Pumps type MP Motor pump combination for mounting into tanks for on/off service

Similar documents
Pumps type MP Motor pump combination for mounting into tanks for on/off service

Radial piston pump type R and RG

Safety valve with unit approval type MV..X.., SV..X..

Directional spool valve type SWPN Nom. size 6 or 10 conforming DIN

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Drive electronics pq12

Digital AC Motors MHD

AC axial compact fan

Operating Instructions for Digital Manometer. Model: MAN-SD

SVH with HYDROVAR (HVL range)

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Cartridge Valves Technical Information. Quick reference

External gear pump Type G3, Series 3X

maintenance-free in continuous duty low-noise space-saving extremely tough Suction capacity in m 3 /h m 3 /h 2500 Suction capacity 30,000 10,000

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

AC axial compact fan

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

VOLUMEC. Valve Position Indicator 5

4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

VK2 volume flow controller Overview

Series 3000 and XE-Series Engineering Data

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

2-way proportional throttle valve for block installation

LES. Single-stage end-suction pumps Identification Type key

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DBS315 1-phase SIDE CHANNEL BLOWERS

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

VD1 CLC. Small Valves DIN-range with a higher k v -value

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Cooler-Bypass Thermostat Valve, Size 10

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres

A 954 C HD. Technical Description Hydraulic Excavator. Machine for Industrial Applications

Rotary modules.

Exp All technology at operator s service. Suggested Orange peel. Straight boom m. Industrial straight stick 8.00 m RV 600 2,

3VT4 Molded Case Circuit Breakers up to 1000 A

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

HYDRAULIC POWER PACKS

Calio-Therm NC Type Series Booklet

Metallized polyester film capacitors MKT 470

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

RoHS. Versatile. X g. X 2 e

Single Phase Motors Technical Datasheets

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

W250: Compact photoelectric switch series for a broad range of applications

INTERNATIONAL STANDARD

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

Cooling Water Flow Regulator

APEX DYNAMICS, INC. Staianless

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

Solenoid valves Type EVUL

Applied Fluid Mechanics

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

INTERNATIONAL STANDARD

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

Clausing Industrial, Inc. Variable Speed 20" Single and Multi-spindle, Belt Drive Industrial Drill Presses

14:1400 (0206) KRAL Volumeter - OMG

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

DETERMINATION OF AIRBORNE SOUND POWER LEVELS EMITTED BY GEAR UNITS

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

DC/DC regulator Input V Output up to 16 A

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters

Electronic pressure-independent characterised control valve EPIV

DC/DC converter Input 9-36 and Vdc Output up to 0.5A/3W

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

HVM 061 Page 1/4 Elektrohydraulic Servovalves Typ HVM 061 Symbol A B P T L Special features: high reliability easy service robust construction high dy

Application Your benefits

Mechanical flow-rate controllers

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

flexotherm 230V Heat pump technical specification

AIR COOLED CONDENSING UNIT

ELECTROHYDROSTATIC PUMP UNIT

EXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

Modular contactors for installation into distribution

Absolute encoders multiturn

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Thermal-Magnetic Circuit Breaker 2210-S2..

Transcription:

