IR spectral characterization of customer blackbody sources: first calibration results

Similar documents
NIST Radiance Temperature and Infrared Spectral Radiance Scales at Near-Ambient Temperatures

Validation of NIST s Low Temperature Infrared Spectral Radiance Scale

RADIOMETRIC COMPARISON BETWEEN A NATIONAL LABORATORY AND AN INDUSTRIAL LABORATORY

A Study on the Effects of Bandwidth of IR Thermometry Measurements

Traceability and Quality Control in a Radiation Thermometry Laboratory

Calibration capabilities at PTB for radiation thermometry, quantitative thermography and emissivity

Status Update of the NIST Infrared Optical Properties of Materials Program

Infrared Calibration Development at Fluke Corporation Hart Scientific Division

Radiation properties of IR calibrators with V-grooved surfaces

Optimization of Thermal Radiation Source for High Temperature Infrared Thermometer Calibration

Traceability and Quality Control in a Radiation Thermometry Laboratory

Characterization of the VIIRS Blackbody Emittance

Traceability and Quality Control in a Radiation Thermometry Laboratory

Optimization of Thermal Radiation Source for High Temperature Infrared Thermometer Calibration

Emissivity modeling of thermal radiation sources with concentric grooves

Infrared Temperature Calibration 101 Using the right tool means better work and more productivity

Calibrating the Thermal Camera

Absolute Radiance Interferometer: A prototype spaceflight instrument for achieving GSICS and CLARREO goals

ASSET INTEGRITY INTELLIGENCE. Featured Article. ACHIEVING A COMPREHENSIVE FIRED HEATER HEALTH MONITORING PROGRAM By Tim Hill, Quest Integrity Group

Absolute Radiance Re-Calibration of FIRST

Ground and On-Orbit Characterization and Calibration of the Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS)

Characterization of high temperature solar thermal selective absorber coatings at operation temperature

ABB Remote Sensing Atmospheric Emitted Radiance Interferometer AERI system overview. Applications

Infrared Thermometer Calibration A Complete Guide

Total radiation measurements of thermodynamic temperature

The in-flight calibration system for the airborne imager GLORIA

Introduction to Blackbody Sources

Abstract. 1. Introduction

Final Report 06 July 2006 Frank Wilkinson, Gan Xu, and Yuanjie Liu

Infrared Optical Properties of Materials

On-orbit Absolute Blackbody Emissivity Determination Using the Heated Halo Method

Accurate Measurement of Transmittance and Reflectance for Engineering Applications

Investigation of Coherent Emission from the NSLS VUV Ring

Inside Wall Temperature Measurements of DSTs Using an Infrared Temperature Sensor

The steps to an uncertainty budget

PERFORMANCE AND EXAMPLES OF MEASUREMENTS OF A MID INFRARED INTERFEROMETRIC HYPERSPECTRAL IMAGER

DETERMINING SIZE OF SOURCE FOR HANDHELD INFRARED THERMOMETERS THEORY AND PRACTICE

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Characterization and Calibration of a Fourier Transform Spectroradiometer for Solar UV Irradiance Measurements

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Measurement method for the proficiency testing program

Sensors - April A Certified-Emissivity Blackbody for Calibrating Infrared Thermometers

GIFTS Interferometric Noise Sources

SOME ASPECTS OF PYROMETRY OF "WHITE" OBJECTS V.E.

