Thermo Scientific Neptune XT MC-ICP-MS

Similar documents
Defining quality standards for the analysis of solid samples

of mass spectrometry

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

ICP-MS. High Resolution ICP-MS.

Finnigan TRITON Finnigan NEPTUNE. High Resolution Multicollector Mass Spectrometers

Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers

Improvement of bulk analysis of environmental samples by using a multiple collector ICP-MS

Low level Os isotopic measurements using multiple ion counting

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Exploring new fields of Applications using Multi Collector Magnetic Sector MS

PERSPECTIVE STABLE ISOTOPE RATIO MS

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

PERSPECTIVE STABLE ISOTOPE RATIO MS

Interface (backside) & Extraction Lens

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Thermo Scientific 253 Plus 10 kv Isotope Ratio MS. Utilize the Gold Standard. in isotope ratio MS. Robustness Sensitivity Precision

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

ICP-Mass Spectrometer

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Nu Plasma II - Collector Configuration

Translational Biomarker Core

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Uncertainty in Measurement of Isotope Ratios by Multi-Collector Mass Spectrometry

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Error Analysis. The big questions are: - What value best represents a set of measurements and how reliable is it?

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

ICPMS Doherty Lecture 1

Extrel Application Note

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

Catalysis CAPABILITIES

Thermo Finnigan LTQ. Specifications

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Beam Diagnostics and Instrumentation JUAS, Archamps Peter Forck Gesellschaft für Schwerionenforschnung (GSI)

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Introduction to Fourier Transform Infrared Spectroscopy

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

110 Lowell Rd Hudson, NH USA Tel:

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

OES - Optical Emission Spectrometer 2000

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

The Evolution of Inductively Coupled Plasma - Optical Emission Spectroscopy (ICP-OES)

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

Precise Pb isotope analysis of igneous rocks using fully-automated double spike thermal ionization mass spectrometry (FA -DS- TIMS)

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Finnigan LCQ Advantage MAX

PHI. Scanning XPS Microprobe

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Application of the GD-Profiler 2 to the PV domain

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

Spectrometric Methods of Analysis. OCN 633 Fall 2013

An Overview of Magnetic Sector Inductively Coupled ICP and GD-MS. Isaac (Joe) Brenner

Introduction to Fourier Transform Infrared Spectroscopy

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Advanced ICP-MS techniques for overcoming interferences in LA-ICP-MS bioimaging

Antonio Simonetti University of Notre Dame

The Analyzer. We will deal mainly with magnetic sector instruments here although we will talk briefly about other separation methods later.

Fergus Keenan Shona McSheehy Julian Wills

Trace Analyses in Metal Matrices Using the ELAN DRC II

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

A DIVISION OF ULVAC-PHI. Quantera II. Scanning XPS Microprobe

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

Agilent 8900 Triple Quadrupole ICP-MS

Extrel is widely respected for the quality of mass spectrometer systems that are

Secondary Ion Mass Spectrometry (SIMS) Thomas Sky

Sample Analysis Design PART II

SmartNotes. What is meant by the term interference?

Product Descriptions and Offerings

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Transcription:

Thermo Scientific Neptune XT MC-ICP-MS

Neptune XT MC-ICP-MS A new edition of the market leading Thermo Scientific Neptune Series MC-ICP-MS, capturing the best of technology for high-precision isotope ratio analysis. 2

Thermo Fisher Scientific: pioneering multicollector technologies, First with RPQ for abundance sensitivity. First to introduce a reliable moveable collector array, over 500 built. First to report ultra-high-precision static isotope ratio measurements. First for high-resolution MC-ICP-MS, enabling measurement of Si, S, Ca, Fe, Ni and many more isotopic systems. First with stable and linear SEM and then CDD ion counters. First for sensitivity the Jet Interface offers the highest ICP-MS sensitivity available. First with 10 13 Ω Amplifier Technology, extending the benefits of Faraday cup detectors to smaller sample amounts. First with the XHR option 15,000 MRP for hydride interference removal from 25 Mg, 29 Si, 37 Cl and 41 K. All these firsts have been supported by continuous improvement of our instrumentation, with software that facilitates access to the latest technologies. The Neptune Series instruments are the established market leader for MC-ICP- MS, with an enviable reputation for producing robust scientific data. Every Neptune Series instrument is supported by a professional global organization that ensures long term, ongoing support. The result is a user base that has achieved exceptional scientific productivity. perfecting multicollector technology for application. 3

