H050 E 97.1.DF.2. Automatic Levels AS-2 / AS-2C

Similar documents
Automatic Level NP-732

取扱説明書 /INSTRUCTION MANUAL 自動レベル /AUTOMATIC LEVEL AT-B2/B3/B4 FC10386-A012-02

Owner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free:

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

~.LIETZ ~. LI ETZ INSTRUCTION MANUAL DOUBLE CENTER THEODOLITE TM-20C THE LIETZ COMPANY E. Del Arno Blvd. Carson, Ca (213)

WATTS MICROPTIC ALIDADE OPERATING INSTRUCTIONS 20-7

DWT-10 Instruction Manual

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

22X Builder s Transit Level Model No Instruction Manual

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

22X Builder s Level Model No Instruction Manual

Surveying Instruments. B Series B20 B30 B40. Automatic Levels

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

AL 22 / 26 Classic Инструкция по использованию FIN RUS / / Rev.01.07

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

LT8-300LTU Owner s Guide

LEAPERS, INC. RED/GREEN DOTS

x Builders Level Service Manual

SCHIEBER TELESCOPES. Unique, High-Quality Telescopes

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE

Fig. 1. instrument is in the case

Electron Microscopy Sciences INSTRUCTION MANUAL. Stereo Microscopes Non-illuminated Stands

Operating Manual 1.1-4x24 Zenith x24 Zenith

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE (PASILL2)

2-7x32. Instruction manual

5-25x56 PMII PSR Illuminated with Double Turn

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

Second Focal Plane MOA

5-25x56 PMII PSR With Double Turn

Table of Contents. Specifications 1 Adjustments 2 Using the Reticle 8 Maintenance 16 Troubleshooting 18 SS Warranty 19

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305)

NcSTAR SHOOTER II SERIES SCOPE

SpecterOS4x Optical Sight Operation Manual

MC ILLUMINATED USER MANUAL

4-14X44 FRONT FOCAL PLANE SCOPE WITH ARC-2 MOA RETICLE

Platinum Series. 6-30x56 Front Focal Plane Scope. with Patent Pending DEKA MIL Reticle. DEKA MIL reticle for unsurpassed accuracy at long range

???? The Vortex Crossfire II Riflescopes

USER MANUAL. Core TX Riflescope Series

C A S S I N I. MODEL : C EQ3 900mm X 135mm COSMO BRANDS INC.

CIV : THEODOLITE ADJUSTMENT

EE 1/3.5х14 U EE 1/3.5х14 U

RT-6 Riflescopes. User Guide

DIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

USER MANUAL RIFLESCOPES. Triple Duty & Tactical Series. English / Francais / Español / Deutsch

PLI Support Guide: Robotic Total Station Field Calibration

GT-510/510L series Instruction Manual

S5 SERIES Rifl escope Rifl

USER MANUAL. EZEKIEL 3-30x56. Riflescope. English / Francais / Español / Deutsch

RP-100 TELESCOPE Instruction Manual

Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Radius Bar. Reticle Focus. Elevation Adjustment Knob

Dual Red or Green Electronic Dot Sight Instruction Manual

Directions for use

MARINE BINOCULARS ZHUMELL 7X50 MARINE BINOCULARS WITH COMPASS AND RETICLE

ZENITHSTAR 61 APO. Owner s Manual ver

Carlson CR Robotic/Reflectorless Total Station

Red and Green Dot Sight FF26002 USER MANUAL

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

BINOCULAR. 50 mm Tactical Binocular Manual HD R/T

EPOCSELFIR LACITCATiX5T TECHNICAL MANUAL

CBRD30CP3 & BOWRD30CP INSTRUCTION MANUAL

The 50mm Viper R/T binocular is equipped with the Vortex R/T Ranging reticle, designed to assist the user in calculating distances.

HD Gen II 1 6x24 Riflescope. The Vortex Razor

SURVEYING INSTRUMENTS DT7C DT20C. Electronic Digital Theodolite OPERATOR'S MANUAL

THE HAVERFORD UNIVERSITY S STRAWBRIDGE OBSERVATORY S OF THE 16 MEADE. A quick guide to using the 16 Meade Schmidt-Cassegrain Telescope

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

C A S S I N I TRACKER

SpecterOS3.0 Optical Sight Operation Manual

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

Cleveland State University

AGES CF600PM. 50 mm Telescope w/ AZ Pan Tilt Mount Instruction Manual. WARNING! SUN HAZARD: Never look directly at the sun with this device.

