Magnetic Effect on Slip Flow of Blood through Porous Medium with Time Dependent Permeability, Pulsatile Pressure and Body Acceleration

Similar documents
MHD Pulsatile Slip Flow of Blood through Porous Medium in an Inclined Stenosed Tapered Artery in Presence of Body Acceleration

Effect of body acceleration on pulsatile blood flow through a catheterized artery

Pulsatile Flow of Couple Stress Fluid Through a Porous Medium with Periodic Body Acceleration and Magnetic Field

Effect of Magnetic Field on Blood Flow (Elastico- Viscous) Under Periodic Body Acceleration in Porous Medium

Mathematical Modelling of Blood Flow through Catheterized Artery under the Influence of Body Acceleration with Slip Velocity

Biomagnetic Steady Flow through an Axisymmetric Stenosed Artery

Analytical Solutions of Unsteady Blood Flow of Jeffery Fluid Through Stenosed Arteries with Permeable Walls

Radial Variation of Axial and Radial Velocity of Blood in Stenosed Artery in the Presence of Body Accelerations

Flow of a Casson Fluid Through an Inclined Tube of Non-uniform Cross Section with Multiple Stenoses

A Computational study of Bingham plastic flow of Blood through an artery by multiple stenoses and post dilatation

Simulation of Variable Viscosity and Jeffrey Fluid Model for Blood Flow Through a Tapered Artery with a Stenosis

Unsteady Flow of a Newtonian Fluid in a Contracting and Expanding Pipe

Effect of Periodic Body Acceleration in Blood Flow through Stenosed Arteries A Theoretical Model

Effects of Magnetic Field and Slip on a Two-Fluid Model for Couple Stress Fluid Flow through a Porous Medium

Department of Mathematics, Amrita Vishwa Vidyapeetham (University), Karnataka , India

Peristaltic Transport of a Magneto Non-Newtonian Fluid through A porous medium in a horizontal finite channel

MHD peristaltic transport of a micropolar fluid in an asymmetric channel with porous medium

STUDY OF BLOOD FLOW THROUGH MODELLED VASCULAR STENOSIS

INTERNATIONAL JOURNAL OF ADVANCE RESEARCH, IJOAR.ORG ISSN

Available online at Pelagia Research Library. Advances in Applied Science Research, 2012, 3 (6):

Effect of Magnetic Field on Flow Behaviour of Blood through A Modelled Atherosclerotic Artery

Modeling of non-newtonian Blood Flow through a Stenosed Artery Incorporating Fluid-Structure Interaction

CHAPTER 6 Effect of slip and heat transfer on the Peristaltic flow of a Williamson fluid in an incliped channel

Research Article Innovation: International Journal of Applied Research; ISSN: (Volume-2, Issue-2) ISSN: (Volume-1, Issue-1)

MHD OSCILLATORY SLIP FLOW AND HEAT TRANSFER IN A CHANNEL FILLED WITH POROUS MEDIA

Numerical Study of the Behaviour of Wall Shear Stress in Pulsatile Stenotic Flows

Oscillatory flow of a jeffrey fluid in an elastic tube of variable cross-section

Mathematical Modeling of Peristaltic Flow of Chyme in Small Intestine

Research Article Nonlinear Fluid Models for Biofluid Flow in Constricted Blood Vessels under Body Accelerations: A Comparative Study

Arterial Macrocirculatory Hemodynamics

Peristaltic flow of a Williamson fluid in an inclined planar channel under the effect of a magnetic field

arxiv: v1 [physics.flu-dyn] 16 May 2014

Suspension model for blood flow through a tapering catheterized inclined artery with asymmetric stenosis

Peristaltic pumping of couple stress fluid through non - erodible porous lining tube wall with thickness of porous material

Lattice Boltzmann Simulation of One Particle Migrating in a Pulsating Flow in Microvessel

Hydromagnetic Blood Flow through a Uniform Channel with Permeable Walls Covered by Porous Media of Finite Thickness

ROTATING OSCILLATORY MHD POISEUILLE FLOW: AN EXACT SOLUTION

Mathematical Models and Numerical Simulations for the Blood Flow in Large Vessels

PROBLEM SET 6. SOLUTIONS April 1, 2004

Mathematical modelling of blood flow through a tapered overlapping stenosed artery with variable viscosity

Mathematical modelling of physiological flows

MHD PERISTALTIC FLOW OF A COUPLE STRESS FLUIDS PERMEATED WITH SUSPENDED PARTICLES THROUGH A POROUS MEDIUM UNDER LONG WAVELENGTH APPROXIMATION

Modelling and simulation of micropolar fluid flow with variable viscosity through unhealthy artery

Study of blood flow through a catheterized artery

Navier-Stokes Flow in Cylindrical Elastic Tubes

Numerical Study of Steady MHD Plane Poiseuille Flow and Heat Transfer in an Inclined Channel

Influence of velocity slip conditions on MHD peristaltic flow of a Prandtl fluid in a non-uniform channel

Research Article FDM Analysis for Blood Flow through Stenosed Tapered Arteries

Numerical study of blood fluid rheology in the abdominal aorta

Magnetic effects on pulsatile flow of micropolar fluid through a bifurcated artery

SLIP EFFECTS ON MHD PERISTALTIC TRANSPORT OF A WILLIAMSON FLUID THROUGH A POROUS MEDIUM IN A SYMMETRIC CHANNEL. Andhra Pradesh, India

Shell Balances in Fluid Mechanics

Oscillatory MHD Mixed Convection Boundary Layer Flow of Finite Dimension with Induced Pressure Gradient

Peristaltic Transport of a Hyperbolic Tangent Fluid Model in an Asymmetric Channel

International Journal of Mathematical Archive-7(5), 2016, Available online through ISSN

REE Internal Fluid Flow Sheet 2 - Solution Fundamentals of Fluid Mechanics

Slip Effect on Peristaltic Transport. of Micropolar Fluid

Nonlinear Analysis: Modelling and Control, 2008, Vol. 13, No. 4,

Numerical Study of Blood Flow through Symmetry and Non- Symmetric Stenosis Artery under Various Flow Rates

Research Article Peristaltic Transport of a Jeffrey Fluid with Variable Viscosity through a Porous Medium in an Asymmetric Channel

MHD Free convection flow of couple stress fluid in a vertical porous layer

Effect of variable viscosity on the peristaltic flow of a Jeffrey fluid in a uniform tube

TECHNISCHE UNIVERSITEIT EINDHOVEN Department of Biomedical Engineering, section Cardiovascular Biomechanics

Analytical Solutions on the Flow of blood with the Effects of Hematocrit, Slip and TPMA in a porous tube

G. C. Hazarika 2 Department of Mathematics Dibrugarh University, Dibrugarh

STEADY VISCOUS FLOW THROUGH A VENTURI TUBE

World Journal of Engineering Research and Technology WJERT

*Corresponding Author: Surajit Dutta, Department of Mathematics, C N B College, Bokakhat, Golaghat, Assam, India

V (r,t) = i ˆ u( x, y,z,t) + ˆ j v( x, y,z,t) + k ˆ w( x, y, z,t)

Peristaltic transport of a newtonian fluid with wall properties in an asymmetric channel

Blood flow through arteries in a pathological state: A theoretical study

Mathematical modelling of blood flow through a tapered overlapping stenosed artery with variable viscosity

Exact Solution of an MHD Natural Convection Flow in Vertical Concentric Annulus with Heat Absorption

Peristaltic Transport of Micropolar Fluid in a Tubes Under Influence of Magnetic Field and Rotation A.M.Abd-Alla a, G.A.Yahya b,c, H.S.

Numerical Analysis of MHD Flow of Fluid with One Porous Bounding Wall

MHD FORCED FLOW OF A CONDUCTING VISCOUS FLUID THROUGH A POROUS MEDIUM INDUCED BY AN IMPERVIOUS ROTATING DISK

A new approach for local similarity solutions of an unsteady hydromagnetic free convective heat transfer flow along a permeable flat surface

Effect on the Flow of Bile Due to Radially Varying Viscosity in the Cystic Duct

Unsteady Hydromagnetic Couette Flow within a Porous Channel


Parash Moni Thakur. Gopal Ch. Hazarika

INFLUENCE OF HEAT TRANSFER ON PERISTALTIC FLOW OF JEFFREY FLUID THROUGH A POROUS MEDIUM IN AN INCLINED ASYMMETRIC CHANNEL

Numerical simulation of blood flow in a straight artery under the influence of magnetic field

Velocity Profiles of Unsteady Blood Flow through an Inclined Circular Tube with Magnetic Field

PREDICTION OF PULSATILE 3D FLOW IN ELASTIC TUBES USING STAR CCM+ CODE

Effects of Heat and Mass Transfer on Peristaltic Flow of Carreau Fluid in a Vertical Annulus

Numerical modelling of shear-thinning non-newtonian flows in compliant vessels

NUMERICAL SOLUTION OF MHD FLOW OVER A MOVING VERTICAL POROUS PLATE WITH HEAT AND MASS TRANSFER

CENG 501 Examination Problem: Estimation of Viscosity with a Falling - Cylinder Viscometer

Heat and Mass Transfer Effects of Peristaltic Transport of a Nano Fluid in Peripheral layer

Fluid Dynamics Exercises and questions for the course

Mathematical Model. M. Umar Qureshi, Mitchel J. Colebank, and Mette S. Olufsen

Effects of magnetic field and an endoscope on peristaltic motion

Radiation Effect on MHD Casson Fluid Flow over a Power-Law Stretching Sheet with Chemical Reaction

Analysis of Least Stable Mode of Buoyancy Assisted Mixed Convective Flow in Vertical Pipe Filled with Porous Medium

Some Aspects of Oscillatory Visco-elastic Flow Through Porous Medium in a Rotating Porous Channel

HALL EFFECTS ON UNSTEADY MHD OSCILLATORY FLOW OF BURGER S FLUID THROUGH A PIPE

Laplace Technique on Magnetohydrodynamic Radiating and Chemically Reacting Fluid over an Infinite Vertical Surface

Numerical Solution of Mass Transfer Effects on Unsteady Flow Past an Accelerated Vertical Porous Plate with Suction

Peristaltic Flow of A Couple Stress Fluids in an Inclined Channel

Transcription:

Theoretical Mathematics & Applications, vol. 6, no., 6, 99-3 IN: 79-9687 (print), 79-979 (online) cienpress Ltd, 6 Magnetic Effect on lip Flow of Blood through Porous Medium with Time Dependent Permeability, Pulsatile Pressure and Body Acceleration Lukendra Kakati, Dhruba Prasad Barua, Nazibuddin Ahmed 3 and Karabi Dutta Choudhury Abstract This paper investigates the flow of blood through a porous medium with time dependent permeability, in an inclined artery having mild stenosis, in the presence of pulsatile pressure gradient. The blood flow is assumed to possess Newtonian character and an azimuthal uniform magnetic field is imposed. The fluid flow takes place under body acceleration and we assume the existence of a slip velocity at the stenosed section of the arterial wall. Employing multi-parameter Department of Mathematics, Lanka Mahavidyalaya, Lanka, Nagaon-786, Assam, India. E-mail: lukendrakakati3@rediffmail.com Department of Mathematics, Gauhati University, Guwahati-78, Assam, India. E-mail: math_byte@yahoo.com 3 Department of Mathematics, Gauhati University, Guwahati-78, Assam, India. E-mail: saheel_nazib@yahoo.com Department of Mathematics, Assam University, ilchar- 788, Assam, India. E-mail: karabidc@gmail.com Article Info: Received: August 6, 5. Revised: October, 5. Published online : January 5, 6.

Magnetic Effect on lip Flow of Blood through Porous Medium perturbation procedure, solutions are obtained for the flow field and wall shear stress and their behaviors are analyzed under the influence of various relevant parameters concerning the magnetic field, slip velocity, porosity, inclination, pulsatile pressure and the periodic body acceleration. The results are displayed pictorially and construed. The results reveal that the azimuthal magnetic field, slip velocity, inclination, pulsatile pressure, periodic body acceleration and the time-dependent permeability of the porous medium play significant roles on the velocity field, and the wall shear stress. The imposition of the magnetic field causes a decline in the axial velocity of blood and the wall shear stress. Further, a growth in the porosity of the medium causes a rise in the axial blood velocity as well as the wall shear stress. Mathematics ubject Classification: 76Z5; 7G; 76W5 Keywords: MHD; Pulsatile; time dependent Permeability; lip velocity; Blood flow; tenosis; Inclined Introduction The studies related to blood flow through stenosed arteries have garnered wide interest in the field of Bio-Medical research. tenosis or atherosclerosis may be defined as the formation of some constriction in the inner arterial wall owing to the deposition of lipoproteins and fatty acids (atherosclerotic plaques) in the lumen of the artery. uch constrictions lead to considerable change in the flow of blood, the pressure distribution and the wall shear stress, thereby impeding the normal circulatory processes and consequently leading to cardiovascular diseases. Even for mild atherosclerosis, the velocity gradient in the stenosed wall is steep owing to the increased core velocity. This results in comparatively large shear stress on the arterial wall. Mathematical models of blood flow through arteries

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. under diverse physiological situations were presented by several authors like Fung [], McDonald [], Zamir [3] and David et al. []. Theoretical and experimental investigations concerning flow of blood through stenosed arteries were presented by Young [5], Liu et al. [6], Yao and Li [7] and Mekheimer and El-Kot [8]. The human body may be subjected to body accelerations (vibrations) under certain situations such as riding a heavy vehicle or flying in a helicopter. This may cause health problems like vascular disorders and increased pulse rate. tudies related to blood flow under the influence of body acceleration were carried out by several research workers such as ud and ekhon [9] and El-hahed []. The Pulsatile nature of blood flow in arteries may be attributed to the heart pulse pressure gradient. tudies in pulsatile blood flow were carried out by researchers like [] and Elshehawey et al. []. The possibility of velocity slip at the blood vessel wall was investigated theoretically by Brunn [] and Jones [3] and experimentally by Bennet [] and Bugliarello and Hayden [5]. The methods to detect and determine slip experimentally at the blood vessel wall have been indicated by Astarita et al. [6] and Cheng [7] respectively. It was first Kolin [8] and later Korchevskii and Marochnik [9] who suggested the scope of electromagnetic fields in Bio-Medical studies. Barnothy [] indicated that for biological systems, the heart rate decreases under the influence of an external magnetic field. In certain pathological circumstances, the distribution of fatty cholesterol and artery-clogging blood clots in the lumen of the coronary artery may be regarded as equivalent to a fictitious porous medium. Xu et al. [] assumed the blood clot as a porous medium to investigate the transport characteristics of blood flow in the extension of multi-scale model by incorporating a detailed sub model of surface-mediated control of blood coagulation (Xu et al. [, 3]). In general, blood is a non-newtonian fluid. However, it has been established that human blood exhibits Newtonian behavior at all rates of shear for hematocrits up to about % []. Further, in case of relatively larger blood vessels it is sensible to assume that blood has a constant viscosity, since the diameters of such vessels are large

Magnetic Effect on lip Flow of Blood through Porous Medium compared with the individual cell diameters and because shear rates are quite high for viscosity to be independent of them. Consequently, for such vessels the non-newtonian character becomes unimportant and blood may be regarded as a Newtonian fluid. In view of the aforementioned facts, we may cite the works done by Elshehawey et al. [], Nagarani and arojamma [5], hehawey and EL ebaei [6], Tzirtzilakis [7], and Ahmed et al. [9]. The aim of the present study is to investigate theoretically the nature of a pulsatile blood flow through a mildly stenosed artery under the combined influence of an azimuthal uniform magnetic field, slip velocity, body acceleration and time dependent permeability, when the artery is inclined to the vertical. The investigation is carried out by treating blood flow as Newtonian. The solutions have been obtained in terms of Bessel function, using multi-parameter perturbation technique. The formulation of the Problem For this problem, we take an axially symmetric, laminar, one-dimensional and fully developed blood flow through an inclined and catheterized circular artery, in the presence of a time-dependent pressure gradient, body acceleration and an azimuthally applied magnetic field of low strength. o the induced magnetic field is negligible. We suppose that the boundary wall of the artery is rigid and the artery has a porous medium of time dependent permeability. Next, the artery is inclined to the vertical and a slip velocity is considered at the stenosed region of the arterial wall. Here, blood is considered as a Newtonian fluid and thus the flow is assumed to be Newtonian. The flow configuration is shown diagrammatically, at the end of the Result and discussion section. The geometry of an arterial stenosis is (Nagarani and arojamma [5]), as below:

