Real Time On-Site Odor and VOC Emission Measurements Using a znose

Similar documents
Odor Detection and Analysis using GC/SAW znose

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Edward J. Staples Page ONDCP INTERNATIONAL TECHNOLOTGY SYMPOSIUM March 8-10, 1999 Washington, DC

Vapor Intrusion Sampling Options: Performance Data for Canisters, Badges, and Sorbent Tubes for VOCs

Author. Abstract. Introduction

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

A Single Calibration for Waters and Soil Samples Performing EPA Method Anne Jurek Applications Chemist

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

An Innovative Field-Based Analytical Method For Low-Level Detection of Chlorinated Solvents in Groundwater and Soil Samples

Application Note S/SL

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

AUTONOMOUS, REAL TIME DETECTION OF 58 VOCS IN THE PANAMA CANAL

Chapter 3: Source Measurement Techniques

Implementation of Electronic Nose Technique In Explosives Detection

Tar measurement by the Solid Phase Adsorption (SPA) method

Multi-residue analysis of pesticides by GC-HRMS

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

TPH Methods and Measurements and Petroleum Vapor Intrusion (PVI) Risks

METHOD 3600B CLEANUP

A Micro-GC Based Chemical Analysis System

Application Note. Application Note 081 Innovative Cryogen-Free Ambient Air Monitoring in Compliance with US EPA Method TO-15. Abstract.

Application. Gas Chromatography February Introduction

STANDARD OPERATING PROCEDURES

UV3000. Accurate, precise, and portable ambient gas point analyzer

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

METHOD 3600C CLEANUP

GAW Expert Workshop VOC, C. Plass-Dülmer et al., FEHp-B 1

Chemistry Gas Chromatography: Separation of Volatile Organics

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

SIFT-MS. technology overview

Quarterly Groundwater Monitoring Report Third Quarter 2018

Analysis of BTEX in Natural Water with SPME

Determination of Benzene, Toluene, Ethylbenzene and Xylene in River Water by Solid-Phase Extraction and Gas Chromatography

Copyright 2009 PerkinElmer LAS and CARO Analytical Services, Inc.

A STUDY OF VOLATILE ORGANIC CARBON POLLUTION ON A UNIVERSITY CAMPUS DUE TO TRAFFIC

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

SELECTED ION FLOW TUBE MASS SPECTROMETRY. Interscience Expert Center: VIP Meeting 15 Sept. 2009

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

TO-17 Extending the Hydrocarbon Range above Naphthalene for Soil Vapor and Air Samples Using Automated

High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017

Disadvantage: Destructive Technique once analyzed by GC, the sample is lost

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Semi-continuous Benzene Monitoring in Burlington, Vermont July 2007-June 2008

Date 02/24/96 Page 1 Revison 4.0 OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY METHODS 8020/8015 (MODIFIED) GASOLINE RANGE ORGANICS (GRO)

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Spring 2010 updated March 24 Determination of Aromatics in Gasoline by Gas Chromatography- Mass Spectrometry: Comparison of Grades and Brands

Maximizing Sample Throughput In Purge And Trap Analysis

INNOVATIVE PRODUCTS, SUPERIOR SUPPORT. Presenter: Anne Jurek, Senior Applications Chemist, EST Analytical

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

TOC INCOMING LETTER OF TRANSMITTAL

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates

Luminescence transitions. Fluorescence spectroscopy

ASTM D5116 Emissions Test Report with CDPH SM V Loading Scenarios per Cradle to Cradle Standard v3.0 Sect. 5.8

MODELING, DESIGN AND EXPERIMENTAL CARACHTERIZATION OF MICRO-ELECTRO ELECTRO-MECHANICAL- SYSTEMS FOR GAS- CHROMATOGRAPHIC APPLICATIONS

Characterization of Odor & Taste Components Using Olfactory Detection and Solid Phase Microextraction GC-MS

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

A New Way to Extract Off-Flavor Compounds in the Aquatic Environment. Stir Bar Sorptive Extraction (SBSE)

C146-E209. Headspace Samplers. HS-20 Series

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

Gas Chromatography. Introduction

R.E.A.C.T. Roxbury Environmental Action CoaliTion P.O. Box 244 Ledgewood, N.J Website:

Date: March 6, 2008 RWDI Reference #: W B Pages (Including Cover):

DETERMINATION OF UPTAKE RATES FOR VOCs IN AMBIENT AIR BY USING AXIAL TYPE THERMAL DESORPTION PASSIVE TUBES

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

SUMMARY REPORT OF AIR MONITORING FOR LEED CERTIFICATION PHASE 2 SWANSFIELD ELEMENTARY SCHOOL 5610 CEDAR LANE COLUMBIA, MD PREPARED FOR:

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

VOC measurements in ambient air using Selected Ion Flow Tube Mass Spectrometry-automation and calibration considerations

Air Monitoring Sorbent Pens. For Environmental and IH Applications

Gas Chromatography. Chromatography Laboratory Course. Dr. Christian Jungnickel Chromatography Course GC September 2005

Characterising Volatile Organic Compounds from Sewer Emissions by Thermal Desorption coupled with Gas- Chromatography-Mass Spectrometry

TECHNICAL MEMORANDUM June 16, 2011

Analysis of Low Level Volatile Organic Compounds in Air Anne Jurek

Using a mini-gas Chromatograph (GC): Identifying Unknown Compounds

CHAPTER 6 GAS CHROMATOGRAPHY

Headspace Technology for GC and GC/MS: Features, benefits & applications

2B Technologies, Inc. An InDevR Company

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Automated Characterization of Compounds in Fire Debris Samples

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

EVALUATION OF A PID-BASED PORTABLE DETECTION SYSTEM FOR TVOC AS AN INDOOR POLLUTION ANALYZER

PAHs in Parking Lot Sealcoats. Performance Study. Asphalt Based. Coal Tar Sealcoat Sealcoat. Sealcoat. Scrapings. Asphalt Based.

The Application of Method TO-15 to Naphthalene Measurements in Indoor Air

Tar analysis by Solid Phase Adsorption (SPA) associated with Thermal Desorption (TD) and Gas Chromatography (GC) analysis

LAMBTON SCIENTIFIC (A Division of Technical Chemical Services Inc.)

Experimental Determination of Pyrolysis Products from Carbon/Resin Ablative Materials

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Analysis of Bakken Oil Samples

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT

Questions, Myths and Misconceptions about Using Photoionization Detectors

Dynatherm Thermal Desorption Systems

Chromatography Outline

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

DEHYDRATION OF ALCOHOLS-GAS CHROMATOGRAPHY

Transcription:

Real Time On-Site Odor and VOC Emission Measurements Using a znose Edward J. Staples, Electronic Sensor Technology, EST@ESTCAL.COM Remediation Site Description Remediation of contaminated soil from where coalfired power generators dating back to the mid-1800s once operated is a environmental priority for present day utility companies. Contaminated soil is excavated and removed to a remote location where hydrocarbons are removed and the clean soil returned for use as landfill. As a result of on-site excavation, hydrocarbons from coal tars are released into the air. Some are toxic and their concentration is regulated by the US EPA while others are just perceived by humans as noxious odors. Because of the negative impact of these emissions on the surrounding community, site managers need to monitor and minimize the release of volatile organic compounds and odors. Odor Chemistry Odor chemistry can be estimated from an analysis of soil samples by an independent laboratory. The names and concentration of the individual compounds contaminating the soil are then known. Physical properties of each compound, such as molecular weight or boiling point provide an estimate of the odor chemical signature. For a site contaminated with coal tar, the major VOC is naphthalene which has an odor threshold of 27 ppbv. Odor Measurement Method A new type of portable electronic nose, called the znose, can now perform on-site chemical measurements of VOC emissions and odors in near real time. This electronic nose separates and quantifies the hydrocarbon chemistry of odors in 10 seconds. Using a new solid-state detector, part per trillion sensitivity and universal selectivity is achieved. Performance of the technology has been validated by the US EPA s Environmental Technology Verification (ETV) program. Quality control of odor measurement methods is the same as used in laboratory testing. The instrument also uses an optional GPS receiver allowing an odor measurement to be linked to a specific time and location. On-site and off-site measurements of VOC emissions and odors provides real-time Figure 1- Excavation at remediation site involves removal of coal tar contaminated soil Figure 2- Laboratory analysis of contaminated soil provides a first order approximation of odor signature based upon molecular weight. Figure 3-Model 4100 znose ultra-high speed gas chromatograph information to site managers and is a useful tool for monitoring and controlling the impact of such emissions on the surrounding community. 1

