Scintillators for photon detection at at medium energies

Similar documents
Dedicated Arrays: MEDEA GDR studies (E γ = MeV) Highly excited CN E*~ MeV, 4 T 8 MeV

Studies of Hadron Calorimeter

Measurement of the η-mass from the reaction γp pη in threshold region

David Gascón. Daniel Peralta. Universitat de Barcelona, ECM department. E Diagonal 647 (Barcelona) IFAE, Universitat Aut onoma de Barcelona

Dual readout with tiles for calorimetry.

Sven Schumann. DPG Spring Meeting

IMP's activities in COSY programs and the extension to HPLUS

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

Particle Detectors A brief introduction with emphasis on high energy physics applications

Charged particles detectors Arrays (1)

Hadron structure with photon and antiproton induced reactions - QCD in the non-perturbative range -

Calorimetry in particle physics experiments

Recoil Polarisation Measurements in Meson Photoproduction

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl

Identification of Central Production in the π + π π + π Channel at COMPASS

EXPERIMENTAL STUDY OF NEUTRON FIELDS PRODUCED IN PROTON REACTIONS WITH HEAVY TARGETS. Nuclear Physics Institute AS CR, Rez Czech Republic

THE FORWARD DETECTOR OF THE ANKE SPECTROMETER. SCINTILLATION AND CHERENKOV HODOSCOPES

Status / Hadron Spectroscopy at COMPASS

Simulation and data analysis with the BGO-OD experiment

Measurement of the η mass by the NA48 Experiment

Decay-Pion Spectroscopy of Λ-Hypernuclei at MAMI

Future gamma-ray spectroscopic experiment (J-PARC E63) on 4 ΛH

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Calorimetry I Electromagnetic Calorimeters

Kaon Identification at NA62. Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

New Results from the DREAM project

Fast inorganic scintillators - status and outlook -

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Dual-Readout Calorimetry with a Mo-Doped PbWO4 Electromagnetic Section

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

First experiments with the polarized internal gas target at ANKE/COSY

Measurements of liquid xenon s response to low-energy particle interactions

Information about the T9 beam line and experimental facilities

Particle Identification of the LHCb detector

and ' Time-like Transition Form Factors from MAMI

Week 6: Ch. 8 Scintillation Counters

Status of the data analysis on KK pair production

Detector technology. Aim of this talk. Principle of a radiation detector. Interactions of gamma photons (gas) Gas-filled detectors: examples

Strangeness photoproduction at the BGO-OD experiment

Precision Polarimetry at JLab, 6 GeV Era G. B. Franklin Carnegie Mellon University

Threshold photoproduction of J/y with the GlueX experiment. Lubomir Pentchev Jefferson Lab for the GlueX collaboration

Test setup, APDs,, preamps Calibration procedure Gain monitoring with LED Beam test results Future R&D options

Optical transmission radiation damage and recovery stimulation of DSB:Ce 3+ inorganic scintillation material

STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT

Theory English (Official)

Hadronic Showers. KIP Journal Club: Calorimetry and Jets 2009/10/28 A.Kaplan & A.Tadday

Study of Isospin simmetry using the PARIS detector. Alice Mentana

Modifications of the D33(1700) resonance in the nuclear medium

Concepts of Event Reconstruction

Digital Imaging Calorimetry for Precision Electromagnetic and Hadronic Interaction Measurements

Alpha particle scintillation detector based on micro pixel avalanche photodiode and LYSO crystal

The PANDA experiment at FAIR

The reaction p(e,e'p)π 0 to calibrate the Forward and the Large Angle Electromagnetic Shower Calorimeters

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Compton Scattering from Light Nuclei at MAX-lab. Luke Myers Collaboration

Scintillation Detectors

First measurements of final state neutron polarisation in deuterium photodisintegration. Stephen Kay University of Edinburgh. NP Summer School 2015

NA62: Ultra-Rare Kaon Decays

ISOSPIN RESOLVED DOUBLE PION PRODUCTION AT CELSIUS

Helicity Dependent Cross Sections in Meson Photoproduction off Quasi-Free Protons and Neutrons