Thermal and structural design constraints for radiometers operating in geostationary orbits. G. E. Zurmehly, R. A. Hookman

Electro-Optical System. Analysis and Design. A Radiometry Perspective. Cornelius J. Willers SPIE PRESS. Bellingham, Washington USA

PD300 PD300-1W PD300-3W PD300-TP

Standards for Radiation Thermometry

Astronomy 203 practice final examination

Physical Basics of Remote-Sensing with Satellites

Thermal And Near infrared Sensor for carbon Observation (TANSO) On board the Greenhouse gases Observing SATellite (GOSAT) Research Announcement

Methods of total spectral radiant flux realization at VNIIOFI

TECHNICAL DESCRIPTION SPECTRAFLOW ON LINE ANALYZER for BELT CONVEYOR APPLICATION

Emissivity, Reflectivity and Transmissivity of Semitransparent Fibre Reinforced Plastic Composites

Solar irradiance measurement up to 2500nm with the Arcoptix FT-NIR

Introduction to Infrared Thermometry

EUV Reflectivity measurements on Acktar Sample Magic Black

Regular Reflectance and Transmittance Measurements of Transmissive Materials Using a STAR GEM Optical Accessory

HIGH TEMPERATURE MEASUREMENT BY THERMOGRAPHY ON CSP

Design Considerations for a Variable Angle Absolute Reflectance Accessory For the LAMBDA 950/850/650 UV/Vis/NIR and UV/Vis Spectrophotometers

Fundamental Concepts of Radiometry p. 1 Electromagnetic Radiation p. 1 Terminology Conventions p. 3 Wavelength Notations and Solid Angle p.

Infrared thermography

Emission Limb sounders (MIPAS)

Atmospheric Lidar The Atmospheric Lidar (ATLID) is a high-spectral resolution lidar and will be the first of its type to be flown in space.

Comparison of the air kerma standards for 137 Cs and 60 Co gamma-ray beams between the IAEA and the NIST. Ronaldo Minniti 1 and Ladislav Czap 2

HARP Assessment of Uncertainty

Fourier Transform Infrared. Spectrometry

Novel Flux Calibration Source. CORM 2007 David C. Gross May 10, 2007

NIST ELECTROSTATIC FORCE BALANCE EXPERIMENT

Chemistry Instrumental Analysis Lecture 15. Chem 4631

SOFIE Instrument Ground Calibration

Experimental confirmation of the negentropic character of the diffraction polarization of diffuse radiation

NIST CERTIFICATION OF ITS-90 FIXED-POINT CELLS FROM K TO K: METHODS AND UNCERTAINTIES

Evaluation at the intermediate focus for EUV Light Source

Operator's Manual. optris BR 400. Calibration source

MTG-IRS processing overview and performances. Dorothee Coppens and Bertrand Theodore

Certificate of Accreditation to ISO/IEC 17025:2005

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

CHAPTER 9 PERFORMANCE OF THE INTERFEROMETER

Overview of NRC Photometry and Radiometry Measurement Services

= (fundamental constants c 0, h, k ). (1) k

A TES Bolometer for THz FT-Spectroscopy

Integrating Spheres in Molecular Spectrophotometry

Far-Infrared Spectroscopy of the Troposphere: Instrument Description and Calibration Performance

Calibration of the Geostationary Imaging Fourier Transform Spectrometer (GIFTS)

Validation of H2O line and continuum spectroscopic parameters in the far infrared wave number range

VSMOW Triple Point of Water Cells: Borosilicate versus Fused- Quartz

I' I, I.

Toward Reliable Industrial Radiation Thermometry

ECE 695 Numerical Simulations Lecture 35: Solar Hybrid Energy Conversion Systems. Prof. Peter Bermel April 12, 2017

Traceability of Absolute Radiometric Calibration for the Atmospheric Emitted Radiance Interferometer (AERI)

Radiation from planets

GSICS Traceability Statement for IASI and AIRS

Calculation of the Effective Emissivities of Speculardiffuse Cavities by the Monte Carlo Method

LED Measurement Instrumentation

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

FTIR Spectrometer. Basic Theory of Infrared Spectrometer. FTIR Spectrometer. FTIR Accessories

Modern Techniques in Applied Molecular Spectroscopy

Introduction to FT-IR Spectroscopy

Introduction to metrology

Transcription:

IR spectral characterization of customer blackbody sources: first calibration results S. Mekhontsev, M. Noorma, A. Prokhorov and L. Hanssen Optical Technology Division National Institute of Standards and Technology Gaithersburg, Maryland 20899-8442 ABSTRACT We summarize recent progress in our infrared (IR) spectral radiance metrology effort. In support of customer blackbody characterization, a realization of the spectral radiance scale has been undertaken in the temperature range of 232 C to 962 C and spectral range of 2.5 µm to 20 µm. We discuss the scale realization process that includes the use of Sn, Zn, Al and Ag fixed-point blackbodies (BB), as well as the transfer of the spectral radiance scale to transfer standard BBs based on water, Cs and Na heat pipes. Further we discuss the procedures for customer source calibration with several examples of the spectral radiance and emissivity measurements of secondary standard BB sources. For one of the BBs, a substantial deviation of emissivity values from the manufacturer specifications was found. Further plans include expansion of the adopted methodology for temperatures down to 15 C and building a dedicated facility for spectral characterization of IR radiation sources. Keywords: infrared, spectral radiance, temperature, fixed-point blackbody, spectral emissivity 1. INTRODUCTION NIST has well established measurements of spectral radiance in the spectral range below 2.5 µm. 1 But many applications critically depend on spectral radiance of calibration sources in the 3 µm to 5 µm and 8 µm to 14 µm ranges, which until now has not been supported by NIST. Several recent papers have demonstrated that Fourier Transform (FT) spectrometers can perform BB radiation measurements with high accuracy 2. To study possible approaches, as well as meet particular needs of one of our customers, we used capabilities of a recently constructed facility for direct measurements of spectral directional emissivity of materials 3 for spectral characterization of BB sources. 2. INFRARED SPECTRAL RADIANCE SCALE REALIZATION APPROACH AND EXPERIMENTAL SETUP Our approach, illustrated in Fig. 1 below, is quite common for spectral radiance realization for higher temperatures and the associated visible and near-ir spectral range. The spectral radiance scale is derived from a set of fixed-point BBs, the design and characterization of which were our first tasks. Secondly, we developed transfer standard pyrometers to maintain and interpolate the temperature scale at particular wavelengths. Thirdly, we constructed a spectral comparator consisting of a spectrometer and fore-optics for spectral scale transfer. Finally, we built and characterized a set of variable temperature blackbodies to maintain the radiance scale and interpolate it over the temperature range, as well as provide convenience of use of relatively large and uniform source not requiring neutral gas purge. snm@nist.gov; phone 1 301 975-8598; fax 1 301 840-8551, nist.gov Thermosense XXVIII, edited by Jonathan J. Miles, G. Raymond Peacock, Kathryn M. Knettel, Proc. of SPIE Vol. 6205, 620503, (2006) 0277-786X/06/$15 doi: 10.1117/12.667523 Proc. of SPIE Vol. 6205 620503-1

Realization Cryogenic Radiometer Absolute Radiation Thermometers ITS-90 Temperature Comparison Planck s Equation Cavity Absorptance Measurements Monte-Carlo Simulation Cavity Effective Emissivity Direct transfer Fixed-Point BB Material Emissivity and BRDF Measurements Spectral Comparison Interpolation Transfer Standard Pyrometers Direct transfer Comparison Spectral Comparison Transfer Standard Variable Temperature BB Direct transfer Dissemination User BB User Pyrometers and Imagers Figure 1: General approach for the spectral radiance scale realization. As mentioned earlier, for this project we used a facility which is a part of the Fourier Transform Infrared Spectrophotometry Laboratory, dedicated to the characterization of the optical properties of solid materials. The Laboratory covers the infrared spectral range of 1 µm to 100 µm, with particular emphasis on the 2 µm to 20 µm region. It is built around several commercial Fourier transform infrared (FTIR) instruments. The relevant part of the setup is shown in Figs. 2 and 3. Ft)rl I Figure 2: Schematic of the experimental setup. For the direct measurement of spectral radiance/emissivity of the radiation source, one must compare its spectral radiance to that of a standard blackbody at a known temperature. The experimental setup consists of a Bomem 4 DA3 FTIR (Fourier Transform InfraRed) spectrometer and a series of two reference blackbodies. A position is also used for the unknown blackbody under test. A transfer standard pyrometer is included to provide NIST traceability for radiation temperature. Our high resolution FT spectrometer is not necessarily optimal to the task of blackbody characterization. Nevertheless, we have been able to demonstrate the concept and obtain useful results. For data processing we have employed an algorithm 5, which involves the spectral comparison of an unknown source with two known sources. Proc. of SPIE Vol. 6205 620503-2