Pumps type MP Motor pump combination for mounting into tanks for on/off service For hydraulic power packs with tank suited for direct mounting of the valves, see D 700 H Pressure p max Delivery flow Q max 700 bar (radial piston pump) 00 bar (gear pump) 4. lpm (radial piston pump) 1 lpm (gear pump) Single circuit pump Dual circuit pump (double pump) 1. General information The pumps type MP are intended to be installed in tanks. Special feature is the arangement of pump and motor being oil immersed. This arrangement yields a number of advantages when compared with power packs of conventional style: o Higher permissible exploitation of the motor output due to the intensive cooling effect of the surrounding oil o Lower operating noise by the absence of dire ctly emitted operation noise from fan and motor as well as by the muffling effect of the hydraulic fluid o Low space requirements due to compact design: Pump and motor are mounted on and into one another. The pumps should be used preferable for short time and on/off service S and S. No-load operation S6 is possible, de-pending on pump size and load. The operating modes (VDE 00): o S = Short time operation S = Intermittent service (on/off service) Main operating modes for the use of these pumps S 6 = Permanent operation with intermittent load (no-load operation). Permissible only at sufficiently large tank. Hydraulic power packs type HK acc. to D 7600- (-, -4) or pumps type R acc. to D 6010, type Z acc. to D 0 or type RZ acc. to D 6910 should be utilized for such cases. o The load duration per operating cycle shouldn t exceed min., see section. o The relative duty cycle varies depending on operating mode and size of the tank, see section.. The nom. voltage must be specified with your order, see section.. 1.1 Single circuit pumps Dual circuit pumps (double pumps) Radial piston pumps for high pressure systems up to 700 bar Gear pumps for midpressure systems up to 00 bar Radial piston pump + gear pump Gear pump + gear pump Type MP... - H... Type MP... - Z... Type MP... - H... - Z... Type MP... - Z... - Z... Hawe Hydraulik SE STREITFELDSTR. 8167 MÜNCHEN D 700 1978 by HAWE Hydraulik November 014-00

D 700 page. Available versions, main data.1 Single circuit pumps (radial piston pumps) intended for -phase mains and for 1-phase mains For gear pumps, see section. Order example: MP 4 A - H 0,81 + 0/400V 0Hz Specification of motor voltage Pump Basic type and size Nom. speed 140 rpm Nom. speed 80 rpm Coding Piston diameter Piston number 1 ) (mm) V g Geometric displacement (cm /rev) Delivery flow Q max (lpm) Version for -phase mains Version for 1-phase mains ) MP 14 A MP 4 A MPW 14 MPW 4 Operation condenser C B (µf) approx. 400V DB 8 16 Pressure p max (reference value) p cold (bar) / p warm (bar) ) Delivery flow Q max (lpm) Version for -phase mains Version for 1-phase mains ) MP 1 A MP A MPW 1 MPW Operation condenser C B (µf) 1 16 Pressure p max (reference value) p cold (bar) / p warm (bar) ) H 0,18 H 0,7 H 0,46 H 0,8 H 0,4 H 0,7 H 0,4 H 0,64 H 1,08 H 0,6 H 0,81 H 1,9 H 0,7 H 1,1 H 1,77 H 0,9 H 1, H,7 4 6 7 8 9 0.1 0.19 0.1 0.197 0.9 0.49 0.8 0.4 0.71 0.8 0.8 0.96 0.0 0.7 1.6 0.64 0.9 1.9 0.18 0.7 0.46 0.8 0.4 0.7 0.9 0.64 1.0 0. 0.8 1.7 0. 1.07 1.7 0.87 1..1 40/460 80/0 80/0 10/180 170/140 700/660 40/460 70/70 70/60 400/00 40/40 40/40 00/0 40/40 40/40 40/00 0/40 40/90 40/00 170/10 10/0 100/90 700/610 700/60 460/90 700/0 0/40 0/70 70/00 90/0 0/00 40/80 00/0 180/10 40/00 0/00 140/10 0. 0.88 0.8 1.7 1.18 1.94 1.61.69.1.1.71 4. 60/0 40/80 0/80 0/10 00/170 60/0 700/640 40/80 70/70 0/470 0/80 40/40 40/60 0/0 40/40 0/80 00/170 40/80 90/4 00/170 10/10 0/90 90/70 700/670 480/400 700/60 10/40 00/60 0/40 0/00 10/180 90/0 60/0 10/10 00/0 00/170 10/100 0/00 10/10 90/80 1) Indications for versions with two pistons: Significant pulsation will occur due to the low number of pistons. Their principal utilization is with gear pumps as dual stage pump (for possible combinations, see section..1) where a high pressure stage is needed only briefly to achieve a certain pressure level (e.g. at press controls). For complete two stage units (pump, tank, two stage valve, accessories and valve controls), see D 700 H. ) The motors of the version for 1-phase mains have main and help winding (condenser motors). The condenser is not scope of delivery and has to be customer furnished. Attention: The versions for 1-phase (AC) may only start against a very low pressure. Therefore the control must enable a pressureless start e.g. by means of an idle circulation solenoid valve, which is held open during start for a period of approx. 0. to 1s (e.g. by means of a delay relays). ) Upper value p cold = Permissible pressure for cold motor and short time operation S Lower value p warm = Permissible pressure for operation warm motor (max. fluid temperature 80 C) on/off service S and no-load operation S 6

