NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NU VISTA WD, INC. SERIES/MODEL: Malibu 250 T TYPE: Fixed

Similar documents
NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NORTH EAST WINDOWS USA, INC.

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

THERMAL PERFORMANCE TEST REPORT

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

Report No: NCTL NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15

AIR-INS inc. 1320, boul. Lionel-Boulet, Varennes (Quebec) J3X 1P7 Tél. : (450) Fax : (450)

Report No: NCTL S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 07/14/15. Test Specimen

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION. SERIES/MODEL: 4000 TYPE: Fixed

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 7400 TYPE: Fixed

ASTM C THERMAL PERFORMANCE TEST REPORT. Rendered to: UNIVERSAL PULTRUSIONS, LLC. PRODUCT: Fiberglass Door Slab

NFRC SOLAR HEAT GAIN COEFFICIENT TEST REPORT. Rendered to: CLEAR FOCUS IMAGING

NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: INTERNATIONAL ARCHITECTURAL PRODUCTS, INC. DBA: UNITED STATES ALUMINUM

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: TUBELITE, INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CMI ARCHITECTURAL PRODUCTS, INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

Simulation Report (Revised) Rendered To: Showcase Custom Vinyl Windows 1002 Olde Towne Drive Irving, TX 75061

SIMULATION TEST REPORT NCTL E0A0

PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. PRODUCT: SUN TUNNEL Domes TYPES: Acrylic and Polycarbonate

WINDOW SIMULATION REPORT

PERFORMANCE TEST REPORT. Rendered to: WORLDWIDE DOOR COMPONENTS, INC. PRODUCTS: PVC and Composite Door Jamb Material

Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods 1

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

Determination of installed thermal resistance into a roof of TRISO-SUPER 12 BOOST R

TEST METHOD FOR THERMAL TRANSMITTANCE AND AIR INFILTRATION OF GARAGE DOORS

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

Reflectec Thermal Fabric & Reflectec Fiberboard

Determination of thermal transmittance of window (test title)

THE EFFECTS OF CALORIMETER TILT ON THE INWARD-FLOWING FRACTION OF ABSORBED SOLAR RADIATION IN A VENETIAN BLIND

Winter Night. Thermos 6mm Outdoors # #

QIRT th International Conference on Quantitative InfraRed Thermography

Window air permeability measurement, watertightness and resistance to wind load (designation of the test)

TEST OF MEASURED SOLAR HEAT GAIN VARIATION WITH RESPECT TO TEST SPECIMEN TILT

Solar Energy Cooking with the Sun

CAE 463/524 Building Enclosure Design Fall 2012

ISO INTERNATIONAL STANDARD

National Fenestration Rating Council. Incorporated. NFRC [E0A1] Procedure for Determining Fenestration Product Condensation Resistance Values

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

TEST REPORT. Page 1 of 11

Determining of Thermal Conductivity Coefficient of Pressed Straw (Name of test)

Sound Absorption Test Intertek. kraft paper softwall + softblock modular system. m o l o d e s i g n, l t d

Order No. G Date: September 8, 2010 REPORT NO CRT-001 TEST OF SMF/PAPI SYSTEM RENDERED TO

TEST REPORT. Test Method : See the attached sheets.

PERFORMANCE EVALUATION OF REFLECTIVE COATINGS ON ROOFTOP UNITS

17.01 Maxblock Sunshades by Tubelite Description

Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM. Project/Customer: Profilex HM spacer

Calculating the heat transfer coefficient of frame profiles with internal cavities

Department of Mechanical Engineering ME 96. Free and Forced Convection Experiment. Revised: 25 April Introduction

THERMAL TRANSMITTANCE OF MULTI-LAYER GLAZING WITH ULTRATHIN INTERNAL PARTITIONS. Agnieszka A. Lechowska 1, Jacek A. Schnotale 1

REPORT NUMBER: GZU-001 ORIGINAL ISSUE DATE:

METHOD OF IN-SITU MEASUREMENT OF THERMAL INSULATION PERFORMANCE OF BUILDING ELEMENTS USING INFRARED CAMERA

Building Envelope Requirements Overview Page 3-4

FG 623 Window Wall. Optional Features Integrates with standard Kawneer windows

CAE 331/513 Building Science Fall 2016

UNIT FOUR SOLAR COLLECTORS

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

IBHS Roof Aging Program Data and Condition Summary for 2015

DEVELOPMENT OF THE MEASURING SYSTEM FOR ANALYSING THE THERMAL PROPERTIES OF CLOTHING

Guide Specifications Section

CALIBRATION REPORT FOR THERMOHYDROMETER

Integrated Circuits Thermal Test Method Environment Conditions - Natural Convection (Still Air)