The Bomem FTIR uses interchangeable beam-splitters and detectors to cover a wide spectral interval. For the high temperature portion of this project, from 500 ºC to 1000 ºC, a MCT (Mercury Cadmium Telluride) and pyroelectric detectors and a KBr (Potassium Bromide) beam-splitter are used to provide spectral coverage from 2.5 µm to 22.2 µm. The blackbodies are installed on a moveable platform that allows the arrangement to be controlled in both x- and z- axes. This allows both the pyrometer and the FTIR to be aligned with the two standard blackbodies and the blackbody under test. S lii Figure 3: Blackbody (left) and fore-optics / radiometers (right) sides of the facility. A set of fixed-point BBs, which we have designed, built and characterized, serves as a basis for the spectral radiance scale realization at discrete temperatures. The BBs have 6.5 mm diameter exit apertures and are designed to have high IR emissivity and plateaus of several hours to allow long measurement times. Variable temperature blackbodies based on sodium and cesium heat pipes, are used as transfer standard sources for scale interpolation across the temperature range of interest. The blackbody schematics are shown in Fig. 4; further details of the BB design, results of emissivity modeling and additional evaluations are described elsewhere. 3,6 Temperatures are derived from ITS-90, although a radiometrically based scale derivation will also be attempted in the near future. Figure 4: Schematic of fixed-point (left) and variable temperature heat pipe (right) blackbody standards. Two transfer standard pyrometers, designated RT900 and RT1550, with spectral responsivity centered at 0.9 µm and 1.55 µm, respectively, are used to interpolate the temperature scale between fixed point temperatures, as well as to measure radiance temperature of the customer blackbody. Pyrometer design and evaluation details can be found in another paper presented in this conference 7. The spectral comparator contains fore-optics and a spectrometer. The fore-optics, a schematic of which is shown in Fig. 5, contains two off-axis aspherical mirrors and has a low level of out-of-field scatter in the visible and IR. Details of the Proc. of SPIE Vol. 6205 620503-3

optical train design and characterization can be found elsewhere 8. Size-of-source (SSE) measurements were performed on the interface optics to evaluate the potential errors due to scattering effects. The SSE represents the relative contribution to the measured signal due to radiation from outside the nominal measured area of the source. This can lead to significant measurement error when comparing sources with differing backgrounds. The SSE measurement can be used to evaluate and potentially correct the errors and provide uncertainty contributions. The relatively low value of outof-field scatter correction amounting to 0.025 % in case of comparing sources with diameters of 7 mm and 38 mm means that for radiance measurements other sources of error will dominate the uncertainty budget. Results for both variable source and central obscuration methods for determining the SSE at several wavelengths are consistent and show acceptable performance. Elliptic Fourier Mirror Transform Spectrometer Port Lyot Stop 90 deg ree s Folding Mirror Flat Pointing Mirror with Aperture Stop Rotation Stages Field Stop Blackbodies 13.45 degr ee s Toroidal Mirror Alignment Camera Figure 5: Schematic of the optical interface The measurement chain sequence that we followed is shown in Fig. 6. In the first stage of the experiment, we performed spectral comparisons of variable temperature heat pipe BBs with a number of fixed-point BBs. In the second stage, a customer BB was spectrally compared with variable temperature blackbodies. Spectral Radiance Scale Realization Sn Fixed Point BB 231.928 C Zn Fixed Point BB 419.527 C Al Fixed Point BB 660.323 C Ag Fixed Point BB 961.78 C Spectral Radiance Interpolation Cs Heat Pipe BB 300 to 650 C Na Heat Pipe BB 550 to 1000 C Radiance Temperature Interpolation Pyrometer RT900 500-1000 C Pyrometer RT1550 200-1000 C Dissemination Customer BB Figure 6: Sequence of measurements The effective emissivity was always calculated using the radiance temperature at 1.55 µm as the true (reference) temperature. The spectral radiance and the radiance temperature data were also generated during data processing. Proc. of SPIE Vol. 6205 620503-4

