Ion-mobility mass spectrometry of polyoxometalate Keplerate clusters and their supramolecular assemblies

Similar documents
The precursor (TBA) 3 [H 3 V 10 O 28 ] was synthesised according to the literature procedure. 1 (TBA = n tetrabutylammonium).

- Supporting Information -

Multi-stage Mass Spectrometry up to MS 4 on a QTof System

Supporting Information

Identification of Human Hemoglobin Protein Variants Using Electrospray Ionization-Electron Transfer Dissociation Mass Spectrometry

Estimating Collision Cross Sections from Travelling Wave IM-MS Data: How it is done and what are the Problems?

TANDEM MASS SPECTROSCOPY

Supporting Information

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

Improved Ion Mobility Separation of Protein Conformations in the Gas Phase with SYNAPT G2 HDMS

Mass Spectrometry in MCAL

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Ion Mobility Mass Spectrometry of Complex Carbohydrates Collision Cross Sections of Sodiated N- linked Glycans. - Supporting Information -

Zwitterionic i-motif structures are preserved in DNA negatively charged ions. produced by electrospray mass spectrometry

SUPPORTING INFORMATION

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Star-like supramolecular polymers fabricated by a Keplerate cluster. with cationic terminated polymers and their self-assembly into.

[ instrument specifications ]

INTRODUCTION OVERVIEW

Fereshteh Zandkarimi, Samanthi Wickramasekara, Jeff Morre, Jan F. Stevens and Claudia S. Maier

Electron Transfer Dissociation of N-linked Glycopeptides from a Recombinant mab Using SYNAPT G2-S HDMS

Supporting Information Exploring the Programmable Assembly of a Polyoxometalate-Organic Hybrid via Metal Ion Coordination

Supporting Information

M M e M M H M M H. Ion Sources

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Patrick F. James, Matthew A. Perugini and Richard A.J. O Hair

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Chapter 5. Complexation of Tholins by 18-crown-6:

Technical Note. Introduction

Types of Analyzers: Quadrupole: mass filter -part1

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

Analysis of Multiply Charged Poly(ethylene oxide-co-propylene oxide) Using Electrospray Ionization Ion Mobility Spectrometry Mass Spectrometry

Chapter 1. Introduction

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Supplemental Information. Nano-sized I 12 L 6 Molecular Capsules. Based on the [N,,,I +,,,N] Halogen Bond

CN)] + P) 2. Ag 2 CH)] [dppm [dppmag [dppbzag [dppe 2

Supporting Information for the paper: Structure-Reactivity Correlations in Metal Atom Substitutions of Monolayer- Protected Noble Metal Alloy Clusters

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

IDENTIFICATION OF ORGANOMETALLIC COMPOUNDS USING FIELD DESORPTION IONIZATION ON THE GCT

Supplementary Information

CHAPTER-2 Formation of Adenine from CH 3 COONH 4 /NH 4 HCO 3 the Probable Prebiotic Route for Adenine

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Rapid Distinction of Leucine and Isoleucine in Monoclonal Antibodies Using Nanoflow. LCMS n. Discovery Attribute Sciences

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Electron capture dissociation of extremely supercharged protein. ions formed by electrospray ionisation

Chemistry Instrumental Analysis Lecture 37. Chem 4631

4.1 MATERIALS 4.2 EQUIPMENTS

SUPPLEMENTARY INFORMATION

Supporting Information. Nitroxide Mediated Polymerization of methacrylates at moderate temperature

Gas-Phase DNA Helix Conformations

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

L.7. Mass Spectrum Interpretation

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Supplementary Information

Determination of urea in ultrapure water by IC-MS/MS

Efficient Magnesium Catalysts for the Copolymerization of Epoxides and CO 2 ; Using Water to Synthesize Polycarbonate Polyols

The Aerosol Ion Trap Mass Spectrometer (AIMS): Instrument development and first experimental results

APPLICATION SOLUTIONS FOR STRUCTURAL PROTEOMICS

Stabilization of a Reactive Polynuclear Silver Carbide Cluster through the Encapsulation within Supramolecular Cage

CHROMATOGRAPHY AND MASS SPECTROMETER

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Introduction to the Q Trap LC/MS/MS System

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Dry Deposition of Biogenic Terpenes via Cationic. Oligomerization on Environmental Aqueous Surfaces

1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).

