Fold optics path: an improvement for an atomic fountain

Similar documents
Miniaturized optical system for atomic fountain clock

CESIUM ATOMIC FOUNTAIN CLOCKS AT NMIJ

Tests of Cold Atom Clock in Orbit

Transportable optical clocks: Towards gravimetry based on the gravitational redshift

High sensitivity probe absorption technique for time-of-flight measurements on cold atoms

The near-infrared spectra and distribution of excited states of electrodeless discharge rubidium vapour lamps

Optimization and analysis of experimental parameters for. polarization gradient cooling in optical molasses

Construction of an absolute gravimeter using atom interferometry with cold 87. Rb atoms

PROGRESS TOWARDS CONSTRUCTION OF A FERMIONIC ATOMIC CLOCK FOR NASA S DEEP SPACE NETWORK

THE SPACE OPTICAL CLOCKS PROJECT

Microfibres for Quantum Optics. Dr Síle Nic Chormaic Quantum Optics Group

Laser cooling and trapping

PROGRESS TOWARDS CONSTRUCTION OF A FERMION ATOMIC CLOCK FOR NASA S DEEP SPACE NETWORK

Frequency stabilization of an extended cavity semiconductor diode laser for chirp cooling

Comparison with an uncertainty of between two primary frequency standards

Atomic filter based on stimulated Raman transition at the rubidium D1 line

Laser Cooling of Thulium Atoms

Uncertainty evaluation of the caesium fountain clock PTB-CSF2

SYRTE - IACI. AtoM Interferometry dual Gravi- GradiOmeter AMIGGO. from capability demonstrations in laboratory to space missions

A novel 2-D + magneto-optical trap configuration for cold atoms

Large Momentum Beamsplitter using Bloch Oscillations

Optical Lattice Clock with Neutral Mercury

A novel scheme for measuring the relative phase difference between S and P polarization in optically denser medium

Les Houches 2009: Metastable Helium Atom Laser

Compact Frequency Standard Based on an Intra-cavity Sample Cold Cesium Atoms

Demonstration of a Dual Alkali Rb/Cs Atomic Fountain Clock

Laser cooling of 173 Yb for isotope separation and precision hyperfine spectroscopy

New generation of a mobile primary frequency standard based on cold atoms

CESIUM ATOMIC FOUNTAIN CLOCKS AT NMIJ

Magnetic Field measurements with Csmagnetometers

Laser collimation of an atomic gallium beam

Optimization of transfer of laser-cooled atom cloud to a quadrupole magnetic trap

Ultracold atoms and molecules

Development of a compact Yb optical lattice clock

Laser Cooling and Trapping of Atoms

David McIntyre. A slow beam of laser cooled rubidium atoms will be used as the matter-wave source. The atom

Joshua Yablon Ye Wang Shih Tseng Dr. Selim Shahriar

arxiv: v1 [physics.atom-ph] 9 Feb 2009

Vector dark domain wall solitons in a fiber ring laser

Review the time-resolved scattering of a single photon by a single atom

arxiv: v2 [physics.atom-ph] 18 Jun 2013

A tunable corner-pumped Nd:YAG/YAG composite slab CW laser

Systematic Effects in Atomic Fountain Clocks

ABSTRACT. LIGHT SHIFT MEASUREMENTS OF COLD RUBIDIUM ATOMS USING RAMAN PUMP-PROBE SPECTROSCOPY Nathan Jon Souther

TOWARDS DEMONSTRATION OF A MOT-BASED CONTINUOUS COLD CS-BEAM ATOMIC CLOCK

Improvement of the Frequency Stability Below the Dick Limit With a Continuous Atomic Fountain Clock

Cold Atom Clocks on Earth and in Space Fundamental Tests and Applications. C. Salomon Laboratoire Kastler Brossel, Ecole Normale Supérieure, Paris

150 Zhang Sheng-Hai et al Vol. 12 doped fibre, and the two rings are coupled with each other by a coupler C 0. I pa and I pb are the pump intensities

HYPERFINE STRUCTURE CONSTANTS IN THE 102D3/2 AND 112D 3/2 STATES OF 85Rb M. GLOW

arxiv:physics/ v2 [physics.atom-ph] 12 Dec 2005

The Application of Four-Wave Mixing to Cold and Ultra-Cold. Atom Imaging

Development and Characterization of a Magneto-Optical Trap for Rubidium John M. Robinson, Yu Liu, David P. Shelton

Observing the Doppler Absorption of Rubidium Using a Tunable Laser Diode System

Saturation Absorption Spectroscopy of Rubidium Atom

The amazing story of Laser Cooling and Trapping

Primary Frequency Standards at NIST. S.R. Jefferts NIST Time and Frequency Division

Forca-G: A trapped atom interferometer for the measurement of short range forces

Internal magnetic field measurement in tokamak plasmas using a Zeeman polarimeter

EYLSA laser for atom cooling

Saturated Absorption Spectroscopy (Based on Teachspin manual)

Investigation of two-color magneto-optical trap with cesium 6S 1/2-6P 3/2-7S 1/2 ladder-type system

Citation for published version (APA): Mollema, A. K. (2008). Laser cooling, trapping and spectroscopy of calcium isotopes s.n.

