Fabry-Perot Measurement of Aeronomic Winds and Temperatures

Similar documents
Astronomy 203 practice final examination

Fabry-Perot Interferometer for atmospheric monitoring useful for EAS detection E.Fokitis 1, K. Patrinos 1, Z. Nikitaki 1

Phys102 Lecture Diffraction of Light

Where are the Fringes? (in a real system) Div. of Amplitude - Wedged Plates. Fringe Localisation Double Slit. Fringe Localisation Grating

Neutral Winds in the Upper Atmosphere. Qian Wu National Center for Atmospheric Research

NTUA. A. Georgakopoulou. A. Papayannis1, A. Aravantinos2 NATIONAL TECHNICAL UNIVERSITY OF ATHENS TECHNOLOGICAL EDUCATIONAL INSTIDUTION OF ATHENS SIENA

Atomic Spectra HISTORY AND THEORY

Lecture 28. Aerosol Lidar (4) HSRL for Aerosol Measurements

Measurements of Hot Air in Alaska

Edward S. Rogers Sr. Department of Electrical and Computer Engineering. ECE318S Fundamentals of Optics. Final Exam. April 16, 2007.

Overview: Astronomical Spectroscopy

September 14, Monday 4. Tools for Solar Observations-II

The science of light. P. Ewart

AS 101: Day Lab #2 Summer Spectroscopy

Diffraction Gratings, Atomic Spectra. Prof. Shawhan (substituting for Prof. Hall) November 14, 2016

Let us consider a typical Michelson interferometer, where a broadband source is used for illumination (Fig. 1a).

Astronomy. Optics and Telescopes

Lecture 18. Temperature Lidar (7) Rayleigh Doppler Technique

Fabry-Perot Interferometers

Chapter 35 Diffraction and Polarization. Copyright 2009 Pearson Education, Inc.

Lecture 11: Doppler wind lidar

Some Topics in Optics

Edward S. Rogers Sr. Department of Electrical and Computer Engineering. ECE426F Optical Engineering. Final Exam. Dec. 17, 2003.

Lecture 7: Optical Spectroscopy. Astrophysical Spectroscopy. Broadband Filters. Fabry-Perot Filters. Interference Filters. Prism Spectrograph

Brightness Calibration of Optical Spectrographs

10. Wavelength measurement using prism spectroscopy

Chapter 35 Diffraction and Polarization

THE ZEEMAN EFFECT PHYSICS 359E

THE DIFFRACTION GRATING SPECTROMETER

Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009

Lecture 20. Wind Lidar (2) Vector Wind Determination

Experiment O-2. The Michelson Interferometer

Interference. Part-2. Gambar: Museum Victoria Australia

Interferometers. PART 1: Michelson Interferometer The Michelson interferometer is one of the most useful of all optical instru

High-Resolution. Transmission. Electron Microscopy

HMI Filter Calibration

Optical/NIR Spectroscopy A3130. John Wilson Univ of Virginia

Chapter 8 Optical Interferometry

DAY LABORATORY EXERCISE: SPECTROSCOPY

Atmospheric Remote Sensing in the Terahertz Region

PARTICLES AND WAVES CHAPTER 29 CONCEPTUAL QUESTIONS

Electricity & Optics

Measurements in Optics for Civil Engineers

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 FRAUNHOFER DIFFRACTION

High Performance Observation from Nanosats. *Utah State University

Atomic emission spectra experiment

tip conducting surface

INTERFEROMETERS. There are 4 principal types of measurements that can be made with this type of interferometer.

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

Experiment 3 1. The Michelson Interferometer and the He- Ne Laser Physics 2150 Experiment No. 3 University of Colorado

Advanced Spectroscopy Laboratory

C. Anderson 1, Conde M. 1, McHarg, M. 2, Nicolls, M. 3

MANIPAL INSTITUTE OF TECHNOLOGY

DISPERSION OF A GLASS PRISM

The Anomalous Zeeman Splitting of the Sodium 3P States

Astronomical frequency comb for calibration of low and medium resolution spectrographs

N M O 0 1 Q P. (26.2)

Metamaterials & Plasmonics

Wavelength Frequency Measurements

Experiment #5: Cauchy s Formula

NORTHERN ILLINOIS UNIVERSITY PHYSICS DEPARTMENT. Physics 211 E&M and Quantum Physics Spring Lab #9: Diffraction Spectroscopy

Lecture 26. Wind Lidar (4) Direct Detection Doppler Lidar

Metrology and Sensing

How does your eye form an Refraction

PRINCIPLES OF PHYSICAL OPTICS

Metrology and Sensing

Spectroscopic Instruments

Diffraction gratings. B.Tech-I

Zeeman Effect - Lab exercises 24

To determine the wavelengths of light emitted by a mercury vapour lamp by using a diffraction grating.

THE MICHELSON INTERFEROMETER Intermediate ( first part) to Advanced (latter parts)

EXPERIMENT 5:Determination of the refractive index (µ) of the material of a prism using sprectometer

Light as Wave Motion p. 1 Huygens' Ideas p. 2 Newton's Ideas p. 8 Complex Numbers p. 10 Simple Harmonic Motion p. 11 Polarized Waves in a Stretched

Absorption and scattering

JRE Group of Institutions ASSIGNMENT # 1 Special Theory of Relativity

Physics I : Oscillations and Waves Prof. S. Bharadwaj Department of Physics and Meteorology Indian Institute of Technology, Kharagpur

Lecture PowerPoints. Chapter 24 Physics: Principles with Applications, 7 th edition Giancoli

Department of Physics, Colorado State University PH 425 Advanced Physics Laboratory The Zeeman Effect. 1 Introduction. 2 Origin of the Zeeman Effect

Science Lab I Properties of Light

: Imaging Systems Laboratory II. Laboratory 6: The Polarization of Light April 16 & 18, 2002

Lecture 33. Aerosol Lidar (2)

Chapter 4 Spectroscopy

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

The Emission Spectra of Light

Optical/IR Observational Astronomy Spectroscopy. David Buckley, SALT

n(λ) = c/v(λ). Figure 1: Dispersion curves for some common optical glass types.