Thermo Finnigan LTQ. Specifications

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Electrospray Ion Trap Mass Spectrometry. Introduction

Measurements of isoprene-derived organosulfates in ambient aerosols by aerosol time-offlight

Yujuan Zhou, Kecheng Jie and Feihe Huang*

Conc n of A OAs present (um) Conc n of B OAs present (um)

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

Solutionchemistry is often initiated or enhanced by

MALDI-HDMS E : A Novel Data Independent Acquisition Method for the Enhanced Analysis of 2D-Gel Tryptic Peptide Digests

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Disulfide Linkage Characterization of Disulfide Bond-Containing Proteins and Peptides by Reducing Electrochemistry and Mass Spectrometry

CONTRIBUTION OF ION MOBILITY FOR STRUCTURAL ANALYSIS AND ANALYTICAL CHEMISTRY: THE USE OF PROBE LIGANDS AND SELECTIVE IMS SHIFT REAGENTS

Formation of Light Absorbing Soluble Secondary Organics and. Insoluble Polymeric Particles from the Dark Reaction of Catechol and

A Novel Detection Technique of Hydrazine Hydrate: Modality Change of Hydrogen-Bonding Induced Rapid and Ultrasensitive Colorimetric Assay

Mechanistic Insights into Chloride Ion Detection from the Atmospheric-Pressure Afterglow of an Argon Inductively Coupled Plasma

2017 Reaction of cinnamic acid chloride with ammonia to cinnamic acid amide

Supporting Information. Labeled Ligand Displacement: Extending NMR-based Screening of Protein Targets

Paolo Tosi Dipartimento di Fisica - Università di Trento

Finnigan LCQ Advantage MAX

Analysis of Labeled and Non-Labeled Proteomic Data Using Progenesis QI for Proteomics

Supporting information Gas-phase conformations of capistruin comparison of lasso, branched-cyclic and linear topologies

Transcription:

SUPPLEMENTARY INFORMATION Table of Contents Summary 1. General materials and methods 2. High-resolution mass spectra 3. Ion-mobility mass spectra 4. Fragmentation of clusters in the TWIMS drift tube 5. Fragmentation of clusters of clusters to yield intact clusters References Ion-mobility mass spectrometry of polyoxometalate Keplerate clusters and their supramolecular assemblies Philip J. Robbins, Andrew J. Surman, Johannes Thiel, Deliang Long, Leroy Cronin* Email: Lee.Cronin@glasgow.ac.uk ; website: http://www.croninlab.com WestCHEM, School of Chemistry, University of Glasgow, Glasgow, G12 8QQ, UK *To whom correspondence should be addressed. S1

1. General Materials and Methods 1.1 Analyte preparation Compounds 1 1, 2 2 and 3 3 were synthesized according to literature procedures. The precursor of compound 4 was synthesized according to literature procedure 4 and compound 4 was precipitated from aqueous solution with tetra(n-butyl)ammonium chloride. 1.2 Mass Spectrometry Sample Preparation Negative mode high-resolution and ion-mobility mass-spectrometry measurements were performed on a Synapt G2 HDMS from Waters. For compounds 1, 2 and 3, aqueous solutions with a concentration of 10-3 M were diluted with acetonitrile by a factor of one hundred. Compound 4 was directly dissolved in acetonitrile at a concentration of 10-5 M. The analyte solutions were filtered through a syringe filter (0.2 µm) before injected into the spectrometer via a syringe pump at a flow rate of 5 µl min -1. Ion-voltages were adjusted for optimum ionization in HRES-mode and kept constant for IMS-MS measurements. Ionization settings Compound Capillary voltage / [V] Cone Voltage / [kv] Sampling Cone / [V] 1 2.50 30 2.5 2 2.75 40 4 3 2.50 30 2.5 4 2.7 20 4.3 TWIMS Settings For comparability of the IMS-MS measurements, all spectra* were recorded under the same conditions: (*nb. ATD reported in Section 5, Fig S10, recorded with IMS Wave Height = 36.5 V) Trap Gas Flow (ml/min) 4.00 Helium Cell Gas Flow (ml/min) 180.00 IMS Gas Flow (ml/min) 90.00 IMS Wave Velocity (m/s) 750 IMS Wave Height (V) 40.0 CCSs were estimated following calibration with Equine Cytochrome C, and T10 olgiothymidine (both obtained from Sigma Aldrich; used as solutions in 1:1 acetonitrile/water, ph adjusted with conc. NH 4 OH) to determine the instrument-dependent parameters A and B from published CCSs data 5 as previously described in the literature. 6 To obtain IMS spectra the instrument was operated in Sensitivity mode, so charges were assigned with reference to the high resolution MS previously obtained, and, in the case of clusters of clusters, by inference from monomer assignment and unchanged m/z on aggregation. S2

