ISEmax CAM40/CAS40. Technical Information

Similar documents
ISEmax CAS40D. Technical Information

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

ph/redox Measurement CPM 280

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Application Your benefits

Chloromax CCS142D. Technical Information

Stamolys CA71HA. Technical Information

Operating Instructions ISEmax CAS40D

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Operating Instructions for Digital Manometer. Model: MAN-SD

Field IT 50T Series Transmitters

Pressure Transmitter ED 701

ED 701 General Industry Pressure Transmitter

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Conductivity sensor for hygienic applications

Pressure Measurement Single-range transmitters for general applications

ADI 2040 Process Analyzer

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Metso Concentration Measurement 3300

Residual Chlorine Monitor

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

Kjeltec 2300 Analyzer Unit

EX-EMERGENCY LIGHT FITTINGS

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Technical specification FLUXUS F502TE

One-hand ph/temperature measuring instrument

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

473 Dew Point Hygrometer

Installation guide 862 MIT / MIR

Compact ph Measuring Instruments With Pro Engineering

Automatic titrators, TitroMatic

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

PAA-ANALYZERS PRINCIPLE OF OPERATION

NH 3 -selective electrodes

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

Air velocity & IAQ measuring instruments

VK2 volume flow controller Overview

PRODUCT CATALOGUE PREssURE switch

Non-Contact Safety Systems CMS

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

473 Dew Point Hygrometer

Pressure transmitters for industrial applications MBS 32 and MBS 33

PHOENIX CONTACT - 04/2016. Features

Thermal Mass Flow Meter for Gases

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

VD1 CLC. Small Valves DIN-range with a higher k v -value

WATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Mercury Stack Monitor SM-4

Surface-mounting Thermostats ATH Type Series

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

Direct-operated 2/2-way solenoid valves Type EV210B

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

RoHS. Versatile. X g. X 2 e

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

Titration of a strong acid with a strong base with Cobra4

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

473-SHX Dew Point Mirror

OEM ph Competences. Solutions for ph OEM Applications in Liquid Analysis

Air velocity & IAQ measuring instruments

Z7A. Load cells. Special features. Data sheet. Wiring code

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

Capacitive Sensors. Contents

Presco AG. Standard Air Capacitor 10 nf / 2 kv. Type CL-0N10-K201. User's manual

Innovative Sustainable Technology

Calio-Therm NC Type Series Booklet

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

CHLORINE THEORY & MEASUREMENT

ION CHROMATOGRAPHY SYSTEM S 150

Linear measuring technology

Transcription:

Technical Information Online measurement of nutrient parameters Ion-selective electrode system for the continuous measurement of ammonium and nitrate Application The ion-selective electrode system works directly in the activated sludge basin of the sewage treatment plant without any sample conditioning or sample transportation. The system consists of a sensor, electrodes and a transmitter with display and operating elements and is mounted on the basin rim. Up to two ion-selective sensors simultaneously measure the nitrate and ammonium in the activated sludge basin. Your benefits Reliable, cost-saving unit: Nitrate and ammonium measured directly without the need for expensive sample conditioning Ion-selectivity prevents interference from nitrite Optional potassium and/or chloride measurement to compensate high concentrations of interference ions Low operating costs since no reagent used Versatile and flexible: Large measuring range 0.1-1000 mg/l NH 4 -N or 1-1000 mg/l NO 3 -N 4 current outputs and 5 relays, some user-configurable Easy-to-use and safe: Installed directly on the basin rim, no measuring container or sample-conveying pump required Low maintenance thanks to automatic flushing unit Membrane cap replacement every 6 months prolongs electrode service life TI427C/07/en/04.08 71072288

Measuring system Measuring principle At the heart of the ion-selective electrode (ISE) is a membrane that is selective for the ion to be measured. An ionophore is integrated into the membrane which facilitates the selective "migration" of a specific type of ion (e.g. nitrate or ammonium) to the electrode. As a result of the ion migration, a change in the charge occurs, causing an electrochemical potential that is proportional to the ion concentration to be created. The potential is measured against a reference electrode with a constant potential and converted to a substance-specific concentration using the Nernst equation. With the potentiometric measuring principle, the color and turbidity do not affect the measurement result. 1 A B 1 A B 1 2 3 4 5 Reference electrode Ion-selective electrode Inner metal lead Bridging electrolyte Junction Inner electrolyte Ion-selective membrane 2 4 3 General measuring principle of an ion-selective electrode 5 a0009231 Interference Depending on the selectivity of the ion-selective electrode vis-à-vis other ions (interference ions), and the concentration of these ions, such ions could also be interpreted as part of the measuring signal and thus cause measuring errors. When measuring in wastewater, the potassium ion which is chemically similar to the ammonium ion can cause higher measured values. The measured values for nitrate can be too high due to high concentrations of nitrite and chloride. To reduce measuring errors resulting from such cross-interference, the concentration of the potassium or chloride interference ion can be measured and compensated for with a suitable additional electrode. 2 Endress+Hauser