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. 3 ( ) R z ds z L + cos, for z d d L, for z > d = Where R( z ) is the radius of the artery in the stenosed region, L is the constant arterial radius in the non-stenosed region, d is the half-length of the stenosis and d s is the greatest height of the stenosis such that d s L () is less than unity for a mild stenosis. Here the radial velocity is very small due to the low Reynolds number flow through the artery with mild stenosis (Nagarani and arojamma [5]); hence we do not consider the radial velocity. From Navier-tokes equations of motion, the momentum equation governing the flow is reduced in the cylindrical coordinate system ( r,, z) θ as under: u P u u σ ub υu = F( t) + gcos β + υ + t ρ ρ z r r r ρ K P = gρinβ r () (3) Where u denotes the velocity along the z - axis, P the pressure, ρ the density, t the time, F( t ) the body acceleration, B the applied magnetic field in azimuthal ( θ ) direction, υ the kinematic viscosity, σ the electrical conductivity, g the acceleration due to gravity, β the angle of inclination of the artery with the vertical and K the periodic permeability of the porous medium, such that permeability. The relevant boundary conditions are: K K =, where ε k is the amplitude of + ε cos k ( ωpt)

Magnetic Effect on lip Flow of Blood through Porous Medium ( ) u= V at r= R z () s u = at r = r (5) Where V s is the slip velocity at the stenosed region of the arterial wall. When t >, a periodic body acceleration F( t ) is levied on the flow and this is expressed as under (Nagarani and arojamma [5]): ( ) cos ( ω θ ) F t = f t+ (6) Where ω = Fb, f is the amplitude of the body acceleration and F b is the frequency (in Hertz) of body acceleration. Also, θ is the lead angle with respect to the heart action. F b is assume as very small so that the wave effect can be neglected (Nagarani and arojamma [5]). Now, for t, the pressure gradient is considered as: (, ) Pzt = P z + P z t z ( ) ( ) cos( ω P ) Where, P ( z) and ( ) P z are the steady state pressure gradient and the amplitude of the oscillatory part of the pressure gradient. Further, ωp = f where f P is the pulse rate frequency. We define the following non-dimensional substitutions: ( ) ω z R z r ds υρu z =, R( z) =, r =, t = tωp, ω =, ds =, u =, L L L ω P L PL g υρvs L P P f, s, τ, ε, ε,, PL PL υ ρ τ ω B = V = = = = B= P P P σ B L K d µ E µ E M =, K =, d =, =, υρ L L 8 υρ Where ε, M, K and d s are respectively the Pulsatile Reynolds number or the P (7) (8)

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. 5 Womersley frequency parameter, Hartmann number or magnetic parameter, the permeability parameter and the dimensionless height of the stenosis. The remaining quantities relevant to this problem are described at their appropriate places. We use the substitutions of (8) into (), (), (), (5), (6) and (7) and then simplifying, we get the corresponding non-dimensional forms. Non-dimensional form of the geometry of arterial stenosis: ( ) R z d z + cos, for z d s = d, for z > d Non-dimensional momentum equation: u ε = cos ω + θ + cos β + + ε cos t { B ( t ) B ( t) } u + ε k cost + r M + u r r r K The non-dimensional boundary conditions: (9) () u= V at r= R () s u = at r = r () 3 Method of olution for flow field We have solved the problem with the aid of multi-parameter perturbation technique. For perturbation technique, let the Pulsatile Reynolds number ε to be extremely small, as a consequence the velocity u may be represented by the following series: ( ) ( ) ε ( ) u zrt,, = v zrt,, + v zrt,, +... (3) Putting (3) in (), using the boundary condition () and () and equating the

6 Magnetic Effect on lip Flow of Blood through Porous Medium similar coefficients of ε and then neglecting the terms having higher powers of ε, we get: v + ε k cost = ht ( ) + r M+ v r r r K v v + ε k cost = r M + v t r r r K where ht ( ) Bcos( ωt θ) B cos β ( ε cost) = + + + +. () (5) Taking v = v + ε v k k ε k as perturbation parameter, we assume: v = v + ε v (7) Putting (6) and (7) in (), (5) and equating the coefficients of and then neglecting the terms containing higher powers of ε k, we get ε k and (6) ε k v = ht ( ) + r M+ v r r r K v cost = r v + M + v r r r K K v v = r M + v t r r r K (8) (9) () v v cos t = r v + M + v t r r r K K () The subsequent boundary conditions are: v = V, v =, v =, v = at r= R () s v v v v =, =, =, = atr = (3) r r r r The solution of the equations (8), (9), () and () with respect to the boundary conditions (), (3) are as follows:

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. 7 ( ) ( ) v = c J ri K + h t K v, where c V s ht ( ) K =, J Ri K ( ) = V ( r) h ( t), where h ( t) represents the derivative of ( ) r V( r) = cj( ri K) + ψ ( r) + c where, ψ c ( r) ( ) ( ) = + K J ri K K ri K J ri K r K R = ψ ( R), K c J Ri K ( ) ( ) V r v = costh( t), K ;, ( ) 3 ( ) ( ) v = J ri K z( r) + cost h t h t sin t KK where K = M +, K ( ), htwith respect to t ; cr ccr cr cc c z() r = + + + ψ 3 K K K K KK and ( r) c ci K ci K ( ψ ( r) ) ψ( r) ψ3( r) B K KK KK + + + +, cr cc R cr cc c B = 3 + K K J( Ri K) 3 K K K K KK c ci K ci K ( ψ ( R) ) ψ( R) ψ3( R) K KK KK, ψ ( R)

8 Magnetic Effect on lip Flow of Blood through Porous Medium r i ( ) ( ) r i K ( ) ( ( )) ψ r = Log J r i K x Log J xi K dx, K K ( ) ( ) K ( ( ) ) ir J ri K ir 3( r) Log J r i K ψ = K J ri K r i + x Log J xi K dx K ( ( )) Consequently, the non-dimensional axial velocity u( zrt,, ) is given by: ( ) = + ε + ε ( + ε ) u zrt,, v kv v kv Actually the expressions for z() r and B can assume much simpler forms. But we have expressed them as above in order to illustrate the interesting functions namely ψ ( r) and ψ 3 ( r) calculations., that we encountered during the course of our. Non-dimensional Wall hear tress Assuming a rigid arterial wall, the dimensionless wall shear stress τ at r= R is as under: τ τ =, PL where u τ = υρ r r = R is the dimensional wall shear stress at r= R. Consequently, we get: u v v v v τ= = + ε + ε + εε r r r r r v r k k r= R r = R where = c i K J ( ri K ) h( t),,

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. 9 v, r and = h ( tv ) ( r) c where V ( r) = cci K J( ri K) + rj( ri K) v r Again, = costh( t) v r. V ( r) K and ( ) ( ) where z ; ( th t h t t) z r J( ri K) z r i K J( ri K) = cos sin () (), ( ) ( ) rj ri K ccr cc c () r = +. K K KK J ri K 5 Non-dimensional Volumetric Flow Rate follows: (, ) Q zt The non-dimensional volumetric flow rate Q( zt, ) may be defined as 8 υρ Q( zt, ) =, where (, ) L P R Q z, t = r u z, r, t dr. and is given by ( ) ( ) Consequently, R Q zt is the dimensional volumetric flow rate (, ) = (,, ) = ( + εk + ε + ε εk ) Q z t r u z r t dr Q Q Q Q, where we define the following: ( ) ( ) ( ) R = = c h t Ri K J Ri K + htr K K Q r v dr ;

Magnetic Effect on lip Flow of Blood through Porous Medium ( ) R V( R) ( ) R costh t c R J Ri K Q = r v dr = c K K + ( ) 3 c R i K J Ri K K ( ) ( ) ; R RV R c R J Ri K Q = r v dr h ( t) = c K + ( ) 3 c R i K J Ri K K ; ( ) R z( R) Ri K J Ri K Q = r v dr ( cost h ( t) h( t) sin t) = K ( ) i K ψ R R, + + 3 K KK where, ψ ( ) ( ) ( ) K K ( ) c R i J Ri K c R i J Ri K R = c + c K K K K J Ri K. 6 Dimensionless Effective Viscosity The effective viscosity µ E in dimensional form may be defined as under, following Pennington and Cowin [8]: Pzt µ = E (, ) ( R( z) ) z Qzt (, ) µ = E ( + ε cos ) Q( zt, ) t R

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. where µ E is the non-dimensional effective viscosity. 7 Result and discussion In order to get an insight into the biological and physical aspects of this problem, we obtain the profiles of the axial velocity, wall shear stress, volumetric flow rate and the effective viscosity, and we examine their behaviors under the influence of the various non-dimensional parameters relevant to this problem. The data-tabulation involved in this problem is carried out with the aid of Wolfram Mathematica. Unless otherwise indicated, for the data-tabulation, we take ε =, z =., d =.3, ε =.,. R =.9375, t = 3,.5, B.5. k ε = = Clearly, [,R] θ =, B =.5, ω =, d s =.5, 3 8 r and using (9) and then noting that z < d for the aforementioned choice of z, d, we find that R =.9375. Thus, for our choice of, z d, r [,.9375]. It may be mentioned that the values of t (involved in the following Figures 5 to 5, and then from the Figures 7 to 9 and in the Table ) range from to. This is done to incorporate one complete period (full cycle) of the pulsatile pressure gradient and the periodic body acceleration.

Magnetic Effect on lip Flow of Blood through Porous Medium.5..35 M = u.3.5..5. M = 5 M = 3.5 r..3.5.7.9375 Figure : Velocity u against r, under the effect of M for K =, β =, V. =.5.5..35 u.3.5. K =.5 K = K = 5.5..5..3.5.7.9375 r Figure : Velocity u against r, under the effect of K for M =, β =, V. =

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. 3.6 u.5..3. β = β = 6. β = 8 r..3.5.7.9375 Figure 3: Velocity u against r, under the effect of β for M =, K =, V =..5..35 u.3.5..5 V =. V =. V =.7..5 r..3.5.7.9375 Figure : Velocity u against r, under the effect of V for M =, K =, β = From the above Figures to, it is evident that the blood flow speed increases as the porosity and the slip velocity rises. Thus, the possible imposition

Magnetic Effect on lip Flow of Blood through Porous Medium of slip velocity at the stenosed wall and greater porosity may enhance the blood flow through the stenosed section of the artery. These observations agree with well known results and this validates our flow model as physically realizable. Again, it is seen that the blood flow speed decreases with the imposition of the magnetic field and an increase in the angle of inclination. The application of the azimuthal magnetic field leads to the development of Lorentz force that in turn decelerates the flow. Hence, the azimuthal magnetic field can be used to control the blood flow through stenosed artery. Moreover, it is obvious from the Flow configuration figure that a rise in β (inclination) would imply lesser assistance from gravity towards the blood flow that is occurring in the downward direction along the z-axis. Naturally then, a rise in β (inclination) will cause a reduction in the blood flow speed. The Figures 5, 6 and 7 and the Table respectively show the behavior of wall shear stress under the influence of magnetic field, porosity, inclination and the slip velocity. It is observed from Figure 6 that a rise in the porosity of the medium leads to an increase in the wall shear stress at the stenosed section of the arterial wall. This may be attributed to the fact that the blood flow speed registers a rise as the porosity increases. Consequently, the shear stress also increases. Again, it is inferred from the Figures 5, 7 and Table respectively that the wall shear stress at the stenosed section exhibits a decrease with the increase in each of magnetic field, inclination and slip velocity. We may recall that the blood flow speed registers a fall with the imposition of the azimuthal magnetic field and an increase in the inclination angle. ubsequently, the wall shear stress decreases too. Moreover, it is seen from Figures 5, 6 and 7 and Table that the wall shear stress first decreases and then again increases against dimensionless time t. This is due to the periodic nature of the pulsatile pressure gradient associated with this blood flow model.

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. 5.8.6. M =. τ.8.6.. M = 7 M = 3 t.89.78.67 3.56.5 5.3 6.3 Figure 5: hear stress τ against t under the effect of M, for K =, β =, V =..8.6. K = 5. K =.5 τ.8 K =.6...89.78.67 3.56.5 5.3 6.3 t Figure 6: hear stress τ against t under the effect of K, for M =, β =, V =.

6 Magnetic Effect on lip Flow of Blood through Porous Medium.8.6. β = 6 τ..8.6 β =...89.78.67 3.56.5 5.3 6.3 t β = 8 Figure 7: hear stress τ against t under the effect of β, for M =, K =, V =. Table : hear stress τ against t under the effect of M =, K =, β =. V, for t τ ( V =.) τ ( V = ) τ ( V =.7).66.59376.583.386.33639.37 7.9596.89375.8839 7 6.56.55537.9863 7 8.5.3935.37955 7.5838.579.5677 7.878957.86667.85337 7.563.97.93

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. 7.. Q.8.6 M = M =3. M =7..89.78.67 3.56.5 5.3 6.3 t Figure 8: Volumetric flux Q against t under the effect of M, for K =, β =, V =..5 M = 7.5 µ E.5 M = M = 3.89.78.67 3.56.5 5.3 6.3 t Figure 9: Effective viscosity µ E against t under the effect of M, for K =, β =, V =.

8 Magnetic Effect on lip Flow of Blood through Porous Medium.6. K = 9. Q.8 K = 5.6 K =...89.78.67 3.56.5 5.3 6.3 t Figure : Volumetric flux Q against t under the effect of K, for M =, β =, V =..6.. K = 9 K = 5 µ E.8 K =.6.. t.89.78.67 3.56.5 5.3 6.3 Figure : Effective viscosity µ E against t under the effect of K, for M =, β =, V =.

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. 9.6.. β = 6 β = Q.8.6. β =..89.78.67 3.56.5 5.3 6.3 t Figure : Volumetric flux Q against t under the effect of β, for M =, K =, V =. 3.5 β =.5 µ E.5 β = 6.89.78.67 3.56.5 5.3 6.3 t β = Figure 3: Effective viscosity µ E against t under the effect of β, for M =, K =, V =.

Magnetic Effect on lip Flow of Blood through Porous Medium.6.. V =.9 Q.8 V =..6.. V =..89.78.67 3.56.5 5.3 6.3 t Figure : Volumetric flux Q against t under the effect of M =, K =, β = V, for.6.. µ E.8 V =. V =.9.6. V =...89.78.67 3.56.5 5.3 6.3 t Figure 5: Effective viscosity µ E against t under the effect of V, for M =, K =, β =

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. The above Figures 8 to 5 portray how the dimensionless volumetric flux Q and the non-dimensional effective viscosity µ E are affected by the magnetic field (M), porosity (K), inclination ( β ) and the velocity slip ( V ). From these figures, it is observed that the imposition of the azimuthal magnetic field or an increase in the inclination β decreases the volumetric flux but increases the effective viscosity. On the other hand, a growth in the porosity or the slip velocity leads to a rise in the volumetric flux but causes the effective viscosity to decrease. The perturbed nature of the profiles for the effective viscosity and the volumetric flux against t may be attributed to the pulsatile nature of blood flow owing to the presence of a time dependent pressure gradient. For the following Figures 6 to 9, unless otherwise indicated, we assume that z =., d =.3, ε =., ε =., θ =, ω =, d s =.5, R =.9375, t = 3, ε =.5. 3 8 k.7.6 B =., B =.5.5 B =.8, B =.5 u..3 B =.5, B =.5.. B =.5, B =. B =.5, B =...3.5.7.9375 Figure 6: Velocity u versus r, under BB, for K =, β =, V =., M =, t = 3 r