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

Solar Flat Plate Thermal Collector

ISO INTERNATIONAL STANDARD. Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

TEST METHOD FOR STILL- AND FORCED-AIR JUNCTION-TO- AMBIENT THERMAL RESISTANCE MEASUREMENTS OF INTEGRATED CIRCUIT PACKAGES

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES

BACK TO BASICS: PIPE INSULATION

5. AN INTRODUCTION TO BUILDING PHYSICS

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

DeFelsko PosiTector Dew Point Meter with Anemometer (DPMA)

Cat# LED Linear High Bay 100W

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

PRODUCT DATA SHEET. Eagle Eye Outdoor LED Module 5700K. RoHS Compliant. CUSTOMER :. DATE : REV : Rev. 2.0.

Vincent Barraud SOPREMA BASICS OF THERMAL INSULATION

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

Use of Phase-Change Materials to Enhance the Thermal Performance of Building Insulations

THE IMPLICATION OF ENERGY EFFICIENT BUILDING ENVELOPE DETAILS FOR ICE AND SNOW FORMATION PATTERNS ON BUILDINGS

Introduction to Infrared Thermometry

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Photometric Test Report

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada

PAPER 2 THEORY QUESTIONS

Standard Practices for Air Speed Calibration Testing

REPORT NUMBER: GZU -001 ORIGINAL ISSUE DATE:

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS

Effect of Installing a Curved Venetian Blind to the Glass Window on Heat Transmission

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

Effective Thermal Conductivity of High Temperature Insulations for Reusable Launch Vehicles

Uncertainty Workshop: Overview of uncertainty factors in HTGHPs

LED Entryway Light RoHS

Report No.: HZ p. (Lumens) Stabilization Time CRI (K)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Tick the box next to those resources for which the Sun is also the source of energy.

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Initial study - draft

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

Transcription:

NFRC 102-201 THERMAL PERFORMANCE TEST REPORT Rendered to: NU VISTA WD, INC. SERIES/MODEL: Malibu 250 T TYPE: Fixed Summary of Results Standardized Thermal Transmittance (U-Factor) 0.39 Unit Size: 7" x 59" (119 mm x 199 mm) (Model Size) Layer 1: 1/" SN68 (e=0.039*, #2) Gap: 0.52" A1-D: Aluminum Spacer 100% Air* Layer 2: 1/" Clear Reference must be made to Report No., dated 06/29/16 for complete test specimen description and data. 252 E. Jensen Avenue Fresno, CA 93706 www.archtest.com www.intertek.com/building p. 559.233.8705 f. 717.76.129

NFRC 102-201 THERMAL PERFORMANCE TEST REPORT Rendered to: NU VISTA WD, INC. 6163 Mesa Ave Los Angeles, California 9002 Report Number: Test Date: Report Date: 05/26/16 06/29/16 Test Sample Identification: Series/Model: Malibu 250 T Type: Fixed Overall Size: 7" x 59" (119 mm x 199 mm) (Model Size) NFRC Standard Size: 7.2" x 59.1" (1200 mm wide x 1500 mm high) Test Sample Submitted by: Test Sample Submitted for: Nu Vista WD, Inc. - Tijauana, Baja California, Mexico Validation for Initial Certification (Production Line Unit) & Plant Qualification Test Procedure: U-Factor tests were performed in a Guarded Hot Box in accordance with NFRC 102-201, Procedure for Measuring the Steady-State Thermal Transmittance of Fenestration Systems. Test Results Summary: Standardized U-factor (Ust): 0.39 Btu/hr ft 2 F (CTS Method) 252 E. Jensen Avenue Fresno, CA 93706 www.archtest.com www.intertek.com/building p. 559.233.8705 f. 717.76.129

Page 2 of 8 Test Sample Description: Frame: Material: Size: Daylight Opening: Exterior Color: Interior Color: Corner Joinery: AT (0.27"): Aluminum with Thermal Breaks - All Members 7" x 59" (Model Size) 2-1/2" x 5-1/2" Glazing Method: Exterior Grey Exterior Finish: Paint Grey Interior Finish: Paint Mitered / Corner Keys / Sealed Glazing Information: Layer 1: 1/" SN68 (e=0.039*, #2) Gap: 0.52" A1-D: Aluminum Spacer Layer 2: 1/" Clear Gas Fill Method: N/A* 100% Air* *Stated per Client/Manufacturer N/A Non-Applicable www.archtest.com www.intertek.com/building