The Excitation Function of the Omega Meson in Medium

Calibration and Monitoring for Crystal Calorimetry

Simulation study of scintillatorbased

Scintillation Detectors

Compton suppression spectrometry

The π 0 Lifetime Experiment and Future Plans at JLab

Simulation studies of the PANDA detector at GSI

Scintillation Detectors

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Status of the LHCb RICH and hadron particle identification

MC Benchmarks for LAr Instrumentation in GERDA

Detection of γ-rays from nuclear decay: 0.1 < E γ < 20 MeV

The Mainz Microtron MAMI

Development of a neutron time-of-flight source at the ELBE accelerator

SCINTILLATION DETECTORS AND PM TUBES

Simulation for Proton Charge Radius (PRad) Experiment at Jefferson Lab1 Li Ye Mississippi State University For the PRad Collaboration The Proton Charg

Last Lecture 1) Silicon tracking detectors 2) Reconstructing track momenta

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

Flux and neutron spectrum measurements in fast neutron irradiation experiments

CLAS12 at Jefferson Lab

Radioactivity and Ionizing Radiation

A New Microchannel-Plate Neutron Time-of-Flight Detector

Particle Identification: Computer reconstruction of a UA1 event with an identified electron as a candidate for a W >eν event

Future prospects for the measurement of direct photons at the LHC

Fast-Neutron Production via Break-Up of Deuterons and Fast-Neutron Dosimetry

DIPOLE-STRENGTH IN N=50 NUCLEI STUDIED IN PHOTON-SCATTERING EXPERIMENTS AT ELBE

positron source EPOS - general concept - timing system - digital lifetime measurement

Scintillators General Characteristics

Cross section measurements of the elastic electron - deuteron scattering

Time Structure in Dual Readout Calorimeters. Michele Cascella (UCL) for the RD52 Collaboration 1

REVIEW OF CRYSTAL CALORIMETERS

Status and Perspectives of Hadron Physics in Europe. Forschungszentrum Jülich in der Helmholtz-Gemeinschaft

Particle Energy Loss in Matter

SiPM & Plastic Scintillator

Dual-Readout Calorimetry Simulations

M.Battaglieri Istituto Nazionale di Fisica Nucleare Genova - Italy. A Forward Photon Tagging Facility for CLAS12

Photons: Interactions

Determination of the η -nucleus optical potential

PHY492: Nuclear & Particle Physics. Lecture 25. Particle Detectors

Transcription:

Scintillators for photon detection at at medium energies R.Novotny II.Physics II.Physics Institute, Institute, University University Giessen, Giessen, Germany Germany and and for for the the TAPS TAPS and and CRYSTAL CRYSTAL CLEAR CLEAR collaborations collaborations experimental requirements at medium energies comparison BaF 2, CeF 3 and PbWO 4 photon response particle identification/discrimination time-of-flight pulse-shape analysis phoswich technique particle response conclusions and outlook CeF 3 BaF 2 PWO

experimental requirements at at medium energies < 1-2 GeV low cross sections compact set-up dense material detection of low and high energy photons good energy resolution sufficient luminescence low cross sections high count rates fast scintillator high multiplicity of neutral/charged particles fast scintillator pulse-shape sensitivity time-of-flight PSA

relevant properties of of the investigated crystal scintillators crystal BaF 2 CeF 3 PWO density (g/cm 3 ) 4.88 6.16 8.28 radiation length (cm) 2.3 1.77.89 Moliere radius (cm) 3.4 2.6 2. luminescence (nm) 31 195, 21 33 42 decay time (ns) 62.6 3 5-15 relative light output comp. to NaI(Tl).2.5.1.1

counts experimental technique: energy marked photons R T M 2 full spectrum of the Bremsstrahlung @ MAMI, Mainz counts counts 1 3 1 2 R T M 1 R T M 3 linear accelerator 3 accelerator stages 1 counts 1 3 1 2 59 MeV 1 MeV 14 MeV 18 MeV 298 MeV due to coincidence with tagger scintillators 1 5 1 15 2 energy photons photons 45 MeV 599 MeV 1 79 MeV 1 5 1 15 2 energy /a.u. energy bins: DE ~ 1-2 MeV electron beam 855 MeV radiator

photon response: BaF 22 σ E 137 [ 662keV, Cs] = 4.9% (15.1%) fast: 195, 21 nm slow: ~ 31 nm s / E TAPS detector: 12X 59mm Ø fast slow σ E [ 1 GeV] = 5.1% photon energy / GeV shower leakage! lineshapes measured with tagged photons