3. EXPERIMENTAL RESULTS 3.1 Measurement algorithm The first step of the blackbody characterization involves obtaining a radiation temperature measurement of both the blackbody under test and the high temperature reference blackbody ( hot reference ). This allows us to deduce the spectral emissivity from knowledge of the measured radiation temperature and the thermodynamic temperature given by the blackbody controller/thermocouple combination. Once the blackbody temperature is stabilized, the radiation temperature at 1.5 µm is measured by aiming the pyrometer at the blackbody apertures of both the hot reference and customer blackbodies. Temperature of the cold reference (a third blackbody at a much lower temperature) is measured by means of contact thermometry. After the radiation temperature is obtained, the FTIR is used to measure the relative spectral radiance of three blackbodies. In our experiment, A represents the reference high temperature blackbody, B references the cold reference blackbody at 20 ºC, and C references the unknown blackbody. The FTIR measurement sequence follows a repeated pattern: A-B-C-B-A-B-C-. The pattern is repeated and averages are taken to reduce drift effects and to decrease the effect of noise in the detector. A typical experiment may take 8 cycles of A-B-C and 128 scans at each blackbody position. Using the measurement equation (see Fig. 7) the spectral radiance L C (ν) is calculated 5. The radiance temperature measured in the last step is used to deduce the spectral emissivity and the radiation temperature as a function of wavelength. C ( ν ) [ VC ( ν ) VB ( ν )] [ V ( ν ) V ( ν )] A B [ L ( ν ) L ( ν )] L ( ν ) L = Re + A B B FT measured complex spectra Figure 7: Measurement equation Products of Planck function & emissivity The data shown below were taken at temperatures that were set identical (within 1-2 degrees C) for both the hot reference blackbody and the unit under test. 3.2 Transfer standard blackbodies characterization Following the aforementioned measurement sequence and algorithm, we performed spectral characterization of our variable temperature blackbody sources based on Cs and Na heat pipes. The resulting spectra of comparison of (a) Na heat pipe vs. Ag fixed point BB; (b) Cs heat pipe vs. Al fixed point BB, and (c) Cs heat pipe vs. Zn fixed point BB are shown in the Fig. 8 below. For these measurements, the instrument was not purged. Hence, artifacts due to atmospheric absorption lines can be seen in the spectra in the regions of CO 2 and H 2 O absorptions. Data in the absorption regions is of variable quality depending on how the much the absorption drifts between measurements. We primarily consider the non-absorbing regions of the spectra in our discussion, including the 3 µm to 4 µm and 8 µm to 14 µm and 15 µm to 16 µm ranges. Proc. of SPIE Vol. 6205 620503-5

a) 1.015 1.010 1.005 0.995 0.985 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 b) 1.015 1.010 1.005 0.995 0.985 c) 1.015 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1.010 1.005 0.995 0.985 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Figure 8: Spectral comparison of a) Na heat pipe vs. Ag fixed point BB; b) Cs heat pipe vs. Al fixed point BB, c) Cs heat pipe vs. Zn fixed point BB. The error bars show the estimated uncertainty (k=2). Proc. of SPIE Vol. 6205 620503-6