The Spectrophotometer and Atomic Spectra of Hydrogen Physics 246

PAPER 338 OPTICAL AND INFRARED ASTRONOMICAL TELESCOPES AND INSTRUMENTS

34. Even more Interference Effects

Transmission Electron Microscopy

Week 7: Interference

Laboratory #29: Spectrometer

Dept. of Physics, MIT Manipal 1

Diagnósticos em Plasmas

Atomic and nuclear physics

University of Cyprus. Reflectance and Diffuse Spectroscopy

Laser Types Two main types depending on time operation Continuous Wave (CW) Pulsed operation Pulsed is easier, CW more useful

Reflection = EM strikes a boundary between two media differing in η and bounces back

ATOMIC SPECTRA. To identify elements through their emission spectra. Apparatus: spectrometer, spectral tubes, power supply, incandescent lamp.

LC circuit: Energy stored. This lecture reviews some but not all of the material that will be on the final exam that covers in Chapters

Transcription:

FPI T 2014 Introduction section Page: 1 Fabry-Perot Measurement of Aeronomic Winds and Temperatures Mark Conde University of Alaska Fairbanks This talk is a tutorial on the technique of using Fabry-Perot spectrometers to measure neutral winds and neutral temperatures in Earth s uppper atmosphere.

FPI T 2014 Introduction section Page: 2

FPI T 2014 Remote Sensing Doppler Technique section Page: 3 Passive Doppler Wind & Temperature Measurement Airglow or auroral photons appear Doppler shifted from the ground because they are emitted by atoms and molecules that move with the thermospheric wind. 1 Subject to some assumptions regarding the uniformity of the wind field. Alternatively, line-of-sight components may be combined from several geographically dispersed observing sites.

FPI T 2014 Remote Sensing Doppler Technique section Page: 3 Passive Doppler Wind & Temperature Measurement Airglow or auroral photons appear Doppler shifted from the ground because they are emitted by atoms and molecules that move with the thermospheric wind. While the Doppler shift only measures the line-of-sight wind component, the complete wind vector can be estimated by viewing in several directions. 1 1 Subject to some assumptions regarding the uniformity of the wind field. Alternatively, line-of-sight components may be combined from several geographically dispersed observing sites.

FPI T 2014 Remote Sensing Doppler Technique section Page: 3 Passive Doppler Wind & Temperature Measurement Airglow or auroral photons appear Doppler shifted from the ground because they are emitted by atoms and molecules that move with the thermospheric wind. While the Doppler shift only measures the line-of-sight wind component, the complete wind vector can be estimated by viewing in several directions. 1 Further, temperatures may be inferred from the width of the Doppler spectrum. 1 Subject to some assumptions regarding the uniformity of the wind field. Alternatively, line-of-sight components may be combined from several geographically dispersed observing sites.

FPI T 2014 Remote Sensing Doppler Technique Required Resolution section Page: 4 The 1 e half-width of an unstructured spectral line s Doppler broadening function is related to kinetic temperature by w(t ) = λ 0 2kT mc 2 (1)

FPI T 2014 Remote Sensing Doppler Technique Required Resolution section Page: 4 The 1 e half-width of an unstructured spectral line s Doppler broadening function is related to kinetic temperature by w(t ) = λ 0 2kT mc 2 (1) For the 630nm emission from atomic oxygen at a temperature of (say) 800K, this is 2 1.38 10 w = 630nm 23 JK 1 800K 16u (3 10 8 ms 1 ) 2

FPI T 2014 Remote Sensing Doppler Technique Required Resolution section Page: 4 The 1 e half-width of an unstructured spectral line s Doppler broadening function is related to kinetic temperature by w(t ) = λ 0 2kT mc 2 (1) For the 630nm emission from atomic oxygen at a temperature of (say) 800K, this is 2 1.38 10 w = 630nm 23 JK 1 800K 16u (3 10 8 ms 1 ) 2 = 1.9 10 3 nm [=1.9 picometers]

FPI T 2014 Remote Sensing Doppler Technique Required Resolution section Page: 4 The 1 e half-width of an unstructured spectral line s Doppler broadening function is related to kinetic temperature by w(t ) = λ 0 2kT mc 2 (1) For the 630nm emission from atomic oxygen at a temperature of (say) 800K, this is 2 1.38 10 w = 630nm 23 JK 1 800K 16u (3 10 8 ms 1 ) 2 = 1.9 10 3 nm [=1.9 picometers] The full width at half maximum of the Doppler spectrum is then W = w 2 ln2 (2) = 3.2pm

FPI T 2014 Remote Sensing Doppler Technique Required Resolution section Page: 4 The 1 e half-width of an unstructured spectral line s Doppler broadening function is related to kinetic temperature by w(t ) = λ 0 2kT mc 2 (1) For the 630nm emission from atomic oxygen at a temperature of (say) 800K, this is 2 1.38 10 w = 630nm 23 JK 1 800K 16u (3 10 8 ms 1 ) 2 = 1.9 10 3 nm [=1.9 picometers] The full width at half maximum of the Doppler spectrum is then W = w 2 ln2 (2) = 3.2pm To resolve such a width, we d like a spectrometer with a comparable bandwidth, which corresponds to a resolving power of R = λ λ = 630nm 3.2pm 200,000

FPI T 2014 Remote Sensing Doppler Technique Required Stability section Page: 5 Thermospheric bulk wind speeds (order 100ms 1 ) are usually less than the thermal speeds of individual particles (order 1kms 1 ). This means a spectral line s Doppler shift will normally be substantially less than its Doppler width.

FPI T 2014 Remote Sensing Doppler Technique Required Stability section Page: 5 Thermospheric bulk wind speeds (order 100ms 1 ) are usually less than the thermal speeds of individual particles (order 1kms 1 ). This means a spectral line s Doppler shift will normally be substantially less than its Doppler width. Fortunately, a good spectrometer can resolve shifts in a spectral line that are much less than its instrumental bandwidth. Nevertheless, any shift must be calculated relative to some reference that must be known absolutely and must remain stable with time.