P4Xi TACTICAL Riflescope TECHNICAL MANUAL

C4 PLUS RIFLESCOPES User Guide

Instruction Manual. Model #: (Reflector) Lit #: / 06-07

Telescope. 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit.

AccuAligning TM Polar Scope for SmartEQ TM Portable German Equatorial GOTO Mount. Installation and User Manual. Product #3130

CHAPTER 10. HASTY SURVEY

Assembly Manual for the Brevard Astronomical Society 16 inch F4.5 Dobsonian Telescope Brevard Astronomical Society P.O. Box 1084 Cocoa, FL 32922

ULTRA SHOT PLUS - DARK EARTH REFLEX SIGHT SM26008DE

S7SERIES. Rifl escope

30 mm Diameter Main Tube 1-4x24 Models

Basic Operation Adjust the eyecup

RP-200 TELESCOPE Instruction Manual

Total station LEICA TPS

User Manual for Blackhawk Riflescope

CASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION

Leveling. 3.1 Definitions

BINOCULAR STEREOSCOPIC MICROSCOPE MBS-10. User Manual

DISPERSION OF A GLASS PRISM

RANGE-FINDERS FOR USE OF INFANTRY AND CAVALRY HANDBOOK OF WITH DESCRIPTION AND INSTRUCTIONS FOR THEIR CARE AND USE (TWELVE PLATES) DECEMBER 9, 1915

NG114mm 114mm Newtonian Telescope w/ Equatorial Mount Instruction Manual

Polar Alignment of LX200R and Ultra Wedge For The Southern Hemisphere by Chris James

Flexbar 6.3:1 MANUAL ZOOM STEREO MICROSCOPE. 250 Gibbs Road, Islandia, NY (P) (F)

CASSINI CQR-120 OPERATING INSTRUCTIONS

The Vortex Razor HD Gen II-E 1 6x24 Riflescope

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

Digital Land Surveying And Mapping(DLS&M) Dr. Jayanta Kumar Ghosh Department of Civil Engineering Indian Institute of Technology, Roorkee

The Vortex Razor HD Gen II 1 6x24 Riflescope

Transcription:

H050 E 97.1.DF.2 Automatic Levels AS-2 / AS-2C ikoninstruction Manual

Thank you for purchasing the Nikon automatic levels AS-2/AS-2C. The AS-2/AS-2C is designed for high precision surveys in civil engineering and architectural construction. Leveling of the instrument can be easily attained by rough adjustment, enabling uniform surveying accuracy with no sighting errors. Moreover, the waterproof telescope allows you to use the instrument even in moist circumstances such as in rain or in tunnel construction. The AS-2C is identical to the AS-2 except that it is provided with a horizontal circle. Please read this instruction manual thoroughly to get fully acquainted with the product. * Waterproof: No signs of water intrusion to the inside of the instrument after it has been left in the water for 30 minutes with its uppermost part 150mm or deeper, and its lowest part 1m or deeper below the water surface. Nikon-Trimble reserves the right to make such alterations in design as may be considered necessary in light of experience. For this reason, specific details and illustrations in this handbook may not conform in every detail to models in current production.

CARE AND MAINTENANCE Hi When carrying The instrument should be carried encased. 11 you insist on carrying it while left attached to a tripod, keep them vertical. Never support them on the shoulder. 2. Rain The instrument can be used in the rain, but be sure to wipe off the moisture after use. 3. Storage Store the instrument in a shady dry place. 4. Cleaning lens Remove the smudges and linger marks from the lens using soft tissue or soft washed-out cotton cloth free from lint and grease. 5. Cleaning plastic case Use the neutral detergent. Never use any organic solvents (such as thinner, ethyl alcohol, xylene.) 6. Cleaning horizontal circle (AS-2C only) When the horizontal circle is stained or fogged up,it can be cleaned. Remove the horizontal circle cleaning window cover at the side of the instrument. Moist the clean soft cloth with a small amount of absolute alcohol and wipe the circle from the center to the rim. Replace the cover securely. 7, Do not turn the attaching screws Do not overturn or release the attaching screws since the firmness of the screws are all figured out to maintain the best performance of the instrument. ii