D 700 page. Single circuit pump (gear pump) Versions for -phase and 1-phase mains Order example: MP 4 A - Z, Basic type and size Pump coding + 0/400V 0Hz Specification of motor voltage Note: Suction parts are available to the completion of the pump acc. to section 6! Version for -phase mains Size 0 1 Pump coding Z 0, Z 1,0 Z 1,8 Z,0 Z,7 Z, Z 4, Z, Z 6,9 Z 8,8 Z 9,8 Z, Z 9,0 Z 1, Z 16 V g Geom. displacement (cm /rev) 0.6 0.7 1. 1.4 1.9.41.1.9 4.76 6.1 7.0 7.9 6.0 8..0 Delivery flow Q max (lpm) 0. 1.0 1.8.0.7. 4.. 6.9 8.8 9.8.1 9 1. 16 Nom. speed 140 rpm Basic type and size Pressure p max (reference value) p cold (bar) / p warm (bar) 1 ) ) Delivery flow Q max (lpm) Nom. speed 80 rpm Basic type and size MP 14 A MP 4 A MP 1 A MP A 100/8 90/7 70/ 0/4 40/ /0 /0 0/1 10/10 180/180 160/140 10/0 100/8 8/70 6/ 0/4 40/ /0 0/40 /0 /0 1.0.0.7 4.4 6.9 9 10. 1. 17. 19. 1.8 17.1 4. 1. Pressure p max (reference value) p cold (bar) / p warm (bar) 1 ) ) 10/100 0/90 80/70 6/ 0/40 40/ 0/ 0/1 0/1 180/1 10/0 100/90 80/70 70/60 0/4 40/ /0 0/ 40/ 0/ /0 Version for 1-phase mains For necessary operation condensers, see tables in sect..1 Size Pump coding V g Geom. displacement Delivery flow Q max (cm /rev) (lpm) Nom. speed 140 rpm Basic type and size Pressure p max (reference value) p cold (bar) / p warm (bar) 1 ) ) Delivery flow Q max (lpm) Nom. speed 80 rpm Basic type and size MPW 14 MPW 4 MPW 1 MPW Pressure p max (reference value) p cold (bar) / p warm (bar) 1 ) ) 0 1 Z 0, Z 1,0 Z 1,8 Z,0 Z,7 Z, Z 4, Z, Z 6,9 Z 8,8 Z 9,8 Z, Z 9,0 Z 1, Z 16 0.6 0.7 1. 1.4 1.9.41.1.9 4.76 6.1 7.0 7.9 6.0 8..0 0. 1.0 1.8.0.7. 4.. 6.9 8.8 9.8.1 9 1. 16 0/9 60/0 /0 40/ /0 /0 0/0 1/1 10/8 140/10 10/0 9/80 7/6 60/0 0/40 /0 0/ /0 0/1 0/ 0/1 1.0.0.7 4.4 6.9 9 10. 1. 17. 19.0 1.0 17.1 4. 1. 100/8 9/80 0/4 0/4 /0 0/ 0/0 0/1 10/10 10/140 90/7 8/70 60/0 0/40 40/0 0/ /0 0/1 0/1 1 ) Upper value p cold Permissible pressure for cold motor and short time operation S Lower value p warm Permissible pressure for operation warm motor (max. fluid temperature 80 C) on/off service S and no-load operation S 6 ) The middled pressure of subsequent load cycles (e.g. at accumulator charging operation) should not exceed 0... 60% of p cold for applications above 160 bar to ensure an economic service life of the bearings.

