Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Similar documents
A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

of mass spectrometry

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Fast, Effective XPS Point Analysis of Metal Components

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

HILIC Method Development in a Few Simple Steps

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

for XPS surface analysis

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

MetWorks Metabolite Identification Software

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Monitoring Protein PEGylation with Ion Exchange Chromatography

Introduction to Fourier Transform Infrared Spectroscopy

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Nanoparticle Analysis: An Upcoming Challenge for Environmental Analysis

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Utility of the Charge Detector in Ion Chromatography Applications

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Introduction to Fourier Transform Infrared Spectroscopy

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Thermo Scientific GasBench II

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Charged Aerosol Detection and Evaporative Light Scattering Detection Fundamental Differences Affecting Analytical Performance

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Automated and accurate component detection using reference mass spectra

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Thermo Scientific. Anion-Exchange Column

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Analysis of Silicone Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Enhancement of Linearity and Response in Charged Aerosol Detection

Dionex IonPac AS28-Fast-4µm column

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

A Platform Method for Pharmaceutical Counterion Analysis by HPLC

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Determination of Nanoparticle Sizeand Number Concentration using the npquant Evaluation Module for Qtegra ISDS. The world leader in serving science

Key Words Q Exactive Focus, Orbitrap, veterinary drugs, small molecule HRAM quantitation, small molecule HRAM screening, UHPLC, vdia

Determination of trace anions in concentrated hydrofluoric acid

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

Transcription:

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS Daniel Kutscher, 1 Jörg Bettmer, 2 Torsten Lindemann, 1 Shona McSheehy-Ducos, 1 Lothar Rottmann 1 1 Thermo Fisher Scientific, Germany 2 University of Oviedo, Department for Physical and Analytical Chemistry, Oviedo, Spain

Overview Purpose: Demonstrate the potential of FFF-ICP-MS and sp-icp-ms for the characterization of nanoparticles. Methods: FFF was coupled to ICP-Q-MS, with liquid flows driven using an inert ion chromatography system. For sp-icp-ms, samples were directly aspirated. Results: FFF was shown to separate Au nanoparticles based on their diameters. sp-icp-ms was used to determine the average diameter of Ag nanoparticles. Introduction The need for nanoparticle (NP) characterization has exploded in recent years due the ever increasing use of engineered nanoparticles (EN) in various industries and the consequent studies that investigate the environmental and consumer risk. Of the methods developed with this goal in mind, Field Flow Fractionation (FFF) coupled to ICP-MS has proven to be one of the most promising. FFF has a separation principle based on the differing mobilities of different particle sizes in a laminar liquid flow. Smaller particles flow faster through the channel, enabling a separation based on size. FFF is compatible for particle sizes in the low nm to low µm range and is thus perfectly suited to NP separation. Another promising approach for NP characterization is sp-icp-ms. Through direct analysis of an appropriately diluted solution containing NPs, the NPs can be counted. If the NPs consist of just one element, the peak height is proportional to the size of the NP, and the frequency of individual signals can be used to determine the NP concentration. Although both strategies benefit from the high sensitivity of ICP-MS detection, the single particle approach limit of particle size detection is actually governed by signal-tonoise ratio. The more sensitive an instrument, the smaller the particle it can detect. Methods Sample Preparation In general NP standards were diluted in water and sonicated for 5 to 15 minutes just prior to analysis. 2 Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Field Flow Fractionation A Wyatt Technology Eclipse equipped with a short channel (SC) was coupled to the Thermo Scientific icap Qc ICP-MS (Fig. 1). Mobile phase was delivered to the Eclipse chassis using a Thermo Scientific ICS-5000 HPIC System and injections were performed using the sample loop of the ICS-5000 AS-AP Autosampler. The Eclipse chassis splits the flow appropriately with a series of specially configured valves. The FFF membrane used and the separation parameters are shown in Table 1. FIGURE 1. Wyatt Technology Eclipse AF4 with SC coupled to a Thermo Scientific icap Qc ICP-MS. TABLE 1. Field Flow Fractionation Conditions. Gold NPs Membrane 10 kd RC* Mobile Phase Water Injection vol. (µl) 20 Detector flow (ml/min) 0.5 Focus flow (ml/min) 1.5 FFF protocol Time Vx Elution 1 0 Inject 1 0 Focus and Inject 5 0 Focus 1 0 Elution 5 1.5 Elution 15 1.5 Elution 5 0.5 Elution and Inject 10 0 *RC Regenerated Cellulose Thermo Scientific Poster Note PN43200_E_06/14S 3