CONTENTS CARE AND MAINTENANCE I. NOMENCLATURE ii 1 II. USAGE 3 III. CHECKING AND ADJUSTMENT 1.Circular level 2. Horizontality of the line of sight 7 7 9 IV. OPTIONAL ACCESSORIES 1. Plane parallel micrometer-3 2. Illuminator-3 3. Diagonal eyepiece prism 4.Zenith prism 11 11 14 15 15 V. SPECIFICATIONS 16 iii

II!. NOMENCLATURE j. \1. Right Side (for AS-2/AS-2C) Fig. 1 Mirror Circular level Circular level adjusting screw Horizontal fine-motion knob Bottom plate Optical sight * Focusing knob Objective hood f Objective Mounting index for optional accessories leveling screws leveling spring plate 2. Left Side (for AS-2) Fig. 2 Reticle adjusting screw cover I \ Horizontal fine-motion knob / Eyesight adjusting ring Eyepiece 1

I 3. Left Side (for AS-2C) Fig. 3 Horizontal circle illuminating window Reticle adjusting screw cover Eyesight adjusting ring l 0 fine-motion knob Horizontal Nfk»n Horizontal circle \ cleaning window cover Horizontal circle revolver / Eyepiece \ Horizontal circle reading eyepiece 2

Ill USAGE! 1. Set a tripod._ Set a tripod on the ground. Make sure that its head is approximately level. \2. Mount the instrument. Gently take out the instrument from its plastic case. Mount it on the tripod. Secure it by the lock screw from underside. Level the instrument. W The circular level shows the inclination of the instrument. When its air bubble is placed inside the brown circle, the instrument is within its automatic compensation range (±12 ). If not, adjust three leveling screws to bring the air bubble inside the brown circle. When more accuracy is required, place the air bubble exactly at the center of the brown circle. When spherical head tripod is used: Slightly loosen the lock screw. Hold the bottom plate of the instrument and slide it along the spherical head to bring the air bubble inside the brown circle. Tighten the lock screw. When more accuracy is required, place the air bubble exactly at the center of the brown circle. 4. Adjust the diopter. Remove the objective cap and look into the eyepiece. Turn the eyesight adjusting ring to focus on the crosshairs inside the viewfield. 3

T 5. Focus on the target. Aim on a target using the optical sight. Bring the taget to the center of the viewfield using horizontal fine-motion knob. Focus on the target using focusing knob. Make sure that there is no parallax existing. (See page 5.) 6. Check the horizontality. Check the circular level from the eyepiece side using the mirror. If the air bubble is inside the brown circle, the line of sight inside the viewfield is showing the exact horizontal line. If not, adjust the leveling screws to bring the bubble inside the circle. 7. Survey. Measuring height difference between points A and B Set the instrument halfway between points A and B and read the rods (I) and (II). The difference between the readings is the height difference. Example: Height difference between the points A and B = Reading on the rod (I) - Reading on the rod (II) = 197.7cm - 89.3cm = 108.4cm Fig. 4 f1=197.7cm Rod (!) A I! ha(tentative heigh?)=25m _L Level T m Tentative base plane Rod (II) <2=89.3cm B hif1-f2=108.4cm ha=ha+h=2608.4cm 4

Measuring distance from the instrument center to the target (Stadia measurement) Stadia lines inside the viewfield is used for distance measurement. Read out the length on the rod imaged between the two stadia lines. Multiply the length by 100 to get the distance L from the instrument center to the target. Fig. 5 Fig. 6 i i 4 t Stadia lines About the focusing knob The focusing knob functions as coarse focus knob and fine focus knob. Due to this coaxial coarse/fine focusing mechanism, the rotation torque changes during rotation. When felt heavy, the knob is under coarse focusing motion and when felt light, under fine focusing motion. The coarse/fine switching is performed automatically. The rotation starts with fine focusing motion, and switches to coarse motion after turned for approximately 120. When turned to opposite direction, it returns to fine focusing motion. The rotation speed of coarse and fine focusing motion is about 5:1. About parallax When there is a parallax (focusing difference between the crosshairs and the target), your eyes will feel deep fatigue and the measurement will show the incorrect value. To check the existence of parallax, look through the eyepiece and move the eye vertically and horizontally to check if the relative position of the target and the crosshairs changes. 5