D 700 page 4. Dual circuit pumps (double pumps) The main data for all indiv. pumps are listed in the tables of sections.1 and.. The pressure figures supplied there must be reduced depending on load, see notes in section....1 Combination radial piston pump - gear pump Order example: MP 4 A - H 0,81 - Z 9 Motor voltage + 0/400V 0Hz Note: In principle, the coding for the H... -pump section is named first within the basic type coding of MP...! Basic type and size Radial piston pump (high pressure pump) 1 Piston number 7 Z 0, Z 1,0 Z 1,8 Gear pump Z,0; Z,; Z 9,8 Z,7; Z 6,9; Z, Z,; Z 8,8 Z 9 Z 1, Z 16 MP 14 A MP 1 A MPW 14 MPW 1 H 0,7 H 0,4 H 0,64 H 0,81 H 1,1 H 1, o MP 4 A MP A MPW 4 MPW H 0,18 H 0,8 H 0,4 H 0,6 H 0,7 H 0,9 H 0,7 H 0,4 H 0,64 H 0,81 H 1,1 H 1, H 0,46 H 0,7 H 1,08 H 1,9 H 1,77 H,7 o o o Attention: Observe the load limits of the individual pumps as well as the complete system, see sect..1,. and.

D 700 page. Further data Valid for all pump versions.1 General and hydraulic Nomination Pipe connection Direction of rotation Constant delivery pump ISO 8/1 (BSPP), suited for pipe fittings with tapped journal shape B DIN 86 Bl.. For port sizes, see dimensional drawings in section 4 ++ MP...-H... any MP...-Z... MP...-H..-Z.. anti-clockwise Attention: Observe Direction of rotation in section.! Fastening See dimensional drawings in section 4 ++ Installed position Any, but the H pump section must be completely fluid immersed always. For details, see section.1. Pressure fluid Hydraulic oil conforming DIN 14 part 1 to : ISO VG 10 to conform. DIN 9. Viscosity range: Viscosity during start min. approx. 4; max. approx. 100 mm /s opt. service: approx. 10... 00 mm /s Also suitable are biologically degradable pressure fluids type HEES (Synth. Ester) at service temperatures up to approx. +70 C. Electrically hazardous: Any fluid types containing water must not be used (short-cut). Opt. operation viscosity: MP...-H... approx. 10... 00 mm /s MP...-Z... approx. 16... 00 mm /s Start viscosity: MP...-H... min. approx. 4 mm /s max. approx. 00... 800 mm /s to MP 1. A and MP. A MP...-Z... min. approx. 1 mm /s max. approx. 800... 1000 mm /s Temperature Ambient: approx. -40... +60 C. This is the main parameter for the expectant operation temperature, see also sect..! Fluid: -... +80 C, note the viscosity range! Attention: The expectant operation temperature may be estimated via curves in section.!. Mass (weight) approx. in kg Motor Type Mass (kg) MP 14A MPW 14.8 MP 4A MPW 4 6.1 Pump section Radial piston pump fitting MP 1... MP... H 0,18; 0,8 H 0,4; 0,6 H 0,7; 0,9.6 H 0,7; 0,4 H 0,64; 0,81 H 1,1; 1, 1..8 H 0,46; 0,7 H 1,08; 1,9 H 1,77;,7.0 H 0,; 0,41; 0, H 0,6; 0,; 1,0 H 0,9; 1, H 0,8; 1,; 1,4 H 1,6;,4;,8 H,;,6 H 1,7; 1,9;, H,;,8; 4,4 H 4,;,1 H,6; 6, H 1,4;,6 H,1;,7 H 4,; 6,0 H,8; 8,4 H 7,0; 8, H 9,8;,8 H 9,; 10,9 H 1,;1, Gear pump fitting MP 1... MP... Z 0, to Z 1,8 0.7 0.9 Z,0 to Z, 1. 1.6 Z 9 to Z 16

