Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

Similar documents
Finnigan LCQ Advantage MAX

Thermo Finnigan LTQ. Specifications

Analysis of Polar Metabolites using Mass Spectrometry

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

HPLC Praktikum Skript

Mass Spectrometry in MCAL

TANDEM MASS SPECTROSCOPY

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Lecture 15: Introduction to mass spectrometry-i

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Translational Biomarker Core

M M e M M H M M H. Ion Sources

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Chemistry Instrumental Analysis Lecture 34. Chem 4631

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

LC-MS Based Metabolomics

Routine MS Detection for USP Chromatographic Methods

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Webinar: How to be More Successful with your ACQUITY QDa Detector Eric van Beelen

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Lecture 8: Mass Spectrometry

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

FAIMS Technology at a Glance

The Importance of Field Strength in the Low Field Portion of a Differential Ion Mobility Spectrometry Waveform

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

637. Thiamethoxam. HPLC method

MS Goals and Applications. MS Goals and Applications

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

Agilent G3212 GC-APCI Source

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Lecture 8: Mass Spectrometry

Introduction to GC/MS

ANALYTICAL REPORT 1. 4-Me-TMP (C15H21NO2) Remark other NPS detected: none. sample contains some impurities (benzeneacetic acid + others)

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Electrospray Ion Trap Mass Spectrometry. Introduction

Shodex TM ODP2 HP series columns

Hypericin Analysis by LC/MS

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

2,5-DIMETHOXY-4-IODOPHENETHYLAMINE Latest Revision: August 22, 2005

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

MS Goals and Applications. MS Goals and Applications

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

(proton form) (ammonium salt) (proton form) (ammonium salt) LMGP / LM1-057A. -16 to -24 C

Introduction to Mass Spectrometry (MS)

Chromatographic Methods of Analysis Section 2: Planar Chromatography. Prof. Tarek A. Fayed

Training Courses. Chromatography training from the Crawford Scientific experts

Introduction to Pharmaceutical Chemical Analysis

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Experiment 1: Thin Layer Chromatography

Determination of Volatile Substances Proof of Food Adulteration

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

SUPPORTING INFORMATION Antimicrobial activity of chlorinated amino acids and peptides

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

ANALYTICAL REPORT 1 CUMYL-4CN-BINACA (C22H24N4O) 1-(4-cyanobutyl)-N-(1-methyl-1-phenylethyl)-1H-indazole-3-carboxamide

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Acknowledgement: 4F-PBP (C14H18FNO) T: +386 (0) E: Vodovodna Ljubljana SLOVENIJA

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Supporting Information

Determination of Caffeine by HPLC

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

H 3 CO H 3 CO S CH 3

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Chapter 14. Molar Mass Distribution.

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Quantitative Analysis and Identification of Migrants in Food Packaging Using LC-MS/MS

Introduction to the Q Trap LC/MS/MS System

High performance liquid chromatography

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

Calibrating Thermo Exactive with the Direct Analysis in Real Time (DART) Ambient Ionization Source (Protocol Adapted from US FDA FCC)

Hypersil BDS Columns TG 01-05

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

ChromTech HPLC System

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Transcription:

SCIETIFIC ISTRUMET EWS 2016 Vol. 7 SEPTEMBER Technical magazine of Electron Microscope and Analytical Instruments. Technical Explanation Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph Kosaku Toyosaki *1 1. Introduction The market for high performance liquid chromatography (HPLC) has been affected by the addition of new methods for mass analysis to the range of testing methods for pharmaceuticals; this has created demand among HPLC users particularly in the pharmaceutical industry for mass-analysis-based structure identification. However, of the more than 200,000 LC systems in use across the worldwide HPLC market, fewer than 20% have connections to mass analyzers, creating high barriers for HPLC users to break into the world of mass analysis; in particular, at present the prevalence of mass analyzers is significantly less than that of photodetectors for HPLC applications. Among the factors responsible for this low rate of adoption, major barriers include the installation environment required for mass analyzers, issues with maintenance and operation, and the cost of the instruments. In this report, we discuss the Chromaster 5610, a new mass detector designed specifically for the purpose of HPLC that significantly lowers the various barriers preventing HPLC users from making use of mass analysis. Figure 1 shows a photograph of the device and lists its size and weight. The area required for the installation of this device is essentially equivalent to that required for the Chromaster series of high performance liquid chromatographs; the height of the instrument is that of 3 pump modules. The Chromaster series high performance liquid chromatograph Chromaster 5610 MS Detector Fig. 1 Hitachi Chromaster 5610 MS Detector for HPLC Unit dimensions: 440 (W) 610 (D) 430 (H) mm Unit mass: Approximately 51 kg Hitachi High-Technologies Corporation All rights reserved. 2016[82]

