Mechanistic Insights into Chloride Ion Detection from the Atmospheric-Pressure Afterglow of an Argon Inductively Coupled Plasma

Similar documents
Supporting Information

TANDEM MASS SPECTROSCOPY

Automated Determination of PPQ Levels of Thorium in High Purity Copper

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

2,5-DIMETHOXY-4-IODOPHENETHYLAMINE Latest Revision: August 22, 2005

Encapsulation of enzyme in metal ion-surfactant nanocomposites for

National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD,USA. *

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Supporting information

Finnigan LCQ Advantage MAX

hydrideicp Hydride Generation System

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Mixing in Colliding, Ultrasonically Levitated Drops

M M e M M H M M H. Ion Sources

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Supporting Information

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Thermo Finnigan LTQ. Specifications

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

A Simple Fluorescein Derived Colorimetric and Fluorescent off - on Sensor For The Detection of Hypochlorite

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Laser desorption/ionization on the layer of graphene nanoparticles coupled with mass spectrometry for characterization of polymer

Biochemistry. Biochemical Techniques HPLC

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Electronic Supplementary Information (ESI)

Acrylamide (electrophoresis grade), AR grade captopril, L-cysteine, glutathione,

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Determination of Volatile Substances Proof of Food Adulteration

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

A biphasic oxidation of alcohols to aldehydes and ketones using a simplified packed-bed microreactor

The Importance of Field Strength in the Low Field Portion of a Differential Ion Mobility Spectrometry Waveform

Introduction to the Q Trap LC/MS/MS System

High-Throughput Semiquantitative Screening of Ambient Air Samples by ORS-ICP-MS and Integrated Sample Introduction System (ISIS) Application

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

*Correspondence to:

Accurate Sizing and Precise Counting of 10 nm Gold Nanoparticles using the Enhanced Sensitivity of the NexION 2000 ICP-MS

Ion-mobility mass spectrometry of polyoxometalate Keplerate clusters and their supramolecular assemblies

Accelerated Taylor State Plumes in SSX

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

OES - Optical Emission Spectrometer 2000

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Supporting Information

Supporting Information. Sweetened Swimming Pools and Hot Tubs

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

novaa 800 D Atomic Absorption Spectrometer

Sequential dynamic structuralisation by in situ production of

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Mass Spectrometry. Fundamental LC-MS. Electrospray Ionisation Instrumentation

Supporting information

VMA, HVA, 5-HIAA Urine LC-MS/MS Analysis Kit User Manual

Analyst Software. Automatic Optimization Tutorial

Department of Civil and Environmental Engineering, Stanford University, 473 Via Ortega, Stanford, California 94305, United States

Supporting information

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

HPLC-MS of the Initial Perfluorinated Surfactants and Shorter Chains:

Partial Energy Level Diagrams

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Mass Spectrometry in MCAL

Pickering emulsion engineering: Fabrication of materials with multiple cavities

MOUDI analysis of particle size distributions for ultrasonic spraying of salt solutions from an array of microscopic orifices

Chapter 2. Materials and Methods

Optimizing Analytical Performance in ICP-OES Applications

Heat-Shock Transformation of Escherichia coli in Nanolitre Droplets Formed in a Capillary-Composited Microfluidic Device

Supplemental Information

Scope: Materials: Labeled 1.5 ml or 2 ml Eppendorf tubes Appropriate pipette tips (see Table 1) Labeled LC vials

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase

Biodistributions of Gold Nanoparticles

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

Measurements of Dispersions (turbulent diffusion) Rates and Breaking up of Oil Droplets in Turbulent Flows

arxiv: v2 [physics.acc-ph] 21 Jun 2017

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Supporting Information. Graphene Oxide-Palladium Modified Ag-AgBr: A Novel Visible-Light- Responsive Photocatalyst for the Suzuki Coupling Reaction**

16 Malachite green 17 Leucomalachite green

Supporting Information for. Size-Dependent Oxidation State and CO Oxidation Activity of Tin

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS

ANALYTICAL REPORT 1 CUMYL-4CN-BINACA (C22H24N4O) 1-(4-cyanobutyl)-N-(1-methyl-1-phenylethyl)-1H-indazole-3-carboxamide

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Chapter 8. Online field-induced droplet ionization. mass spectrometry probes heterogeneous reaction

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Transcription:

Electronic Supplementary Material (ESI) for JAAS. This journal is The Royal Society of Chemistry 2018 Supplementary Information Mechanistic Insights into Chloride Ion Detection from the Atmospheric-Pressure Afterglow of an Argon Inductively Coupled Plasma Joseph E. Lesniewski, William P. McMahon, and Kaveh Jorabchi * Department of Chemistry, Georgetown University, Washington, DC * Corresponding author: kj256@georgetown.edu, phone: 2026872066 torch box Exhaust flow crossflow mixer (tee) tangential mixer 1.5 mm injector auxiliary plasma gas gas RF load coil 4.8 mm i.d. x 50 mm long SS reaction tube nebulizer 1.25 L/min argon injector with 20 µl loop LC pump 200 µl/min water 0.55 L/min argon 30 µl/min 200 µm sodium acetate in methanol makeup gas (0-1.0 L/min) solvent drain argon plasma exhaust velocity sensor air intake grid Ions to AP MS aluminum interface with 2.5 mm sampling orifice Figure S1. Schematic diagram of ICP-PARCI ion source. Note that diagram is not to scale. 1