D 700 page 6. Elektric data Coding Nominal power P N (kw) Nominal speed n N (min -1 ) Nom. voltage 1) Permissible voltage ranges ) Nom. current 4) I N (A) 400V 0V 00V ) Start current ratio I A /I N Power factor cos. 9 Version with -phase motor MP 14 A 0. 10 MP 1 A 0.7 810 MP 4 A 0. 190 MP A 0.7 0 + 0/400V /! 0 Hz ( + 6/460V /! 60 Hz) for MP 1. A to MP. A +! 00V 0 Hz ) Mains 0 Hz: ±10% U N (conforming IEC 8) Mains 60 Hz: ±% U N 0.89 1. 0.6.8 0.70 1.0 1.7 0.80.7 0.80 1.6.8 1. 4.0 0.78.0. 1.48.0 0.8 Coding Nominal power P N (kw) Nominal speed n N (min -1 ) Nom. current 4) I N (A) Operation condenser C B (µf) Power factor cos. 9 Start current ratio I A /I N Version with AC-motor 1 + 0V 0 Hz 1 ) MPW 14 MPW 4 0.18 0.7 190 180 1.8.0 8 16 0.86 0.9.6. Connection cable m 1. mm² Isolation class Comparison protection class 7-leeds (optional 7 m, specify in uncoded text) F (winding), IEC (VDE 001 T1) Pump complete with motor IP 00; IP 4 (Hydraulic power pack D 700 H) DIN VDE 0470 / EN 609 / IEC 9 Attention: Do not connect radial piston pumps with -pole motors (MP 1 A - H.., MP A - H..) to mains 60 Hz. The resulting high speed (approx. 400 rpm) may cause increased running noise in general and uneven delivery flow at small piston diameters. Circuitries and cable connection -phase motor + 400V! 0 Hz + 0V / 0 Hz + 00V 0 Hz ) AC-motor 1 + 0V 0 Hz 1) Motors for other mains voltages and/or mains frequency 60 Hz on enquiry ) Max. permanent load 00V +1%, acc. to the supplier of the wire leads. ) The motors may be connected to mains voltage below these limits but reduced voltage will cause a performance drop (& reduced p max. ). 4) For actual current consumption, see section.4 ) 4-wire cable (W1, V1, U1, PE) is used for 00 V internal circuitry:! U tats p max, p k (p w ) Example: Motor nom. voltage 0/400V 0 Hz 1.1 U N (6/460V 60 Hz) Actual mains voltage 400V 60 Hz Selected pump MP 4 A - H 0,81 p max = 70 bar 400V p max, 70 bar 1.1 460V p max, 40 bar

D 700 page 7 4. Unit dimensions All dimensions in mm, subject to change without notice! 4.1 Pumps Single circuit pump (radial piston pump) Single circuit pump (gear pump) Dual circuit pump Type MP(W) 1..-H.. Type MP(W) 1..-Z.. Type MP(W) 1..-H..-Z.. Cable 4x1. Length 000 High pressure port Low pressure port Suction port M6, 10 deep Type MP(W) 1..-Z.. MP(W) 1..-H..-Z.. Z 0, Z 1,0 Z 1,8 Z,0 to Z 4, Z, Z 6,9 Z 8,8 to Z, NP and S M 10x1 M 10x1 M 10x1 H 1 1 1 18 1 8 8 7 H 4 4 6 4 49 49 8 B 48 48 48 a 1 101 101 10 109 h 17 17 140 14 10 10 19 i 7.7 7.7 7.7 For missing dimensions, see MP(W) 1..-H..