OPTI 511L Fall Objectives:

Quantum Computation with Neutral Atoms Lectures 14-15

Towards compact transportable atom-interferometric inertial sensors

High stability laser source for cold atoms applications

1. Introduction. 2. New approaches

A Miniature Cold-Atom Frequency Standard

Double-distance propagation of Gaussian beams passing through a tilted cat-eye optical lens in a turbulent atmosphere

Comment on first accuracy evaluation of NIST-F2. Kurt Gibble Department of Physics, The Pennsylvania State University, University Park, PA 16802, USA

High Accuracy Strontium Ion Optical Clock

(Noise) correlations in optical lattices

Vector dark domain wall solitons in a fiber ring laser

Application of high-precision temperature-controlled FBG f ilter and light source self-calibration technique in the BOTDR sensor system

Atom-Based Test of the Equivalence Principle

Formation of Narrow Optical Resonance by Micrometer Thin Rb- Vapor Layer

Sensitivity limits of atom interferometry gravity gradiometers and strainmeters. Fiodor Sorrentino INFN Genova

Laser-Cooled Continuous Cs-Beam Master Oscillator

PHYSICAL REVIEW LETTERS

Optical pumping and the Zeeman Effect

Atomic Quantum Sensors and Fundamental Tests

SUB-NATURAL-WIDTH N-RESONANCES OBSERVED IN LARGE FREQUENCY INTERVAL

Limits of the separated-path Ramsey atom interferometer

Atomic fountain clocks

Compact frequency standard based on an intracavity sample of cold cesium atoms

Doppler-Free Spectroscopy of Hyperfine Zeeman Effects in Rubidium

Hyperfine structure and isotope shift measurements on 4d 10 1 S 0 4d 9 5p J = 1 transitions in Pd I using deep-uv cw laser spectroscopy

Single Atom wants to meet Single Photon Controlled Processes with Neutral Atoms

VIC Effect and Phase-Dependent Optical Properties of Five-Level K-Type Atoms Interacting with Coherent Laser Fields

Roger Ding. Dr. Daniel S. Elliott John Lorenz July 29, 2010

MEASUREMENT OF SHORT RANGE FORCES USING COLD ATOMS

arxiv:physics/ v1 [physics.atom-ph] 2 Jul 2004

Quantum Mechanica. Peter van der Straten Universiteit Utrecht. Peter van der Straten (Atom Optics) Quantum Mechanica January 15, / 22

Activities of Birmingham and the Hub

Supplementary Figures

Isotopic effect of Cl + 2 rovibronic spectra in the A X system

Advanced accelerometer/gradiometer concepts based on atom interferometry

Optical Lattice Clock with Spin-1/2 Ytterbium Atoms. Nathan D. Lemke

Overview of Frequency Metrology at NMIJ

Magneto-Optical Trap for Sodium Atoms from a Vapor Cell and Observation of Spatial Modes

Transcription:

Fold optics path: an improvement for an atomic fountain Wei Rong( ) a)b), Zhou Zi-Chao( ) a)b), Shi Chun-Yan( ) a)b), Zhao Jian-Bo( ) a)b), Li Tang( ) a)b), and Wang Yu-Zhu( ) a)b) a) Key Laboratory for Quantum Optics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China b) Centre for Cold Atom Physics, Chinese Academy of Sciences, Shanghai 201800, China (Received 4 January 2011; revised manuscript received 18 February 2011) A fold optical path is utilized to capture and launch atoms in the atomic fountain. This improved technique reduces the laser power needed by 60 percent, facilitates suppression of the laser power fluctuations, and leads to a more simple and stable system. Keywords: fold optics path, atomic fountain, laser power PACS: 95.55.Sh, 37.10.De DOI: 10.1088/1674-1056/20/8/089501 1. Introduction Atomic fountains (AFs) have broad applications in precision measurement fields. The uncertainty of the fountain clock has reached the 10 16 level, [1] while gravimeters and gravity gradiometers can measure the gravity and its grade at 10 9. [2] PHARAO (Projet d Horloge Atomique à Refroidissement d Atomes en Orbite), a cold space clock based on the fountain clock technique, will be set up in an international space station in 2013. [3,4] Its uncertainty is expected to be about 1 10 16. A similar plan is being executed in China. Since the first fountain for metrological use was developed at Observatoire de Paris/France, [5] the design of AFs has become the standard for almost all subsequently constructed fountain clocks. The setup includes magnetic optical trap (MOT)/optical molasses (OM) trap cold atoms, OM keep cooling, and optical moving molasses (OMM) launching atoms. Most AFs have the so-called (1,1,1) laser beam configuration, shown on the left side of Fig. 1, which consists of three orthogonal pairs of counter-propagating laser beams; three laser beam pairs are likewise arranged symmetrically around the vertical axis at an angle of 54.7 to the vertical. The six laser beams (SLBs) are divided into two groups: pointing upwards and downwards, respectively. At the MOT and OM stages, the SLBs keeps the same frequency ν; while at the OMM stage, the upward ones turn to ν + ν, and the downward ones change to ν ν to control the velocity of the atoms. Thus the atoms are launched along the vertical direction at a velocity of 3λ ν, where λ is the wavelength of the laser. Fig. 1. The (1,1,1) fountain launching structures of a SLB system (left) and a FOP system (right). AFs provide exciting results in their applications. However, they are strict at the environment and very difficult to run continuously due to the complex optical system, so, until now, there is no commercial AF working either as a clock or as a gravimeter, and this is the most important factor restricting its application in a space clock. Thus we substitute the SLBs with a fold optical path (FOP) scheme to achieve a more simple and stable system. Project supported by the National Natural Science Foundation of China (Grant No. 10974215) and the Science Foundation of State Key Laboratory of Precision Spectroscopy, East China Normal University. Corresponding author. E-mail: weirong@siom.ac.cn 2011 Chinese Physical Society and IOP Publishing Ltd http://www.iop.org/journals/cpb http://cpb.iphy.ac.cn 089501-1

2. Initial optical setup with SLB in our atomic fountain AFs of different research groups all have the SLB scheme as shown in Fig. 1 (left), with similar optical paths. The optical system of our AF initially has the standard SLB design, as shown in Fig. 2. A 1-W laser (TA100, TOPTICA Comp.) acts as a master laser with an output of 600-mW power for six capturinglaunching (CL) beams, state-selecting (SS) beam, and detecting beam, while a 50-mW laser (DL100, TOP- TICA Comp.) is used to supply repumping beams for the CL and the detecting stage. The frequencies of Chin. Phys. B Vol. 20, No. 8 (2011) 089501 both lasers are locked at a saturated absorption peak of the D2 line of 87 Rb isotope. Four acousto optical modulators (AOMs) are used to shift precisely the frequencies of light through a double-pass optical path. The lasers then split and transfer through fibres to a vacuum chamber. The power of each CL laser beam is about 25 mw with a diameter of 20 mm. The total power of the SS beam and the detecting beam is about 10 mw, and several microwatts are enough for the sum of the repumping beams of the fountain. So, the total power of the master laser should be greater than 250 mw. Fig. 2. Optical path of the atomic fountain at Shanghai Institute of Optics and Fine Mechanics (SIOM). MOT and OM require that the intensities of all counter-propagating laser beams are well balanced; the error should be less than 10%. The balance is difficult to maintain because much noise, mainly corresponding to fibres, makes the power of the output laser fluctuate. This is one of the principal elements affecting the continuous and reliable running of AFs, and is fatal for a cold atomic clock working in space because self-action, continuous running, reliability, and stability are the basic requirements. In addition to many passive actions to reduce the variations, active controllers have been used to provide feedback on the laser power s fluctuation. For example, at PHARAO, many piezoelctric ceramic (PZT) transducers were used to mount fibre coupling mirrors to control the output power by modulating the coupling efficiency. [4] And for fountains of the United States Naval Observatory (USNO), polarization-beam-splitters (PBS) are substituted with polarization-maintaining fibre splitters to reduce the fluctuations of laser power. Even so, a laser power stabilizing system is required for every set of fibre splitter system. [5] 3. Improving the optical setup with a fold optical path scheme We simplify the optics system of the fountain by using FOP to set up the CL zone, as shown on the 089501-2