Argon gas velocity and temperature measurements To measure the argon gas velocity at the center of the reaction tube, we utilized a particle tracking approach. Water droplets with a diameter of ~30 μm were created on demand and were entrained in the gas flow emerging from the reaction tube. The on-demand droplet generator consisted of a 0.5 ml polypropylene water reservoir connected through a 50-cm fused silica capillary (i.d.: 100 μm, o.d.: 360 μm, Polymicro Technologies, Phoenix, AZ, USA) to a borosilicate pulled glass tip (i.d.: 10 μm, ± 20%, WPI, Sarasota, FL, USA). The glass tip was encased by a ceramic piezoelectric tube (PI Ceramic, Lederhose, Germany) and was positioned face up and orthogonal to the reaction tube approximately 6 mm below the center of the tube. The piezoelectric actuator was driven by a trapezoidal pulse (amplitude: 55.6 V, rise time: 35 μs, duration: 80 μs, fall time: 60 μs) created by an arbitrary waveform generator (Dataman, Model: 530, Orange City, FL, USA) coupled to an amplifier (Trek, Model 2205, Lockport, New York, USA). Droplets were imaged using a triggered camera (Model DMK 42BUC03, The Imaging Source, LLC, Charlotte, NC) attached to the objective of a stereoscopic microscope. Two green LEDs synchronized with the droplet generation were used for illumination and droplet tracking. Timing events were controlled using a microprocessor (UNO, Arduino AG, Turin, Italy) at 20 Hz cycle time, starting with camera trigger followed by a 350 µs delay (camera ready time) before triggering the waveform generator for droplet production. A delayed pulser (PM 5715, Philips, Eindhoven, Netherlands) simultaneously triggered with the droplet generator provided the illumination and image capture pulses to LEDs (8.2 μs duration, 4 V pulse). The droplet trajectory was tracked by varying the delay time of the LED pulser. The droplets were ejected orthogonal to the gas flow and droplet entrainment was achieved 2 mm downstream of the tube evident from horizontal movement of the droplets with the gas flow. Once entrained, the droplets were captured at two LED firing times. The time difference between the two firings (1-6 ms) was measured using a digital oscilloscope (DS1102E, Rigol, Beaverton, OR). Five replicate images were captured for each LED firing time to provide an average location of the droplets for each setting. The droplet travel distance between the two LED firings was measured using Image J software 2

package in pixels and then converted to mm (3-6 mm) based on calibration using a calibrated microscope slide (model SK2, OptixCam, Roanoke, VA). The measurements provided relative standard deviations of 2-9% for the calculated velocity. The gas temperature at the end of the reaction tube was measured using a thermocouple positioned at the center of the tube. Sample preparation and data analysis All solvents used were LC-MS grade (Chromasolv, Sigma-Aldrich, St. Louis, MO). Chloramphenicol and sodium chloride were purchased from Sigma-Aldrich, St. Louis, MO. Analyte solutions were prepared by dissolving in methanol to concentrations of ~40-80 mm followed by dilution in water to final concentration of 25 μm chlorine in water. Ionization reagent solution was prepared using ACS grade sodium acetate (Fisher, Waltham, MA) by dissolving to a concentration of ~ 96 mm in methanol, followed by dilution to 200 μm in methanol. All selected ion chromatograms from flow injections were exported as text files, and then manually integrated using the trapezoid rule by selecting the beginning and end points of a baseline for each peak. The background spectra were centroided and extracted as.csv files for linear regression analyses of ion intensities. Figure S2. Correlation of background ion intensities with Cl - sensitivity indicated by r 2 values for linear regressions. All ions with > 100000 cps intensity were considered in regressions. 3

Figure S3. Background spectrum collected using soft ion sampling conditions (declustering potential of 10 V) at carrier gas flow rate of 2.4 SLPM and exhaust flow setting of 3.8 m/s. Compared to Figure 3, new clusters are detected, indicating formation of HCO 2H in these conditions. Further, [Na n(hco 2) n+1] - and [Na n(hco 2) nno 2] - clusters with n > 1 are enhanced relative to clusters with n=1 compared to the data in Figure 3, showing a higher extent of clustering with HCO 2Na. 4

5

Figure S4. a) MS spectrum of clusters generated by nano-esi from an aqueous solution of sodium chloride and sodium formate, b) MS/MS spectrum of [NaHCO 2Cl] - at collision energy of 12 ev showing Cl - as a major fragment ion, c) MS/MS spectrum of [NaHCO 2Cl] - at collision energy of 20 ev, indicating competitive generation of formate and chloride at higher collision energies, d) MS/MS spectrum of [Na 2(HCO 2) 2Cl] - at collision energy of 20 ev, showing loss of NaHCO 2 as the major fragmentation pathway from the second order cluster, e) MS/MS spectrum of [Na 3(HCO 2) 3Cl] - at collision energy of 20 ev, showing successive loss of NaHCO 2 as the major fragmentation pathway from the third order cluster. Experiments were performed using a Sciex API3000 instrument with a homebuilt nanospray source composed of a pulled glass capillary with a tip size of 3 μm. An aqueous solution of 1 mm NaHCO 2 and 100 μm NaCl was loaded into the capillary. A platinum wire was inserted into the capillary to apply -1100 V to the solution while a voltage of -200 V was applied to the curtain plate of the instrument using an external power supply. Nitrogen was used as CAD gas at an instrument setting of 4. 6