D 700 page 8 Single circuit pump (radial piston pump) Single circuit pump (gear pump) Dual circuit pump Type MP(W)..-H.. Type MP(W)..-Z.. Type MP(W)..-H..-Z.. High pressure port Cable 4x1. length 000 Low pressure port Suction port Type HP D H a c e g h h 1 MP(W)..-H.. G 1/8 140 19 7 6. M6, deep 108 87 Type MP(W)..-Z.. MP(W)..-H..-Z.. NP Z 0, M10x1 Z 1,0 M10x1 Z 1,8 M10x1 Z,0 to 4, Z, and 6,9 Z 8,8 to, Z 9 G 1/ and 1, Z 16 G 1/ S M10x1 M10x1 M10x1 G 1/ G /4 H 1 4 40 47 6 66 66 H 61 77 81 81 B 48 48 48 90 90 a 1 1 1 6 9 18 19 19 f h 14 14 147 1 160 169 179 179 i 7.7 7.7 7.7 1. 1. k 0 0 0 0 0 0 0 0

D 700 page 9. Notes for general lay-out and initial operation.1 Installation in customer furnished tanks The dimensions of a customer furnished tank should be selected in such a way that it is ensured that the motor is always oil immersed, even when the max. required fluid volume is removed. This way the performance rating of the power pack can be completely utilized. The perm. performance is reduced if the motor contour is partially or completely above the fluid level. When more than 1/4 of the motor is above the fluid level a no-load operation is no longer permissible but on/off service can be still provided. The thermal balance of the motor has to be checked (via resistance measurement acc. to VDE 00) if the fluid level drops even further. This temperature (resistance) check has to be undertaken several times until no more temperature rise can be detected; always after a load sequence when the pump has performed some operation cycles. The perm. fluid temperature is approx. 80 C, the perm. winding temperature is approx. 10 C (isolation class B). See also D 700 sect... Center line, see dimensional drawing Center line, see dimensional drawing Type MP...-H... The installed position of the pump is arbitrary, as long as the pump is immersed below the fluid level by h 1, h. Type MP...-Z... The installed position of the pump is arbitrary, as long as all suction parts are immersed below the fluid level by h. h = dependent on size, gear pump and chosen suction part (see dimensional drawings in sect. 4 and 6) Type MP 1.. MP.. h 1 6 70 h 80 90. Direction of rotation It is not necessary to observe the direction of rotation with type MP...-H..., whereas a certain direction of rotation is absolutely required for types MP...-H...-Z and MP...-Z. The rotation direction can t be detected in installed state (hydraulic power packs), but via checking the delivery flow. Procedure: Direct the flow from port P via a translucent hose back into the tank; Switch on/off the pump several times. When a flow is visible the direction is o.k. otherwise it has to be reversed by interchanging the connection of two of the three main wires of the motor. The pumps type MP...-Z...-Z... rotate anti-clockwise (facing the drive shaft) in delivery state. See also dimensional drawings in sect. 4++ where arrows indicate the rotation direction.. Motor load with dual circuit pumps It should be recalculated, that the product (pv) calc. of intended pressure p 1, p and all three possible load conditions is lower than (pv) calc. max. The pressure limits p cold and p warm acc. to sect..1 and. must be observed. Load condition 1 Load condition Load condition Type MP 14 A (MPW 14) MP 1 A (MPW 1) MP 4 A (MPW 4) MP A (MPW ) (pv) calc. max 14 (90) 170 (7) 40 (00) 90 (1) Both pumps work against one common pressure, p 1 = p = p (pv) calc. = p(v P1 + V P ) Only one pump works (V P1 against pressure, V P idles, p 1 = p (pv) calc. = pv P1 + V P 1 ) Both pumps work against different pressure simultaneously (pv) calc. = p 1 V P1 + p V P 1) A back pressure of approx. bar was considered for an idling pump.

