Altitude influence of elemental distribution in grass from Rila mountain. Dr. E. Nikolova, Dr. A. Artinyan, S. Nikolova INRNE - BAS XRF Laboratory

Similar documents
Overview of X-Ray Fluorescence Analysis

LAB REPORT ON XRF OF POTTERY SAMPLES By BIJOY KRISHNA HALDER Mohammad Arif Ishtiaque Shuvo Jie Hong

Quantitative XRF Analysis. algorithms and their practical use

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

X-Ray Fluorescence and Natural History

1 of 5 14/10/ :21

MS482 Materials Characterization ( 재료분석 ) Lecture Note 4: XRF

Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy

EDS User School. Principles of Electron Beam Microanalysis

Worldwide Open Proficiency Test for X Ray Fluorescence Laboratories PTXRFIAEA13. Determination of Major, Minor and Trace Elements in a Clay Sample

Summary of test results for Daya Bay rock samples. by Patrick Dobson Celia Tiemi Onishi Seiji Nakagawa

Application of total reflection X-ray fluorescence spectrometry for trace elemental analysis of rainwater

Guide to the Extended Step-Pyramid Periodic Table

Determination of the activity of radionuclides

In-Situ Analysis of Traces, Minor and Major Elements in Rocks and Soils with a Portable XRF Spectrometer*

SUPPORTING INFORMATION

FINDING A NEEDLE IN A HAYSTACK: PERFORMANCE EVALUATION OF PORTABLE XRF INSTRUMENTS FROM THREE MANUFACTURERS

This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract

OES - Optical Emission Spectrometer 2000

Unit 1 Part 2 Atomic Structure and The Periodic Table Introduction to the Periodic Table UNIT 1 ATOMIC STRUCTURE AND THE PERIODIC TABLE

ED(P)XRF: SCREENING ANALYSIS AND QUANTITATIVE ANALYSIS with POLARIZED

PARAMETERISATION OF FISSION NEUTRON SPECTRA (TRIGA REACTOR) FOR NEUTRON ACTIVATION WITHOUT THE USED OF STANDARD

OXEA - Online Elemental Analyzer

THE STRUCTURE OF ATOMS. ATOMS Atoms consist of a number of fundamental particles, the most important ones are...

How many grams of sodium metal is required to completely react with 2545 grams of chlorine gas?

CALCULATION OF THE DETECTOR-CONTRIBUTION TO ZIRCONIUM PEAKS IN EDXRF SPECTRA OBTAINED WITH A SI-DRIFT DETECTOR

Spin Cut-off Parameter of Nuclear Level Density and Effective Moment of Inertia

7) Applications of Nuclear Radiation in Science and Technique (1) Analytical applications (Radiometric titration)

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

Introduction to X-ray Photoelectron Spectroscopy (XPS) XPS which makes use of the photoelectric effect, was developed in the mid-1960

TRACE ELEMENT ANALYSIS USING A BENCHTOP TXRF- SPECTROMETER

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

8. Which of the following could be an isotope of chlorine? (A) 37 Cl 17 (B) 17 Cl 17 (C) 37 Cl 17 (D) 17 Cl 37.5 (E) 17 Cl 37

S.K. Sahoo 1 *, Z.S. Zunic 2, R. Kritsananuwat 1, H. Arae 1 and S. Mishra 1

ORBITAL DIAGRAM - A graphical representation of the quantum number "map" of electrons around an atom.

How many grams of sodium metal is required to completely react with 2545 grams of chlorine gas?

AMMS-100 Atmospheric Metal Monitoring System

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

Essential Chemistry for Biology

Course theme. Three hours of lab Complete E1 (Parts 1, 2, 3, 4, and 5B) Prepare discussion presentation Prepare team report.

Three hours of lab Complete E1 (Parts 1, 2, 3, 4, and 5B) Prepare discussion presentation Prepare team report. Course theme

- Atomic line spectra are UNIQUE to each element. They're like atomic "fingerprints".

ORBITAL DIAGRAM - A graphical representation of the quantum number "map" of electrons around an atom.

