Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Similar documents
Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

LC-MS/MS Analysis of Phytocannabinoids and their

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Determination of urea in ultrapure water by IC-MS/MS

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Translational Biomarker Core

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Supporting Information. Sweetened Swimming Pools and Hot Tubs

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Mass Spectrometry in MCAL

Because of its high sensitivity and selectivity, liquid

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Definitive EtG/EtS LC-MS/MS Analysis:

Taking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline

CHROMATOGRAPHY AND MASS SPECTROMETER

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Abstract. Experimental Sample Preparation

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Supporting Information

Routine MS Detection for USP Chromatographic Methods

2,5-DIMETHOXY-4-IODOPHENETHYLAMINE Latest Revision: August 22, 2005

Technical Note. Introduction

Highly sensitive quantitative estimation of genotoxic impurities from API and drug formulation using LC/MS/MS

Thermo Finnigan LTQ. Specifications

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Conc n of A OAs present (um) Conc n of B OAs present (um)

High Performance Liquid Chromatography

Determination of iopromide in environmental waters by ion chromatography-icp-ms

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Introduction to LC-MS

Calibrating Thermo Exactive with the Direct Analysis in Real Time (DART) Ambient Ionization Source (Protocol Adapted from US FDA FCC)

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry

M M e M M H M M H. Ion Sources

LC Technical Information

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Determination of trace anions in concentrated hydrofluoric acid

TANDEM MASS SPECTROSCOPY

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Introduction to the Q Trap LC/MS/MS System

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

A Simple SPE Method for the Determination of Malachite Green, Crystal Violet and Other Synthetic Dyes in Seafood

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

WADA Technical Document TD2003IDCR

An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening

Transcription:

38 Current Trends in Mass Spectrometry November 6 Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer This article demonstrates the improved robustness of a liquid chromatography tandem mass spectrometry assay achieved by utilizing the combined selectivity of high-field asymmetric waveform ion mobility spectrometry and highly selective reaction monitoring. James Kapron When analysts develop liquid chromatography mass spectrometry (LC MS) methods, they use reference standards to establish initial conditions. Applying these initial conditions to real-world biological samples presents significant challenges, including reduced signal-tonoise ratio (S/N). Biological matrices add interferences and contribute to reduced method selectivity. Bioanalytical scientists have many tools to solve selectivity problems that arise during method development. The three common classes of tools include MS, LC, and sample preparation. The easiest approach to increasing selectivity is changing the MS parameters. On triple-quadrupole mass spectrometers, changing parameters such as the ion-entrance voltages or m/z transitions might result in reduced sensitivity without an increase in selectivity. The only MS parameter that offers increased selectivity without significant loss in sensitivity is highly selective reaction monitoring (H-SRM). H-SRM results from the hyperbolic cross-section of the mass spectrometer s quadrupoles. The selectivity of the LC method can also be increased by changing the mobile phase (gradient, modifiers) or the stationary phase. These adjustments lead to the altering of all the associated method parameters (integration retention time window, column equilibration time, and so forth), making this a time-consuming endeavor. Modification of sample preparation procedures may include choosing between solidphase extraction (stationary phase, wash and elution solvents), liquid liquid extraction (extracting solvent, buffers), or simple solvent addition (protein precipitation, dilute-andshoot). Revisiting sample preparation wastes time and resources because the samples are already prepared and available for analysis. High-field asymmetric waveform ion mobility spectrometry (FAIMS) is a new tool for increasing LC MS method robustness. The technique separates gas-phase ions at atmospheric pressure. Desolvated ions enter the annular region between two concentric cylindrical FAIMS electrodes and are transported toward the mass spectrometer s entrance via a flow of clean, dry gas. Within the gas-filled region of the electrodes, the ions oscillate as a result of a waveform causing alternating high and low electric fields. The waveform is asymmetric; the high field is applied for one time unit followed by an opposite-polarity low field component applied for twice as long. Separation of ions during the two opposite polarity phases of the waveform is caused by behavior differences of the ions under the high- and low-field conditions. Over time, ions travel toward one or the other electrode. A low dc voltage compensates for this migration, resulting in a select ion subset being transmitted into the mass spectrometer. The magnitude of the so-called compensation voltage (CV) is compound dependent. Ions requiring a different CV for transmission are removed from the ion beam; thus, selectivity is achieved. The CV can be set to a constant value or stepped during an LC MS run to coincide with the