Magnetic Effect on lip Flow of Blood through Porous Medium.6. B =, B=.5. B =.5, B=.9 Q.8.6 B =., B=.5.. B =.5, B= B =.5, B=.5.89.78.67 3.56.5 5.3 6.3 Figure 7: Volumetric flux Q versus t, under BB, for K =, β =, V =., M = t The Figures 6 to 9 exhibit the influence of the parameters B and B on the axial velocity u, the volumetric flux Q, the effective viscosity µ E and the shear stress τ respectively. It may be noted from the non-dimensional substitutions that B denotes the relative effect of body acceleration over the steady state pressure force. Further, B signifies the relative effect of gravitational body force (per unit volume of blood) over the steady state pressure force. We observe from Figure 6 that the axial velocity u decreases as B increases, whereas u exhibits a growth when B rises. From Figure 7 we note that the volumetric flux Q increases for small time t and decreases for large time t as B rises. The same figure indicates a growth in Q as B increases for all time t.

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. 3 3.5 3 B=, B =.5 B=.5, B =.5.5 µ E.5 B=.5, B =..5 B=.5, B = B=.8, B =.5.89.78.67 3.56.5 5.3 6.3 t Figure 8: Effective viscosity µ E versus t, under BB, for K =, β =, V =., M = Figure 8 shows that a rise in B leads to a fall in effective viscosity µ E for small time t, but µ E increases for large values of t. The same figure also depicts a decay in µ E as B registers a growth for all values of time t. Figure 9 portrays decay in shear stress τ for large time t and a growth in τ for small timet as B increases. However, τ registers a growth for all time t, as B increases.

Magnetic Effect on lip Flow of Blood through Porous Medium.8.6 B =, B=.5. τ..8 B =.5, B=.5.6. B =.5, B=.5 B =.5, B=. t B =.5, B=.5.89.78.67 3.56.5 5.3 6.3 Figure 9: hear stress τ versus t, under BB, for K =, β =, V =., M = r g β R( z ) B d d s V s z L Flow configuration: chematic figure of an inclined stenosed artery with azimuthal magnetic field

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. 5 8 Conclusions In order to elucidate the significance of our flow model and in view of the results obtained, we may conclude the following points:. The imposition of the magnetic field causes a decrease in each of axial velocity of blood and the wall shear stress at the stenosed section. This shows that the applied azimuthal magnetic has considerable scope in the field of treating cardiovascular diseases resulting from stenosis. The use of an azimuthal magnetic field can aid in effectively controlling the blood velocity and minimizing the large shear stress on the stenosed arterial wall.. The application of the slip velocity at the stenosed section leads to a growth in the axial velocity of blood. Thus, the blood flow rate in the stenosed section may be enhanced by the imposition of slip velocity. But, the wall shear stress decreases with the imposition of the slip velocity. Hence, slip inducing medical drugs may be beneficial in effectively controlling the wall shear stress in a stenosed artery. 3. As the angle of inclination increases, the blood velocity and the wall shear stress decreases.. A growth in the permeability of the medium causes each of axial blood velocity and the wall shear stress to increase. In certain pathological conditions, the distribution of fatty cholesterol and artery-clogging blood clots in the lumen of the coronary artery may be represented by a fictitious porous medium. Therefore, an augmentation in the permeability of such porous media can enhance the blood flow rate in a stenosed artery. This may be achieved through the development of proper medical procedures and by developing medical drugs that enhance the permeability in a stenosed / clogged artery.

6 Magnetic Effect on lip Flow of Blood through Porous Medium 5. It is clear that the blood flow rate in stenosed arteries may be enhanced by imposing velocity slip at the stenosed regions and by increasing the porosity in the arteries. Thus, medical drugs that induce velocity slip at the stenosed walls and drugs that enhance the porosity in the arteries are efficient in the treatment of heart diseases induced by arterial stenosis. 6. The azimuthal magnetic field may prove to be effective in regulating the volumetric flow rate of blood in stenosed arteries. 7. An augmentation in the ratio of amplitude of body acceleration to the mean pressure causes decay in the axial velocity. However, the axial velocity registers a growth as the ratio of gravitational body force to the steady state pressure increases. 8. A rise in the ratio of amplitude of body acceleration to the mean pressure leads to a growth in the volumetric flux for small values of time and causes a fall in the volumetric flux for larger values of time. This takes place within one full time cycle from to. Thus, the above behavior is attributable to the periodic natures of the body acceleration and the pulsatile pressure gradient. 9. Within one full time cycle from to, an increase in the ratio of gravitational body force to the steady state pressure causes the volumetric flux rate to rise.. Within one full time cycle from to, a rise in the ratio of amplitude of body acceleration to the mean pressure leads to a fall in the effective viscosity for small time and causes the effective viscosity to increase for large time. Clearly, it is a consequence of the periodic natures of the body acceleration and the pulsatile pressure gradient.. The effective viscosity registers a fall as the ratio of gravitational body force to the steady state pressure increases.