If the relative position does not change, there is no parallax. If the relative position changes, there is a parallax. Refocus on crosshairs and the target respectively to eliminate the parallax. About automatic compensation The adjusting mirror inside the instrument automatically compensates the inclination of the instrument body. The automatic compensation range is ±12. When the air bubble is inside the brown circle, the inclination of the instrument body is within ±12, thus providing exact horizontal line of sight. When this automatic compensating function is working correctly, the targert image moves inside the viewfield when the tripod is tapped lightly. About horizontal circle (AS-2C only) Look into the horizontal circle reading eyepiece to find the scale patterns. One division represents 10 or 10 c. The horizontal circle can be set at the desired position by the horizontal circle revolver. Fig. 7 Fig. 8 S -0-359 "I Horizontal circle revolver =_ n Scale Patterns (Degree) Reading: 359 57 Scale Patterns (Gon) Reading: 399992 6

til CHECKING AND ADJUSTMENT The instrument should be checked periodically to assure its best performance. 1. Circular level The circular level axis should be set parallel to the vertical axis of the instrument. Checking Set the instrument so that the air bubble is at the very center of the brown circle. Turn the telescope 180 and check if the air bubble is not moving away from the center of the brown circle. If it does, adjustment is needed. Fig. 9 Bring the air bubble at the very center, m II m. Fig. 10 Hr The air bubble should stay at the center. 7

Adjusting Use the leveling screws to move back the air bubble half the way of its displacement. Then, use the supplied hexagonal wrench to turn the circular level adjusting screws to move back the air bubble to the very center of the brown circle. Check that the air bubble does not move away from the center of the brown circle whichever position the telescope is turned. Fig. 11 Fig. 12 Center Displaced air bubble "y 7 Use leveling "7/ screws to move back till this position 1 \(haif of displacement) \ Use adjusting screws \ to move back to \the center Mirror Hexagonal wrench Circular level adjusting screws i ( Flip up the mirror (Refer to Fig.12) when adjusting the bubble position. Mirror can be turned 90, 8

2. Horizontality of the line of sight The line of sight seen through the eyepiece is etched on the reticle inside the eyepiece. This reticle should be set at the right position, or the line of sight will not show the exact horizontal line. Checking (l)set two rods F and R, 70-100m apart from each other. Set the instrument halfway between them. (Mount it on the tripod and bring the air bubble inside the brown circle.) (2)Sight two rods and take readings of rodf as FI, and rodr as Rl. Calculate Fl-Rl to get the height difference between two points. (3)Reset the instrument at 2m distance from rod R. Sight two rods and (4)No take readings of rodf as F2, and rod R as R2. Calculate F2-R2 to get the height difference between two points. adjustment is needed when F1-R1=F2-R2. If Fl-Rl +F2-R2, perform the adjustment. Fig. 13 When the reticle is at the right position, F1 - R1 = F2 - R2 F1 Fig. 14 Ft F Rod R F R Level / i R1 62 T level W ( - - 2m - When the reticle is not at the right position, FI - R1 * F2 - R2 F Rod R F R rs Level R1 F2 level, --2m. ] R2 R2 r 9

Adjusting (l)calculate F3=R2+(F1-R1). (2) Screw off the reticle adjusting screw cover near the eyepiece. (3) Sight the distant rod (rod F). Adjust the reticle adjusting screw by the supplied hexagonal wrench to make the line of sight pointing out the F3. (4)Perform above checking to ensure that F1-R1=F2-R2. Fig. 15 R F2 F3 H... 2m - Level R2 Fig. 16 Reticle adjusting screw O ) j Reticle adjusting screw cover 10

B1 OPTIONAL ACCESSORIES _ÿÿ1. 1 Plane parallel micrometer-3 Plane parallel micrometer-3 enables the parallel vertical translation of the optical axis. The amount of translation is indicated on the micrometer drum, thus enabling the fraction reading of the precision rod down to a unit of 0.1mm. Attachable type Fig. 17 Measuring range: ±5mm/100 divisions index tct. - Minimum reading: 0.1mm/1 division Measuring accuracy: within 0.05mm Micrometer Nikon MICROMETER-3 I8mm(0.1mm/1dlv \ JAPAN "Jill Fig. 18 Line of sight i: 5mm") *,CSarnp Clockwise rotation raises the opticai axis. i k 111 K I No change in optical axis. i 5mm Line of sight it t.f Counterclockwise I rotation lowers the optical axis. 11