Page 3 of 8 Test Sample Description: (Continued) Weatherstripping: Description No weatherstripping. Quantity Location Hardware: Description Quantity Location No hardware. Drainage: Drainage Method Size Quantity Location Weephole 1" x 1/8" 2 Sill face. Glazing bead. Weep notch 1" 2 Second sill leg from the exterior. www.archtest.com www.intertek.com/building

Page of 8 Thermal Transmittance (U-factor) Measured Test Data Heat Flows 1. Total Measured Input into Metering Box (Qtotal) 679.85 Btu/hr 2. Surround Panel Heat Flow (Qsp) 10.8 Btu/hr 3. Surround Panel Thickness.00 inches. Surround Panel Conductance 5. Metering Box Wall Heat Flow (Qmb) 0.063 Btu/hr ft 2 F -2.30 Btu/hr 6. EMF vs Heat Flow Equation (equivalent information) 0.0119*EMF + 0.000 7. Flanking Loss Heat Flow (Qfl) 27.75 Btu/hr 8. Net Specimen Heat Loss (Qs) 59.92 Btu/hr Areas 1. Test Specimen Projected Area (As) 19.26 ft 2 2. Test Specimen Interior Total (3-D) Surface Area (Ah) 19.96 ft 2 3. Test Specimen Exterior Total (3-D) Surface Area (Ac) 21.02 ft 2. Metering Box Opening Area (Amb) 53.8 ft 2 5. Metering Box Baffle Area (Ab1) 52.23 ft 2 6. Surround Panel Interior Exposed Area (Asp) 3.22 ft 2 Test Conditions 1. Average Metering Room Air Temperature (t h ) 69.81 F 2. Average Cold Side Air Temperature (t c ) -0.52 F 3. Average Guard/Environmental Air Temperature 72.00 F. Metering Room Average Relative Humidity 13.71 % 5. Metering Room Maximum Relative Humidity 13.8 % 6. Metering Room Minimum Relative Humidity 13.57 % 7. Measured Cold Side Wind Velocity (Perpendicular Flow) 12.66 mph 8. Measured Warm Side Wind Velocity (Parallel Flow) 0.0 mph 9. Measured Static Pressure Difference Across Test Specimen 0.00" ± 0.0"H 2 O Average Surface Temperatures 1. Metering Room Surround Panel 66.81 F 2. Cold Side Surround Panel 0.87 F Results 1. Thermal Transmittance of Test Specimen (U s ) 2. Standardized Thermal Transmittance of Test Specimen (U st ) 0.1 0.39 Btu/hr ft 2 F Btu/hr ft 2 F www.archtest.com www.intertek.com/building

Page 5 of 8 Thermal Transmittance (U-factor) Calculated Test Data CTS Method 1. Warm Side Emittance of Glass (e1) 0.8 2. Cold Side Emittance of Glass 0.8 3. Warm Side Frame Emittance* 0.90. Cold Side Frame Emittance* 0.90 5. Warm Side Sash/Panel/Vent Emittance* N/A 6. Cold Side Sash/Panel/Vent Emittance* N/A 7. Warm Side Baffle Emittance (eb1) 0.92 8. Cold Side Baffle Emittance (eb2) N/A 9. Equivalent Warm Side Surface Temperature 9.81 F 10. Equivalent Cold Side Surface Temperature.80 F 11. Warm Side Baffle Surface Temperature 68.88 F 12. Cold Side Baffle Surface Temperature N/A F 13. Measured Warm Side Surface Conductance (h h ) 1.3 Btu/hr ft 2 F 1. Measured Cold Side Surface Conductance (hc) 5.37 Btu/hr ft 2 F 15. Test Specimen Thermal Conductance (Cs) 0.63 Btu/hr ft 2 F 16. Convection Coefficient (Kc) 0.3 Btu/(hr ft 2 F 1.25 ) 17. Radiative Test Specimen Heat Flow (Qr1) 275.29 Btu/hr 18. Conductive Test Specimen Heat Flow (Qc1) 27.63 Btu/hr 19. Radiative Heat Flux of Test Specimen (qr1) 1.30 Btu/hr ft 2 F 20. Convective Heat Flux of Test Specimen (qc1) 1.26 Btu/hr ft 2 F 21. Standardized Warm Side Surface Conductance (hsth) 1.23 Btu/hr ft 2 F 22. Standardized Cold Side Surface Conductance (hstc) 5.28 Btu/hr ft 2 F 23. Standardized Thermal Transmittance (Ust) 0.39 Btu/hr ft 2 F Test Duration 1. The environmental systems were started at 11:19 hours, 05/25/16. 2. The test parameters were considered stable for two consecutive four hour test periods from 22:11 hours, 05/25/16 to 06:11 hours, 05/26/16. 3. The thermal performance test results were derived from 02:11 hours, 05/26/16 to 06:11 hours, 05/26/16. The reported Standardized Thermal Transmittance (Ust) was determined using CTS Method, per Section 9.2(A) of NFRC 102. *Stated per NFRC 101 www.archtest.com www.intertek.com/building