right side of Fig. 1. Reflected by six pieces of 45 highreflecting (HR) mirrors, a laser beam input along the +x direction passes the centre three times successively along the +x direction, then the +y direction and the +z direction. Another counter-propagating laser beam is applied along the z direction; thus three orthogonal pairs of counter-propagating laser beams set up the CL zone. Adding a pair of anti-helmholtz coils along the y direction, the polarization of the three pairs of laser beams would fit the requirement of MOT once the two input beams have the right circular polarizations. It becomes a σ + σ OM when the coils are removed, and it changes to a normal lin lin OM when the beam input along the +x/ z direction is linearly polarized in the z/x direction, or when both are linearly polarized in the y direction. Obviously, when the two beams change the frequencies, respectively, to ν + ν and ν ν, they make a normal OMM. Thus, the structure fits the polarization requirements of MOT and σ + σ /lin lin OM; and the FOP system can substitute the normal SLB, with the six mirrors used instead of the four laser beams. The FOP structure, which has formerly been used in MOT and optical lattices, [6] fits all requirements at every stage of AF, including trapping, sub-doppler cooling, launching, and OMM-cooling. The FOP has great advantages over the SLB. First, the requirement for laser power decreases to a little more than 30% of the SLB system, viz, less than 100 mw. While the output of many diode lasers are more than 120 mw, this means that a single diode laser can work as a master laser without any amplifiers, which leads to a more simple and reliable system. Second, the FOP structure reduces the number of fibres, their accessories such as input coupler and output collimator, and other optical units, such as wave-plates and PBSs; thus, the optical system is greatly simplified, which also means a more stable system. Third, it is easier to control the fluctuations of the CL beams, because we now only need to adjust the diffracting efficiency of two launching-aoms (AOM3 and AOM4 in Fig. 2). However, FOP has to overcome two difficulties: one is precise control of the beam angle. For a 1-m launching-height AF, the anglular error of every beam should be less than 1 mrad; the alignment is difficult because a beam in the FOP scheme experiences six mirror reflections. We first adjust one beam (such as the upward beam) at one orientation (such as +x orientation), then add one set of three-mirror system and adjust another orientation (+y orientation), then add another set of three-mirror system and adjust the other orientation (+z orientation). With the help of auxiliary laser beams and auxiliary devices, such as a collimator and a diaphragm, we make sure that the accuracy of every step of adjustment is limited to less than 1 mrad. We then add another beam (downward beam), adjust inputting mounts to make two counterpropagating beams coincide (with angle/position error less than 0.1 mrad/0.5 mm respectively). Then we carry out atomic fountain experiments to optimize the FOP system by some fine adjustments, and lock every adjustable mount. The structure is probably not the best working model but it is very stable; and for a device, the stability is more important than the best working data. The other difficulty of realizing FOP is power balance of the counter-propagating beams. The FOP beam power is reduced by reflecting/transferring loss (RTL) of mirrors/windows, and optical scattering loss (OSL) of cold atom cloud; thus it is impossible to have the same power balance at three orthogonal directions. The RTL can be limited to an acceptable level by a fine film coating, for instance, if the loss of every window/mirror is less than 0.1%, which is attainable, the total unbalance due to RTL will be less than 1%. And in fact, as shown in the following, an RTL even as large as 5% is still acceptable for AF. The OSL is a complicated process, which affects the efficiencies of trapping, cooling, launching, and recooling. For AFs where the density of cold atoms is as low as (10 9 10 10 )/cm 3, the optical thickness is at the level of 0.01. Thus the OSL is limited, so the authors in Ref. [6] have not discussed it. The OSL is a fixed system error that reduces the number of signal atoms but causes no heating to the cold atoms, unlike the laser power fluctuations of SLBs. So although FOP cannot provide accurate power balance, it can work as well as a SLB, and no additional component is required to compensate for its leakage. 4. Testing the FOP in an atomic fountain clock We tested the FOP in an atomic fountain clock. The device, as shown in Fig. 3, consists of a CL chamber, an SS cavity, a detecting chamber, and an interacting chamber. A TE011 cylindrical microwave cavity with resonance frequency of 6.834 GHz and 089501-3