FPI T 2014 Remote Sensing Doppler Technique Required Stability section Page: 5 Thermospheric bulk wind speeds (order 100ms 1 ) are usually less than the thermal speeds of individual particles (order 1kms 1 ). This means a spectral line s Doppler shift will normally be substantially less than its Doppler width. Fortunately, a good spectrometer can resolve shifts in a spectral line that are much less than its instrumental bandwidth. Nevertheless, any shift must be calculated relative to some reference that must be known absolutely and must remain stable with time. For speeds c, the wavelength shift due to a line of sight speed of v is given by λ = λ 0 v c (3)

FPI T 2014 Remote Sensing Doppler Technique Required Stability section Page: 5 Thermospheric bulk wind speeds (order 100ms 1 ) are usually less than the thermal speeds of individual particles (order 1kms 1 ). This means a spectral line s Doppler shift will normally be substantially less than its Doppler width. Fortunately, a good spectrometer can resolve shifts in a spectral line that are much less than its instrumental bandwidth. Nevertheless, any shift must be calculated relative to some reference that must be known absolutely and must remain stable with time. For speeds c, the wavelength shift due to a line of sight speed of v is given by λ = λ 0 v c (3) We d like to measure winds to an accuracy of 2ms 1 which, for observations at λ = 630nm, requires that our spectrometer s wavelength reference is known and stable to λ 630nm 2ms 1 3 10 8 = 4.2fm ms 1

FPI T 2014 Remote Sensing Doppler Technique Required Stability section Page: 5 Thermospheric bulk wind speeds (order 100ms 1 ) are usually less than the thermal speeds of individual particles (order 1kms 1 ). This means a spectral line s Doppler shift will normally be substantially less than its Doppler width. Fortunately, a good spectrometer can resolve shifts in a spectral line that are much less than its instrumental bandwidth. Nevertheless, any shift must be calculated relative to some reference that must be known absolutely and must remain stable with time. For speeds c, the wavelength shift due to a line of sight speed of v is given by λ = λ 0 v c (3) We d like to measure winds to an accuracy of 2ms 1 which, for observations at λ = 630nm, requires that our spectrometer s wavelength reference is known and stable to λ 630nm 2ms 1 3 10 8 = 4.2fm ms 1 Key Concept: Instrumental Requirements Thus, Doppler spectral measurement of thermospheric wind and temperature requires an instrument with a resolving power of R 200,000 and a wavelength stability of around 5 femtometers!

FPI T 2014 Remote Sensing Doppler Technique Required Stability section Page: 5 Thermospheric bulk wind speeds (order 100ms 1 ) are usually less than the thermal speeds of individual particles (order 1kms 1 ). This means a spectral line s Doppler shift will normally be substantially less than its Doppler width. Fortunately, a good spectrometer can resolve shifts in a spectral line that are much less than its instrumental bandwidth. Nevertheless, any shift must be calculated relative to some reference that must be known absolutely and must remain stable with time. For speeds c, the wavelength shift due to a line of sight speed of v is given by λ = λ 0 v c (3) We d like to measure winds to an accuracy of 2ms 1 which, for observations at λ = 630nm, requires that our spectrometer s wavelength reference is known and stable to λ 630nm 2ms 1 3 10 8 = 4.2fm ms 1 Key Concept: Instrumental Requirements Thus, Doppler spectral measurement of thermospheric wind and temperature requires an instrument with a resolving power of R 200,000 and a wavelength stability of around 5 femtometers! Of the devices that could meet these specifications, Fabry-Perot spectrometers achieve the highest optical throughput.

FPI T 2014 Remote Sensing Doppler Technique Suitable Emission Lines section Page: 6 Useful emissions for Fabry-Perot measurements of wind and temperature include: Oxygen Red Line: From atomic oxygen at a wavelength 630.0nm. Volume emission rate maximizes at a height of around 240km for airglow, or as low as 180km for aurora. Layer thickness spans many tens of kilometers.

FPI T 2014 Remote Sensing Doppler Technique Suitable Emission Lines section Page: 6 Useful emissions for Fabry-Perot measurements of wind and temperature include: Oxygen Red Line: From atomic oxygen at a wavelength 630.0nm. Volume emission rate maximizes at a height of around 240km for airglow, or as low as 180km for aurora. Layer thickness spans many tens of kilometers. Oxygen Green Line: This emission is from atomic oxygen at a wavelength 557.7nm. Volume emission rate maximizes at a height of around 97km for airglow, or anywhere in the range 95km to about 150km for aurora. Height variation in aurora is due to variable characteristc energy of the precipitating electrons, and can be a problem for wind & temperature retrieval.

FPI T 2014 Remote Sensing Doppler Technique Suitable Emission Lines section Page: 6 Useful emissions for Fabry-Perot measurements of wind and temperature include: Oxygen Red Line: From atomic oxygen at a wavelength 630.0nm. Volume emission rate maximizes at a height of around 240km for airglow, or as low as 180km for aurora. Layer thickness spans many tens of kilometers. Oxygen Green Line: This emission is from atomic oxygen at a wavelength 557.7nm. Volume emission rate maximizes at a height of around 97km for airglow, or anywhere in the range 95km to about 150km for aurora. Height variation in aurora is due to variable characteristc energy of the precipitating electrons, and can be a problem for wind & temperature retrieval. 732 nm O + : This emission from O + comes from the F-region and above. It is very weak, but potentially useful for measuring ion velocities, among other things. OH emissions: Various OH emission lines occur at around 840nm and are useful for measuring winds at around 87km. The emissions are relatively weak, and doublet spectral structure complicates wind & temperature retrievals. Twilight Sodium: Resonant scattering of sunlight from the mesospheric sodium layer at 90km altitude produces bright "D" doublet emission at 589.0nm and 589.6nm The layer must be sunlit, so the best data are obtained during twilight. Again, hyperfine doublet structure complicates wind & temperature retrievals.