Page 6 of 8 Glazing Deflection: Estimated center gap width upon receipt of specimen in laboratory (after stabilization) Center gap width at laboratory ambient conditions on day of testing Center gap width at test conditions Glazing Edge Gap Width 0.52" 0.50" 0.50" 0." Glass collapse determined using a digital glass and air space meter The sample was inspected for the formation of frost or condensation, which may influence the surface temperature measurements. The sample showed no evidence of condensation/frost at the conclusion of the test. This test method does not include procedures to determine the heat flow due to either air movement through the specimen or solar radiation effects. As a consequence, the thermal transmittance results obtained do not reflect performances which are expected from field installations due to not accounting for solar radiation, air leakage effects, and the thermal bridge effects that have the potential to occur due to the specific design and construction of the fenestration system opening. The latter can only be determined by in-situ measurements. Therefore, it is important to recognize that the thermal transmittance results obtained from this test method are for ideal laboratory conditions and should only be used for fenestration product comparisons and as input to thermal performance analyses which also include solar, air leakage and thermal bridge effects. The test sample was installed in a vertical orientation, the exterior of the specimen was exposed to the cold side. The direction of heat transfer was from the interior (warm side) to the exterior (cold side) of the specimen. The ratings were rounded in accordance to NFRC 601, NFRC Unit and Measurement Policy. The data acquisition frequency is 5 minutes. ANSI/NCSL Z50-2-1997 type B uncertainty for this test was 2.56%. Required annual calibrations for the Architectural Testing Inc., an Intertek company ("Intertek- ATI"), 'thermal test chamber' (ICN 00287) in Fresno, California were last conducted in April 2016 in accordance with Intertek-ATI calibration procedure. A CTS Calibration verification was performed February 2016. A Metering Box Wall Transducer and Surround Panel Flanking Loss Characterization was performed April 2016. www.archtest.com www.intertek.com/building

Page 7 of 8 "Ratings included in this report are for submittal to an NFRC licensed IA for certification purposes and are not meant to be used for labeling purposes. Only those values identified on a valid Certification Authorization Report (CAR) are to be used for labeling purposes." Intertek-ATI will service this report for the entire test record retention period. Test records that are retained such as detailed drawings, datasheets, representative samples of test specimens, or other pertinent project documentation will be retained by Intertek-ATI for the entire test record retention period. The test record retention end date for this report is May 26, 2020. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen tested. This report may not be reproduced, except in full, without the written approval of Intertek-ATI. For INTERTEK-ATI Tested By: Reviewed By: William Simon Smeds Technician Kenny C. White Laboratory Manager Individual-In-Responsible-Charge WSS:ms Attachments (pages): This report is complete only when all attachments listed are included. Appendix-A: CTS Calibration Data (1) Appendix-B: Surround Panel Wiring Diagram (1) Appendix-C: Baffle Wiring Diagram (1) Appendix-D: Submittal Form and Drawings (12) www.archtest.com www.intertek.com/building

Page 8 of 8 Revision Log Rev. # Date Page(s) Revision(s) 0 06/29/16 All Original Report Issue. Work requested by Mr. Joaquin Infante of Nu Vista WD, Inc. This report produced from controlled document template ATI 00025(a), revised 0/21/2016. www.archtest.com www.intertek.com/building

Appendix A: CTS Calibration Data 1. CTS Test Date 2. CTS Size 07/2/15 19.38 ft 2 3. CTS Glass/Core Conductance. Warm Side Air Temperature 0.0 Btu/hr ft 2 F 69.80 F 5. Cold Side Air Temperature -0.38 F 6. Warm Side Average Surface Temperature 5.91 F 7. Cold Side Average Surface Temperature 3.6 F 8. Convection Coefficient (Kc) 0.3 Btu/(hr ft 2 F 1.25 ) 9. Measured Cold Side Surface Conductance (hc) 5.37 Btu/hr ft 2 F 10. Measured Thermal Transmittance 0.31 Btu/hr ft 2 F