Neptune XT MC-ICP-MS Combining two decades of development The Neptune XT is a double-focusing multicollector inductivelycoupled plasma mass spectrometer (MC-ICP-MS), integrating the established field-proven technologies from the Neptune Series instruments, with the latest developments in technology for isotope ratio analysis from Thermo Fisher Scientific. The Neptune XT MC-ICP-MS incorporates Thermo Scientific 10 13 Ω Amplifier Technology and the Jet Interface, so that users can extract the highest precision information from their samples. For the toughest analytical challenges the Neptune XT MC-ICP-MS can be configured with options for enhancing resolution (XHR), abundance sensitivity (RPQ) or with an ion counter array (SEM and CDD). Every user benefits from the stability of the Neptune series instrumentation. Tuning is aided by the stability of tune parameters, so that less time and effort is spent tuning and more time is spent generating robust scientific data sets. The fundamentals of the mass analyzer The Neptune XT MC-ICP-MS separates ions generated by an inductively-coupled plasma through a double-focusing mass analyzer onto a variable multicollector detector array. The kinetic energy distribution of ions generated by an ICP ion source is wider than that from a thermal ionization source, and a double-focusing mass analyzer is the best technical solution for this problem. The result is an accurate separation of masses focused onto focal plane, along which ion detectors can be brought into precise alignment with the ion beams. 4

Jet Interface Ultimate sensitivity, ultimate precision The ultimate theoretical limit to precision for any isotope ratio measurement is from the counting statistics of the number of ions which are detected. In many applications this dictates the minimum sample amount from which useful information can be extracted. The Jet Interface, in combination with a desolvating nebulizer system, increases sensitivity by a factor of ca. 25. Sample ion yields of greater than 1.8 % are achieved for uranium, and it is well recognized as the most sensitive ICP-MS available. Sensitivity is matched by stability of mass bias, so the advantages of higher signal intensities are realized with higher precision isotope ratios. This major improvement in ICP-MS technology, where uranium ion transmissions of < 0.1 % are more typical, has lead to a revolution, slashing sample amount requirements and increasing precision. The water-cooled laminated magnet ensures the user can quickly switch between different applications, an essential capability in a multi-user laboratory. The Neptune XT MC- ICP-MS utilizes a 10 kv acceleration voltage, which maximizes transmission and minimizes mass discrimination through the mass analyzer. Combined with proven ion transfer optics and ICP technology, the Neptune XT MC-ICP-MS delivers exceptional accuracy, mass bias stability and sensitivity. An interface at ground potential The plasma interface of the Neptune XT MC-ICP-MS is held at ground potential, allowing safe access to the nebulizer, spray chamber and torch. Changing from solution mode to any coupled device is straightforward; for example to laser ablation, gas chromatography or HPLC. As such the Thermo Scientific GCI-300 Interface for gas chromatography applications can be easily coupled to the Neptune XT MC-ICP-MS. The outstanding performance of the Jet Interface is achieved with a high-performance interface pump, an optimized interface design, and a unique set of cones that address individual application needs. Accurate 143 Nd/ 144 Nd ratios are achieved with a high-sensitivity low-oxide cone combination (H and Jet), whilst 176 Hf/ 177 Hf measurements benefit from the highest sensitivity achieved using the X skimmer cone for example. The benefits also extend to laser ablation applications, where spatial resolution can be increased. Or the laser ablation split stream (LASS) technique can be used to obtain additional elemental or U-Pb information, without compromising the precision of the Lu-Hf or Sm-Nd measurement for example. Sensitivity (V/ppm) 1400 1200 1000 800 600 400 200 0 Wet Plasma, Standard Cones, 100 µl/min nebulizer Dry Plasma, X-skimmer Cone, 100 µl/min nebulizer Li Sr Nd Hf Pb U Sensitivity of the Neptune XT MC-ICP-MS, comparing Jet Interface with wet plasma. Note: sensitivity specifications are given for 100 µl/min uptake rate. A desolvating nebulizer system is required for the dry plasma specifications (optional item). 5