photon response: CeF 33 P1 P2 P3 P4 P5 P6 each tower consists of 2-4 elements total length ~ 4mm ~ 25 X o individually wrapped read-out with PM-tubes 3x3mm 2 1 transmission [%] 8 6 4 CeF 3 #5 2 25 35 45 55 E g =54.6 MeV s/e=11.5% wavelength [nm] counts / a.u. 35 3 25 2 15 1 5 E γ = 55 MeV 227 MeV 48 MeV experiment 769 MeV 2x2mm 2 GEANT 2 4 6 8 1 energy / MeV

photon response: CeF 33 E.Auffray et al. NIM A378(1996)171 e, µ, p: 1 15 GeV/c s/e ~.5% @ 5 GeV with Si PD read-out 12 CeF 3 - Array s/e [%] 1 8 σ E = 2.17% E[GeV] + 2.7% 6 4,,1,2,3,4,5,6,7,8 photon energy [GeV] in collaboration with: P.Lecomte et al., CC-Collaboration

photon response: PbWO 44 lineshape 1 ns digital scope: Tektronix TDS 744A E g ~ 4 MeV recorded after 5 m RG58 cable K 1ns 1µs = yield yield > 96.5% no significant slow decay components

photon response: PbWO 44 response to low energy g - sources pwo 158 tapered 98/1/2 12.5 pwo 158 tapered 98/1/2 12.27 1 8 137 Cs 662 kev 45 4 35 3 6 Co ~1.25 MeV 6 4 s/e ~ 3% 25 2 15 s/e ~ 25% 2 1 5 5 1 15 2 25 3 35 4 45 1 2 3 4 5 6 Narrow light output [a.u.] Narrow PM: R259-1

photon response: PWO:Tb, PWO:Mo enhanced luminescence by selected doping optical transmission 8 7 Tb-PWO Nb/La-PWO 14 137 Cs (662keV) 12 Tb-PWO 6 5 4 3 2 Nb/La-PWO Mo-PWO counts [a.u.] 1 8 6 4 Mo-PWO photopeak position [a.u.] 1 3 35 4 45 5 55 6 wavelength [nm] 35 3 25 2 15 1 5 137 Cs (662 kev) Mo-PWO Tb-PWO Nb/La-PWO,,5 1, 1,5 2, 2,5 3, 3,5 4, 4,5 5, integration gate [ms] 2 5 1 15 2 25 3 35 4 45 5 energy [a.u.] increased light-yield but: longer integration time

photon response: PbWO 44 determination of the luminescence yield using hybrid photodiodes # 158 Nb/La-PWO #315 Sb-PWO plastic scintillator 6 Co g -source counts 1 3 ID Entries Mean RMS 1 32751 518.4 366.3 1 2 test crystal 1 < p.e.>=5. < p.e.>=5.3 HPD 1 delivered by: Bogoroditsk TCP delivered by: Shanghai SICCAS 25 5 75 1 125 15 175 2 test set-up light-output [a.u.]

photon response: PbWO 44 determination of the luminescence yield using hybrid photodiodes samples 24 22 2 18 16 14 12 1 8 6 4 2 2 3 4 5 6 7 8 9 1 light output /p.e. first matrix Nb doped Nb/La square Nb/La tapered Shanghai BGRI 32x32 RINC 32x32 prototypes for Proton Ball @ANKE

photon response: PbWO 44 experimental set-up cooled T ~ 6 o C 5x5 matrix electrons photons 5-85 MeV plastic veto photomultiplier read-out Philips XP1911 or Hamamatsu R4125 (19 mm ) DAQ : individual processing of energy and time information using commercial CAMAC electronics.