FPI T 2014 Remote Sensing Measuring Spectra How to Measure Optical Spectra? section Page: 7 Question: Optical detectors only measure the intensity of light. So how (generically) do we resolve a spectrum?

FPI T 2014 Remote Sensing Measuring Spectra How to Measure Optical Spectra? section Page: 7 Question: Answer: Optical detectors only measure the intensity of light. So how (generically) do we resolve a spectrum?. To obtain a spectrum, we must build an instrument that restricts the detector to only accept light within a narrow wavelength "pass band". We then then record the resulting brightness as that pass band is tuned or scanned to different wavelengths.

FPI T 2014 Remote Sensing Measuring Spectra How to Measure Optical Spectra? section Page: 7 Question: Answer: Optical detectors only measure the intensity of light. So how (generically) do we resolve a spectrum?. To obtain a spectrum, we must build an instrument that restricts the detector to only accept light within a narrow wavelength "pass band". We then then record the resulting brightness as that pass band is tuned or scanned to different wavelengths.. The tuning can either be done by varying a single pass band over time, or by having multiple sensors spread out across a region where the pass band is dispersed spatially. The cartoon diagram below shows a prism spectrometer using the latter strategy. Slit Note: Ray paths in this region are not drawn accurately Red Lamp Helium lamp Prism Blue Spectrum Real world example Spectrum

FPI T 2014 Remote Sensing Measuring Spectra Example Recording a Solar Spectrum section Page: 8 This is an conceptual example of scanning a single pass band over time to record a spectrum. In this case I am using the solar spectrum near 630nm as an example of the source or input spectrum. Although it not obvious with the very narrow passband used here, the recorded spectrum is not the same as the source. The recorded spectrum is the convolution of the source spectrum with the instrumental pass band function.

FPI T 2014 Remote Sensing Measuring Spectra section Page: 9 Effect of Pass Band Width This is the same as the previos example, except the instrumental pass and is now much wider in wavelength. Note how the narrow spectral features now appear broader and less deep in the recorded spectrum. It is not possible to build a spectrometer with a pass band of zero width. (It would have zero transmission.) Instrumental broadening is inevitable. To calculate atmospheric temperature from recorded spectral widths, our analysis procedures must account for this broadening (Using either deconvolution or forward modeling.)

FPI T 2014 Fabry-Perot Spectrometers Etalons Fabry-Perot Etalon section Page: 10 A Fabry-Perot etalon is comprised of two glass plates that are flat and parallel to λ /30 or better, whose inner surfaces are coated to achieve a reflectance roughly in the range 0.75 to 0.95. The plate coatings cause multiple reflections, which interfere so that only certain wavelengths are transmitted. (All others are reflected). The etalon acts as a highly selective spectral filter. E 0 E 0 r E 0 tr't' E 0 tr' 3 t' E 0 tr' 5 t' E 0 tr' 7 t' E 0 t E 0 tr' 2 E 0 tr' 4 E 0 tr' 6 d Index=η E 0 tr' E 0 tr' 3 E 0 tr' 5 E 0 tr' 7 E 0 tt' E 0 tt'r' 2 E 0 tt'r' 4 E 0 tt'r' 6

FPI T 2014 Fabry-Perot Spectrometers Etalons The Airy Function section Page: 11 Definition (Airy Function) Neglecting losses, the transmitted relative intensity is given by the Airy Function I t 1 = I ( ) (4) i 1 + F sin 2 δ 2

FPI T 2014 Fabry-Perot Spectrometers Etalons The Airy Function section Page: 11 Definition (Airy Function) Neglecting losses, the transmitted relative intensity is given by the Airy Function I t I i = 1 1 + F sin 2 ( δ 2 ) (4) The parameter δ is the phase difference between successively reflected beams. It depends on the wavelength λ of the incident light, the spacing d between the etalon plates, the refractive index η of the spacer material, and the incidence angle θ of the incoming light. Definition (Coeffi cient of Finesse) The quantity F is known at the coeffi cient of finesse.

FPI T 2014 Fabry-Perot Spectrometers Etalons The Airy Function section Page: 11 Definition (Airy Function) Neglecting losses, the transmitted relative intensity is given by the Airy Function I t I i = 1 1 + F sin 2 ( δ 2 ) (4) The parameter δ is the phase difference between successively reflected beams. It depends on the wavelength λ of the incident light, the spacing d between the etalon plates, the refractive index η of the spacer material, and the incidence angle θ of the incoming light. Definition (Coeffi cient of Finesse) The quantity F is known at the coeffi cient of finesse. It is determined by the amplitude reflection coeffi cient r of the plate coatings ( ) 2r 2 F = 1 r 2 (5) (Note that we usually specify the plate coating reflectance R rather than the reflection coeffi cient, with R = r 2.)

FPI T 2014 Fabry-Perot Spectrometers Etalons section Page: 12 Spectral Profile of the Transmission and Reflections 1 I t I i 1 F = 0.2 F = 2 F = 20 F = 150 0 2π δ/2 4π F = 150 F = 20 Transmission Reflection The etalon transmission is described by the Airy function which, if the plate reflectance is high, only allows light to pass through when the interference order is close to a whole integer. I t I i F = 2 F = 0.2 0 2π δ/2 4π

FPI T 2014 Fabry-Perot Spectrometers Etalons section Page: 12 Spectral Profile of the Transmission and Reflections 1 I t I i 1 I t I i F = 0.2 F = 2 F = 20 F = 150 0 2π δ/2 4π F = 150 F = 20 F = 2 F = 0.2 Transmission Reflection 0 2π δ/2 4π The etalon transmission is described by the Airy function which, if the plate reflectance is high, only allows light to pass through when the interference order is close to a whole integer. The coeffi cient of finesse determines the "sharpness" of the fringes, and how deeply modulated they are. The bottom panel shows one minus the Airy function, and describes the reflected intensity.

FPI T 2014 Fabry-Perot Spectrometers Etalons section Page: 13 Airy Function in Terms of Instrumental Parameters Question: The Airy function depends on the phase difference δ between successively reflected beams or, equivalently, on the interference order m, which is just m = δ /2π.

