable and have a lifetime of about 10-8 secs. They decay into muons exponentially similar to radioactive nuclei. Each neutral pion decay into a pair of gamma rays and the charged pions decay into a charged muon and a muon neutrino.the sequence of events is illustrated in fig.1. Fig 1. A typical interaction between a cosmic ray proton and an atmospheric nucleus. The particles created in this interaction are mostly short lived. They cannot reach sea-level, but we can find muon at sea level. The total secondary flux at sea level is 1cm - 2 min -1. Roughly 75% consists of positive and negative muons and only 25% electrons and positrons. Principle of muon decay: Muons have a lifetime of 2.2 µs when measured in its rest frame. Given this muon lifetime and assuming a velocity close to that of light, we would find that muons could only travel a distance of about 650 m before they decay. Hence classically, they could not reach the Earth from the upper atmosphere where they are produced. However, experiments show that a large number of muons do reach the Earth. This is due to the relativistic time dilation. As we are measuring the time from the lab frame, so the time actually measured from lab frame is

t = t 1 v2 c 2 1 2 = γt Where t is the time measured in the rest frame of the muon and t is the time in the lab frame, v is the velocity of the muon. Relative to an observer on Earth, the muons have a lifetime equal to γt, where t = 2.2µs is the lifetime in a frame of reference travelling with the muons. For example, for v = 0.99c, γt = 15.6µs. Hence, the average distance travelled as measured by an observer on Earth is 4678.62m. In this experiment muons are stopped by the scintillator and then it decays to electron. If N 0 be the initial muon coming to the scintillator (say at time t=0) then at any time t, decay is followed by this law N = N O e t τ Where τ is the mean life time of the muon. The average muon life time is then determined by fitting exp (-t/τ) to the distribution of the time intervals between entry of muon stopped in plastic scintillator and their subsequent decay and determining the value of τ after correcting for the background. Experimental arrangement: Fig 2. Block Diagram of Experimental Arrangement

The requirement for this circuit are 1. Plastic Scintillator 2. Photomultiplier tube(pmt) 3. Time measuring circuit 1) Plastic Scintillator: The dimension of the scintillator box used here is 24cm*24cm*14.5cm. A scintillator is a transparent material containing molecules which are excited by the passage of charged particles. When a charged particle passes through the scintillator, it lose some of its kinetic energy by ionization and excites the atomic electrons of the molecules. When this electrons deexcites, it produces photon. Here when muon passes through the scintillator then de excitation of the molecules produces radiation near the blue and below UV region of electromagnetic spectrum. The efficiency of the Scintillator depends on the number of charged particle entering to the scintillator to the number of photons created. The scintillator wrapped with black paper to avoid the light coming from outside. Here we have used plastic scintillator. 2) Photomultiplier Tube: It consists of a glass vacuum tube with a photocathode, several dynodes and an anode.the plastic scintillator is directly coupled to the PMT, when light signal coming from the scintillator falls on the photocathode, it emits electrons by the principle of photoelectric effect. These electrons are now being multiplied by the method of secondary emission by dynodes. Finally the electrons reach the anode where the accumulation of charge results in a sharp current pulse thus producing a strong electrical signal at the output. The Quantum efficiency of the PMT is ratio of photons incident and the no. of electrons collected by the anode. Time measuring circuit: Shape of the PMT Pulse: When muon passes through the scintillator, it produces light signals which are fed to the PMT to produce negative pulses at the output. A pair of such pulses are shown in fig below

Fig 3. PMT pulse IC Details: IC Name Description LM 360(8 pins) Comparator 74 LS74(14pins) Dual edge-triggered FlipFlop 74LS161(16pins) 4 bit synchronous operation 74LS541(20pins) Octal Buffer 74LS11(14pins) AND Gate 74LS04(14pins) NOT Gate 7805(3pins) Positive voltage Regulator 7905(3pins) Negative voltage Regulator DB103(4pins) Bridge Rectifier Circuit Operation: At first reset switch is pressed before starting the experiment to ensure that all F/F's are in clear states through the AND gate (IC 74LS11) and also the counters. Hence initially both flip flops are in a cleared state, waiting for a start pulse from the PMT signifying the entry of a muon. In clear states the Q o/p of the F/F's are set to low while Q is set to high. The D of the first F/F is set to high and the clock of the second F/F is high. However the o/p of the second F/F does not change state because of the clear signal. The negative analog pulse coming from the PMT enters to the Comparator LM360.Now noise signal coming from the PMT can also give output voltage of the comparator, to avoid these noise signal a threshold voltage(-42mv here) is applied to the non-inverting terminal of the opamp. when the PMT signal at the inverting terminal is greater than the threshold voltage, then we get a positive digital pulse(ttl) output from the comparator, because we are applying negative voltage at the inverting terminal.