2. High-resolution mass spectra and putative assignments Figure S1. HRES-MS of compound 1. m/z Charge Putative Ion Composition 1627.2 12- (NH 4 ) 12 [Mo 132 O 372 (CH 3 COO) 12 ] 1777.5 11- (NH 4 ) 13 [Mo 132 O 372 (CH 3 COO) 12 ] 1958.4 10- (NH 4 ) 14 [Mo 132 O 372 (CH 3 COO) 12 ] 2207.8 9- (NH 4 ) 18 [Mo 132 O 372 (CH 3 COO) 15 (CH 3 CN)] 2501.9 8- (NH 4 ) 21 [Mo 132 O 372 (CH 3 COO) 17 ] 2888.6 7- (NH 4 ) 24 [Mo 132 O 372 (CH 3 COO) 19 (CH 3 CN)] S3

Figure S2. HRES-MS of compound 2. m/z Charge Putative Ion Composition 2274.1 7- SiMo 12 O 40 Mo 72 Fe 30 O 252 (CH 3 COO) 16 (CH 3 CN) 13 2655.8 6- NaSiMo 12 O 40 Mo 72 Fe 30 O 252 (CH 3 COO) 16 (CH 3 CN) 13 3191.3 5- Na 2 SiMo 12 O 40 Mo 72 Fe 30 O 252 (CH 3 COO) 16 (CH 3 CN) 13 S4

Figure S3. HRES-MS of compound 3. m/z Charge Putative Ion Composition 1656.4 12- (NH 4 ) 12 [Mo 132 O 372 (C 3 H 5 COO) 12 ](CH 3 CN) 1809.0 11- (NH 4 ) 13 [Mo 132 O 372 (C 3 H 5 COO) 12 ](CH3CN) 1992.0 10- (NH 4 ) 14 [Mo 132 O 372 (C 3 H 5 COO) 12 ](CH3CN) 2249.3 9- (NH 4 ) 15 [Mo 132 O 372 (C 3 H 5 COO) 12 ](CH3CN) 8 2544.9 8- (NH 4 ) 16 [Mo 132 O 372 (C 3 H 5 COO) 12 ](CH3CN) 10 2920.9 7- (NH 4 ) 17 [Mo 132 O 372 (C 3 H 5 COO) 12 ](CH3CN) 12 S5

Figure S4. HRES-MS of compound 4. m/z Charge Putative Ion Composition 2148.6 8- (N(C 4 H 9 ) 4 ) 15 KMo 72 V 30 O 282 (SO 4 ) 6 2183.4 8- (N(C 4 H 9 ) 4 ) 14 K 4 Mo 72 V 30 O 282 (SO 4 ) 7 2533.3 7- (N(C 4 H 9 ) 4 ) 14 K 11 Mo 72 V 30 O 282 (SO 4 ) 10 2569.9 7- (N(C 4 H 9 ) 4 ) 14 K 13 Mo 72 V 30 O 282 (SO 4 ) 11 (CH 3 CN) 2 3045.1 6- (N(C 4 H 9 ) 4 ) 15 K 13 Mo 72 V 30 O 282 (SO 4 ) 11 (CH 3 CN) 3 nb. In all spectra (S1-S4) peaks are broad, resulting from a range of ions being formed with a varying mix of cations (native, and others present in solvent/glassware, such as Na +, H + ), associated solvents (H 2 O, acetonitrile) and dissociation of ligands (acetate/butyrate loss). Putative composition assignments are based on plausible ion compositions with calculated m/z close to intensity maximum observed in each peak envelope; many other compositions will undoubtedly contribute to these peak envelopes and these compositions are meant as a guide to understanding, not a definitive assignment. S6

3. Ion-mobility mass spectra Spectra are plotted with m/z on the x-axis and drift time (t D ) on the y-axis. The intensity of the signals is represented by color-coded log scale on a white background, where yellow represents the highest intensity and blue can be disregarded as noise. Figure S5. IMS-MS of compound 1. Aggregation m/z Charge t D (ms) Estimated CCS (Å 2 ) x 1 2864 7 5.73 1051 x 1 2486 8 4.63 1045 x 1 2189 9 3.86 1045 x 1 1959 10 3.31 1050 x 1 1771 11 2.87 1053 x 1 1602 12 2.6 1077 S7