High Resolution MC-ICP-MS The Neptune MC-ICP-MS introduced high mass-resolution to MC-ICP-MS, enabling new applications with high-precision interference-free isotope ratio measurements. Flat interference-free plateaus are ideal for MC-ICP-MS isotope ratio measurements and ensure the highest precision results. The Neptune XT MC-ICP-MS can be operated at three different resolution settings: low, medium and high. A reproducible resolution setting can be conveniently selected through the software. The Neptune XT MC-ICP-MS is optimized for transmission, over 20 % transmission can be retained for measurements of isotope systems such as Si, S and Fe. 95% 5% width Mass Resolving Power = M M ΔM = width in mass units containing 90% of the edge of the peak. M = mass. In order to achieve the high mass resolution necessary to separate molecular interferences from elemental peaks a narrow source slit is selected. Through a combination of narrow source and wide detector slits, interferences can be separated from the analyte ions on either side of the detector slit. The majority of molecular interference are in the low and middle mass range, and according to the systematics of the nuclear mass defect, these interferences are typically heavier than the elemental species. A wide detector slit in all mass resolutions is the best choice, since it guarantees the widest peak flatness, which is essential for highly precise and accurate isotope ratio analyses. Low Resolution Mode High Resolution Mode measurement position Collector Collector m/z Interference + Analyte Interference / Analyte Mass scan for iron isotopes (left), showing the measurement position for high-precision interference-free measurements of δ 56 Fe, δ 57 Fe and δ 58 Fe (Weyer & Schwieters 2003). Schematic depiction of low resolution and high resolution measurement modes (middle and right) showing the separation of interference such as ArO + from the 56 Fe + analyte ions. 6

XHR Extra High Resolution The new Thermo Scientific XHR Option for the Neptune XT MC- ICP-MS increases the resolving power to 15,000 by including a switchable intermediate aperture. By doing so it allows access to hydride interference removal from systems such as Si, Mg, Cl and K. This extraordinary increase in resolution was only possible through nearly 20 years of continual improvement of peak position stability that benefits all today s Neptune XT instruments. CASE STUDY δ 41 K analysis by using XHR mode The potassium isotopic system has applications in terrestrial geochemistry, planetary science, and potentially for biomedical and agricultural research. The strong 40 Ar 1 H interference on 41 K has until recently limited its measurement by MC-ICP-MS. By increasing the resolving power of the Neptune XT MC-ICP-MS, the XHR option opens the door to precise, accurate and routine measurement of the potassium isotopic system by MC-ICP-MS. 40 Ar 1 H + 41 K signal [V] 1.4 41 K/ 39 K 1.2 1.0 0.8 0.6 0.4 0.2 0.0 39.322 39.324 39.326 39.328 39.330 39.332 39.334 mass [u] Mass scans on the 41 K + peak using the new XHR Extra High Resolution Option for Neptune XT MC-ICP-MS. 41 K + is clearly resolved from the polyatomic interference 40 Ar 1 H +. 7

The Detection System Variable detector array At the heart of the Neptune XT MC-ICP-MS is the variable multicollector detector array. A highly reliable mechanism that brings up to nine Faraday cups into precise alignment with ion beams of different dispersions. This ensures the flexibility to cover isotopic applications from Li through to U, in low or high resolution, and without compromising the native dispersion of the mass analyzer. Source Magnet Lens Faraday Cup Magnification = 1 Secondary particles are released close to cup entrance Source Magnet Lens Magnification = 2 Faraday Cup Larger effective depth of cups: less emission of secondaries High-performance Faraday cups The Faraday cups used in the Neptune XT MC-ICP-MS are the same as those used in Thermo Scientific Triton Series TIMS instruments, and are capable of making the highest precision static isotope ratio measurements. The combination of the 2x magnification of the mass analyzer, with wide and deep Faraday cups, means that ion beams are captured in their entirety. Precision machined from solid graphite for uniform response; cup factors are eliminated. Flexibility of detector types The Neptune XT MC-ICP-MS offers a highly flexible detector system, with three different detector types spanning more than 9 orders of magnitude in signal intensity range (from 1 cps to 3 Gcps). The central channel of the Neptune XT MC-ICP-MS is equipped with a dual mode detector that can be switched from Faraday cup to SEM ion counter, and with the proprietary relay matrix any amplifier can be assigned to any of the Faraday cups via software. Multi ion counting arrays The smallest sample amounts and the lowest abundance isotopes require the use of ion counting detectors. The Neptune XT MC-ICP-MS can be fitted with a Multi Ion Counting (MIC) array to allow simultaneous detection of the lowest intensity ion beams. Efficiency is significantly increased when compared with single collector measurements. Up to eight discrete dynode secondary electron multipliers can be installed on the Neptune XT MC-ICP-MS, with packages tailored for different applications (see page 11). The SEM and CDD ion counters available for the Neptune XT MC-ICP-MS offer excellent stability, linearity and lifetime characteristics. 8