FPI T 2014 Fabry-Perot Spectrometers Etalons section Page: 13 Airy Function in Terms of Instrumental Parameters Question: The Airy function depends on the phase difference δ between successively reflected beams or, equivalently, on the interference order m, which is just m = δ /2π. But how do we calculate δ or m in terms of instrumental parameters like θ, λ, or d?

FPI T 2014 Fabry-Perot Spectrometers Etalons section Page: 13 Airy Function in Terms of Instrumental Parameters Question: Answer: The Airy function depends on the phase difference δ between successively reflected beams or, equivalently, on the interference order m, which is just m = δ /2π. But how do we calculate δ or m in terms of instrumental parameters like θ, λ, or d? The expression for m is derived the same way as one does for thin film interference. The derivation is straightforward, though care must be taken to account for all contributions to phase lag. The result is that where m = 2ηd cosθ λ η = refractive index between the plates d = plate separation thickness θ = optical incidence angle λ = wavelength

FPI T 2014 Fabry-Perot Spectrometers Etalons section Page: 13 Airy Function in Terms of Instrumental Parameters Question: Answer: The Airy function depends on the phase difference δ between successively reflected beams or, equivalently, on the interference order m, which is just m = δ /2π. But how do we calculate δ or m in terms of instrumental parameters like θ, λ, or d? The expression for m is derived the same way as one does for thin film interference. The derivation is straightforward, though care must be taken to account for all contributions to phase lag. The result is that 2ηd cosθ m = λ η = refractive index between the plates d = plate separation thickness where θ = optical incidence angle λ = wavelength So the etalon transmission is actually a function of everything that m depends on: d, θ, λ, and η.

FPI T 2014 Fabry-Perot Spectrometers Etalons section Page: 13 Airy Function in Terms of Instrumental Parameters Question: Answer: The Airy function depends on the phase difference δ between successively reflected beams or, equivalently, on the interference order m, which is just m = δ /2π. But how do we calculate δ or m in terms of instrumental parameters like θ, λ, or d? The expression for m is derived the same way as one does for thin film interference. The derivation is straightforward, though care must be taken to account for all contributions to phase lag. The result is that 2ηd cosθ m = λ η = refractive index between the plates d = plate separation thickness where θ = optical incidence angle λ = wavelength So the etalon transmission is actually a function of everything that m depends on: d, θ, λ, and η. If we keep any three of these constant, the transmission is a periodic function of the remaining parameter.

FPI T 2014 Fabry-Perot Spectrometers Etalons section Page: 13 Airy Function in Terms of Instrumental Parameters Question: Answer: The Airy function depends on the phase difference δ between successively reflected beams or, equivalently, on the interference order m, which is just m = δ /2π. But how do we calculate δ or m in terms of instrumental parameters like θ, λ, or d? The expression for m is derived the same way as one does for thin film interference. The derivation is straightforward, though care must be taken to account for all contributions to phase lag. The result is that 2ηd cosθ m = λ η = refractive index between the plates d = plate separation thickness where θ = optical incidence angle λ = wavelength So the etalon transmission is actually a function of everything that m depends on: d, θ, λ, and η. If we keep any three of these constant, the transmission is a periodic function of the remaining parameter. In particular, if we hold d, η, and θ constant, then the etalon transmission is solely a function of wavelength.

FPI T 2014 Fabry-Perot Spectrometers Etalons Typical Airy Function section Page: 14 This figure shows the transmission of a perfect air-spaced etalon with a gap of d = 3.78mm and a plate coating reflectance of R = 0.88. 2 2 The pass bands peak at 100% transmission, which is unrealistic. Losses, mostly in the plate coatings, typically restrict the peak transmission of the passbands to something more like 0.7.

FPI T 2014 Fabry-Perot Spectrometers Etalons Typical Airy Function section Page: 14 This figure shows the transmission of a perfect air-spaced etalon with a gap of d = 3.78mm and a plate coating reflectance of R = 0.88. 2 Note how narrow the pass bands are the FWHM is about 2pm. 2 The pass bands peak at 100% transmission, which is unrealistic. Losses, mostly in the plate coatings, typically restrict the peak transmission of the passbands to something more like 0.7.

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods Imaging the Fringes section Page: 15 Etalon Lens Imaging detector Imaging detectors record simultaneously the transmitted brightness as a function of θ, over a range of incidence angles.

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods Imaging the Fringes section Page: 15 Etalon Lens Imaging detector Imaging detectors record simultaneously the transmitted brightness as a function of θ, over a range of incidence angles. If we illuminate the etalon monochromatically, the result is a series of concentric circular Fabry-Perot fringes.

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods The interference order is given by Angular Field of View m = 2µd cosθ. λ The condition for j interference orders in the pattern is thus j = So for the j-th fringe, θ j = 2µd cos0 λ µdθ 2 j λ, jλ µd section Page: 16 2µd cosθ j λ Therefore, to image 8 fringes at 630nm with an etalon of spacing d = 3.78mm, θ 8 2, whereas for d = 20mm we have θ 8 0.9. Conversely, for a pinhole passing only (say) 1 20 th of an order, θ 0.05 4 arc minutes. Fringe imaging instruments obviously accept far more light, which is why most modern instruments work in this mode.

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods section Page: 17 Using a Fabry-Perot Etalon to Record Spectra It is possible to make etalons with large aperture plate diameters up to 150mm are common in aeronomy applications. By using coating reflectances greater than 0.8 and gaps greater than 3mm, it is possible to achieve spectral passbands narrower than the 3pm required for aeronomic Doppler sectroscopy. Thus, Fabry-Perot etalons have been used since the 1960 s to measure Doppler spectra of the airglow and aurora, for the purpose of estimating the large scale background wind and temperature fields in the thermosphere [Wark, 1960; Jarrett and Hoey, 1966; Roble et al., 1968.]