This digital pulse is the clock of the 1 st FF. Initially in the cleared state of the FF Q=LOW & Q =HIGH,so D input of the FF is is high.thus when digital pulse comes from the comparator to the clock,then Q=HIGH & Q =LOW.This Q goes to the ENT of the 1 st counter and starts the counting with the frequency of the clock pulse,which is 10MHz here. Now we consider two cases 1 st when muon decays to electron and second when muon doesnot decay. 1 ST Muon Decays to electron: when muon decays to electron,a second pulse immediately comes from the PMT and passes to the comparator, so we get a digital pulse Fig4-Time measuring circuit

which comes to the 1 st FF. This time D input of its is LOW so this time Q=LOW & Q =HIGH.So the output of the 1 st FF Stops the counter. The Q output of 1 st FF Is the clock of the 2 nd FF. Thus Q of the 2 nd FF is LOW. It clears the 1 st FF and counters. The Q output of the 2 nd FF is buffered and the signal is sent to the BUSY pin of the PC parallel port. When PC receives the BUSY signal as low, then DATA-STROBE line of the BUFFER changes to LOW immediately. The Data BUFFER passes the count to the PC. After the PC has read the data, DATA_STROBE is taken high and the RESET line is pulled low for a µs. This RESET signal clears the F/F's and counter ready for the next signal from the PMT. The interfacing program writes the total number of counts, the time and date of written file. When muon doesn t decay: If the muon passes through the scintillator without decaying, the USB counter reaches 255, i.e., a second pulse is not received within 25.5µs, and its RCO pin goes high. This is inverted through a NOT gate(ic 74LS04) to clear the counters and F/F s, to wait for the next pulse from the PMT. Data analysis:- The data is saved in a file, where different time intervals for each muon decay i.e. the time lag between the start event and stop event are in a column. The sampled data is not free from the background events. The detector doesn t know if the events produced are from the stopping of muon and its decay or from starting from some other radioactive source or light leakage and stopping from another of the same. The background events which are produced due to start from one muon and stop from another one will be very small as the flux reaching down at sea level is very small when compared to the 25.5μs window we have put in for counting. If the background for the data is assumed to be constant over a period of time then N = N 0 e t τ + b

Fig5:- Plot of number of events in log scale with background Fig6:-Plot of number. of events vs time

The value of the decay time of muon is Fermi Coupling Constant: τ = (2.19±.2)µs The value of N 0 = (855.9±9.8) b = (9.54±0.27) The Fermi coupling constant plays a key role in all precision tests of electroweak standard model. It is obtained from the muon lifetime ( τ ) via a calculation in the Fermi model as: τ =192 π 3 / G F 2 m µ 5 The value of G F obtained for the above value of τ is, where m µ is taken as 105MeV. G F = (192π 3 / τ m µ 5 ) 1/2 G F = 1.16533x10-5 Gev -2 REFERENCES: 1) Glenn F. Knoll, Radiation Detection And Measurement. 2) IC datasheets of Fairchild Semiconductor, Motorola, ST Microelectronicsand National Semiconductor 3) W.R.Leo, Techniques For Nuclear And Particle Physics Experiments. 4) David Griffiths, INTRODUCTION TO ELEMENTARY PARTICLES. 5) Dr. F.Muheim, Muon Lifetime Measurement 6) J.Santos, J.Augusto, A.Gomes, L.Gurriana, N.Laurenco, A.Maio,C.Marques, J.Silva, The CRESCRE Muon's Lifetime Experiment.

Circuit Component:- APPENDIX I. Discrimenator(LM360):- Discrimenator is basically A/D Converter or it is also called voltage comparator.an OP-AMP can be used as a Discrimenator by operating it in the open loop condition and applying the two voltages to be compared to the inverting and noninverting inputs.the voltage at the inverting terminal is negative so the output will be positive voltage. Here if the voltage at the inverting terminal(2) is slightly greater than the threshold voltage at the noninverting terminal,which is -30mv,then output switch to the saturation voltage which is 5 volt here

II. D type Flip Flop(74LS74):- The 74LS74 dual edge-triggered flip flop utilizes Schottky TTL circuitry to produce high speed D type flip flop.each lsflip-flops has individual clear and set inputs and also complementary Q and Q outputs. Information on the data input is transferred to the Q output on sthelow-to-high transition of the clock pulse. When the clock input is at either the HIGH or LOW level,the D input signal has no effect.(detail circuit is in Appendix). III. TRIPLE 3-INPUT AND GATE(74LS11):-

IV. Synchronous 4-Bit Binary Counter(74LS161): The 74LS161 are 4-bit synchronous counter. Synchronous operation is provided by having all flip flops clocked simultaneously so that the outputs change coincident with each other. Operating Ranges Symbol parameter Min Type Max Unit Vcc TA IOH IOL Supply 4.75 5.25 V Voltage 5 Operating Ambient 0 2.5 70 Temperature oc range Output current 0.4 ma High Output current Low 8 ma