2.5 x 2.5 mm photon response: PbWO 2 44 22.7 x 22.7 mm 2 E g = 45-77 MeV @MAMI a ~.4 o 15 mm delivered by: Bogoroditsk TCP counts 2 15 1 5 E g =45.4 MeV s/e=7.4% 1 E g =15.6 MeV 8 6 4 2 s/e=5.3% 5 1 15 2 5 1 15 2 25 3 35 4 45 energy / a.u. improved resolution below 15 MeV in spite of reduced PM-coverage of the crystal endface no correction for finite energy bin (1.2 2.5MeV) s 141. % = + E E[GeV] 9. %

particle response: BaF 22 fast timing signal time resolution: s t > t 85 85 ps ps optimum time resolution in spite of large crystal size! time-of-flight / ns 2 AGeV Ca+Ca particle identification energy / MeV

particle response: BaF 22 proton time plastic VETO BaF 2 -detector photon E-fast photons all events fast component protons total light output E-total signal integration width pulse-shape sensitivity reaction products: 2 AGeV Ar + Ca charged events protons neutral events photons n

particle response: BaF 22 charged particle time E-fast p d t photons fast component total light output signal integration width E-total phoswich: plastic/baf 2 BaF 2 -detector plastic scintillator common PM-read-out

neutron response: BaF BaF 2 2 identification: time-of-flight, plastic VETO, PSA neutron efficiency depends strongly on energy and detector threshold E n < 3 MeV: neutron identification via exclusively measured reaction g + p p + p + + n efficiency: E n > 75 MeV 17%

experimental tests of of charged particle response COSY @ FZ Jülich target 5x5 matrix protons p = 2. GeV/c secondary target charged reaction products µ plastic scintillator 5x5 matrix TOF start detector plastic scintillator cooled T ~ 11 o C TOF start detector TOF distance: 2.9 m 1.2 GeV p + Al Al measurement: measurement: energy, energy, TOF TOF of of charged reaction products particle ID ID (p (p +/- +/-,, p, p, d, d, t, t, e +/- +/- )) energy response

charged particle response: 1.2 1.2 GeV p + Al Al @COSY time-of-flight relative to photons / ns p proton calibration t d p MIP counts p E p = 5 MeV 16 d t π energy / MeV E p = 2 MeV p d counts hadrons deposited energy / MeV MIP E.M.shower MIP proton calibration s/e % 12 8 4 protons deuterons pions multiplicity E.M.shower due to e +/- total energy / MeV photon response 5 1 15 2 25 3 energy / MeV

PWO matrix response: 1.2 GeV p + Al Al @COSY counts <M> ~1.5 high multiplicity events M > 3 multiplicity Multiplicity below the values obtained for EM-showers: <M> = 5.6 @ 45 MeV <M> = 18.4 @77MeV E threshold = 5 kev all kinematical correlations disappeare!

pion response of of PWO: 1.2 GeV p + Al Al g proton calibration @COSY γ = ( 1 β 2 ) 1 = E m kin + 1 p proton-calibration fails! K MIP p d deposited energy / MeV quenching effects? p / p ~ 3 / 1 energy determined from TOF / MeV 6 E tof = E dep. 45 3 15 E(tof)=16.3+.3*E(dep) 2 4 6 8 1 12 14 16 deposited energy (proton calibration) / MeV

pion response of of PWO: 1.2 GeV p + Al Al @COSY indication of pulse-shape sensitivity excitation density dependence of the emission spectrum (excitation with 1eV photons) exp. sensitivity: integration gate QE of PM time-resolved emission spectra at different excitation energies I.A.Kamenskikh et al., Proc. SCINT97, p.195

experimental tests of of charged particle response AGOR@KVI, Groningen target foil (C, CH 2 ) active collimator protons E = 85 MeV charged reaction products vacuum chamber 85 85 MeV p + C, C, CH 22 measurement: measurement: energy energy of of scattered protons protons energy response of of BaF BaF 2, 2, CeF CeF 3 and 3 and PWO

experimental tests of of charged particle response individual detector: particle impact selected by active collimator (plastic scintillator BC 48) AGOR@KVI, Groningen p+c plastic collimator PM collimator PM p+ch 2 light-tight housing collimated events

proton response: 85 85 MeV p + CH 22,C,C @KVI comparison: CeF 3 BaF 2 PWO PWO:Mo 2 12 counts 15 1 CeF 3 2 x 2 x 14 cm 3 8 BaF 2 TAPS geometry 25 cm counts counts 15 1 CeF 3 2 x 2 x 14 cm 3 6 4 BaF 2 TAPS geometry 25 cm 5 4 5 2 1 2 3 4 5 6 7 8 9 1 15 1 PbWO 4 2 x 2 x 15 cm 3 1 2 3 4 5 6 7 8 9 1 8 PbWO 4 :Mo 1.5 x 1.5 x 1.5 cm 3 1 PbWO 4 2 x 2 x 15 cm 3 75 5 PbWO 4 :Mo 1.5 x 1.5 x 1.5 cm 3 5 4 5 25 1 2 3 4 5 6 7 8 9 1 1 2 3 4 5 6 7 8 9 1 proton energy / MeV 1 2 3 4 5 6 7 8 9 1 proton energy / MeV proton energy / MeV 1 2 3 4 5 6 7 8 9 1 85 MeV p + C 85 MeV p + CH 2