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods section Page: 17 Using a Fabry-Perot Etalon to Record Spectra It is possible to make etalons with large aperture plate diameters up to 150mm are common in aeronomy applications. By using coating reflectances greater than 0.8 and gaps greater than 3mm, it is possible to achieve spectral passbands narrower than the 3pm required for aeronomic Doppler sectroscopy. Thus, Fabry-Perot etalons have been used since the 1960 s to measure Doppler spectra of the airglow and aurora, for the purpose of estimating the large scale background wind and temperature fields in the thermosphere [Wark, 1960; Jarrett and Hoey, 1966; Roble et al., 1968.] θ Etalon η Field stop Light meter d Question: We still need to tune the pass bands in wavelength, if we are record spectra. How can we do this?

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods section Page: 17 Using a Fabry-Perot Etalon to Record Spectra It is possible to make etalons with large aperture plate diameters up to 150mm are common in aeronomy applications. By using coating reflectances greater than 0.8 and gaps greater than 3mm, it is possible to achieve spectral passbands narrower than the 3pm required for aeronomic Doppler sectroscopy. Thus, Fabry-Perot etalons have been used since the 1960 s to measure Doppler spectra of the airglow and aurora, for the purpose of estimating the large scale background wind and temperature fields in the thermosphere [Wark, 1960; Jarrett and Hoey, 1966; Roble et al., 1968.] θ Etalon η Field stop Light meter d Question: We still need to tune the pass bands in wavelength, if we are record spectra. How can we do this?. Answer: By varying one of the etalon s operating parameters θ, η, or d.

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods Question: Multiple Pass Bands? section Page: 18 But how can we use an etalon as the basis for a spectrometer? Previously we said we needed to isolate a single narrow pass band, whereas here we have heaps of them. What s up?

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods Question: Answer: Multiple Pass Bands? section Page: 18 But how can we use an etalon as the basis for a spectrometer? Previously we said we needed to isolate a single narrow pass band, whereas here we have heaps of them. What s up?. Part of the answer is that we use a narrow band interference filter to block most of the pass bands. A typical narrow band-pass filter profile is shown below..

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods section Page: 19 Pass Bands of the Etalon-and-Filter Combnation This figure shows the pass bands of an etalon and filter in series. 3 Now although we can usually tune the etalon pass bands in wavelength, the filter is not (normally) tuned. So, as the instrument scans in wavelength, the narrow pass bands move through the filter envelope. 3 Here I have used an etalon gap of d = 3.78mm for clarity; it results in relatively few pass bands within the filter envelope. While this configuration works fine, other practical considerations mean that most modern instruments use larger gaps (10 to 20mm.) This results in the pass bands being closer spaced in wavelength, so that many more would occur inside the filter envelope.

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods A Truly Stupid Spectrometer section Page: 20 But even after adding a filter, we still haven t reduced the transmission down to one isolated narrow passband. As shown here, the resuting instrument is still completely hopeless for (say) recording a spectrum of sunlight. Question: So can it possibly be useful?

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods A Truly Stupid Spectrometer section Page: 20 But even after adding a filter, we still haven t reduced the transmission down to one isolated narrow passband. As shown here, the resuting instrument is still completely hopeless for (say) recording a spectrum of sunlight. Question: Answer: So can it possibly be useful?. Multple pass bands aren t a problem provided there is only one narrow spectral line within the filter envelope.

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods Nightglow Spectroscopy section Page: 21 The aeronomic application in which a single etalon spectrometer works well is nightglow spectroscopy in which we can usually ensure that the dark sky illumination contains only one spectral emission line (shown here in red) within the system of instrumental pass bands (shown here in black.)

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods section Page: 22 What We Get from Fabry-Perot Nightglow Spectral Measurements Using a single etalon spectrometer (with filter) to observe a single nightglow produces the output shown here. As each pass band sweeps over the emisison line, a new peak appears in the recorded spectrum. Each new peak actually corresponds to transmission by the etalon at a different interference order. Since we only want to define the shape of the emission line itself, we can use any one of these recorded peaks for that. Actually, there is no need to scan over more than one order, although we can of course do so if we wish.

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods section Page: 23 Etalon Imperfections The Airy function sets an upper limit on instrumental resolution, assuming the etalon plates are perfectly flat and that they are aligned perfectly parallel.

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods section Page: 23 Etalon Imperfections The Airy function sets an upper limit on instrumental resolution, assuming the etalon plates are perfectly flat and that they are aligned perfectly parallel. In practice, neither of these can hold exactly; all real etalons are imperfect. For example: Surface Roughness Lack of Parallelism Spherical Defect

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods section Page: 23 Etalon Imperfections The Airy function sets an upper limit on instrumental resolution, assuming the etalon plates are perfectly flat and that they are aligned perfectly parallel. In practice, neither of these can hold exactly; all real etalons are imperfect. For example: Surface Roughness Lack of Parallelism Spherical Defect The effect of such defects is that the etalon behaves like a montage of a large number of small elemental etalons, each with a slightly different gap. When expressed in terms of wavelength, the Airy functions of these elemental etalons are all shifted slightly relative to each other.

FPI T 2014 Fabry-Perot Spectrometers Scanning Methods section Page: 23 Etalon Imperfections The Airy function sets an upper limit on instrumental resolution, assuming the etalon plates are perfectly flat and that they are aligned perfectly parallel. In practice, neither of these can hold exactly; all real etalons are imperfect. For example: Surface Roughness Lack of Parallelism Spherical Defect The effect of such defects is that the etalon behaves like a montage of a large number of small elemental etalons, each with a slightly different gap. When expressed in terms of wavelength, the Airy functions of these elemental etalons are all shifted slightly relative to each other. Thus, there is a distribution of shifts, peaked around the mean. The net result is to broaden the wavelength transmission function of the etalon, as shown. It is the width δ E λ of this summed transmission that actually limits the wavelength resolution. Summed Envelope Numerous slightly shifted Airy functions Width δ Eλ