To characterize only the odors from the soil, a 10 gallon bucket was half filled with soil and covered with aluminum foil. After waiting 5 minutes, headspace vapors were sampled and measured. A side-ported GC needle was attached to the inlet of the znose and inserted through the aluminum foil. One milliliter of headspace vapor was removed in 2 seconds and the concentrations of the individual chemicals within the odor measured in 10 seconds. Although 27 different compounds were separated, the major hydrocarbons and their concentrations were Benzene ( 9.5 ppm), Toluene (5.7 ppm), m,p-xylene (12.6 ppm), Naphthalene (17 ppm) and methyl-naphthalene (2.5 ppm). Interference or background odors were not a problem due to the high concentration of VOCs in the soil headspace vapors. Figure 4- Soil odors were tested in foil covered buckets. A characteristic odor signature for the site was obtained by measuring the headspace vapors. On-Site Odor Measurements A patented solid-state detector directly measured odor intensity Vs elution time from a GC column which was temperature programmed from 40 o C to 200 o C at rates as high as 20 o C per second. Sensitivity was controlled by (1) the temperature of the detector and (2) the amount of the vapor sampled. The concentration of chemical vapors from contaminated soil in a closed environment was high and odors could easily be evaluated using only a 1-milliliter vapor sample and a relatively hot 80 o C detector. Background odors from ambient air was not a factor at these high odor concentrations. Figure 5- Linear odor intensity (radial direction) vs elution time from GC column (angle) with start and stop time at 12 o clock position. Figure 6- Logarithmic odor intensity (radial direction- 100 to 1 span) vs elution time from GC column (angle) with start and stop time at 12 o clock position Olfactory images, called VaporPrints, are high-resolution 2-dimensional images based entirely upon the relative concentrations of the individual chemicals making up an odor. The image is a polar plot of the odor intensity (radial direction = sensor signal) and retention time (volatility). Complex odors can be recognized by their characteristic shapes based upon the odor s unique chemistry.. In effect the olfactory image allows the olfactory response to be transferred to a visual response. Humans and computers are well suited to the analysis and recognition of visual patterns. In addition, computer processing of olfactory images allows for identification, quantification and comparison of individual chemicals within the odor. 2

Odor Chemistry The solid-state detector measures the concentration of the odor chemicals directly and retention times for each of the chemicals detected are determined by identifying peaks in the GC column flux. Column flux is computed in real time by mathematically performing the time derivative of the detector signal. The result is a chromatogram spanning 10 seconds and representing the rate of adsorption and de-sorption of vapors onto the detector. The compounds are separated and identified by their unique retention times. Tabulating the retention times together with the individual and total concentration counts (cts) provides a quantitative measure of the chemicals within an odor. Figure 7- The derivative of odor intensity is a chromatogram used to determine chemical retention times. Using a 10-second analysis of the soil odor, 27 different compounds, their individual intensity, and the total of all intensities is tabulated. Automatic quantification and tabulation of individual chemicals within an odor is achieved by defining alarm bands centered on the individual retention times of each chemical peak. A narrow range in time is defined for each compound to be measured. Defining bands and alarm levels for specific chemicals within an odor results in a virtual array of chemical sensors specific to that odor. Using alarm bands, each peak is automatically Figure 8- Peak identification table listing identified compounds in RED together with their retention time and concentration counts. Figure 9- Top trace shows alarm bands (in RED) which are used to identify individual chemicals and compare their concentration (lower trace) to a user defined alarm level. identified, measured, and compared with a user defined alarm concentration level. Identified peaks are displayed in a peak list in RED together with their retention time and concentration counts. 3

