Assembly and Maintenance manual according to regulation DIN 82079

Similar documents
Fundamentals for the regeneration of silica gel

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Multilayer Ceramic Chip Capacitors

Specification LW514. Drawn Approval Approval. Rev. 02 December 서식번호 : SSC-QP (Rev.00)

Specification LY530. Drawn Approval Approval. Rev. 08 December 서식번호 : SSC-QP (Rev.00)

Specification LR521. Drawn Approval Approval. Rev. 05 December 서식번호 : SSC-QP (Rev.00)

EVERLIGHT ELECTRONICS CO.,LTD.

Specification HW321A. Drawn Approval Approval. Rev November 서식번호 : SSC-QP (Rev.00)

Specification LW514. [Preliminary] CUSTOMER SSC. Rev. 00 October Document No. : SSC-QP (Rev.00)

Specification LY521. <080924> Rev. 0.3 Document No. : SSC-QP (Rev.00) Drawn Approval Approval. Rev. 00 December

Technical Datasheet. Lamp LEDs are effective in hot thermal. and humid condition. This high brightness. Features

Specification LR530 SSC CUSTOMER. Rev. 07 January acriche.com. Document No. : SSC-QP (Rev.00)

Specification LR530. Drawn Approval Approval. Rev. 08 December Document No. : SSC-QP (Rev.00)

DRAIN TRACING DYE RED E123

This document contains important information and must be read in its entirety. Edition: Previous Edition: /4

MATERIAL SAFETY DATA SHEET

Cobalt Chloride apollo

Specification LW520A

Technical Data Sheet Side View LEDs (Height 0.6mm)

EVERLIGHT ELECTRONICS CO., LTD.

Lewatit ASB 1 is supplied in the chloride form. Lewatit ASB 1 is also available in the hydroxide form, designated as Lewatit ASB 1 OH.

Manufacturing SPECIFICATION

SMD Top View LEDs EAPL4014WA1

SMD Side View LEDs LM2C/L7580S76/TR8-T

Technical Data Sheet - Preliminary Top View LEDs

开原亨泰精细化工厂. Kaiyuan Hengtai Fine Chemicals Factory. Material Safety Data Sheet. 4-Aminobutyric acid. Approved By IATA Regulation

EHP-A23/RGB33-P01/TR. Data Sheet. Materials. High Power LED 1W. 1 of 12 Release Date: :11:33.0 Expired Period: Forever

AME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg)

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

Power LED I TECHNICAL DATA

Lamp and Control Panel (Lamp Panel)

Exercise 4: Thin layer chromatography of organic compounds

Manufacturing SPECIFICATION

EVERLIGHT ELECTRONICS CO., LTD.

SMD Side View LEDs EAPL3810A17

SMD Side View LEDs LM2C/L7277SG6/TR8-T

Technical Data Sheet Silicon PIN Photodiode

Subminiature Transmissive Optical Sensor with Phototransistor Output

EHP-AX08EL/UB01H-P01/B7B8/F3

Thin Layer Chromatography

Specification SPW08F0D

Analysis of moist air unwatering by adsorbent in fluidized bed for thermal power stations units conservation

Methods of pollution control and waste management - laboratory. Adsorptive removal of volatile organic compounds from gases streams

SPECIFICATION PKG MODEL : LT3521CWHZ-HYS0. Contact Point Tel : Fax : Homepage :

Technical Data Sheet Top View LEDs

EVERLIGHT ELECTRONICS CO., LTD.

Operating Instructions for Digital Manometer. Model: MAN-SD

» decolorisation of sugar syrup (beet or cane), glycerine, grape must, fruit juices.

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

P8D137. Features. Applications. Power UV LED Series is designed for high current operation and high flux output applications. Super high Flux output

International Journal of Scientific Research and Modern Education (IJSRME) ISSN (Online): ( Volume I, Issue I,

Cold and freeze protection of blueberries in Florida. Dr. Dorota Z. Haman Agricultural and Biological Dept. University of Florida

DATA SHEET POSITIVE TEMPERATURE COEFFICIENT AC/DC POWER SUPPLY SMD0603 series

Contents Introduction Purpose Background What is a hazardous chemical? What is the GHS?...

0.5W White SPMWHT346EA3

P8D1 P8D1. Features. Applications. Power UV LED Series is designed for high current operation and high flux output applications.

Technical Data Sheet Mini Top View LEDs

SPECIFICATION WHITE SIDE VIEW LED. Customer. Approved by Approved by Approved by / / / Supplier. Drawn by Checked by Approved by / / /

BIOO FOOD AND FEED SAFETY. Histamine Enzymatic Assay Kit Manual. Catalog #: Reference #:

Product Description. Table of Contents. CLD-DS30 Rev 11. Product family data sheet

Elcometer 116C. Sling Hygrometer. Operating Instructions

Instruction Manual SEFRAM Thermal Camera

TOL-CFcPGKC. Lamp LED. Features. Dimensions. Chip Lens Color. Part Number. TOL-CFcPGKC AlGaInP Pure Green Water clear

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

Product Stewardship Summary

ETD Verification Kit

Conductive Polymer Capacitors

This document contains important information and must be read in its entirety. Edition: Previous Edition: /4

M90 20W. High Power LED PRODUCT DATASHEET. RoHS Compliant

Technical Data Sheet 1206 Package Phototransistor

Surface-mounting thermostats Series ATH

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Specification KWT803-S

Specification for Approval

Micro Volume QuEChERS kit

SEOUL SEMICONDUCTOR CO., LTD.