Measuring system A complete measuring system comprises: CAM40 transmitter CAS40 sensor Ion-selective electrode(s) for ammonium and/or nitrate Reference electrode Ion-selective electrode for compensating cross-interference ph glass electrode Optional Upright post with boom Wall retainer Weather protection cover - absolutely essential if mounting the transmitter outdoors! Compressor (if no compressed air is available on site) 1 2 4 3 Example: measuring system on basin rim 1 CAM40 transmitter 2 Upright post with weather protection cover 3 4 a0009239 CAS40 sensor Compressed air supply (cleaning) Input Measured variables Measuring ranges Depending on version: Ammonium Nitrate Potassium Chloride ph value Ammonium: 0.1 to 1000 mg/l (NH 4 -N) Nitrate: 0.1 to 1000 mg/l (NO 3 -N) Potassium: 1 to 1000 mg/l Chloride: 1 to 1000 mg/l Endress+Hauser 3

+ - + - + - + - + - + - + - + - + - Output Output signal Signal on alarm Load Relay output Switch output 4 x 0/4 to 20 ma, galvanically isolated Signal follows the measured value, fault can be freely programmed to a relay Max. 500 Ω 5 relays: All user-configurable If the optional compressor is used, a relay output is used to control it. Relay switching capacity: 230 V DC / 2 A Power supply Electrical connection Terminal Assignment L1 N 1 2 3 4 5 6 7 8 9 10 21 22 23 24 25 26 27 28 Power supply 230 V AC Relay LV 1 (Limit value 1) Relay LV 2 ( Limit value 2) Relay LV 3 ( Limit value 3) Relay LV 4 ( Limit value 4) Relay Error (Alarm relay) 0/4..20mA Analog outputs (Channel 1-4) L1, N 1, 2 3, 4 5, 6 7, 8 9, 10 21, 22 23, 24 25, 26 27, 28 PE, PE 230 V AC power supply Relay 1, max. 230 V AC, 2 A Relay 2, max. 230 V AC, 2 A Relay 3, max. 230 V AC, 2 A Relay 4, max. 230 V AC, 2 A Relay 5, max. 230 V AC, 2 A Analog output 1 Analog output 2 Analog output 3 Analog output 4 Protective earth Note! A compressor can optionally be controlled to terminals 9 and 10. In such instances, relay 5 is no longer available. PE PE Ground CAM40 wiring diagram a0009558-en Supply voltage Cable specification Electrode connection 100 to 240 V AC 3-wire, shielded cable, 10 m (33 ft) standard length GSA socket 4 Endress+Hauser

Performance characteristics Response time t 1) 90 Measured value resolution Maximum measured error Repeatability Ammonium: < 2 min. Nitrate: < 2 min. Potassium: < 2 min. Chloride: < 2 min. Ammonium, nitrate, potassium, chloride 0.1 to 99 mg/l: 0.01 mg/l 99 to 999 mg/l: 0.1 mg/l > 999 mg/l: 1 mg/l ± 5 % of the measured value ± 0.2 mg/l ±3 % of the display value Compensation Sensor Temperature ph Potassium 1) Chloride 1) Ammonium ph 8.3 to 10 10 to 1000 mg/l (ppm) - Nitrate - - 200 to mg/l (ppm) 2 to 40 C (36 to 100 F) Potassium - - - Chloride - - - 1) The fluctuations in concentration, not the absolute value, are the determining factor Max. operating life Automatic cleaning Membrane and electrolyte Use: 0.5 years Storage: 2 years Cleaning medium: Air Pressure: 2 to 3.5 bar (30 to 50 psi) Volume of air required per cleaning cycle: 3 to 4 l (0.8 to 1 US gal) Cleaning duration: 4 to 12 s Cleaning intervals (at T > 10 C (50 F)): Sewage treatment plant inlet: 30 min Sludge activation: 1 hr Sewage treatment plant outlet: 1 to 2 hr 1) For a change between 0.5 and 1 mmol/l in both directions, at 25 C (77 F) Endress+Hauser 5

Ambient temperature range Environment CAM40 transmitter: CAS40 sensor: -20 to 50 C (-4 to 120 F) 2 to 50 C (36 to 120 F) Storage temperature CAM40 + CAS40: 2 to 40 C (36 to 100 F) Protection class CAM40 transmitter: CAS40 sensor: IP 65 IP 68 Process temperature range Process 2 to 40 C (36 to 100 F) Process pressure ph value of the medium 400 mbar (160 inh 2 O) max. permitted overpressure Ammonium: ph 5 to 8.3 (without ph compensation) ph 5 to 10 (with ph compensation) Nitrate: ph 2 to 12 Potassium: ph 2 to 12 Chloride: ph 1 to 10 6 Endress+Hauser