Naphthalene Calibration A known vapor concentration of target chemicals (standard vapor) is used to calibrate the detector response. Injecting a container of a known volume with a known amount of a volatile chemicals creates a standard vapor. Calibration response factors can be single point or multi-point and are linked to specific instrument sensitivity settings. Variable sensitivity is achieved by changing the vapor sample size (sampling time) or the temperature of the detector. Using a one milliliter vapor sample of naphthalene standard vapor, the response factor is 0.5 counts per ppbv with an 80 o C detector. Cooling the detector to 20 o C increases the response factor to 7.5 cts/ppbv. Increasing the sample size to 15 milliliters gave a response factor of 300 cts/ppbv and a minimum detection level of 100 parts per trillion. Figure 11- Calibrating with standard vapor concentration. Figure 10- Naphthalene sensitivity Vs detector temperature with a 1-milliliter vapor sample. N-Alkane Calibration Often vapor standards for all chemicals at a site are not available. Many times too, the exact chemical name of a detected compound is unknown, yet it is still possible to identify the compound by indexing its retention time to that of a known chemical. Identification is most often done by indexing the unknown compound s retention time to that of the n- alkanes and then searching a library of indices for a match. An expandable library of chemical smells and indices, called Kovats indices, is part of znose software and is based upon the measured retention times from a n-alkane vapor standard. This is a convenient method of calibrating and tentatively identifying unknown odors in the field because it requires only one calibration standard for all compounds contained within the user library of smells and Kovats indices. Figure 12- System response to a vapor standard containing n- alkane vapors C7 to C14. Indexed compound retention times relative to that of an n-alkane is called Kovats Indices. 4

BTXX and BTEX Calibration Calibration vapor standards for benzene, toluene, ethylbenzene, and the m,p, and o-xylene were created by filling tedlar bags from gas canisters with certified concentrations of these compounds. One standard vapor, BTEX, contained 1 ppm of benzene, toluene, ethylbenzene, and o-xylene. Another standard vapor (BTXX) contained 1 ppm benzene, toluene, and 1 ppm of each of the three xylenes. Figure 13- Tedlar bags make constant concentration vapor standards for calibration of the znose. Figure 14- Expanded response to BTXX and BTX calibration vapors. Because m and p-xylene co-elute they cannot be separated easily from each other or from ethylbenzene. Two other compounds at this site, benzene and thiopene, also had identical retention times. However, because co-eluting compounds have similar response factors, total concentrations were measured and calibrated as total m-,p-xylene. Software allows the user to graphically select alarm bands, retention time, alarm levels or odor thresholds for selected chemicals within an odor. Peak identification and response factor data is stored in files containing all relevant calibration information for specific odors. Figure 15- Response and alarm window settings for 1 ppm BTEX. Figure 16- Peak identification file for BTEX standard vapors. Retention times are listed as Kovats indices and response factors are per ppm. Sensitivity to the BTXX and BTEX standard vapors was characterized by response factors in counts (cts) per ppm. For the lightest compound, benzene, the response factor was approximately 100 cts/ppm using a 15 milliliter vapor sample (30 second sample time) and a 20 o C detector. Using replicate measurement methods, the minimum detection level was approximately 300 ppb. Lowering the detector temperature to 0 o C increased sensitivity and lowered the minimum detection level for benzene to 40 ppbv. Response factors were proportionally larger for higher molecular weight compounds such as 3000 Cts/ppm for o-xylene and 30,000 cts/ppm for naphthalene. Retention times were expressed in seconds or as Kovats indices referenced to a file containing the system response to n-alkane vapors. 5

Outside Air Measurements Odors and their intensity within and surrounding the remediation site were measured in real time at several locations. One location, downwind from the site, was next to an entrance gate approximately 100 feet from where active excavation was being carried out. Ambient air was sampled by placing the znose on top of a 3 foot high concrete wall facing into the site. Figure 18- Downwind location (arrow) near active excavation of contaminated soil. Figure 17- Real time monitoring of site odors located at street entrance (downwind). Repetitive measurements of the site odors were taken every 80 seconds using a 30 second vapor preconcentration (15 milliliters) followed by a 10 second analysis time and 30 second recovery. Offset chromatograms in Figure 19 show a sequence of 10 analysis runs which began at approximately 9 am, shortly after active work on the site had started. Over a 50 minute period 35 measurements were taken. Figure 19- Consecutive measurements were taken every 80 seconds using a 30 second sample time, 10 second analysis, and 30 second recovery time. The prominent peak at 5.7 seconds is naphthalene. 6