Low Inductance Ceramic Capacitor (LICC)

RoHS. Specification CUD8AF1C. 서식 Rev: 00

SPECIFICATIONS INFRARED LAMP LED

Technical Data Sheet. Pb Free. Specification GR101 SSC. Customer. Rev. 02 January 서식번호 : SSC- QP (Rev.0.

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

Z-POWER LED Series. Technical Datasheet for F50380 SEOUL SEMICONDUCTOR

CHARACTER TYPE LCD MODULE PVC160101PTN03 PRODUCT SPECIFICATIONS

Technical Data Sheet Silicon Planar PIN Photodiode

Surface-mounting Thermostats ATH Type Series

*These are the vinyl for MAX Bepop Cutting/printing machines. We have 100mm (4in) and 200mm(8in) width models available in North America.

EAPL4040WA1. SMD Side View LEDs PRELIMINARY. Features. Applications.

Metal Oxide Film Resistors Axial Connections Metal Oxide Film Resistors 1/4W, 5% Components

N) manual. Biomaster Operating manual

PRODUCT INFORMATION LEWATIT S 6328 A

DG Filters 2500 Series Refilling Instructions

SPECIFICATIONS INFRARED LAMP LED

Complex Compounds Background of Complex Compound Technology

Specification FAT801-S

SPECIFICATION. Product : Topview 3528 White SMD LED. Proposed By Checked By Checked By Checked By Approval

SPECIFICATION. - Contents -

Thermochemical Storage Technologies

ST/SG/AC.10/C.3/2012/75 ST/SG/AC.10/C.4/2012/11

Transcription:

Assembly and Maintenance manual according to regulation DIN 82079 ESORB Version 4.16 Part 1 Information to the manufacturer Giebel FilTec GmbH Carl-Zeiss-Str. 5 DE-74626 Bretzfeld-Schwabbach Tel. +49 (0) 7946 944401-0 Fax +49 (0) 7946 944401-29 Email info@giebel-adsorber.de Part 2 Adsorber overview es R 25, es R 50, es R 130 es R 450, es R 700 es V 550, es V 1100 es K 1100 Used materials: Polycarbonate, Aluminum, Stainless steel, Cardboard, Silica gel (Amorphous silicon dioxide), molecular sieve 4A (Type A zeolite NaA), molecular sieve 13X (Type X zeolite NaX) REACH note: No disclosure requirement according to Regulation (EC) No. 1907/2006. GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 Seite 1/8

Part 3 Build up and materials ESORB R Use Housing material Adsorbents Operating temp. Adsorber es R 25, es R 50, es R 130, es R 450, es R 700 Reusable Polycarbonate / Aluminum / Stainless steel Silica gel -40 C - +70 C ESORB V Use Housing material Adsorbents Operating temp. Adsorber es V 550, es V 1100 Reusable Polycarbonate / Aluminum Silica gel -40 C - +70 C ESORB K Use Housing material Adsorbents Operating temp. Adsorber es K 1100 Disposable Cardboard Silica gel -40 C - +50 C GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 Seite 2/8

Part 4 Technical data ESORB R es R 25 es R 50 es R 130 es R 450 es R 700 Total weight [kg] 0,06 0,10 0,24 0,65 0,94 Adsorbents [kg] 0,03 0,06 0,13 0,43 0,66 Height [mm] 66 75 96 117 131 Housing diameter [mm] 30 36 50 80 95 ESORB V es V 550 es V 1100 Total weight [kg] 0,7 1,2 Adsorbents [kg] 0,4 0,9 Height [mm] 28 49 Width [mm] 107 107 Length [mm] 271 271 ESORB K es K 1100 Total weight [kg] 1,0 Adsorbents [kg] 0,9 Height [mm] 42 Width [mm] 106 Length [mm] 265 GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 Seite 3/8

Part 5 Assembly and comissioning Proceed to assemble the entire adsorber as follows: 1. Turn off the system. 2. Unbox the adsorber and place it inside the system. Part 6 Maintenance Procedure for regeneration 1. Turn off the system. 2. Remove the adsorber 3. The ESORB can be regenerated as a complete unit. 4. Adjust the oven to 120 C circulating air and place the ESORB in the middle of the oven. 5. Once the silica gel is completely orange again, the ESORB is completely regenerated. 6. Be careful when removing it from the oven. The ESORB has become heated. 7. For cooling the ESORB should be packed airtight. 8. After complete cooling of the Adsorber, can be placed the adsorber back in the system. Procedure for refilling 1. Turn off the system. 2. Open the cover and empty the desiccant. 3. Fill in fresh desiccant. While filling in of the desiccant easily beat with a soft object (eg thenar) against the housing to compress the silica gel bulk. 4. Close the cover. 5. Place the adsorber back in the system. Procedure for disposable adsorbers 1. Turn off the system. 2. Remove the loaded adsorber. 3. Position the new adsorber in the system. GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 Seite 4/8