2. An overview of the instrument The key strength of this product is that it is a mass detector offering the same ease-of-use as the light-based (UV/FL) detectors typically used in HPLC, but optimized for installation in smaller spaces. In particular, the instrument offers the following advantages. (1) Thanks to a space-reducing compact design, the instrument can be installed in the same amount of area needed for an HPLC system; in particular, the instrument can be installed on a laboratory table with no need to install an additional 200 V power supply. Uses a standard Japanese domestic 100 V power supply; uses reduced quantities of nitrogen gas and organic solvent spray. The miniaturization of the device is made possible by the implementation of a compact, high-precision QMF and a compact TMP. (2) The device offers improved robustness and ease of maintenance. Selection of ion species entering the vacuum chamber via ion separation under ambient conditions. o need to stop the vacuum; maintenance involves cleaning only parts that operate in ambient conditions. 3. An overview of the ion optics system Ions produced by the ESI ion source are induced into the atmospheric ion filter (AIF) by a potential difference with the counter gas plate. The flow of ions within the atmospheric ion filter is perpendicular to the flow of ions generated in the ionization unit, helping to ensure the robustness of the apparatus. In the atmospheric ion filter, ions are separated by mobility which is determined by charge and molecular structure and metastable ions and cluster ions, which contribute to noise, are removed. Then, ions proceed from the AP1 into the interior of the vacuum; by displacing the axis of ion flow from the ion optical axis (the electrode axis following AP2), we prevent the accumulation of dirt on the electrode surface. ext, the ions pass through AP2, the second-stage vacuum separator, and enter Q0. Energy is uniformized through collisions with neutral molecules in Q0. ext, after passing through the three-stage vacuum separator AP3, ions enter Q1 and the subsequent analytical units. In Q1, ions to be measured are selected by the RF/ DC method, in which a DC sweep is superposed on an RF signal. Ions then pass through the endcap which performs collection for the detector and enter the detector. The detector consists of a conversion dynode and a Channeltron detector. In the conversion dynode, ions are exchanged for electrons; these electrons are amplified by the Channeltron detector and detected in the form of a voltage pulse. FA rear AP1 AP2 Q0 AP3 Q1 End cap AIF Conversion Dynode Detector Counter Gas Plate ESI Ion Source Channeltron Detector Fig.2 The ion optics system. Hitachi High-Technologies Corporation All rights reserved. 2016[83]

The ion source is a unit that ionizes sample materials flowed in from the HPLC or syringe pump (Fig. 3). The ion source in this product is compatible with electrospray ionization (ESI); in the ESI method, by applying a voltage of a few kv to counter-facing electrodes and a capillary, static liquid drops are formed, and the sample is ionized by volume compression of these liquid drops. In this product, the sample liquid is split at a stage prior to the ionization unit and the flow rate is reduced to a few μl/min for ionization. For this reason, the quantity of nitrogen gas required during ionization may be significantly reduced. In addition, the AIF (Fig. 4) installed inside the ion source operates in ambient conditions; by applying an AC voltage with an asymmetric waveform and a variable DC voltage between two electrodes, this device separates ions based on mobility. The AIF is integrated into a single monolithic structure with the counter gas plate; maintenance may be performed simply by removing it from the ion source, with no need to stop the vacuum. Fig.3 The interior of the ion source. Fig.4 The atmospheric ion filter (AIF). 4. Applications 4-1 Analysis of oral diabetes medications via infusion analysis Using the Chromaster 5610 MS Detector and a syringe pump, sample liquids may be inserted directly into the mass detector to obtain mass information. This allows acquisition of mass information on synthetic compounds, as well as easy monitoring of compounds while investigating synthesis conditions. Figure 5 shows a sample measurement of vildagliptin, pioglitazone, and linagliptin, compounds used as oral diabetes medications. [M+H] + [M+H]+ [M+H] + [M+a+AC] + [M+a] + [M+K] + [M+H-C 4 H 5 ] + [M+K] + [M+a] + Vildagliptin Pioglitazone Linagliptin Fig.5 A sample measurement using the Chromaster 5610 MS Detector. Hitachi High-Technologies Corporation All rights reserved. 2016[84]