Last 4 Digits of USC ID:

Data report for elemental analysis of IMPROVE samples collected during April, May, June 2009 UC Davis Submitted June 18, 2010 SUMMARY

Analysis of Soil and Sewage Sludge in the Field with a Portable ED-XRF Spectrometer

Portable type TXRF analyzer: Ourstex 200TX

Measurements of K- shell production cross-section and fluorescence yield for Y element

Information on the test material EDS-TM002 and the BAM software package EDX Spectrometer Test for determination of the spectrometer performance

Atomic Physics. Chapter 6 X ray. Jinniu Hu 24/12/ /20/13

5 questions, 3 points each, 15 points total possible. 26 Fe Cu Ni Co Pd Ag Ru 101.

The Periodic Table. Periodic Properties. Can you explain this graph? Valence Electrons. Valence Electrons. Paramagnetism

Three hour lab. Chem : Sept Experiment 2 Session 2. Preparation Pre-lab prep and reading for E2, Parts 3-5

RADIOLOGICAL CHARACTERIZATION Laboratory Procedures

Introduction. Materials and Methods. Emilia L. Nikolova, Ralitsa D. Valcheva & Christo V. Angelov

X-ray Fluorescence Imaging Following Synchrotron Beam Excitation

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

ENERGY DISPERSIVE X-RAY ANALYSIS OF HUMAN HAIR Mohd Abdul Mujeeb 1 and Kahlid M Zafar 2

TRACE ELEMENT ANALYSIS OF DIAMOND BY LAM ICPMS: STANDARDISATION, RESULTS AND DIRECTIONS

Three hour lab. Chem : Feb Experiment 2 Session 2. Experiment 2 Session 2 Electrons and Solution Color

QUANTITATIVE Cs-137 DISTRIBUTIONS FROM AIRBORNE GAMMA RAY DATA

Multi Channel Analyzer (MCA) Analyzing a Gamma spectrum

CLASS TEST GRADE 11. PHYSICAL SCIENCES: CHEMISTRY Test 4: Matter and materials 1

Element Cube Project (x2)

Chapter 10: Modern Atomic Theory and the Periodic Table. How does atomic structure relate to the periodic table? 10.1 Electromagnetic Radiation

Laser Spectroscopy on Bunched Radioactive Ion Beams

Lewis dot structures for molecules

Environmental and Geological Applications of Instrumental Neutron Activation Analysis. Department Environmental, Earth, & Atmospheric Sciences

Topic 3: Periodicity OBJECTIVES FOR TODAY: Fall in love with the Periodic Table, Interpret trends in atomic radii, ionic radii, ionization energies &

Unique phenomena of tungsten associated with fusion reactor: uncertainties of stable hydrogen configuration tapped in tungsten vacancy

Analysis Repeatability of Trace and Major Elements in a Water Sample

Microsoft Excel Directions

Geogenic versus Anthropogenic Metals and Metalloids

-"l" also contributes ENERGY. Higher values for "l" mean the electron has higher energy.

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

CHEMICAL COMPOUNDS MOLECULAR COMPOUNDS

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

9/20/2017. Elements are Pure Substances that cannot be broken down into simpler substances by chemical change (contain Only One Type of Atom)

Advances in Field-Portable XRF

Standardless Analysis by XRF but I don t know what s in my sample!! Dr Colin Slater Applications Scientist, XRF Bruker UK Limited

The Periodic Table of the Elements

Atomic Emission Spectra. and. Flame Tests. Burlingame High School Chemistry

FUNDAMENTAL PARAMETER METHOD FOR THE LOW ENERGY REGION INCLUDING CASCADE EFFECT AND PHOTOELECTRON EXCITATION

Contamination of peat and moss samples 190 km from the Flin Flon Cu-Zn smelter, Canada: implications for exploration.

PART 1 Introduction to Theory of Solids

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

610B Final Exam Cover Page

Auger Electron Spectroscopy *

Solutions and Ions. Pure Substances

APPLICATION OF MICRO X-RAY FLUORESCENCE SPECTROMETRY FOR LOCALIZED AREA ANALYSIS OF BIOLOGICAL AND ENVIRONMENTAL MATERIALS

ICP-Mass Spectrometer

-"l" also contributes ENERGY. Higher values for "l" mean the electron has higher energy.