a quality factor of 18000 is set at the bottom of the interacting chamber. Two ion pumps set at the bottom and the top maintain a vacuum degree of 1 10 7 Pa. A rubidium cell connected with the CL chamber supplies the background gas of rubidium. The AF uses a low-density atom cloud for lower collision-frequency shift, so a low magnetic gradient (about 1.5 Gs cm 1 /0.8 Gs cm 1 (1 Gs=10 4 T) at axial/radial direction of coil pair) MOT is set. All three mounts are set on an L-shape aluminum plate, with the plate fixed to the vacuum chamber. By adjusting the mounts, the errors of the laser beams angles are limited to about 1 mrad, which are similar to the errors of earlier six-fibre systems. The reflection loss of the 45 mirrors system was measured as less than 1% for the light of s-polarization and about 2% for p-polarization. The transferring loss of windows was also measured, with every pair of windows at the three orthogonal directions, approximately 1%. Thus, assuming an ideal condition for power balance that the counter-propagating beams have equal power at the y direction, there is still an error of about 5% in the x and z directions. This limit can be improved by using better coating films for the mirrors and windows. Fig. 3. The scheme of rubidium AF at SIOM. We first use a SLB scheme. About 1 10 8 87 Rb atoms are trapped by MOT (500-ms loading time), cooled and launched by OM and OMM, tossed to its apogee and fall down, and detected by photodiodes. When the clock works, atoms go through stateselecting and microwave-interacting stages in their projectile motion. As given by the TOF signal, the atoms temperature was 4 µk, and the falling atom number was 4 10 6 populated on five magnetic sublevels of F = 2, 5 2 S 1/2, of which 8 10 5 were stateselected. The AF experiments of 85 Rb were also taken on the device; the temperature and the number of falling atoms were 2.5 µk and 1 10 7, respectively. We then replace four sets of fibre systems with two mirrors systems, each of which is composed of three 45 HR mirrors. Two of the mirrors are fixed on twodimensional mounts and the other is fixed on a mount. Fig. 4. TOF signals (solid line) and their Gauss fitting (dash line) of 87 Rb atoms (top) and 85 Rb atoms (bottom). Besides the changes mentioned above, every detail of the experiments is the same as that of the SLB system, that is, the same c-field, same maximum power with same diameter of laser beam, same time sequence, same launching height, and same detecting. The TOF signals of the two isotopes are shown in Fig. 4. The cold atoms were cooled down to a temperature of approximately 2.3 µk and 1.6 µk for 87 Rb and 85 Rb, respectively, and the number of falling atoms was 7 10 6 and 1.5 10 7. This means that more falling atoms are obtained with lower temperatures 089501-4

for both isotopes in the improved device. These results are remarkably better than those of the SLB but slightly poorer in comparison with the best results of the no-raman-side-cooling fountain. 1) We think that the improvement in the results is due to suppression of the power fluctuations of the laser beams by reducing the number of CL fibres from 6 to 2. 5. Conclusion The FOP has worked continuously at our fountain for about one and a half years, with no adjustments to the optical path during this period. The FOP scheme provides better results than SLB in our experiments. This scheme is not perfect because the CL beams cannot be exactly balanced at three directions due to various kinds of losses. However, it fits every requirement of fountains and is simpler. It reduces the laser power by two-thirds and greatly simplifies the optical path, thus making the optical system more stable and reliable. It is especially significant for cold space clocks because fewer units (especially laser source), less power supply, less control, and high stability are the prime design considerations for devices in space. Acknowledgment We acknowledge many discussions with Ming-Zhe Li of Xiamen University. References [1] Wynands and R Weyers S 2005 Metrologia 42 S64 [2] Peters A, Chung K Y and Chu S 2001 Metrologia 38 25 [3] Luiten A N 2001 Frequency Measurement and Control (Berlin, Heidelberg: Springer-Verlag) pp. 131 153 [4] Laurent Ph, Abgrall M, Jentsch Ch, Lemonde P, Santarelli G, Clairon A, Maksimovic I, Bize S, Salomon Ch, Blonde D, Vega J F, Grosjean O, Picard F, Saccoccio M, Chaubet M, Ladiette N, Guillet I, Zenone I, Delaroche Ch and Sirmain Ch 2006 Appl. Phys. B 84 683 [5] Maleki L 2009 Frequency Standards and Metrology, Proceedings of 7th Symposium (Singapore: World Scientific) pp. 308 313 [6] Rauschenbeutel A, Schadwinkel H, Gomer V and Meschede D 1998 Opt. Commun. 148 45 [7] Sortais Y, Bize S, Nicolas C, Clairon A, Salomon Ch and Williams C 2000 Phys. Rev. Lett. 85 3117 [8] He J, Qiu Y, Wang J, Wang J M, Wang Y H and Zhang T C 2008 Acta Phys. Sin. 57 6227 (in Chinese) 1) The temperature of the 85 Rb fountain is not indicated in the references. Because the temperature of OM cooling is related to the magnetic moment of atoms cooling state, F = 2 for 87 Rb, F = 3 for 85 Rb, and F = 4 for 133 Cs, we can infer that the temperature of 85 Rb should be higher than that of 133 Cs (0.7 µk according to the reference Salomon Ch, Dalibard J, Phillips W D, Clairon A and Guellati S 1990 Europhys. Lett. 12 683) and lower than that of 87 Rb. 089501-5