Mechanical construction Dimensions CAM40 mm (inch) 256 (10.1) 122 (4.80) 112 (4.41) 216 (8.50) 157 (6.18) 70 (2.76) CAM40 dimensions a0009592 CAS40 12 (0.47) 64 (2.52) 6 (0.24) 107 (4.21) 360 (14.2) 107 (4.21) 43 (1.69) 660 (26.0) CAS40 dimensions 75 (2.95) mm (inch) a00095923 Weight CAM40 transmitter CAS40 sensor Approx. 2.6 kg (5.7 lbs) Approx. 2.8 kg (6.2 lbs) Material CAM40 transmitter: Aluminum, powder-coated CAS40 sensor: PVC, glass, polyethylene Wetted parts - Ammonium, nitrate, potassium electrode: PVC, plasticizer, silicone, nitrile - Chloride electrode: PVC, AgCl, AgS, silicone, nitrile - Reference electrode: Glass, PTFE, EPDM - ph electrode: Glass, EPDM Endress+Hauser 7

Electrode process connection Pg 13.5 Human interface Display and operating elements CAM40 ISEmax CAM40 display a0009551 Call up the menu functions Confirm, switch, scroll "Freeze" (hold) the display Measure + release the output signals Call up calibration routines Trigger manual cleaning Certificates and approvals 4 approval Declaration of conformity The product meets the requirements of the harmonized European standards. It thus complies with the legal requirements of the EC directives. The manufacturer confirms successful testing of the product by affixing the 4 symbol. 8 Endress+Hauser

Ordering information CAM40 product structure Power supply A 100-240 VAC; 50/60 Hz Signal output 1 4 x 0/4-20 ma CAM40- Complete order code CAS40 product structure Application A Aeration basin, nitrification, denitrification, with reference electrode B Inlet aeration basin, with ph compensation (only ammonium) Ion-selective parameter 1 Ammonium + nitrate 2 Ammonium 3 Nitrate Compensation electrode A None B Potassium (only ammonium) C Chloride (only nitrate) Cable length 1 10 m (33 ft) 9 Special version, to be specified CAS40- Complete order code Scope of delivery The scope of delivery comprises: 1 transmitter 1 sensor (version as per nameplate) 1 set of Brief Operating Instructions 1 set of Operating Instructions on CD-ROM Endress+Hauser 9

Accessories Note! In the following sections, you find the accessories available at the time of issue of this documentation. For information on accessories that are not listed here, please contact your responsible service. Installation accessories Immersion assembly holder CYH101 For ph, ORP, oxygen, conductivity assemblies, for oxygen and turbidity sensors and for ISEmax; With weather protection cover Ordering acc. to product structure (Technical Information TI092C/07/en) 1500 (59.06) 60 x 60 x 2 (2.36 x 2.36 x 0.08) max. 1400 (55.12) 1480 (58.27) Ř 35 x 1.5 (1.38 x 0.06) 120 (4.72) 950 (37.40) 450 (17.72) 4 x Ř12(0.42) 150 (5.91) mm (inch) Immersion assembly holder CYH101 a0010133 CYY102 universal post Square pipe for mounting transmitters Material: stainless steel 1.4301 (AISI 304) Order No. CYY102-A 1495 / 58.86 Square post 120 / 4.72 mm/inch 150 / 5.91 60x60/ 2.36 x 2.36 a0005742 10 Endress+Hauser

CYY101 weather protection cover for field devices, absolutely essential if operating the unit outdoors Material: stainless steel 1.4031 (AISI 304) Order No. CYY101-A 270 (10.6) 300 (11.8) 320 (12.6) mm (inch) Weather protection cover for field devices a0005741 Maintenance kits Electrodes Membrane kit 2 membrane caps Electrolyte Order numbers: Ammonium: 71072574 Nitrate: 71072575 Potassium: 71072576 Chloride: 71072577 Ion-selective electrode Electrode, complete Order numbers: Ammonium: 71072578 Nitrate: 71072580 Potassium: 71072581 Chloride: 71072582 Standard solution Standard solution 1 Ammonium nitrate, 1 molar Container size A 250 ml (8.45 fl.oz.) Transport documents 1 Standard documents 2 Incl. dangerous goods sheets 3 Safety data sheet Certificate A None B Manufacturer's certificate CAY40- Complete order code Air compressor Air compressor with housing 230 V, IP 65 Order no. 71072583 Endress+Hauser 11

Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com TI427C/07/en/04.08 Printed in Germany / FM+SGML 6.0 / POD