D 700 page 10.4 Current consumption The following characteristics are reference values. You serve the inquiry of current consumption and expected heat built-up (see sect..) as well as for setting the protective motor switch (overload protection). Version for -phase mains Motor current I M (A) 400V! 0 Hz 1 ) (460V! 60 Hz) MP A MP 1 A MP 4 A MP 14 A Gear pump Radial piston pump MP 14 A MP 4 A Example: MP 1 A Chosen pump MP 4 A - H 1,1 Operation pressure of the system p oper = 0 bar V g = 0.7 cm /rev p V g = 6 bar cm Resulting in a motor current of approx..1 A MP A Performance value p V g (bar cm /U) 1) The reference values for the motor current have to be determined by conversion at other nom. voltages, e.g.: 400V Main 0V 0 Hz : I 0V, I 400V 0V Main 00V 0 Hz : I 00V, I 400V 400V 00V Version for 1-phase mains Motor current I M (A) 0V 0 Hz 1 ) MPW MPW 1 MPW 4 MPW 14 Gear pump Radial piston pump MPW 14 MPW 4 MPW 1 MPW Performance value p V g (bar cm /U)

D 700 page. Operation temperature The built-up of heat of the hydraulic power pack depends on different factors: Pump size, tank size, pressure (current consumption), operating mode (S, S, S6 acc. to VDE 00), etc. A formula that can be applied to all sizes, combinations and application cases can be achieved only by extreme simplification. The result should be regarded as a guideline only. These pumps are frequently operated only in a second range with subsequent stand-still periods for several minutes or even longer. A recalculation is unnecessary for all applications with such load cycles. Its use is limited to application at increased ambient temperatures, strong exploitation in the pressure limit range, prolonged load within an operation cycle etc. where knowledge about the persistent service temperature to be expected is essential. Main target is to find out whether the persistent service temperature will be below approx. 80 C. This recalculation only applies to hydraulic power packs fulfilling the following parameters: Tank completely filled up, fluid level won t drop below motor outline during operation, all fluid returns at the end of each cycle. The curve below illustrates the persistent operation temperature } B acc. to tests with stand alone hydraulic power packs featuring HAWE tanks (see D 700 H), it may be applied also to similar customer furnished tanks. Persistent operation temperature difference } B (K) Curves correspond to standard tanks acc. to D 700 H (example) Characteristic value for heat output C M l m Tank B B B10 B B B0 Filling volume 4. 7. 1. 7 10 V F (l) to to to to to 8. 17. 74 1 } B + } U $ 80 C Together, temperature gain plus ambient temperature (e.g. 0 C) should be below 80 C (sect..1 Fluid temperature) Persistent operation temperature difference C M ({) Motor constants (characteristc resistancevalues, calculated values only) Type MP 14 MP 4 MP 1 MP 400V 1 1 6 0 U 0V 7 17 1 10 N 00V 190 9 109 I m (A) Quadratic averaged current figure (during one operation cycle with duration T). The currents I 1, I, I... prevailing during periods t 1, t, t... are to be determined on the basis of the given pressure p 1, p, p... and the working volume VP (see sect..1), i.e. via the product p 1 V gp1, p V gp, p V gp... from the current curves (see sect..4). In the case of dual stage pumps, the periods t 1, t... are in most cases to be set for the subsequent load sequences (sect..) within the operation cycle. The corresponding currents I 1, I... are to be read off in sect..4 via the value (pv g ) calc. To be calculated in each case. Operating mode S (On/off service) I m = V ( ) 1 T l 1 t 1 + l t + l t +... Stand-still Operating mode S This can be regarded as a borderline case of S, but the temperature recalculation must, however, made on base of other criteria. What is of interest is the period of time, where the pump may be switched on without exceeding the limit temperature, and how long the subsequent standstill period must be in order to allow the pump to cool down to its initial temperature. This recalculation is not necessary for cases where the pump is only operated for a few minutes with subsequent standstill periods for more than 1/ hour. Operating mode S6 (No-load operation) I m = V 1 T l ( 1 t 1 + l t + l t + I L t L ) Not applicable for most small size tanks. The idle current I L can be taken from sect..4 für pv g = 0. No-load