CASE STUDY Analysis of 234 U and 236 U in nuclear materials Reliable measurement of 234 U/ 238 U and 236 U/ 238 U provides key information for nuclear safeguarding, but measurements can be challenged by the very low abundance of 234 U and 236 U. Ion counters offer the lowest quantification limits for these isotopes. Scattered ions (tailing), from 238 U and 235 U, can bias the measured ratios. The Retarding Potential Quadrupole (RPQ) improves abundance sensitivity by an order of magnitude, for accurate quantification of minor isotopes. The Neptune XT MC-ICP-MS can be configured with two RPQ lenses for simultaneous 234 U and 236 U analysis. Nuclear MIC packages offer comprehensive coverage of U and Pu isotopic measurements, with flexibility to use combinations for ion counters and Faraday cups for isotopic sample amount from the fg to µg level. Combined with the Jet Interface, for ultimate sensitivity, fg isotopic amounts can be analyzed for precise information. volts 18 1200 238 16 U peak 14 1000 12 800 10 8 600 6 Tailing from 238 U on neighboring mass 400 4 2 200 0 0 236.7 236.8 236.9 237.0 237.1 237.2 237.3 237.4 m/z counts/sec Peak tailing from 238 U onto m/z 237.05 (purple trace cps). The 238 U beam is shown for reference (Volt scale). Tailing at two masses is further reduced; especially applicable to the measurements of 236 U and 230 Th. 9

Neptune XT A new edition of the market leading Neptune Series MC-ICP-MS, capturing the best of technology for high-precision isotope ratio analysis. Vacuum protection system Magnetic sector water cooled laminated fast settling XHR option Electrostatic analyzer (ESA) Dispersion lens for dynamic measurements 2x magnification Reproducible resolution switching Jet Interface ultimate ICP sensitivity & stability ground potential interface capacitive decoupling high-performance pump Inlet systems wet or dry plasma laser ablation hydride generation gas chromatography 10

CASE STUDY U-Pb ages from zircons and carbonates 8 moveable Faraday cups 1 central dual-mode detector no cup factors precise positioning maximum flexibility highly reliable mechanism For geoscience applications the Neptune XT MC-ICP-MS offers dedicated collector packages for the analysis of U-Pb from carbonates, or U-Pb and Lu-Hf or Sm- Nd from zircons and other accessory minerals. The dual detector (Faraday / SEM) for 206 Pb provides coverage for both old and young ages. The setup allows for quick switching between the U-Pb and Lu-Hf or Sm-Nd systems. The Neptune XT MC-ICP-MS delivers on both detection system and sensitivity, allowing more precise measurements to be made with higher spatial resolution than was previously accessible. RPQ (optional) ultra-low abundance sensitivity Ion counter arrays for nuclear safeguards. 10 ion current amplifiers 50 V dynamic range freedom of amplifier selection 10 13 Ω Amplifier Technology high temperature stability SEM high linearity high stability long lifetime CDD SEM RPQ SEM/L5* SEM RPQ L4 CDD 233 U 234 U 235 U 236 U 238 U 233 U 234 U 235 U 236 U 238 U 238 U 239 Pu 240 Pu 241 Pu 244 Pu 239 Pu 240 Pu 241 Pu 242 Pu 244 Pu Ion counter arrays for U-Pb geochronology. CDD CDD SEM/L5* SEM CDD 202 Hg 204 Pb 206 Pb 207 Pb 208 Pb 202 Hg 204 Pb 206 Pb 207 Pb 208 Pb Faraday Cup Ion Counter * Dual-mode detector, switchable between Faraday and SEM. Please contact your local sales specialist to discuss the range of configurations available. 11

10 13 Ω Amplifier Technology Extending the lower limits of the ultimate detector Faraday cups are the detector of choice for high precision isotope ratio measurements. Ion currents can be measured to the highest degree of accuracy and precision, without the uncertainty of linearity and yield corrections. The ion current amplifiers of the Neptune XT MC-ICP-MS are mounted in a doubly shielded, evacuated housing, and temperature regulated to within 0.01 C / hour, which guarantees stable baselines and stable gains. The standard amplifier for MC-ICP-MS and TIMS incorporates a 10 11 Ω feedback resistor, accommodating a wide dynamic range of ion currents, and facilitating ppm-level isotope ratio measurement precision from high intensity ion beams. However, electronic baseline noise limits their application for low intensity ion beam measurements (<500 fa). The proprietary 10 13 Ω Amplifier Technology in the Neptune XT MC-ICP-MS guarantees fast response times with extremely low noise characteristics. The benefits of Faraday cups can now be realized at low signal intensities (30 kcps 3 Mcps), delivering external precisions that approach the ultimate limits of counting statistics. The dynamic range of 10 13 Ω Amplifier Technology extends to 30 Mcps. Exclusive to Neptune and Triton Series instruments is a software controlled relay matrix that connects any amplifier to any Faraday cup. This enables the user to tailor the amplifier-cup configuration to the needs of each measurement. 12

Thermo Scientific 10 13 Ω Amplifier Technology has revolutionized the measurement of isotope ratios from low intensity ion beams, with a growing list of publications that prove the utility and performance of this technology for isotope geochemistry applications. % ε ppm (10 minute) 10 11 Ω F 500 fa - 500 pa 2.10 2.08 CASE STUDY LA-MC-ICP-MS Laser ablation (LA-) MC-ICP-MS is a technique that can be used to extract high precision isotope ratios directly from solids materials. Increasing spatial resolution can result in low intensity ion beams being measured. 10 13 Ω Amplifier Technology with tau correction has been demonstrated to offer up to 4x improvement in precision for laser ablation Pb isotope ratio analysis (see below). Combined with Jet Interface sensitivity, higher precisions can be achieved for smaller sampling volumes. standard 10 11 Ω amplifier 10 13 Ω F 5-500 fa 2.06 2.04 SEM sub - aa - 5fA 2.02 2.00 0.81 0.82 0.83 0.84 0.85 1 100 10k 1M 100M log beam intensity 0.016 1.6 (cps) (v, 10 11 Ω F) Optimum operating ranges for the three different detectors incorporated into the Neptune XT, and the level of precision that could be expected from counting statistics for a 10-minute measurement. Over 9 orders of magnitude in signal intensity range are spanned by the detector system. For intermediate signal intensities, ca. 30 kcps 3 Mcps, 10 13 Ω Amplifier Technology is uniquely able to deliver precisions approaching the theoretical limits of counting statistics. ion counters, such as the SEM, are recommended for the lowest signal intensities. 207 Pb/ 206 Pb 2.10 10 13 Ω Amplifier Technology 2.08 2.06 2.04 2.02 2.00 0.81 0.82 0.83 0.84 0.85 207 Pb/ 206 Pb T1-G StHs/680-G GOR132-G ATHO-G Pb isotope ratios of MPI-DING reference glasses measured by LA-MC-ICP-MS. Top: 206 Pb, 207 Pb and 208 Pb measured using 10 11 Ω amplifiers. Bottom: 206 Pb and 207 Pb measured using 10 13 Ω Amplifier Technology with tau correction. 13

Multicollector Software Suite v3.30 10 13 Ω Amplifier Technology made easy The Neptune XT MC-ICP-MS is supported by a new software release. 10 13 Ω Amplifier Technology is enhanced by online tau correction, which makes 10 13 Ω Amplifier Technology as easy to use as standard Faraday cup amplifiers. Also supported is a new gain calibration option. Until now, without additional offline corrections, the different detector response rates between 10 13 Ω Amplifier Technology and 10 11 Ω amplifiers, or ion counters, has limited the accuracy and precision that could be achieved for measurements with variable signal intensities (e.g. from laser ablation). Online tau correction now corrects for the different detector response rates, delivering accuracy and precision. Enhanced productivity Productivity is further enhanced by new features for the setup of long measurement sequences using Sequence Editor. With just a few clicks a long sequence of measurements can be created, including sample-standard bracketing and blank corrections. Online tau correction of signals from laser ablation Pb isotopic measurements. top: uncorrected, bottom: tau corrected. The different response rates of the amplifiers are corrected for by selecting the tau correction option in the software. 14

15

Multicollector Software Suite Comprehensive software for MC-ICP-MS & TIMS The Thermo Scientific Multicollector Software Suite supports scientific productivity by providing all the necessary tools for running the instrument, from setup through to results. Tune fully automated instrument startup; straight forward control of tuning parameters and collector positioning; clear display of signal traces. Method Editor customizable data acquisition parameters; drag and drop isotope ratio builder with built-in mass bias and interference corrections; formula editor for custom corrections. Sequence Editor new quick setup feature for creating long measurement sequences; fully automated sequencing of methods; automated collector positioning when switching between applications; blank corrections and sample-standard comparison (delta values); online export of data; automated instrument shutdown. Data Evaluation raw data and calculated results are displayed in spreadsheet or graphical form; evaluation parameters such as tau correction can be toggled on or off, and the data re-evaluated; raw and calculated results can be exported to a variety of data formats for further data interrogation in third party programs. Find out more at thermofisher.com/mc-icp-ms 2018 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Technologies of the Neptune XT are covered by US patents, for further information visit: https://www.thermofisher.com/us/en/home/industrial/mass-spectrometry/virtual-patent-marks-inorganic-mass-spectrometry.html BR30536 EN-0718G