Measurement conditions Chromaster 5610 MS Detector Ionization method : ESI Ionization mode : Positive Ionization voltage : 2,300 V Measurement mode : Scan mode Gas flow rate : 0.6 L/min IS/AIF temperature : 70/120 C Flow rate : 2 μl/min (infusion measurement) Concentration : 10 ppm each Solvent : 10 mm HCH 4 :CH 3 C:HCH = 500:500:1 4-2 Analysis of methyl xanthine species using the PDA detector and the mass detector Figure 6 shows a sample measurement involving caffeine and other methyl xanthine species. These substances are often found in coffee, cocoa products, and nutrient beverages. Because methyl xanthine species share a common basic molecular skeleton, their UV spectral patterns are very similar, and it is difficult to distinguish them based on spectra alone. However, by combining measurements with a mass detector which obtains information on substance-specific masses, the accuracy of the identification procedure is improved. H CH 3 CH 3 H 3 C H 3 C HH H 3 C 1. Theobromine CH 3 CH 3 CH 3 CH 3 (Molecular weight: 180) 2. Theophylline (Molecular weight: 180) *Concentration: 10 ppm each; solvated in methanol 3. Caffeine (Molecular weight: 194) 4. 7-(2-Hydroxyethyl) -theophylline (Molecular weight: 224) UV spectra Mass spectra Fig.6 A sample measurement involving the LC-PDA detector and the mass detector. Hitachi High-Technologies Corporation All rights reserved. 2016[85]

Measurement conditions Column : HITACHI LaChrom II C18 (3 μm) 4.6 mm I.D. 100 mm Eluent : A: 0.1% formic acid solution, B: 0.1% formic acid-containing MeH 0-5 min: 10-50% B; 5-5.1 min 50% B; 5.1-8 min 50-10% B Flow rate : 1.0 ml/min (split) Column temperature : 50 C Detection wavelength : 275 nm Input volume : 10 μl Mass detector Ion source : ESI Ionization voltage : 2,800 V, Positive Measurement mode : Scan, m/z 100-300 Gas flow rate : 0.7 L/min IS/AIF/API temperature : 120/170/170 C First pore voltage : 50 V Second pore voltage : 10 V 4-3 Analysis of an antibacterial agent (Triclosan) Figure 7 shows a sample measurement involving the antibacterial agent Triclosan. Triclosan is an antibacterial agent used against common bacteria; its applications range from health-care products such as pharmaceutical soap and toothpaste to plastics for children's toys and cloth products. Because the Chromaster 5610 MS Detector does not require any complicated configuration of settings, one obtains mass information via procedures similar to those used for UV detectors, thus obtaining calibration curves. Sample measurement involving LC-UV and mass detection Linearity Detection: UV 286 nm Area Detection: SIM, m/z 288.6 Concentration (μg/l) [Calibration curve for 10 100 μg/l triclosan] Fig.7 Sample measurement involving LC-UV and mass detection (10 μg/l triclosan) [ Triclosan MS spectrum] Measurement conditions Column : HITACHI LaChrom II C18 (3 μm) 3 mm I.D. 100 mm Eluent : Methanol Flow rate : 0.3 ml/min (split) Column temperature : 40 C Detection wavelength : 286 nm Input quantity : 10 L Triclosan Mass detector (MSD) Ionization method : ESI Ionization mode : egative Ionization voltage : 2,300 V Measurement mode : SIM, m/z 288.6 Gas flow rate : 0.6 L/min IS/AIF temperature : 70/120 C [Structure of triclosan] Hitachi High-Technologies Corporation All rights reserved. 2016[86]

5. Summary The Chromaster 5610 MS Detector is a new detector that avoids the problems of conventional mass analyzers that have traditionally served as barriers between HPLC users and mass-analysis techniques. The new ability to obtain mass information offers the promise of greatly enhancing the reliability of qualitative analyses. Author *1 Kosaku Toyosaki ptical Instruments Design Group 1 ptical Instruments Design Department Hitachi High-Tech Science Corporation Hitachi High-Technologies Corporation All rights reserved. 2016[87]