X-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination

Nuclear-physical methods for detecting pollutants and microelements in food

Introduction to LIBS COMMUNITY USER WORKSHOP ON PLANETARY LIBS (CHEMCAM) DATA. Sam Clegg and the ChemCam team

Nucleus. Electron Cloud

Transcription:

Altitude influence of elemental distribution in grass from Rila mountain Dr. E. Nikolova, Dr. A. Artinyan, S. Nikolova INRNE - BAS XRF Laboratory

I. Introduction The application of modern instrumental methods to the determination of trace elements in environmental samples has promoted the better understanding of the role of this elements. The acquainting with the concentrations of heavy metals and toxic elements gives us the opportunity for investigation of the distribution and dynamics of chemical elements accumulation in flora and fauna and their passing over the trophic chains and also for evaluation of antropogenic influence of toxic elements and technogenic transportation on the ecosystems. The energy dispersive X-ray fluorescence analysis is one of the well known analytical methods as a powerful analytical tool for the qualitative and quantitative determination of almost all chemical elements in a sample, first of all as a rapid and reliable method.

II. Principles and instrumentation In the EDXRF method, the sample, to be analysed is excited with electromagnetic radiation of sufficient energy. This leads to the ejection of electrons from the inner shells of the atoms present. Each vacancy is immediately filled up by an electron from an outer shell while the difference in energy between the two levels is generally released in the form of an X-ray. The energy of the emitted X-ray is characteristic for the ionised element, and from the intensities of the different characteristic X-rays in the spectrum, the concentration of the elements in the sample can be deduced. X- ray fluorescence requires the source of radiation, the sample, which is irradiated and the detection system. With these the spectrometer is complete and through computer support all necessary calculations to transfer the intensities into concentrations and to identify the elements can be carried out from the measured spectrum. The power of this analytical instrument is due to the energy dispersive detector, the simultaneous determination of all elements. Information is obtained rapidly and no element, which is present can be overlooked. For standard excitation the lower detection limits are in the range μg/g (ppm). This is sufficient for many applications, but for some environmental problems these detection levels are too high. Recent developments for solving this problems are the application of total reflection and the introduction of synchrotron radiation sources for excitation

III. Sample and sample preparation The best procedure for sample preparation is to leave the sample as it is, but in many cases this is unrealistic. Any process to transfer the sample on a substrate or preparation needs safe treatment so as to guarantee that the processed sample is representative of the original. Homogeneity of the sample and contamination free sample preparation are the basic requirements in each technique. In particular, environmental samples, which we investigate in our lab are soils, sediments, leaves, needles, grass, moss, lichen, fishes, small mammals. In order to minimize the error from sample preparation we use only a drying and grinding procedure. An amount of about 300g from the sample is dried in microwave oven for 10 minutes. Then this sample is ground to a mesh side about 0.1mm and homogenised. An amount of 30g from the plants and biological samples and 50g from soils and sediments are pressed in a specialised sample carrier. Particular difficulties occurs, when very small amount from the sample are available, as in the case of internal tissue of fishes and small mammals. In this case an approximation curve intensity versus sample mass is established for normalisation of obtained characteristic X-ray intensities

IV. Instrumentation Two spectrometric systems are available in our lab for X-ray analyses. The first one is equipped with Si(Li) detector with 12.5 μm Be window and 180 ev energy resolution at 5.9 kev Mn-K α line. The data are acquired with a multi-channel analyzer, interfaced to a personal computer, that applies specialized software for spectra processing. This system is combined with an exciting head, based on an annular source Am 241 with activity 3.7 GBq and three types of secondary targets in two excitation mode - transition and reflection in order to select the desired exciting energy - namely the characteristic line of Mo (17.44 kev), Sn (25.19 kev) and Dy (45.98 kev). For determination of heavy elements, which are essential for biology the system use the Dy secondary target, that allows detection of elements down to the Z=56. This construction permits the measurement of great number of elements with a high sensitivity by achieving the desirable experimental conditions of low background level and at a high count rate.