D 700 page 1.6 Motor safeguarding against over heating (protective motor switch) The protective motor switch has to be adjusted in such a manner, that too early triggering is avoided during undisturbed operation and operation cycles permanently succeeding one another. Whereas it should safeguard the motor against over heating in case of stand-still due to a pressure limiting valve being adjusted to high, malfunction of a pressure switch which should trigger a stop signal etc. Guideline for proper setting of the protective switch: I E should be 0.7 I M in general, 0.6 I M for operation in the range of p max and 0.8 I M for low loads. The motor current I M can be read for various pressure settings of the pressure limiting valve in sect..4. Note: For temperature supervision of hydraulic power packs, see D 700 H!.7 Running noise MP...-H... MP...-Z... Sound pressure levels db(a) Delivery flow Q (l/min) Delivery flow Q (l/min) Note: The sound pressure level ranges shall serve to estimate the running noise to be expected. They approximately delimit the spreads recognizable during measuring. Pumps with smaller delivery flows tend as a rule to the lower, whereas larger ones tend to the upper limit. The noise level of dual circuit pumps is rather similar to the one of the bigger of the two pumps. The hydraulic power pack should be mounted on silent blocks to prevent or minimize the conduction of body sound onto other sound radiating machinery parts. Pipes to the consumers should be connected via short hoses to the hydraulic power unit. Rigid mounting on a surface capable of resonance (e.g. welded or thin-wall machine stands) may significantly amplify or conduct the operation noise level. We recommend to mount the hydraulic power pack via silentblocs. Further details may be found in the technical information of the respective manufacturer. Measuring conditions: Work room, interference level approx. db(a); measuring point 1 m above the floor; 1 m object clearance, pump standing on a sound deadening panel (height 0 mm). Object: Hydraulic power pack featuring a standard HAWE tank acc. to D 700 H. (complete power pack) Measuring device: Precision sound pressure level measuring instrument DIN IEC 61 Kl. I Fluid viscosity Pumps type MP..-H = 0 mm /s during tests: Pumps type MP..-Z = 100 mm /s.8 Notes to ensure EMC (Electromagnetic compatibility) Non permissible spikes are emitted (EN 6004-1 Abs. 19) when hydraulic power packs (inductive motor acc. to EN 6004-1 sect. 1.1..1) are connected to a system (e.g. power supply acc. to EN 6004-1 sect. 6). Tests regarding the conformity with EN 6004-1 sect. 1.1..1 and/or VDE 00-1 ( ) are not required. Electro-magnetic fields may be generated during switching the motor On/Off. This effect can be minimzed by means of a filter e.g. type 140, 400V AC 4kW 0-60Hz (Co. Murr-Elekronik, D-7170 Oppenweiler)

D 700 page 1 6. Suction parts for MP..-Z.. required for installation in customer furnished tanks These suction parts enable lowering of the fluid level below the pump outline thereby exceeding the usable volume. The sucking parts are delivered as unassembled component parts. The thread connections have to be sealed very carefully to avoid migration of air. Best apply common PTFE seal tape starting after the. or. pitches of the fittings conical thread therby preventing sheard-off parts of the tape intruding the hydraulic circuit. The heat built-up of the motor winding must be checked via resistance tests for pumps with little flow/higher pressure if the fluid drops below the motor outline during operation. Coding Main dimensions (mm) Component part Illustration G D H h Suction screen (HAWE-No.) Fitting Straight fitting DIN 98 Mass (weight) g S 01 approx. H A 8 6 8 700 01 G+F No. 4 1/ -/8 DIN 90 N8 red 170 S 0 approx. H A 8 6 8 600 00 a G+F No. 4 1/ -/8 DIN 90 N8 red 170 S 0 A 8 7 8 700 01 /8 x40 170 S 04 approx. H A 109 0 600 00 G+F No. 41 1/ -/8 DIN 90 N4 /8 x80 60 S 0 A 89 0 600 00 /8 x60 40 S 06 G 1/ A 9 0 600 00 1/ x80 60 S 07 approx. H G 1/ A 7 0 600 00 1/ x60 0 S 10 approx. H M 10 x 1 6 8 700 00 Complete part, can t be dismantled! 100