FPI T 2014 Fabry-Perot Spectrometers Imaging Detectors Recording Spectra section Page: 24 Source spectrum Definition (Scan Type) To scan the etalon in wavelength, we must vary one of its operating parameters. Depending on which one we vary, the type of scan is known as: λ λ Etalon transmission function. Scan the pass bands in wavelength by varying d, θ, or η Recorded function Scan λ

FPI T 2014 Fabry-Perot Spectrometers Imaging Detectors Recording Spectra section Page: 24 λ λ Source spectrum Etalon transmission function. Scan the pass bands in wavelength by varying d, θ, or η Definition (Scan Type) To scan the etalon in wavelength, we must vary one of its operating parameters. Depending on which one we vary, the type of scan is known as: d : Varying the etalon gap is known as separation scanning. Typically this is done piezoelectrically. Recorded function Scan λ

FPI T 2014 Fabry-Perot Spectrometers Imaging Detectors Recording Spectra section Page: 24 λ λ Source spectrum Etalon transmission function. Scan the pass bands in wavelength by varying d, θ, or η Definition (Scan Type) To scan the etalon in wavelength, we must vary one of its operating parameters. Depending on which one we vary, the type of scan is known as: d : η : Varying the etalon gap is known as separation scanning. Typically this is done piezoelectrically. This is known as refractive index scanning. It is usually done by varying gas pressure in a sealed etalon chamber. Recorded function Scan λ

FPI T 2014 Fabry-Perot Spectrometers Imaging Detectors Recording Spectra section Page: 24 λ λ Scan λ Source spectrum Etalon transmission function. Scan the pass bands in wavelength by varying d, θ, or η Recorded function Definition (Scan Type) To scan the etalon in wavelength, we must vary one of its operating parameters. Depending on which one we vary, the type of scan is known as: d : η : θ : Varying the etalon gap is known as separation scanning. Typically this is done piezoelectrically. This is known as refractive index scanning. It is usually done by varying gas pressure in a sealed etalon chamber. This is known as angular scanning or sometimes as spatial scanning. Today, it is easily achieved without having to scan over time, by simply recording a 2D image of the fringes.

FPI T 2014 Fabry-Perot Spectrometers Imaging Detectors Circular Interference Fringes section Page: 25 Fabry-Perot fringes are formed when monochromatic light illuminates the etalon s pass bands, which are paraboloids a when plotted as functions of wavelength and 2-dimensional incidence angle. Each successive shell corresponds to an integer increment of one in interference order. The figure shows why a static etalon with an imaging detector can function as a spectrometer: the center wavelength of each pass band decreases with increasing incidence angle. Effectively, the pass band is scanned by radial distance on the detector. a The paraboloidal shape arises from the cosθ term in the expression for intrference order.

FPI T 2014 Fabry-Perot Spectrometers Imaging Detectors Recovering Spectra from Static Fringes section Page: 26 Provided that neither the brightness nor the spectral distribution B(λ ) of the illumination varies across the etalon s angular field of view, then the two-dimensional fringe shapes are determined solely 4 by the Airy function A(d,η,θ,λ ) of the etalon at each pixel, spectrally convolved with B(λ ). 4 Neglecting the effects of etalon defects. While it is essential to account for these in a real experiment, we need not concern ourselves with how this is done here.

FPI T 2014 Fabry-Perot Spectrometers Imaging Detectors Recovering Spectra from Static Fringes section Page: 26 Provided that neither the brightness nor the spectral distribution B(λ ) of the illumination varies across the etalon s angular field of view, then the two-dimensional fringe shapes are determined solely 4 by the Airy function A(d,η,θ,λ ) of the etalon at each pixel, spectrally convolved with B(λ ). Knowing A, it then possible to recover the source spectrum B(λ ). 4 Neglecting the effects of etalon defects. While it is essential to account for these in a real experiment, we need not concern ourselves with how this is done here.

FPI T 2014 Fabry-Perot Spectrometers Imaging Detectors Recovering Spectra from Static Fringes section Page: 26 Provided that neither the brightness nor the spectral distribution B(λ ) of the illumination varies across the etalon s angular field of view, then the two-dimensional fringe shapes are determined solely 4 by the Airy function A(d,η,θ,λ ) of the etalon at each pixel, spectrally convolved with B(λ ). Knowing A, it then possible to recover the source spectrum B(λ ). The video below illustrates one possible procedure for doing this. 4 Neglecting the effects of etalon defects. While it is essential to account for these in a real experiment, we need not concern ourselves with how this is done here.

FPI T 2014 Fabry-Perot Spectrometers Imaging Detectors section Page: 27 Example Data Clemson University Fabry-Perot at Fort Yukon

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers All-Sky Doppler Imaging section Page: 28 The SDI views multiple interference orders and scans its etalon gap over time, producing many independent spectra mapped across the sky. This image shows λ 558nm spectra from 261 zones across the sky (white) and the measured instrumental passbands (orange). Green hues show 558nm brightness, blue through red hues show Doppler temperature, and yellow arrows show the fitted horizontal

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Conjugate Sky Fringes section Page: 29 For a sky viewing instrument, we can always guarantee that the source spectrum is constant across etalons field of view, by scrambling the angular information from the sky using a diffuser or scatterer (e.g., an integrating sphere).

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Conjugate Sky Fringes section Page: 29 For a sky viewing instrument, we can always guarantee that the source spectrum is constant across etalons field of view, by scrambling the angular information from the sky using a diffuser or scatterer (e.g., an integrating sphere). Problem: But what if we want to preserve the angular information? (To map Doppler shift and width across the sky.)