Table 1: Uncertainty budget of the measurements of spectral emissivity for the secondary standard BB Temperature, ºC Relative expanded uncertainties (k=2) at different wavelength regions, 10 4 3.4-4.2 µm 4.5-4.8 µm 8-14 µm 300 43 29 26 600 21 18 20 800 24 20 18 1000 25 18 22 4. CUSTOMER BLACKBODY CALIBRATIONS An ideal blackbody is a spatially uniform and temporally stable source with radiance following Planck s law. There are many ways to describe the performance of real-life sources, and before reporting the measurements we need to define our approach. Spectral radiance and wavelength dependent radiance temperature are the only directly measurable quantities characterizing blackbody output for a particular surface element of the exit port and direction (solid angle). Knowledge of the BB spatial uniformity enables us to reduce the number of variables through averaging. Spectral radiance or wavelength dependent radiance temperature should be measured for a range of set temperatures. The commonly used spectral emissivity is a derived unit which makes sense only when calculated and quoted with a clearly defined reference temperature, and obtained from the basic measured result of radiance or radiance temperature. For characterization of customer blackbodies we measure the following: - horizontal/vertical uniformity scan using a transfer standard pyrometer; - short term temporal stability measurement with the transfer standard pyrometer; - radiance temperature measurements at the bb center with the transfer standard pyrometer for each temperature set point of interest; - spectral radiance measurements at each temperature set point of interest with the FTIR comparator; - effective emissivity calculation from the measured spectral radiance, using either the set point temperature or pyrometer radiation temperature as the reference. Calibrated Cs and Na heat pipe blackbodies are used as standards for the measurements of the customer blackbodies for temperatures from 300 C to 1000 C in 100 C steps. An example of this set of characterization measurements for an industrial high temperature blackbody source is shown in Figure 9. Shown are: the temperature stability (a), spatial uniformity (b), spectral radiance (c), radiance temperature (d) and effective spectral emissivity (e). Radiance temperature measured by the radiation pyrometer at 900 nm is used as a reference for the emissivity calculation. Examples of effective spectral emissivity results for two customer blackbody designs are shown in Figures 10, 11 and 12. One blackbody has an Inconel cylindro-conical cavity and a 0.5 inch diameter exit port. Radiance temperatures measured at 0.9 µm and 1.55 µm were found to be within 30 mk of each other. The measured spectral emissivity shown in Figure 8 is close to 1 within the uncertainty limits. A second blackbody has a spherical Inconel cavity with a 0.5 inch diameter exit port. The measurement results for this blackbody, shown in Figures 11 and 12, reveal clear structure in the spectral emissivity. In addition, a systematic difference of 150 mk was found between the radiance temperatures at 0.9 µm and 1.55 µm. The manufacturer specifications include emissivity greater than 0.999. An analysis using our custom sphere modeling software, indicates a possible source for these features in the exit cone temperature non-uniformity combined with a wall coating specularity in the IR. Proc. of SPIE Vol. 6205 620503-7

(a) (b) 610.4 1.2 1.0 Temperature 610.3 610.2 610.1 T variation relative center 0.8 0.6 0.4 0.2 0.0-0.2 T = 500 T = 600 T = 700 T = 800 T = 900 610 (c) 0:00:00 0:30:00 1:00:00 Time, HH:MM:SS (c) -0.4-12 -9-6 -3 0(d) 3 6 9 12 Position, mm, relative center (d) 2500 601.5 Spectral Radiance, W/(cm 3 *sr) 2000 1500 1000 500 2 4 6 8 10 12 14 Wavelength, microns (e) Radiation temperature, deg. C (e) 601.0 600.5 600.0 599.5 2 4 6 8 10 12 14 Wavelength, microns 1.004 Effective Spectral Emissivity 1.003 1.002 1.001 0.999 0.998 2 4 6 8 10 12 14 Wavelength, microns Figure 9: Example of full calibration of an industrial high temperatures blackbody source. Shown are: temperature stability (a), spatial uniformity (b), spectral radiance (c), radiance temperature (d) and effective spectral emissivity (e). Radiance temperature at 0.9 µm is used as the reference for emissivity calculations. Proc. of SPIE Vol. 6205 620503-8