sp-icp-ms An icap Qc ICP-MS was used for all sp-icp-ms determinations. Ag NP of different sizes were prepared and analyzed. All solutions were prepared in 2 mmol L -1 ammonium citrate. A tap water sample was sourced locally, and diluted 3:1 in ammonium citrate before analysis. Data Analysis Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) software was used throughout for icap Qc ICP-MS control and all data acquisition. The embedded plug-in for the Thermo Scientific Dionex Chromeleon Chromatography Data System Software was used to drive the Wyatt Eclipse and ICS-5000 HPIC system in a single method. Eclipse ISIS software (Intelligent Separation Improvement Software) was used to optimize the FFF separation conditions. Results Field Flow Fractionation Certified gold NPs with 30 nm (NIST 8012) and 60 nm (NIST 8013) diameters were used to evaluate the NP separation potential of FFF. Table 1 summarizes the channel, membrane and conditions used. Figure 2 shows elution profiles of 30 nm and 60 nm gold NPs. Optimization of separation conditions based on detector flow (Vd), cross flow (Vx) and cross flow gradient were performed using ISIS, a dedicated software for predicting separation based on the input of flow-rates and channel geometry. 30 nm 60 nm FIGURE 2. 197 Au FFF-ICP-MS fractograms of 30 nm and 60 nm gold NPs. 4 Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Single Particle ICP-MS sp-icp-ms requires the measurement of single particle events (SPE) in a time resolved analysis. The underlying principle of sp-icp-ms lies in the fact that the size of the NP is directly proportional to the intensity of the SPE. This is presented in figure 4, where the smaller NPs (20 and 40 nm) generate lower intensity SPEs than the larger NPs (60 and 100 nm). For sp-icp-ms, the sample needs to be diluted so that only a suitable number of particles per volume is directly aspirated into the plasma. Data from fast scanning across a single isotope in a predetermined time window (e.g. 5 ms dwell time for 60 s) and is exported into a Microsoft Office spreadsheet to calculate particle size and differentiate between actual NP s and background signals. The correlation between dwell time and particle events is illustrated in figure 3. A typical nanoparticle event has a duration of 300µs. Only one nanoparticle event should be monitored per data point (A). Short dwell times lead to incomplete registration of particle events (underestimation of particle size, B). Long dwell times lead to registration of two (or more) particle events (overestimation of particle size, C). A B C Intensity [cts] dwell time ~ 300 µs dwell time Time [ms] FIGURE 3: Relation between single particle event and dwell time. For sp-icp-ms, the instrumental detection limit is expressed as a nanoparticle size, that can no longer be discriminated against the instrumental background. It is therefore dependent on the instrument s detection sensitivity, not on the dilution factor of the sample! Thermo Scientific Poster Note PN43200_E_06/14S 5

Figure 4 shows the resulting time resolved analysis for four different sized Ag nanoparticles, each solution containing the same total amount of Ag (5 ng kg -1 ): FIGURE 4. Time resolved measurements of Ag nanoparticles with size 20 nm, 40 nm, 60nm and 100 nm (top left to bottom right) @ total Ag amount of 5 ng kg -1 The determined NP size is plotted against the theoretical value in Figure 5. Both values are in good agreement. The determined LoD is approximately 20 nm for Ag NP s. 120 Nanoparticle size theroretical 100 80 60 40 20 R² = 0.9948 0 0 20 40 60 80 100 120 Nanoparticle Size measured Measured Size Linear (Measured Size) FIGURE 5: Correlation of theoretical and measured nanoparticle size for Ag NP s. As a final proof of the suitability of the method, locally sourced tap water was diluted 3:1 in 2 mmol L -1 ammonium citrate and was analyzed without and after addition of Ag NP s (40 nm, 5 ng kg -1 total Ag), see figure 6. 6 Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

FIGURE 6. Analysis of unspiked tap water (top) and spiked tap water (bottom) with sp-icp-ms. The determined NP size in tap water was 41 ± 1 nm and is in excellent agreement with the expected value. Conclusion Both FFF-ICP-MS and sp-icp-ms bring analytical advantages to the characterization of NPs and act as complementary techniques. The integrated FFF-ICP-MS package is fully automated with bidirectional control and emergency shut-off features. The completely metal free FFF/IC system operates with a single pump and offers a switch option that allows the user to quickly change from FFF to IC. The high base sensitivity and low backgrounds of the icap Qc ICP-MS offer a particular advantage in sp-icp-ms. References 1. P. Krystek et al. J Anal. At. Spectrom. 26 (2011); 1701-1721. Acknowledgements We would like to thank the team at Wyatt Technology Europe, Dernbach, Germany, for both technical and application support. www.thermoscientific.com 2014 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. Wyatt Technology is a trademark of Wyatt Technology Corporation, registered in some countries. Eclipe and ISIS are used in trade by Wyatt Technology Corporation. NIST is a Service Mark of National Institute of Standards and Technology AGENCY OF THE GOVERNMENT UNITED STATES. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Africa +43 1 333 50 34 0 Australia +61 3 9757 4300 Austria +43 810 282 206 Belgium +32 53 73 42 41 Canada +1 800 530 8447 China 800 810 5118 (free call domestic) 400 650 5118 Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland +358 9 3291 0200 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9494 Italy +39 02 950 591 Japan +81 45 453 9100 Latin America +1 561 688 8700 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Norway +46 8 556 468 00 Russia/CIS +43 1 333 50 34 0 Thermo Fisher Scientific, San Jose, CA USA is ISO 9001:2008 Certified. Singapore +65 6289 1190 Spain +34 914 845 965 Sweden +46 8 556 468 00 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752 PN43200_E 06/14S