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Conjugate Sky Fringes section Page: 29 For a sky viewing instrument, we can always guarantee that the source spectrum is constant across etalons field of view, by scrambling the angular information from the sky using a diffuser or scatterer (e.g., an integrating sphere). Problem: But what if we want to preserve the angular information? (To map Doppler shift and width across the sky.) Optically, there is nothing to stop us from forming interference fringes that are conjugate with the plane of the sky.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Conjugate Sky Fringes section Page: 29 For a sky viewing instrument, we can always guarantee that the source spectrum is constant across etalons field of view, by scrambling the angular information from the sky using a diffuser or scatterer (e.g., an integrating sphere). Problem: But what if we want to preserve the angular information? (To map Doppler shift and width across the sky.) Optically, there is nothing to stop us from forming interference fringes that are conjugate with the plane of the sky. As seen opposite, the result is then a sky image that is modulated by the fringe pattern. This shows some of the first night-sky images taken with the new Mawson FPS, from a site with lots of trees in the field of view. Fringes in the upper image are from mid-latitude 630nm airglow, whereas the lower panel show 558nm fringes.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Conjugate Sky Fringes section Page: 29 For a sky viewing instrument, we can always guarantee that the source spectrum is constant across etalons field of view, by scrambling the angular information from the sky using a diffuser or scatterer (e.g., an integrating sphere). Problem: But what if we want to preserve the angular information? (To map Doppler shift and width across the sky.) Optically, there is nothing to stop us from forming interference fringes that are conjugate with the plane of the sky. As seen opposite, the result is then a sky image that is modulated by the fringe pattern. This shows some of the first night-sky images taken with the new Mawson FPS, from a site with lots of trees in the field of view. Fringes in the upper image are from mid-latitude 630nm airglow, whereas the lower panel show 558nm fringes. But now the spectral distribution can no longer be recovered unambiguously, because the fringe shapes also depend on the angular distribution of source brightness.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Optical Layout section Page: 30

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Scanning the Etalon Gap section Page: 31 The solution is to scan the etalon gap in time, so that the spectrum at each pixel is encoded as a function of etalon gap, rather than image position.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Scanning the Etalon Gap section Page: 31 The solution is to scan the etalon gap in time, so that the spectrum at each pixel is encoded as a function of etalon gap, rather than image position. While each pixel correctly records a spectrum, regardless of the brightness distribution in the scene, the phase of the recorded spectra varies according to the axial angle θ that maps to each pixel.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Scanning the Etalon Gap section Page: 31 The solution is to scan the etalon gap in time, so that the spectrum at each pixel is encoded as a function of etalon gap, rather than image position. While each pixel correctly records a spectrum, regardless of the brightness distribution in the scene, the phase of the recorded spectra varies according to the axial angle θ that maps to each pixel. To co-add or even to compare spectra from different pixels requires correction for this phase shift.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Phase Mapping section Page: 32 Correction for the phase difference is easy:

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Phase Mapping section Page: 32 Correction for the phase difference is easy: 1 Fill the field of view with light from spectrally narrow and stable calibration lamp (e.g., a frequency stabilized laser.)

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Phase Mapping section Page: 32 Correction for the phase difference is easy: 1 Fill the field of view with light from spectrally narrow and stable calibration lamp (e.g., a frequency stabilized laser.) 2 Scan the etalon in gap over one interference order ( d = 2µ cosθ λ λ /2)

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Phase Mapping section Page: 32 Correction for the phase difference is easy: 1 Fill the field of view with light from spectrally narrow and stable calibration lamp (e.g., a frequency stabilized laser.) 2 Scan the etalon in gap over one interference order ( d = 2µ cosθ λ λ /2) 3 Record at each pixel the scan channel at which the spectrum peaks.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Phase Mapping section Page: 32 Correction for the phase difference is easy: 1 Fill the field of view with light from spectrally narrow and stable calibration lamp (e.g., a frequency stabilized laser.) 2 Scan the etalon in gap over one interference order ( d = 2µ cosθ λ λ /2) 3 Record at each pixel the scan channel at which the spectrum peaks. The result is a map of the phase difference between successively reflected beams, across the field of view.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Image Zoning section Page: 33 For atmospheric wind and temperature mapping, we do not need separate spectra from every pixel.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Image Zoning section Page: 33 For atmospheric wind and temperature mapping, we do not need separate spectra from every pixel. Rather, we sum sets of adjacent pixels spectra into zones, as shown here.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Image Zoning section Page: 33 For atmospheric wind and temperature mapping, we do not need separate spectra from every pixel. Rather, we sum sets of adjacent pixels spectra into zones, as shown here. To do so, we must shift all pixel responses to a common phase, which is possible because of the phase map.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Image Zoning section Page: 33 For atmospheric wind and temperature mapping, we do not need separate spectra from every pixel. Rather, we sum sets of adjacent pixels spectra into zones, as shown here. To do so, we must shift all pixel responses to a common phase, which is possible because of the phase map. This trades lower spatial resolution for higher temporal resolution.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers Image Zoning section Page: 33 For atmospheric wind and temperature mapping, we do not need separate spectra from every pixel. Rather, we sum sets of adjacent pixels spectra into zones, as shown here. To do so, we must shift all pixel responses to a common phase, which is possible because of the phase map. This trades lower spatial resolution for higher temporal resolution. 47 zones are allocated here. We have in the past used between 25 and 119 zones.

FPI T 2014 Fabry-Perot Spectrometers Scanning Doppler Imagers section Page: 34 A Scaning Doppler Imager for Studying the Aurora

FPI T 2014 Fabry-Perot Spectrometers Daytime Instruments section Page: 35 Etalons in Series A single Fabry-Perot etalon has multiple wavelength passbands, so is of little use for sources whose spectral width exceeds the etalon s free spectral range.

FPI T 2014 Fabry-Perot Spectrometers Daytime Instruments section Page: 35 Etalons in Series A single Fabry-Perot etalon has multiple wavelength passbands, so is of little use for sources whose spectral width exceeds the etalon s free spectral range. If we need to study a broadband source, yet still achieve narrow spectral width, we can use two or more etalons of slightly different gap, coupled in series.

FPI T 2014 Fabry-Perot Spectrometers Daytime Instruments section Page: 35 Etalons in Series A single Fabry-Perot etalon has multiple wavelength passbands, so is of little use for sources whose spectral width exceeds the etalon s free spectral range. If we need to study a broadband source, yet still achieve narrow spectral width, we can use two or more etalons of slightly different gap, coupled in series. Consider the transmission of two such etalons, with gaps related as d 2 = 0.88d 1 : Etalon one Etalon two Product of the two transmission functions