proton response: 85 85 MeV p + CH 22,C,C @KVI s / E % 2 16 12 8 4 PWO 2 x 2 x 15 cm 3 PWO 3 x 3 x 12 cm 3 PWO 3 x 3 x 12 cm 3 PWO:Mo 1.5 x 1.5 x 1.5 cm 3 CeF 3 2 x 2 x 14 cm 3 CeF 3 3 x 3 x 13.2 cm 3 BaF 2 TAPS 25 cm 4 6 8 1 energy / MeV PWO PWO:Mo CeF 3 BaF 2

proton response: comparison BaF 22 CeF 33 PWO s / E / % 5 4 3 2 1 BaF 2 #1 BaF 2 #2 photon response s / E / % 14 12 1 8 6 4 2 CeF 3 #1 CeF 3 #2 photon response,2,4,6,8,1 energy / GeV,2,4,6,8,1 energy / GeV s / E / % 18 16 14 12 1 8 6 4 2 photon response matrix response PWO 2x2 cm 2 PWO 3x3 cm 2 PWO 3x3 cm 2 PWO:Mo 1.5x1.5 cm 2,2,4,6,8,1 energy / GeV

s/e / % s / E % 14 13 12 11 1 9 8 comparison of of photon and particle response CeF 3 PbWO 4 BaF 2 fast / total 7 6 5 4 3 2 1,,1,2,3,4,5,6,7,8,9 1, 1,1 2 16 12 8 4 photon energy / GeV PWO CeF 3 BaF 2 5 1 15 2 25 energy / MeV PWO:Mo CeF 3 PWO BaF 2 photon response σ E = A E / GeV BaF 2 CeF 3 PWO photons A / %.59 2.17 1.41.79 B / % 1.91 2.7.9 1.8 s/e / % 662keV 4.9 <3 5 MeV 4.5 11.6 7.3 1 GeV 2.5 4.9 1.8 2.6 protons A / %.97 B / % 3.33 s/e / % 8 MeV.9 1.6 5.5 time-of-flight s / ps 85 <17 <13 + B

Apparatus for studies of Nucleon and Kaon Ejectiles outlook outlook one of the internal beam facilities of COSY up-grade up-gradeby byaanew newphoton photonball ball to todetect detect neutral neutralmesons mesons in incoincidence: coincidence: complete completemeasurements measurements magnetic spectrometer 3 C-shaped dipoles D2: spectrometer magnet ramped synchronously with COSY during accelerating phase the theparticle particlespectrometer spectrometer ANKE@COSY ANKE@COSY

technical constraints limited space in the target region compact design dense detector material operation in the magnetic strayfield of D2 field strength.2 Tesla field vectors point in various directions detector requirements good energy resolution up to E g = 2 GeV crystal length 12 X position resolution high granularity large solid angle 3p background suppression fast response fast read-out with PM on-line charged particle discrimination future option: stand alone 4p-device 12cm PbWO 4 R 555 soft iron cylinder thickness 3mm signal amplitude [a.u.] 5 4 3 2 1 beam 7 U b = -195V orientation R = 6 1mm shielding 2mm shielding 2 4 6 8 1 12 magnetic field [Gauss] PM signal [a.u.] ramping of D2: up to 1.6 Tesla operation time [Dt=1s]

presented for the TAPS and Crystal Clear collaborations W.Döring, M.Hoek, V.Metag, K.Römer II. Physikalisches Institut, Universität Giessen A.Hofstaetter I. Physikalisches Institut, Universität Giessen R.Beck Institut für Kernphysik, Universität Mainz V.Hejny, H.Ströher Institut für Kernphysik, FZ Jülich M.Korzhik RINC, Minsk, Belarus research has been supported by BMBF, DFG, FZ-Jülich