Appendix B: Surround Panel Wiring Diagram +1 +2 +3 + +5 +6 +7 +8

Appendix C: Baffle Wiring Diagram +1 +2 +3 + +5 +6 +7 +8 +9 +10 +11 +12 +13 +1 +15

Appendix D: Submittal Form and Drawings

NET FRAME HEIGHT 59'' 16'' O.C. 6'' MAX 1 6'' MAX 6'' MAX 16'' O.C. 6'' MAX 7'' NOMINAL: PANEL 7'' NET FRAME WIDTH 16'' O.C. 3 16'' O.C. 16'' O.C. 16'' O.C. 6'' MAX 6'' MAX 6'' MAX 16'' O.C. 16'' O.C. 6'' MAX 2 SCALE 1:1 DRAWING NO. CERT-M250T-O-3B SHEET 3 OF 5 TITLE: MALIBU 250T LABORATORY TEST (FRAME ANCHORING) CUSTOMER: NU VISTA W.D Inc JOB NAME: MALIBU 250T BLOCK FRAME CERTIFICATION DRAWING BY: SERGIO M. COMENTS: DATE:

1 1 FRAME 2 3 '' 3 2A 1 1A MALIBU 250T FIX FRAME 2 1A ANODIZED ALUMINUM FINISH P.O.No: MALIBU 250T FIX BLOCK FRAME NFRC 2A 1 1A 1A EXTERIOR 2 MALIBU 250T FIX FRAME FRAME 2 3 '' SCALE 1:1 DRAWING NO. CERT-M250T-O-1B SHEET 1 OF 5 TITLE: MALIBU 250T LABORATORY TEST (HORIZONTAL CROSS SECTION) CUSTOMER: NU VISTA W.D Inc JOB NAME: MALIBU 250T BLOCK FRAME CERTIFICATION DRAWING BY: SERGIO M. COMENTS: DATE:

FRAME 2 3 '' DRAWING BY: SERGIO M. COMENTS: DATE: 1 1A EXTERIOR 1A 2A 1A 3 MALIBU 250 FIX FRAME MALIBU 250 FIX FRAME 3/'' Cut out on frame and glass stop Cut from end '' TITLE: MALIBU 250T LABORATORY TEST (VERTICAL CROSS SECTION) CUSTOMER: NU VISTA W.D Inc JOB NAME: MALIBU 250T BLOCK FRAME CERTIFICATION 2A 1 D 01 2B D 01 MALIBU 250T FIX FRAME DRAINAGE SECTION VIEW NOTE: 1. Cut out (3/"wide x 3/16" tall) in track base is necessary to allow for water drainage (" from each end) SCALE 1:1 DRAWING NO. FRAME 2 3 '' CERT-M250T-O-2B SHEET 2 OF 5

1/'' TEMPERED GLASS 1/'' TEMPERED GLASS 1/'' TEMPERED GLASS G1 FIX 1'' GLAZING DETAILS GLASS BITE 1/2" 1/2'' ALUMINIUM SPACER 1/'' TEMPERED GLASS 1/'' TEMPERED GLASS 1/'' TEMPERED GLASS GASKET SETTING BLOCK GLASS STOP 1'' G2 FIX 1-1/2'' GLAZING DETAILS GLASS BITE 1/2" 1/2'' ALUMINIUM SPACER 1/'' TEMPERED GLASS GASKET GLASS STOP 1-1/2'' SETTING BLOCK SCALE 1:1 DRAWING NO. CERT-M250T-O-5B SHEET 5 OF 5 TITLE: MALIBU 250T LABORATORY TEST (BILL OF MATERIALS AND GLAZING DETAILS) CUSTOMER: NU VISTA W.D Inc JOB NAME: MALIBU 250T BLOCK FRAME CERTIFICATION DRAWING BY: SERGIO M. COMENTS: DATE:

1 1 2'' 1 5 8'' GLASS STOP 1'' GLAZING 2 3 '' 2 1 '' 1 BLOCK FRAME SCALE 2:1 DRAWING NO. CERT-M250T-O-B SHEET OF 5 TITLE: MALIBU 250T LABORATORY TEST (COMPONENTS) CUSTOMER: NU VISTA W.D Inc JOB NAME: MALIBU 250T BLOCK FRAME CERTIFICATION DRAWING BY: SERGIO M. COMENTS: DATE: