We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

Similar documents
We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

VGA-100 Instrument Detection Limits and Linearity

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

Automated PIONA Analysis by ASTM D8071 and VUV PIONA+

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Permanent Gas Analysis by Gas Chromatography Vacuum Ultraviolet Spectroscopy

Innovations In Optics. Zaheer Juddy - AIMS

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Multi-residue analysis of pesticides by GC-HRMS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Introduction. Chapter 1. Learning Objectives

Identifying Disinfection Byproducts in Treated Water

ChromTech HPLC System

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Automated and accurate component detection using reference mass spectra

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Introduction to Fourier Transform Infrared Spectroscopy

The Theory of HPLC. Quantitative and Qualitative HPLC

High Pressure/Performance Liquid Chromatography (HPLC)

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Varian Galaxie Chromatography Data System for Preparative HPLC

Title Experiment 7: Gas Chromatography and Mass Spectrometry: Fuel Analysis

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

IR-LC Deposition and Detection System. Polymer Deformulation and Additive Analysis by a Single GPC-IR Run

Deposition and Detection System. Trace Level Analysis of Chemical Warfare Agents (CWAs) Related Chemicals by GC-IR Solid Phase System

Introduction to Fourier Transform Infrared Spectroscopy

Chapter 31 Gas Chromatography. Carrier Gas System

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

IN QUALITATIVE ANALYSIS,

Discover what you re missing

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Understanding Your Spectra Module. Agilent OpenLAB CDS ChemStation Edition

Agilent G2350A Atomic Emission Detector (AED)

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

UV3000. Accurate, precise, and portable ambient gas point analyzer

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

UNIQUE SOLUTION FOR FLAVOUR AND FRAGRANCE IDENTIFICATION BY MEANS OF GC-MS (TOF) / CONDENSED PHASE FTIR

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances KEYWORDS

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Agilent All Ions MS/MS

Finnigan LCQ Advantage MAX

High Throughpu[ Separations and Structural Information Achieved with Automated LC/MS. Michael P. Balogh, Matthew J. Dilts Waters Chromatography

MassHunter Software Overview

ACD/Labs Software Impurity Resolution Management. Presented by Peter Russell

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Lab 11: Must what goes in be the same as what comes out? Spectroscopy & Fluorescence in Chlorophyll.

Jack Cochran, Lindsey Shear-Laude, Alex Hodgson VUV Analytics Emerald Conference. #emeraldconference

Contaminant profiling: A set of next generation analytical tools to deal with contaminant complexity

MassHunter TOF/QTOF Users Meeting

Pulsar. Delivering NMR to your benchtop

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles

Fourier Transform Infrared Spectrometry Prelab Last modified: June 17, 2014

Gas Chromatography (GC)

HYPHENATED TECHNOLOGY GUIDE

Automated Characterization of Compounds in Fire Debris Samples

Evolved gas analysis by simultaneous thermogravimetric differential thermal analysis-fourier transformation infrared spectroscopy (TG-DTA-FTIR)

Analysis of complex petrochemicals by GC GC TOF MS with Select-eV variable-energy electron ionisation

Spring 2010 updated March 24 Determination of Aromatics in Gasoline by Gas Chromatography- Mass Spectrometry: Comparison of Grades and Brands

Routine MS Detection for USP Chromatographic Methods

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

The Claviature of Gas Analysis

HYPHENATED TECHNOLOGY GUIDE

Atomic Absorption Spectroscopy (AAS)

Expectations for GC-MS Lab

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

A DIVISION OF ULVAC-PHI. Time-of-Flight Secondary Ion Mass Spectrometer with Parallel Imaging MS/MS for Confident Molecular Identification

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

High Performance Liquid Chromatography

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Deconvolution of Overlapping HPLC Aromatic Hydrocarbons Peaks Using Independent Component Analysis ICA

Luminescence transitions. Fluorescence spectroscopy

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

QuantumMCA QuantumNaI QuantumGe QuantumGold

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

The Analysis of Organophosphate Pesticides by LC/MS Application

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Introduction to Chromatographic Separations

U.S. EPA Method 8270 for multicomponent analyte determination

SIFT-MS. technology overview

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

3) In CE separation is based on what two properties of the solutes? (3 pts)

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

SPECTROPHOTOMETERS. Visible and UV-Visible

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Fourier Transform Infrared Spectroscopy Postlab Last modified: June 17, 2014

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Theory and Practical Consequences.

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Transcription:

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative. gas chromatography detector

Everything you need in one GC detector Universal and selective detector with sensitive linear response for accurate quantitation Fast detector response First-principal technique drastically reduces calibration issues Easy to operate and maintain, no vacuum pumps required Unambiguous compound identification and quantitation, including isomers Excellent temporal resolution No ionization means minimalsample degradation Resolve co-eluting analytes and quit worrying about trying to achieve baseline resolved chromatography The VUV detector will be used as a universal, calibration-free tool that provides the relative quantitative values of distinct molecules in mixtures in a rapid manner.

Meet the alternative M M* M gas chromatography detector LUIGI MONDELLO Chair of ISCC and GCxGC Conference in Riva del Garda and Professor, University of Messina, Italy

Gas Chromatography detection in a whole new light All gas phase molecules absorb strongly in the vacuum ultraviolet region, yet application of VUV absorption technology to analytical detection and measurement has not been addressed until now. Our patented and proprietary technologies enable the most exciting advancement in GC detection in decades, by making the unique properties of the vacuum ultraviolet region available to the chromatographer for the first time. The VGA-100 is a universal mass-sensitive gas chromatography detector that provides both qualitative and quantitative data. The strong absorption of gas phase molecules in the VUV provide excellent sensitivity, and the compound-specific absorption spectra provide unparalleled selectivity. One thing that I really like about VUV is that it can be considered a universal detector but with the advantage of being familiar to us. We all used UV spectrometers in school.

An analytical solution for every industry VUV spectra of VOCs: The VGA-100 resolves product-related isomers and characterizes process impurities. Fatty acid methyl ester VUV spectra: Process and quality control testing is straightforward using VGA-100 automated analysis. Terpene VUV spectra: VGA-100 easily differentiates flavor and fragrance isomers while providing their relative concentrations. NICHOLAS SNOW Professor, Seton Hall University, New Jersey, USA

Discover the benefits of VUV Absorption spectroscopy is a well-understood analytical detection technique offering a wide range of uses. Measured wavelength ranges from the ultraviolet through the infrared are commonly used for gas and solution phase applications. VUV Analytics has extended the usefulness of the absorption spectroscopy in the vacuum ultraviolet region for the first time ever. A region which was previously limited to synchrotrons, capable of overcoming the environmental challenges. VUV absorbance spectra of overlapping xylene isomers Most gas phase molecules exhibit strong and unique absorption spectra in the VUV region, including many isomers. The measured spectra can be matched against an existing compound specific absorption cross section library to rapidly identify the compounds. This fitting routine also provides the ability to deconvolve co-eluting peaks, providing a unique orthogonal separation approach. Deconvolution of the overlapping chromatographic signals for m- and p-xylene VUV spectroscopy adds a dimension that is complementary to mass spectrometry, offering selectivity that is difficult to otherwise obtain.

Fuel analysis simplified Hydrocarbon mix chromatogram. Inset shows how VUV Analyze identifies peaks by compound class based on their spectral response. The VGA-100 significantly simplifies PIONA compound analysis in finished gasoline. The VUV absorption spectra demonstrate obvious class similarities, allowing for simplified compound class separation. HANS-GERD JANSSEN Professor, University of Amsterdam and Science leader, Unilever Research Vlaardingen, the Netherlands

Easy to set up, Easy to use Intuitive Chromatography Software Written by Chromatographers for Chromatographers VUVision software simplifies GC analysis by providing an intuitive interface for analyte characterization by VUV spectroscopy. VUVision delivers straightforward workflows for acquiring and processing data, resulting in high automation confidence and low-risk of analytical error. VUVision is the base software for system control, data acquisition, library searching, qualitative analysis, calibration, and quantitative analysis by external or internal standard methods. It is intended for both manual post-processing and automated analysis driven by VUV Analyze TM. This robust software solution delivers standard chromatographic capabilities and data analysis while providing spectral information that is unique to VUV spectroscopy. Home Screen workflow: VUVision provides a straightforward workflow for processing and analyzing data. The VUV detector is a powerful new tool in the GC toolbox.

Powerful and easy-to-understand analysis tools Data View / Review Data View / Review performs qualitative analysis of either currently running acquisitions or previously acquired runs. It is especially useful in analyzing unknown samples using the VUV Auto Qual feature, which provides best fit identification based on VUV library compound matching. Specific peaks or areas of interest can be highlighted for compound identification through VUV spectral library fitting. Data View / Review: Regions of interest can be selected and analyte spectra fit with VUV library compounds. Auto Qual Report: Auto Qual provides best guess compound identification of unknowns using VUV library compound fitting. A report is generated detailing the chromatographic, spectral, and closest compound match for each peak detected. KEVIN SCHUG Distinguished Professor of Analytical Chemistry, University of Texas at Arlington

Excellent sensitivity and linearity The VGA-100 delivers superior performance with low picogram detection limits. The terpene instrument detection limits (IDLs) shown below demonstrated R 2 >0.99 across three orders of magnitude. TERPENES ANALYTE RETENTION TIME (Minutes) IDL (pg) LINEAR DYNAMIC RANGE (pg) R 2 λ INTEGRATION RANGE (nm) α-pinene 3.3 25 20-50000 0.9982 140-160 gamma-terpinene 4.5 15 20-50000 0.9972 140-160 Geraniol 6.4 25 20-50000 0.9972 140-160 α-bisabolol 9.9 45 20-50000 0.9957 140-160 An amazingly simple concept extended into a powerful spectral region.

PARAMETER VUV ANALYTICS VGA-100 NOTES Light Source Wavelength Range Wavelength Accuracy Wavelength Reproducibility Type of Response Spectral Bandwidth Maximum Acquisition Rate Data Collection Interval Response Characteristic Measurement Output Detected Species Typical IDLs (pg on Column) Linear Range Temperature Range Carrier Gases Makeup gas Flow Cell Dimensions Instrument Dimensions Deuterium Lamp Lifetime (hours) Weight Power Input Voltage Power Consumption Operating System Additional Facilities Requirements Deuterium lamp 120-240 nm ±0.2 nm 0.05 nm Universal <1 nm >90 Hz 11 ms Absorption versus Wavelength Identity, Concentration All compounds and classes alpha-pinene: 30 Methyl Decanoate: 30 Fluorene: 35 Coumarin: 35 n-decane (C10): 40 Phenylacetaldehyde: 40 Citronellol: 65 3-4 orders Ambient - 300 C H 2, N 2, or He Ar, He, N 2 10 cm pathlength, <80 µl cell volume 30 x 13 x 17, or 76.2 x 33 x 43.2 cm >2000 120lbs, or 54.4kg 100/240V <700 VA Windows 7 Professional SP1, Windows 8.1 CDA connection 99.999% N 2 connection, typical 40 ml/min purge requirement *H 2, He, Ar are transparent *H 2, He, Ar are transparent Lamp intensity half life at 250 nm TIM HOSSAIN, PH.D. Chief Scientist, Cerium Laboratories

science in a new light vuv analytics, inc. 715 discovery blvd., ste 502, cedar park, tx 78613 512.333.0860 www.vuvanalytics.com