Laminar Forced Convection and Heat Transfer Characteristics in a Square Channel Equipped with V-Wavy Surface

Similar documents
Convective Heat Transfer and Thermal Performance in a Circular Tube Heat Exchanger Inserted with U-Shaped Baffle

Numerical Investigation on Turbulent Forced Convection in Heating Channel Inserted with Discrete V-Shaped Baffles

Flow and Heat Transfer Profiles in a Square Channel with 45 V-Downstream Orifices

ENERGY PERFORMANCE IMPROVEMENT, FLOW BEHAVIOR AND HEAT TRANSFER INVESTIGATION IN A CIRCULAR TUBE WITH V-DOWNSTREAM DISCRETE BAFFLES

3D Numerical Study on Laminar Forced Convection in V-Baffled Square Channel

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER

EFFECT OF STAGGERED RIB LENGTH ON PERFORMANCE OF SOLAR AIR HEATER USING V-RIB WITH SYMMETRICAL GAP AND STAGGERED RIB

INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 5, ISSUE 09, SEPTEMBER 2016 ISSN

Numerical investigation on turbulent forced convection and heat transfer characteristic in spirally semicircle-grooved tube

Numerical Study on Heat Transfer Enhancement in a Rectangular Duct with V-Shaped Ribs

Numerical and Experimental Investigation of Heat Transfer Using Discrete Ribs

Analysis of Heat Transfer in Pipe with Twisted Tape Inserts

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

International Journal of Advanced Engineering Technology E-ISSN

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review

A Computational Fluid Dynamics Investigation of Solar Air Heater Duct Provided with Inclined Circular Ribs as Artificial Roughness

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

International Communications in Heat and Mass Transfer

Journal of Thermal Science and Technology

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

CFD Analysis for Thermal Behavior of Turbulent Channel Flow of Different Geometry of Bottom Plate

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

The Effect of Solid and Perforated Pin Fin on the Heat Transfer Performance of Finned Tube Heat Exchanger

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Numerical Heat Transfer Study of Turbulent Square Duct Flow through W-Type Turbulators

Theoretical prediction of performance of Single and Double pass solar air heaters with artificial roughened absorber plates

Effective Heat Transfer Enhancement in Finned Tube Heat Exchanger with Different Fin Profiles

Thermo Hydraulic Performance of Solar Air Heater by Using Double Inclined Discrete Rib Roughened Absorber Plate

Heat transfer and fluid flow analysis of roughness ribin solar air heater duct by computational fluid dynamics (CFD)

Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of Roughened Solar Air Heater Duct

Forced Convection Heat Transfer Enhancement by Porous Pin Fins in Rectangular Channels

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib

STUDY OF FLOW & HEAT TRANSFER IN PLATE FIN HEAT EXCHANGER AT VARYING REYNOLD S NO

Experimental investigation of heat transfer augmentation in triangular duct with rectangular wing

COMPUTATIONAL FLUID DYNAMICS ANALYSIS ON HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF A TURBULENT FLOW FOR INTERNALLY GROOVED TUBES

A REVIEW OF HEAT TRANSFER AND LAMINAR FLOW IN A MICROCHANNEL

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls

A CFD Analysis Of A Solar Air Heater Having Triangular Rib Roughness On The Absorber Plate

EFFECT OF DIFFERENT PARAMETERS ON THE PERFORMANCE OF RIB ROUGHNESS SOLAR DUCT

Effect of roughness shape on heat transfer and flow friction characteristics of solar air heater with roughened absorber plate

CFD Analysis of Heat Transfer through Artificially Roughened Solar Duct

CFD based flow and heat transfer analysis of various ribs in solar air heater duct by continuous ribs on absorber plate

Numerical study of heat transfer enhancement by rectangular winglet vortex generator pair in a channel

W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater

Principles of Convection

ENHANCEMENT OF HEAT TRANSFER FOR AIR FLOW THROUGH A DUCT WITH VARIOUS RIBS

Heat Transfer Enhancement of Solar Air Heater By Using Artificial Roughness double inclined ribs

THE EFFECTS OF LONGITUDINAL RIBS ON ENTROPY GENERATION FOR LAMINAR FORCED CONVECTION IN A MICROCHANNEL

Numerical investigation of heat transfer enhancement in a pipe heat exchanger by adding nano particle and twisted tape

NUMERICAL SIMULATION ON RECTANGULAR CONVERGENT AND DIVERGENT RIBBED CHANNELS

HEAT TRANSFER AND FLOW CHARACTERISTICS OF OFFSET FIN AND FLAT TUBE HEAT EXCHANGERS UNDER LOW PRESSURE ENVIRONMENT

Performance of Elliptical Pin Fin Heat Exchanger with Three Elliptical Perforations

Effect of rib height on heat transfer and friction factor in a square channel roughened by inclined ribs with a gap

PERIODICALLY FULLY DEVELOPED LAMINAR FLOW AND HEAT TRANSFER IN A 2-D HORIZONTAL CHANNEL WITH STAGGERED FINS

Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO Nano fluid

HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF COMPOUND TURBULATORS IN RECTANGULAR DUCTS OF SOLAR AIR HEATER

Numerical Investigation on Air Side Performance of Fin and Tube Heat Exchnagers with Different Types of Fins

Numerical analysis of fluid flow and heat transfer in 2D sinusoidal wavy channel

SIMULATION OF FLOW STRUCTURE AND HEAT TRANSFER ENHANCEMENT IN A TRIANGULAR DUCT WITH RECTANGULAR WING

Review of Roughness Enhancement of Solar Air Heaters having Different Rib Roughness Geometries on Absorber Plate

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

HEAT TRANSFER BY CONVECTION. Dr. Şaziye Balku 1

Effect of V-Shape Twisted Jaw Turbulators on Thermal Performance of Tube heat exchanger: An Experimental Study

SSRG International Journal of Mechanical Engineering ( SSRG IJME ) Volume 2 Issue 5 May 2015

Forced Convection Heat Transfer Augmentation from Ribbed Surface

International Journal of Advanced Engineering Research and Studies E-ISSN

PHYSICAL MECHANISM OF CONVECTION

Comparative Analysis of Heat Transfer and Friction Characteristics in a Corrugated Tube

Australian Journal of Basic and Applied Sciences. Heat transfer enhancement of laminar flow in a circular tube using Swirl / vortex generator

Fluid Flow and Heat Transfer Characteristics in Helical Tubes Cooperating with Spiral Corrugation

CHME 302 CHEMICAL ENGINEERING LABOATORY-I EXPERIMENT 302-V FREE AND FORCED CONVECTION

Entropy 2011, 13, ; doi: /e OPEN ACCESS. Entropy Generation at Natural Convection in an Inclined Rectangular Cavity

Circle one: School of Mechanical Engineering Purdue University ME315 Heat and Mass Transfer. Exam #2. April 3, 2014

Design of an innovative internal structure for surface solar air heater s

CFD analysis of solar air heater having absorber plate roughened with compound turbulators

A Numerical Study of Forced Convection Heat Transfer for Staggered Tube Banks in Cross-Flow

Second Law Analysis of Forced Convective Cooling in a Channel with a Heated Wall Mounted Obstacle

Optimization of flue gas turbulent heat transfer with condensation in a tube

"Experimental investigation of heat transfer enhancement by u-shaped Turbulator"

Experimental Investigation of Single-Phase Friction Factor and Heat Transfer inside the Horizontal Internally Micro-Fin Tubes.

A numerical study of heat transfer and fluid flow over an in-line tube bank

Numerical Analysis of a Multi-Row Multi-Column Compact Heat Exchanger

MYcsvtu Notes HEAT TRANSFER BY CONVECTION

Augmented Heat Transfer in Square ducts with Transverse and Inclined Ribs with and without a gap

Maximum Heat Transfer Density From Finned Tubes Cooled By Natural Convection

Experimental and Numerical Studies of Heat Transfer Characteristics for Impinging Jet on Dimple Surfaces

Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced Convection

Experimental Heat transfer study of Turbulent Square duct flow through V type turbulators

Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of Square Type Tabulator Roughness Solar Air Heater