Since site odor chemistry was dominated by naphthalene and methyl naphthalene these two compounds were used to monitor the odors being released from the site. Other, trace elements within the odor, are expected to vary in proportion to the concentration of these compounds. The intensity of site odors showed considerable short term variation in odor concentration and in the warm afternoon concentrations were higher than during the cooler morning hours. During a one hour period in the morning the concentration of naphthalene varied from 15 to 10 ppbv with an average of 11.4 ppbv. The varability of the odor concentration was reflected in a standard deviation of 43% for 35 consecutive measurements. Since the odor threshold for naphthalene is 27 ppbv, morning odors at this time and location might be undetectable. Concentration (ppbv) 25.0 20.0 15.0 10.0 5.0 70.0 Naphthalene Methylnaphthalene 0.0 0 10 20 30 40 50 Time (minutes-start 8:27 AM) Figure 20- Concentration of Naphthalene and Methyl Naphthalene at downwind location. Measurements taken at the same downwind location over a 10 minute period in the late afternoon indicated a substantial increase in the concentration of naphthalene odors. Following an upward trend, naphthalene concentrations as high as 60 ppbv, well above the odor threshold of 27 ppb, were measured. Ambient air within 10 feet of contaminated soil showed high odor concentration as expected. Soil piles arranged into open bins and awaiting treatment with chemical and biochemical odor reducing agents was tested over a 1 hour period in the late morning. Although the location was somewhat sheltered from winds, the concentration of naphthalene and methyl naphthalene still showed large short term variations and routinely exceeded the odor threshold. Concentration (ppbv) 60.0 50.0 40.0 30.0 20.0 10.0 Naphthalene Methylnaphthalene 0.0 0.00 2.00 4.00 6.00 8.00 10.00 Time (minutes-start 3:33 pm) Figure 21-Concentration of Naphthalene at downwind location in afternoon Concentration (ppbv) 40.0 35.0 30.0 25.0 20.0 15.0 10.0 Naphthalene Methylnaphthalene 5.0 Figure 22- Ambient odors were measured near soil being treated to reduce odors. 0.0 0 10 20 30 40 50 Time (minutes-start 9:25AM) Figure 23- Naphthalene odor concentration near soil bins. 7

Summary of Results A new type of electronic nose based upon ultra high-speed gas chromatography now allows the chemistry of odors to be qluantified in near real time with laboratory precision and accuracy. Over a 3 day period more than 800 odor measurements were performed at different locations in and around a soil remediation site contaminated with coal tar. A visual olfactory image based upon chemical measurements clearly indicated naphthalene was the dominant chemical compound in the site odor, although many other hydrocarbon elements were also present at lower concentrations. The sensitivity of the instrument allowed odor chemical concentrations at low ppt levels to be measured quickly and easily. Headspace vapors in foil-covered bucket samples of contaminated soil showed vapor concentrations at part per million levels. Chemical vapor concentrations of benzene (9.5 ppm ), toluene ( 5.7 ppm), m,p- Xylene ( 12.6 ppm ), naphthalene ( 17 ppm ), methyl naphthalene ( 2.5 ppm ), and numerous trace elements were measured and their relative concentrations defined the odor signature (VaporPrint ) of the site. Ambient air vapor concentrations in close proximity to contaminated soil (less than 1 foot) were in the low 1-10 ppm concentration range. Odor concentrations at a downwind location next to the site (approximately 200 feet from active excavation) were in the 10 to 50 ppb range. Upwind odor concentrations were much lower, typically in the part per trillion range. Replicate odor samples (30 second) taken at 80 second intervals showed considerable short term variability e.g. 43% standard deviation for 35 samples. Morning levels of naphthalene were slightly below odor threshold levels (27 ppbv) while afternoon levels were substantially higher, typically 60 ppbv downwind adjacent to the site. Because the electronic nose is based upon the science of gas chromatography, odor measurements can be easily confirmed and validated by independent laboratory measurements taken on quality control samples collected at the site. The ability to rapidly perform analytical measurements on-site in real time provides site managers with a cost effective new tool for monitoring volatile organic compounds and minimizing the impact of site odors on the surrounding community. 8