1.006 1.002 0.998 0.994 300 C, Cs 600 C, Cs 800 C, Na 0.986 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Figure 10: Spectral emissivity of cylindro-conical Inconel cavity. Short measurement time and low temperature stability of BB introduce some additional noise and drift. The emissivity of one of these had a distinctive pattern evident at all temperatures (600 C is shown in Fig. 11) 1.005 0.995 0.985 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Figure 11. Customer BB calibration result with a distinctive spectral pattern. Error bars show estimated uncertainties (k=2). Measurements of the second blackbody were made under purge conditions as well as without purge to confirm that the emissivity structure seen was not an artifact due to atmospheric absorption as can be seen in Figure 12. Proc. of SPIE Vol. 6205 620503-9

1.004 No Purge Purge 1.002 0.998 0.996 0.994 0.992 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Figure 12. The spectral emissivity measured for a temperature of 600 C under different atmospheric conditions. Discussion A systematic realization of an IR spectral radiance scale has been performed. In the spectral band of 8 µm to 14 µm, the standard deviation of the mean for spectral radiance was typically at the level of 0.1%. In the spectral band from 3 µm to 5 µm, the scatter of the results for most temperatures is substantially larger, possibly relating to use of a wide band pyroelectric detector, and requires further attention. The results show no systematic spectral features for the transfer standard blackbodies but reveal some systematic features for one of the customer BBs. The results are being used to optimize the design of the dedicated AIRI (Advanced Infrared Radiometry and Imaging) facility for spectral characterization of IR sources currently under construction at NIST. REFERENCES 1. J. H.Walker, R. D. Saunders, and A. T. Hattenburg, Spectral Radiance Calibrations, NBS Spec. Publ. 250-1, 1987. 2. A. L. Reesink, N. L. Rowell, and A. G. Steele, Using Fourier- Transform Blackbody Spectra to Determine Thermodynamic Temperature in the 600 C to 1000 C Range, in Temperature: Its Measurement and Control in Science and Industry, Volume 7, ed. D.C. Ripple, AIP, 19-24, 2003. 3. L.M. Hanssen, S.N. Mekhontsev, V. B. Khromchenko, Infrared spectral emissivity characterization facility at NIST, Proc. SPIE 5405, 1-12, 2004. 4. Disclamer: Certain commercial equipment, instruments, or materials are identified in this paper to specify the experimental procedure adequately. Such identification is not intended to imply recommendation or endorsement by the National Institute of Standards and Technology, nor is it intended to imply that the materials or equipment identified are necessarily the best available for the purpose. 5. H. E. Revercomb, H. Buijs, H. B. Howell, D. D. LaPorte, W. L. Smith, and L. A. Sromovsky, Radiometric calibration of IR Fourier transform spectrometers: Solution to a problem with the High-Resolution Interferometer Sounder. AO 27 (15), 3210-3218, 1988. Proc. of SPIE Vol. 6205 620503-10

6. Mekhontsev, S., Khromchenko, V., Prokhorov, A., Hanssen, L., Emissivity evaluation of fixed-point blackbodies, Proc. TEMPMEKO 2004, vol. 1, ed. D. Zvizdic, University of Zagreb, pp. 581-586. 7. M. Noorma, S.N. Mekhontsev, V.B. Khromchenko, A. Gura, M. Litorja, and L.M. Hanssen, Design and characterization of Si and InGaAs pyrometers for NIST radiance temperature scale realization between 200 C and 962 C, Thermosense 2006. 8. S.N. Mekhontsev and L.M. Hanssen, Low scatter optical system for emittance and temperature measurements, in Temperature: Its Measurement and Control in Science and Industry, Volume 7, ed. D.C. Ripple, AIP, 693-698, 2003. Proc. of SPIE Vol. 6205 620503-11