Transitional Flow and Heat Transfer Characteristics in a Rectangular Duct with Stagger-arrayed Short Pin Fins

Heat Transfer Enhancement in Turbines using Dimples- A CFD Study Nitish Kumar Jain 1 Dr.U.S. Mallikarjun 2

Exergetic Performance Evaluation and Comparative Study of A Roughened Solar Air Heater using MATLAB

FLOW MALDISTRIBUTION IN A SIMPLIFIED PLATE HEAT EXCHANGER MODEL - A Numerical Study

LAMINAR NATURAL CONVECTION HEAT TRANSFER FROM AN ISOTHERMAL VERTICAL RIBBED PLATE

Chapter 3 NATURAL CONVECTION

Heat Transfer Performance in Double-Pass Flat-Plate Heat Exchangers with External Recycle

Research Article. Kaustubh G. Kulkarni * and Mandar M. Lele. Abstract

Heat Transfer Convection

Transcription:

Journal of Mathematics and Statistics Original Research Paper Laminar Forced Convection and Heat Transfer Characteristics in a Square Channel Equipped with V-Wavy Surface 1 Amnart Boonloi and 2 Withada Jedsadaratanachai 1 Department of Mechanical Engineering Technology, College of Industrial Technology, King Mongkut s University of Technology North Bangkok, Bangkok 10800, Thailand 2 Department of Mechanical Engineering, Faculty of Engineering, King Mongkut s Institute of Technology Ladkrabang, Bangkok 10520, Thailand Article history Received: 11-06-2017 Revised: 24-07-2017 Accepted: 25-07-2017 Corresponding Author: Withada Jedsadaratanachai Department of Mechanical Engineering, Faculty of Engineering, King Mongkut s Institute of Technology Ladkrabang, Bangkok 10520, Thailand Email: kjwithad@kmitl.ac.th Abstract: The numerical investigations on flow pattern and heat transfer characteristic in a heat exchanger channel equipped with V- wavy surface are examined. The influences of the flow attack angles (α = 15, 20, 25, 30, 35, 40, 45, 50, 55 and 60 ) and wavy surface arrangements (V-tip pointing downstream called V-Downstream, V- tip pointing upstream called V-Upstream) are investigated for laminar regime, Re = 100-1200. The finite volume method with SIMPLE algorithm is used to solve the current research. The numerical result shows that the addition of the wavy surface in the heat exchanger channel can help to develop the heat transfer rate and thermal performance. The wavy surface generates the vortex flow through the test section that disturbs the thermal boundary layer on the heat transfer surface. The insertion of the wavy surface in the heating channel gives higher heat transfer rate around 1.5-10 times above the smooth channel depended on the flow attack angle, Reynolds number and wavy surface arrangement. In addition, the optimum thermal performance is around 3.0 at Re = 1200, α = 40 and V-Upstream. Keywords: Heat Transfer Rate, Thermal Performance, Wavy Surface, Heat Exchanger, Finite Volume Method Introduction The effort to improve the thermal performance in various types of the heat exchangers is always seen in many industries. The thermal development can help to save production cost, thermal energy and also reduce the size of the heating system. The thermal development in the heat exchanger is divided into two methods; active and passive methods. The active method needs the additional power to enhance heat transfer rate and thermal performance, while the passive method is to generate vortex flow, swirling flow and to disturb the thermal boundary layer by turbulator or vortex generators. The passive method is more popular than the active method. Many researchers attempt to create the appropriate vortex generator for various engineering works. For examples, the wavy surface (Duan et al., 2016; Khoshvaght-Aliabadi et al., 2016; Lotfi et al., 2016; Lu et al., 2017; Ranganayakulu et al., 2017; Xiao et al., 2017; Xu et al., 2015) is widely selected to augment heat transfer rate and performance in fin-and-tube heat exchanger. The wavy surface performs a better fluid mixing in the heating section that the reason for heat transfer augmentation. The amplitude, profile, flow attack angle, etc., of the wavy surface are important parameters that effect for heat transfer rate and thermal efficiency in the heat exchanger. The distinctive points of the wavy surface are as follows; easy for manufacture and maintenance, low pressure loss. The V-rib/baffle (Abraham and Vedula, 2016; Deo et al., 2016; Fang et al., 2015; Jin et al., 2017; 2015; Kumar and Kim, 2016; Maithani and Saini, 2016; Promthaisong et al., 2016; Ravi and Saini, 2016; Singh and Ekkad, 2017) is another type of the vortex generators, which always use to increase heat transfer 2017 Amnart Boonloi and Withada Jedsadaratanachai. This open access article is distributed under a Creative Commons Attribution (CC-BY) 3.0 license.