Usage (1) Attach the micrometer-3 to the object hood of a instrument. Match their index dots and clamp the micrometer-3. (2)Turn rod. (3)Look the micrometer drum to the position 5. Sight the precision into the eyepiece to find the wedged lines on the right side of the viewfield. Turn the micrometer drum clockwise or counterclockwise to bring a graduation line of the precision rod just in between the wedged lines. (Be sure to select a graduation line which is nearest to the wedged lines.) Since the image of the graduation lines appears thin or thick according to the distance between the rod and the instrument, use the appropriate openings of the wedged lines. Fig. 19 50m 10m 5m 3m. c. = (4) Add the micrometer reading to the rod reading (read the graduation line in between the wedged lines). Fig. 20 When sighted. I'l tr ; Reading 1550 mm r 7.8 1557,8 mmfc* Turn counterclockwise to bring the nearest graduation iine in between the wedged lines. 12

NOTE: When plane parallel micrometer-3 is used, the measured height may not conform with the actual height of the position which is indicated by the line of sight, since the optical axis of the instrument is being translated. But the height difference of the two points can be calculated correctly since the measured height is always obtained in the same manner. 13

2. Illuminator-3 W Illuminator-3 is used to light up the crosshairs inside the viewfield. It is useful in dark circumstances such as in night or in tunnel construction sites. Attachable type Power source: External power source, or Two AA-type batteries (1,5V) connected in series Lamp bulb: Specified miniature lamp bulb (3V) Fig. 21 iluminator fourceÿwnector Light volume'- "N / Usage (l)when using batteries: Remove the upper cover of the illuminator and set the batteries. When using external power source: Use the specified cord to connect the external power source and the external power source connector on the illuminator. (2)Attach the illuminator to the object hood of a instrument. Fig. 22 (3)Tum the light volume to light up the lamp and adjust its brightness. (4) When exchanging the lamp, turn off the power and remove the upper cover of the illuminator. Wait till the lamp bulb cools enough before exchanging it. Lamp bulb Battery Battery 14

3. Diagonal eyepiece prism i To install, unscrew the eyepiece and replace with the diagonal eyepiece Fig. 25 & prism, then mount the eyepiece onto the open end of the diagonal eyepiece prism. u Zenith prism Fig. 26 Attach the zenith prism to the eyepiece. titt 15

II nspecifications Telescope Internal focusing, anallactic optical system Imagē Erect Magnificatioṉ 34X Effective aperture of objective 45mm ( 1.77in ) Angle of viewfield ( at 100m / 100ft)- 1 20 ( 2.3m / 2.3ft ) Shortest focusing distance - Stadia multiplying constant Stadia additive constant Automatic level compensation range ±12 lm ( 3.28ft ) 100 0 Sensitivity of circular level 1072mm Horizontal circle (AS-2C only) Minimumincrement 10 ( 10 ) Weight and dimensions AS-2 Instrument- AS-2C Instrument AS-2 Plastic case AS-2C Plastic case Complete equipment Main body- Objective cap- Plastic case- Hexagonal wrench- Plumb bob (AS-2C only) 259 x 136 x 142, 1.80kg ( 10.2 x 5.4 x 5.6in, 4.01b ) 259 x 136 x 142, 1.90kg ( 10.2 x 5.4 x 5.6in, 4.21b) 379x 195 x 197, 1.80kg ( 14.9 x 7.7 x 7.8in, 4.01b ) 379 x 195 x 197, 1.90kg ( 14.9 x 7.7 x 7.8in, 4.21b ) 1 1 2 16

Trimble 5475 Kellenburger Road Dayton, Ohio 45424-1099, U.S.A. Phone +1-937-233-8921 Fax +1-937-233-9004 www.trimble.com TDS Tripod Data Systems PO Box 947 Corvallis, OR 97339, U.S.A. Phone +1-541-757-7254 Fax +1-541-752-7133 www.tdsway.com Trimble Europe Trimble GmbH Am Prime Parc 11 65479 Raunheim, Germany Phone +49-6142-2100-0 Fax +49-6142-2100-550 Trimble Asia-Pacific Trimble Navigation Singapore PTE Ltd. 80 Marine Parade Road #22-06, Parkway Parade, 449269, Singapore Phone +65 6348 2212 Fax +65 6348 2232