Part 7 Spare parts and storage ADSORBER es R 25 es R 50 es R 130 es R 450 es R 700 es V 550 es V 1100 DISPOSABLE ADSORBERTEIL es K 1100 es K 1100 SPARE PART FILLING A-SE99_OGM_2-5_0,25F A-SE99_OGM_2-5_0,25F A-SE99_OGM_2-5_1,0F A-SE99_OGM_2-5_1,0F A-SE99_OGM_2-5_2,0F A-SE99_OGM_2-5_1,0F A-SE99_OGM_2-5_2,0F Adsorber Build up - Adsorbents Pre-assembled in the housing and air tight packed. Spare part filling Content - Adsorbents Air tight packed. Order of replacement parts For a permanent operational readiness of the absorber, make sure that there is always a spare parts filling or a replacement adsorber in stock. The time until complete color change from orange to green and thus the service life of the adsorber will depend on several factors: - Relative humidity of the ambient air. - Temperature of the ambient air to be dried system. Storage of adsorbers All filled with desiccant modules are packaged airtight. Additionally the desiccant should be stored in dark and dry places at -10 C to +30 C to prevent damage. GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 Seite 5/8

Part 8 Regeneration and disposal New / Regenerated Observe color change Orange - Green Dispose / Regenerate New / Regenerated Observe color change Orange - Colorless Dispose / Regenerate New / Regenerated Observe color change Blue - Pink Dispose / Regenerate Regeneration In practice, the most common method used to regenerate silica gel is to increase the temperature. For desorption of water vapor from silica gel, the temperature level has to be above 100 C. Recommended for regeneration are temperatures between 150 C to 175 C. However, bearing in mind that the color indicator plated on to the silica gel can be damaged at these temperatures. Therefore, a regeneration temperature is specified at a level of 121 C for silica gel with color indicator and should not exceed 140 C. Disposal After completion of the useful life, the device should be disposed in accordance with the relevant statutory provisions. Metal and plastic parts should be separated and disposed. The loaded desiccant can be disposed of with household waste. Silica gel is not classified as dangerous according to European Union legislation (Regulation EC No. 1272/2008). According to EC Directives (67/548 / EEC and 1999/45 /EC) it does not require labeling. Silica gel does not belong to the health and environmentally hazardous substances. The desiccant silica gel is blue mixed with Cobalt (II) chloride hexahydrate and is classified in accordance with EC Directive (1999/45 / EC) as requiring labeling substance. This desiccant is one of the health and environmentally hazardous substances. When disposing the national laws must be observed. GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 Seite 6/8

Part 9 Risk and hazard analysis 1 Moist air in the closed system 1.1 Saturated desiccant If the desiccant is saturated, it can t longer adsorb moisture. Thus moist air is entering the system. See Maintenance Schedule Item 1 1.2 Oil on the desiccant If oil particles get into the adsorber, the particles close the pores of the desiccant. Thus no adsorption is possible. See Maintenance Schedule Item 1 1.3 Ambient temperature too high Does the peripheral temperature rises more than 80 C, the inflowing ambient air is dried only partially. 2 Adsorber housing is damaged 2.1 Material resistance When selecting an adsorber the ambient and operating conditions should be respected. See Maintenance Schedule Item 2 2.2 Vibrations of the system Excessive vibration of the system may damage the adsorber. See Maintenance Schedule Item 2 2.3 Temperature range The ambient and operating temperatures should not exceed the specified range or below, otherwise the adsorber can be damaged. See Maintenance Schedule Item 2 2.4 Improper handling In the choice of material of the absorber operating conditions (environmental factors and handling) should be considered. See Maintenance Schedule Item 2 GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 Seite 7/8

Part 10 Maintenance schedule Cycle 1. Visual inspection of the silica gel to saturation Inspect: By visual inspection of the adsorber the loading condition of the silica gel can be determined. The color orange indicates that the silica gel can adsorb more water and air is dehumidified. If the silica gel is fully saturated, the color changes to green. If oil particles are placed on the silica gel, the pores are closed and the adsorption capacity is reduced. Thus, the silica gel changes color more slowly and unevenly. Measure: The silica gel is removed from the adsorber. New Silica Gel is filled in again. For disposable adsorber the entire adsorber part is changed. Proceed as described in "Part 6 Maintenance". 2. Visual inspection of the adsorber Inspect: The adsorber is visually checked for damage. Damage may occur due to different environmental or operating conditions. Measure: If the adsorber is damaged, the damaged adsorber should be replaced to ensure full functionality. 3. Replace the silica gel or adsorber Inspect: The adsorber and the silica gel must be verified on their condition. Measure: Regardless of the result of the examination, it is recommended the silica gel to be replaced by the use of spare parts filling. With disposable adsorber the entire adsorber should be changed to ensure a smooth operation. Weekly Weekly Two-yearly GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 Seite 8/8