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. 7. For one complete time cycle from to, the shear stress increases for small time and then again decreases for large time, as the ratio of amplitude of body acceleration to the mean pressure increases. Evidently, this effect is brought about by the periodic natures of the body acceleration and the pulsatile pressure gradient. 3. The shear stress exhibits a growth as the ratio of gravitational body force to the steady state pressure rises. This also indicates that an increase in the density of blood may lead to a rise in the arterial wall shear stress.. It follows from the preceding conclusion that the arterial wall shear stress (i.e. the so called high blood pressure ) may be minimized (i.e. effectively controlled) by lowering the density of blood in the body. This calls for the development of suitable medical procedures and drugs to achieve the same. Acknowledgements. The authors are highly thankful to CIR-HRDG for funding this research work under Research Grant-in-aid No. 5(9)//EMR-II. References [] Y. C. Fung, Biodynamics Circulation, pringer-verlag, New York, 98. [] D. A. McDonald, Blood Flow in Arteries, Arnold, London, 96. [3] M. Zamir, The Physics of Coronary Blood Flow, pringer, New York, 5. [] M.W. David, P.M. Christos, R.H. tephen and N. Ku. David, A mechanistic model of acute platelet accumulation in thrombogenic stenoses, Annals of Biomedical Engineering, 9(), (), 3-39. [5] D.F. Young, Fluid Mechanics of Arterial tenoses, Journal of Biomechanical Engineering,, (979), 57-75.

8 Magnetic Effect on lip Flow of Blood through Porous Medium [6] Z.R. Liu, G. Xu, Y. Chen, Z.Z. Teng and K.R. Qin, An Analysis Model of Pulsatile Blood Flow in Arteries, Applied Mathematics and Mechanics,, (3), 3-. [7] L. Yao and D.Z. Li, Pressure and Pressure Gradient in an Axisymmetric Rigid Vessel with tenosis, Applied Mathematics and Mechanics, 7, (6), 37-35. [8] Kh.. Mekheimer and M. A. El Kot, Influence of Magnetic Field and Hall Currents on Blood Flow through a tenotic Artery, Applied Mathematics and Mechanics, 9, (8), 93-. [9] V.K. ud and G.. ekhon, Blood flow subject to a single cycle of body acceleration, Bulletin of Mathematical Biology, 6, (98), 937-99. [] M. El-hahed, Pulsatile flow of blood through a stenosed porous medium under periodic body acceleration, Appl. Math. Comput., 38, (3), 79-88. [] E.F. Elshehawey, E.M.E. Elbarbary, M.E. Elsayed, N.A.. Afifi and M. El-hahed, Pulsatile flow of blood through a porous medium under periodic body acceleration, Int. J. Theoretical Phys., vol. 39 (), (), 83-88. [] P. Brunn, The Velocity lip of Polar Fluids, Rheol. Acta.,, (975), 39-5. [3] A.L. Jones, On the Flow of Blood in a Tube, Biorheology, 3, (966), 83-88. [] L. Bennet, Red Cell lip at a Wall, in vitro. cience, 55, (967), 55-556. [5] G. Bugliarello and J.W. Hayden, High peed Micro Cinematographic tudies of Blood Flow, in vitro. cience, 38, (96), 98-983. [6] G. Astarita and G. Marrucci, Principles of Non-Newtonian Fluid Mechanics, McGraw-Hill, New York, UA, 97. [7] D.C.H. Cheng, The Determination of Wall lip Velocity in the Laminar Gravity Flow of Non-Newtonian Fluids along Plane urfaces, Ind. Eng. Chem. Fundamen., 3, (97), 39-395.

Lukendra K., Dhruba P.B., Nazibuddin A.and Karabi D.C. 9 [8] A. Kolin, An Electromagnetic Flowmeter: Principle of Method and Its Application to Blood Flow Acceleration, Experimental Biology and Medicine, 35, (936), 53-56. [9] E.M. Korchevskii and L.. Marochnik, Magneto Hydrodynamic Version of Movement of Blood, Biophysics,, (965), -3. [] M.F. Barnothy, Biological Effects of Magnetic Fields, Plenum Press, New York, 96. [] Z.L. Xu, J. Mu, J. Liu, M.M. Kamocka, X. Liu, D.Z. Chen, E.D. Rosen and M.. Alber, Multiscale model of venous thrombus formation with surface-mediated control of blood coagulation cascade, Biophysical Journal, 98, (), 73-73. [] Z.L. Xu, N. Chen, M.M. Kamocka, E.D. Rosen and M.. Alber, Multiscale Model of Thrombus Development, Journal of the Royal ociety Interface, (), (8), 75-73. [3] Z.L. Xu, N. Chen,. hadden, J.E. Marsden, M.M. Kamocka, E.D. Rosen and M.. Alber, tudy of blood flow impact on growth of thrombi using a multiscale model, oft Matter, 5, (9), 769-779. [] J.T. Ottesen, M.. Olufsen and J.K. Larsen, Applied Mathematical Models in Human Physiology, IAM monographs on mathematical modeling and computation, (). [5] P. Nagarani and G. arojamma, Effect of body acceleration on pulsatile flow of Casson fluid through a mild stenosed artery, Korea-Australia Rheology Journal,, (8), 89-96. [6] E.F. EL hehawey and W.E.L. ebaei, Peristaltic transport in a cylindrical tube through a porous medium, International Journal of Mathematics and Mathematical ciences,, (), 7-3. [7] E.E. Tzirtzilakis, A Mathematical Model for Blood Flow in Magnetic Field, Physics of Fluids, 7, (5), -5.

3 Magnetic Effect on lip Flow of Blood through Porous Medium [8] C.J. Pennington and.c. Cowin, The Effective Viscosity of Polar Fluids, Trans. oc. Rheol.,, (97), 9-38. [9] N. Ahmed, D.P. Barua and D.J. Bhattacharyya, MHD Pulsatile lip Flow Of Blood Through Porous Medium In An Inclined tenosed Artery In Presence Of Body Acceleration, Journal of Applied Mathematics and Bioinformatics, (3), (), -8.