November 6 Current Trends in Mass Spectrometry 39 SN: 4.. 1. 1. 2. 2. 3. 3. 4. Figure 1: Representative LC SRM chromatogram for the analysis of norverapamil in human urine collected using unit mass resolution (.7 u in both Q1 and Q3). elution of specific analytes. High analyte transmission efficiency is achieved with this increase in selectivity by means of a unique ion-focusing mechanism arising from the cylindrical geometry of the FAIMS electrodes. This article describes the advantages of using LC, FAIMS, and H-SRM to improve bioanalytical robustness, using norverapamil in human urine as an example. Experimental Conditions Chemicals and reagents: Norverapamil hydrochloride and verapamil hydrochloride were purchased from Sigma-Aldrich (St. Louis, Missouri). HPLC-grade methanol and formic acid were acquired from VWR (Mississauga, Canada). All chemicals were used as received. Sample preparation: A -ml volume of human urine was fortified with analyte and internal standard to a final con- centration of pg/ml. This stock solution was treated with ml of.1% formic acid in water. The resulting solution ( pg/ml) was analyzed directly. Sample analysis: HPLC analyses were performed on a Finnigan Surveyor HPLC system (Thermo Electron). Samples were injected onto a mm 2.1 mm embedded polar group reversedphase column. The injection volume was L. The gradient LC method used mobile phases A (.1% formic acid in water) and B (::.1 methanol water formic acid) at a flow rate of.4 ml/min. The gradient was as follows (time, %B): (, ) (3, ) (4, ) (4.1, ) (, ). The entire LC effluent from the sample injections was directed to the Ion Max source on a TSQ Quantum Ultra mass spectrometer (Thermo Electron). MS conditions: Ion source and polarity: H-ESI, positive ion mode Spray voltage: + V Vaporizer temperature: 3 C Sheath gas: Nitrogen, psi Auxiliary gas: Nitrogen, psi Transfer tube temperature: C Transfer tube offset: V Tube lens offset: 1 V The transitions monitored were m/z 441. to m/z 1. for norverapamil and m/z 4. to m/z 1. for verapamil, each at a collision energy of 26eV and scan time of ms. The MS selectivity was regulated by setting Q1 resolution to a peak width of either.7 or.2 u full-width at half maximum (FWHM). Additional gas-phase separation before entry of ions into the mass spectrometer was achieved by including FAIMS in the analysis. FAIMS conditions: Dispersion voltage: V Outer bias voltage: V Compensation voltage: 16 V T inner electrode: C T outer electrode: C Gas flow rate: 2. L/min Gas composition: % helium in nitrogen Results and Discussion A representative LC SRM chromatogram for the analysis of norvera-

Current Trends in Mass Spectrometry November 6 SN: 2.. 1. 1. 2. 2. 3. 3. 4. Figure 2: Representative LC H-SRM chromatogram (.2 u in Q1). pamil in human urine collected using unit mass resolution (.7 u in both Q1 and Q3) is shown in Figure 1. Although LC MS-MS is a selective technique, many isobaric interferences appear in the chromatogram. These isobaric interferences increase the chemical background and may make reproducible integration of the analyte peak difficult. A representative LC H-SRM chromatogram (.2 u in Q1) is shown in Figure 2. H-SRM has removed most of the interferences. An even further increase in selectivity is achieved by utilizing FAIMS and H- SRM in the LC MS-MS analysis. Implementing FAIMS requires the establishment of conditions for the transmission of the desired analytes through the interface. Stable conditions for ion transmission are expressed by the CV. Figure 3 shows a CV scan during infusion of a norverapamil reference standard. The CV was ramped from to V in 1. min. The maximum response for norverapamil occurred at 16 V and indicated the appropriate CV for LC FAIMS H- SRM analysis. The structure of norverapamil is shown in the inset. Figure 4 shows a representative LC FAIMS SRM chromatogram for 4. 4. 3. Response (x ) 3. 2. 2. 1. 1... Compensation voltage (V) Figure 3: CV scan obtained during infusion of a norverapamil reference standard. The CV was ramped from to V in 1. min.

November 6 Current Trends in Mass Spectrometry 41 RT: 3.1 SN: 1371.. 1. 1. 2. 2. 3. 3. 4. Figure 4: Representative LC FAIMS SRM chromatogram for norverapamil in human urine. norverapamil in human urine. For this chromatogram, the FAIMS CV was set to 16 V. A comparison of this chromatogram with Figure 2 shows that these two techniques eliminated different interferences. Next, the combined selectivity of FAIMS and H-SRM was explored. To acquire an LC FAIMS H-SRM chromatogram for norverapamil in human urine, the FAIMS CV was set to 16 V and Q1 peak width was set to.2 u. A representative LC FAIMS H-SRM chromatogram for the analysis of norverapamil in human urine is shown in Fig- The increases in selectivity offered by the combination of FAIMS and H-SRM result in improved assay robustness. ure. The combined selectivity offered by FAIMS and H-SRM results in a cleaner chromatogram than the corresponding trace in Figures 1, 2, and 4. Very few interferences are transmitted. Although a factor of three was lost in absolute signal, the assay sensitivity, as defined by S/N, has increased five fold. Because complex biological samples are sprayed directly at the FAIMS interface, the robustness of the FAIMSenabled system was evaluated. Figure 6 shows peak areas resulting from samples of norverapamil in urine injected every

42 Current Trends in Mass Spectrometry November 6 SN: 1873 min over a three-day period. The %RSD for the analyses was 6.4%. Conclusions The increases in selectivity offered by the combination of FAIMS and H-SRM result in improved assay robustness. The cleaner chromatograms are more easily and more reproducibly integrated. For the analysis of norverapamil in urine, the new method was developed without having to revert to modification of the LC method or sample preparation steps. The use of LC FAIMS H-SRM over LC SRM reduced the chemical background and produced a fivefold increase in assay sensitivity. Other Reading (1) J.T. Kapron, M. Jemal, G. Duncan, B. Kolakowski, and R. Purves, Rapid Commun. Mass Spectrom. 19, 1979 1983 ()... 1. 1. 2. 2. 3. 3. 4. Figure : Representative LC FAIMS H-SRM chromatogram for the analysis of norverapamil in human urine. Jim Kapron is a strategic marketing specialist at Thermo Electron Corporation, Scientific Instruments Division, based in Ottawa, Ontario, Canada. E-mail: james.kapron@thermo.com.. 4. 4. 3. Area ratio 3. 2. 2. 1. 1... Injection number Figure 6: Peak areas resulting from samples of norverapamil in urine injected every min over a three-day period.