The second system is equipped specially for light element analysis with Si(Li) detector with 12.5 μm Be window and 160 ev energy resolution for 5.9 kev Mn-K α line. An exciting head, especially designed for low Z elements determination is equipped with three radionuclide sources Fe 55. In the case of this construction, the distances source-sample and sample-detector are greatly reduced and optimized, which allows elements with atomic number Z=13 to 25 to be analyzed. During the measurements of zoological samples, traces from very essential for biology elements like Cu, Zn, Mn, Pb were occurred. To become higher sensitivity and lower detection limit for these elements another exciting source Pu 238 is built in the same head (fig. 3). It s energy of 13.613 kev is very suitable for exciting of elements with Z=22 to 35. In this way the all range of Z from 13 to 82 is covered and each sample can be measured with this three kind of excitation.

V. Spectrum processing To obtain results the measured spectra must be evaluated as to line energies and line intensities, with only the net intensity used for quantification. The correctness with which the peak areas for the analyzed elements are determined is of crucial importance in order to obtain accurate and reliable results for their amounts. Different methods for energy-dispersive X-ray spectra processing have been investigated and now in software package three different methods for peak area determination are included - namely total peak area, linear and non-linear least square algorithms, resolution enhancement procedures.

VI. Calibration A set of international standards, such as lake sediment IAEA SL-1, soil IAEA Soil-7, air born dust BCR-128. These standards are applied for soil calibration curve. A Belgian standard FCG-15 is applied for verification of these curves. The obtained results are in good agreement with the reference concentrations for the standard. For the exciting head with Fe 55 sources a set from different plant standards - Bowen s kale, IAEA V10-Hay, orchard leaves were used for matrix correction, because of higher amounts of the light element concentration - K, Ca, Cl etc. For the estimation of the sensitivity curves for animal spacies three other IAEA s standards (horse kidney, coppepod and fish flash) were applied. Once the correlation between intensity and concentrations is found, comparable sample types, measured under same conditions can be quantified. At trace levels the XRF techniques provides a direct proportionality between analyte line net intensity and its concentration. This holds for homogenous sample of a given matrix and either of constant or infinite thickness, i.e. of constant mass. In this way, when the net intensities of the analytical elements are found the unknown elemental concentrations can be calculated.

4 Sensitivity Pu source pure elements Rank 15 Eqn 2050 y=a+bx+cx^2+d/x r^2=0.99406923 DF Adj r^2=0.99110385 FitStdErr=0.12298965 Fstat=502.83681 a=18.80427 b=-2.6309988 c=0.14616033 d=-39.93728 4 3 3 Sensitivity (cps/ppm) 2 1 0-1 2 1 0-1 Sensitivity (cps/ppm) -2-2 -3 2 4 6 8 10 Energy (kev) -3

VII. Accuracy, errors and detection limits The total error of the analysis consists of many errors, which can be provocate by: measurement of the intensity, reproducibility of the sample preparation and conversion of intensity into concentration. The total relative error of a 7-10% is estimated during the calibration procedure as a standard deviation error of a previously prepared and analyzed standards with known element concentrations. The detection limits (DL) (the minimum amount, that can be analyzed) are determined by the sensitivity and by the background in the X-ray spectrum. The use of three kinds of excitation give us the opportunity to reach detection limit levels, which are enough for environmental control and monitoring purposes. With a new technique of total reflection XRF a drastically decrease of this values is possible.