Figure S6. IMS-MS of compound 2. Aggregation m/z Charge t D (ms) Estimated CCS (Å 2 ) x 1 3157 5 6.59 822 x 1 2633 6 4.83 806 x 1 2250 7 3.83 808 x 2 3157 10* 5.31 1428 x 2 2633 12* 3.99 1422 x 3 3157 15* 4.57 1941 *inferred from assignment of aggregation state, ie. as clusters of clusters S8

Figure S7. IMS-MS of compound 3. Aggregation x1 x1 x1 x1 x1 x1 m/z 1656 1809 1992 2249 2545 2921 Charge 7 8 9 10 11 12 t D (ms) 5.84 4.64 3.86 3.32 2.90 2.64 Estimated CCS (Å2) 1060 1042 1038 1045 1052 1080 S9

Figure S8. IMS-MS of compound 4. Aggregation m/z Charge t D (ms) Estimated CCS (Å 2 ) x 1 3045 6 11.69 1436 x 1 2569 7 8.6 1372 x 1 2533 7 8.27 1337 x 1 2184 8 6.39 1292 x 1 2150 8 6.17 1263 S10

4. Fragmentation of clusters in the TWIMS drift tube To confirm the robustness of POM clusters (cf. more delicate biomolecules) under TWIMS conditions, an MSMS experiment was performed to observe the degree of fragmentation of mass-selected ions assigned to intact clusters following transmission through the TWIMS drift tube. A broad mass-filtered selection of the ions assigned to the intact cluster of compound 2 was allowed to pass through the TWIMS cell configured with the settings used to obtain the IMS-MS spectrum reported above, and the spectrum of all the transmitted ions is shown in Figure S9. Negligible fragmentation consistent with the continued integrity of an intact cluster was observed, with a few slightly lower mass ions probably corresponding to the loss of solvent molecules. Figure S9. MS of all ions resulting from 2 transmitted through TWIMS drift cell following quadrupole mass selection (m/z = 3180; LM Resolution = 3). S11

5. Fragmentation of clusters of clusters to yield intact clusters To confirm that large ions observed in IMS-MS spectra do indeed correspond to higher order clusters of clusters assemblies, rather than some other structure, collision-induced dissociation (CID) was used to observe the fragments formed on their disintegration (using energies not previously observed to cause fragmentation of POMs). Mass-selected ions assigned to intact clusters (2; m/z = 3180; z = -5) were passed through an ion trap with CID turned on at two different collision energies (0V, and 17.5V) prior to entering the TWIMS drift tube, and the arrival time distributions (ATDs; Figure S10(a)) and MS spectra (Figure S10(b)) of transmitted ion populations were acquired. Under these conditions the intact clusters (t D = 7.9), and putative dimers (t D = 6.3) were observed in both cases. Where collision energy was raised, the intensity of the ATD peak corresponding to the dimer was halved, while no significant population of fragment ions was observed, strongly suggesting dimer-to-monomer dissociation rather than the fragmentation of some other species. a) b) Collision Energy = 0 V Collision Energy = 17.5 V Figure S10. (a) ATD of ions leaving CID cell at high and low energy; intensity normalized to highest peak. (b) MS resulting from all ions transmitted through TWIMS drift cell in (a). S12

References (1) A. Müller, E. Krickemeyer, H. Bögge, M. Schmidtmann and F. Peters, Angew. Chem. Int. Ed., 1998, 37, 3359. (2) A. M. Todea, J. Szakács, S. Konar, H. Bögge, D. C. Crans, T. Glaser, H. Rousselière, R. Thouvenot, P. Gouzerh and A. Müller, Chem.-Eur. J., 2011, 17, 6635. (3) C. Schäffer, H. Bögge, A. Merca, I. A. Weinstock, D. Rehder, E. T. K. Haupt and A. Müller, Angew. Chem. Int. Ed., 2009, 48, 8051. (4) B. Botar, P. Kögerler and C. L. Hill, Chem. Commun., 2005, 3138. (5) Clemmer Group Cross Section Database. http://www.indiana.edu/~clemmer/research/cross Section Database/cs_database.php (6) S. I. Merenbloom, T. G. Flick and E. R. Williams, J. Am. Soc. Mass. Spectrom., 2012, 23, 553. S13