SAMPLE CODE Element Z trvbli3 trvbor3 trvmcr3 trvbel4 trvmus4 Value +/- Value +/- Value +/- Value +/- Value +/- Al % Si % 17760 300 15330 350 P (ppm) 3250 300 3190 300 3080 300 5330 600 1700 150 S (ppm) 2760 250 3980 500 1260 100 Cl (ppm) 5110 250 5050 100 3950 100 3860 100 1700 100 K (ppm) 20950 480 23270 550 14270 350 27270 600 4640 150 Ca (ppm) 3475 30 4010 40 4210 40 8020 350 4500 40 Ti (ppm) 47 2 31 2 V (ppm) Cr (ppm) Mn (ppm) 46 4 248 8 159 7 139 7 55 5 Fe (ppm) 104 2 108 4 104 5 221 10 1167 58 Ni (ppm) 9 1 4 1 3 1 Cu (ppm) 4 1 Zn (ppm) 19 1 27 1 34 3 24 2 31 3 Ga (ppm) As (ppm) 15 2 20 3 Se (ppm) Br (ppm) 12 2 50 5 12 2 81 7 10 2 Rb (ppm) 71 2 168 8 86 4 19 2 4 1 Sr (ppm) 42 6 29 2 40 3 20 2 Y (ppm) Zr (ppm) 2 1 3 1 7 1 Nb (ppm) Mo (ppm) Ag (ppm) 1 1 Cd (ppm) 1 1 Cs (ppm) 3 1 Ba (ppm) 10 2 8 2 25 2 25 3 59 6 Hg (ppm) Pb (ppm) 5 2 5 2 Weight,g 7,69 15,26 16 15,2 17 Sample grass grass grass grass grass

S Cl Ca K 700 Dolna banja' 01 700 Dolna banja ' 02 750 Gen. Kovachevo' 02 800 Belchin' 04 880 Jauoruda' 02 1000 Beli iskar' 03 1000 M. Carkwa' 03 1140 Predela' 02 1300 Borovetz' 03 1400 Jundova' 02 1500 Redjepsko ez.' 01 1800 Semkovo' 01 1800 Malowica' 01 2920 Karaalanica' 01 2925 Mussala' 04 30000 25000 20000 15000 10000 5000 0 Grass Altitude(m), Area S Cl Ca K Concentration (ppm)

Ti Fe Mn Zn 700 Dolna banja' 01 700 Dolna banja ' 02 750 Gen. Kovachevo' 02 800 Belchin' 04 880 Jauoruda' 02 1000 Beli iskar' 03 1000 M. Carkwa' 03 1140 Predela' 02 1300 Borovetz' 03 1400 Jundova' 02 1500 Redjepsko ez.' 01 1800 Semkovo' 01 1800 Malowica' 01 2920 Karaalanica' 01 2925 Mussala' 04 800 700 600 500 400 300 200 100 0 Area Grass Ti Zn Mn Fe Concentration (ppm)

Zr Br Sr Rb 700 Dolna banja' 01 700 Dolna banja ' 02 750 Gen. Kovachevo' 02 800 Belchin' 04 880 Jauoruda' 02 1000 Beli iskar' 03 1000 M. Carkwa' 03 1140 Predela' 02 1300 Borovetz' 03 1400 Jundova' 02 1500 Redjepsko ez.' 01 1800 Semkovo' 01 1800 Malowica' 01 2920 Karaalanica' 01 2925 Mussala' 04 300 250 200 150 100 50 0 Area Grass Zr Br Rb Sr Concentration (ppm)

Ba Pb 700 Dolna banja' 01 700 Dolna banja ' 02 750 Gen. Kovachevo' 02 800 Belchin' 04 880 Jauoruda' 02 1000 Beli iskar' 03 1000 M. Carkwa' 03 1140 Predela' 02 1300 Borovetz' 03 1400 Jundova' 02 1500 Redjepsko ez.' 01 1800 Semkovo' 01 1800 Malowica' 01 2920 Karaalanica' 01 2925 Mussala' 04 60 50 40 30 20 10 0 Area Grass Ba Pb Concentration (ppm)

VIII. Conclusions EDXRF is capable of detecting traces of almost all elements of the periodic system. The method enables fast, non-destructive direct analyses without lengthy sample pre-treatment and is well suited for environmental investigations because of its sensitivity and lower detection limits achieved and also because of the rapid and simultaneous acquisition of information on the elements present. The software available permits quantitative determination of trace elements within a short time once the calibration function for the system is established. The results for grass samples from different regions show, that noun specific altitude dependence is present. The regions near human objects like Maljowitza hotels and Moussala station collect more Fe contents, probably due to the metal scrap from building construction.