rate and thermal performance in tube/channel heat exchanger. The V-rib gives high heat transfer rate and thermal performance, but also performs enlarge pressure loss. The new design of the vortex generators is the combination between wavy surface and V-rib called Vwavy surface. The main aim of the new design is to support the generators production, maintenance and to remain the performance as the V-rib. In the current research, the V-wavy surface is inserted in the middle of the heat exchanger channel to improve heat transfer rate and thermal efficiency. The influences of the flow attack angle (α = 15, 20, 25, 30, 35, 40, 45, 50 and 60 ), V-wavy surface arrangement (V-Downstream and V-Upstream) and Reynolds number (laminar flow, Re = 100-1200) on heat transfer, friction loss and thermal performance are investigated numerically. The numerical method can help to describe the flow and heat transfer mechanisms in the test section that is a way to improve the thermal system. The numerical results are reported in terms of flow visualizations, heat transfer characteristics and performance assessments. Channel Geometry and Arrangement Figure 1 presents a heat exchanger channel inserted with V-wavy surface. The square channel height, H, is equal to 0.05 m. The square profile of the wavy surface is fixed at 0.2H 0.2H. The flow attack angle of the wavy surface is varied; α = 15, 20, 25, 30, 35, 40, 45, 50, 55 and 60. The arrangement of the V-wavy surface is divided into two methods; V- tip pointing upstream called V-Upstream and V-tip pointing downstream called V-Downstream. The periodic module of the present investigation is set around H. The laminar flow, Re = 100-1200, is considered for the present study. Fig. 1. Square channel inserted with V-wavy surface and computational domain 252

Assumption and Boundary Condition The current work is investigated under following assumptions: The thermal properties of the test fluid (air) stay constant at average bulk mean temperature. The Prandtl number of the test fluid is around 0.707. The flow and heat transfer are steady in three dimensions. The laminar flow with incompressible condition is considered for the present study. The force convection is regarded. The body force, viscous dissipation, radiation heat transfer and natural convection are unconsidered. The computational domain is created with the boundary conditions as follows: The inlet and outlet of the domain are produced with periodic boundary. The channel walls are set with constant temperature around 310 K. No slip wall condition is used for all surfaces of the computational domain. The V-wavy surface is assumed as adiabatic wall (insulator). Mathematical Foundation The heating channel is governed by the continuity, the Navier-Stokes equations and the energy equation as Equation 1-3, respectively. Continuity equation: i x ρu i ( ) = 0 Momentum equation: (1) The energy equation and governing equations are discretized by the QUICK scheme and power law scheme, respectively. The present investigation is answered by finite volume method. The SIMPLE algorithm is selected for the test. The solutions are measured to be converged when the normalized residual values are less than 10 5 for all variables, but less than 10 9 only for the energy equation. The important variables are Reynolds number, friction factor, local Nusselt number, average Nusselt number and thermal enhancement factor. The Reynolds number is calculated by: Re= ρ ud µ (5) h The friction factor, f, is determined by pressure drop, p, through the periodic module, L: f Nu ( p L) D = h (6) 1 2 ρu 2 The local heat transfer is written as: h D k x h x = (7) The average Nusselt number can be obtained by: 1 Nu= Nux A A (8) The Thermal Enhancement Factor (TEF) is considered by the augmentations on both heat transfer and friction factor at similar pumping power: h Nu TEF = ( Nu Nu ) ( ) 1 3 0 f f0 h = Nu = (9) 0 pp 0 pp ( ρu u ) i j p u u i j = + µ + x j xi x j x j x i (2) The Nusselt number and friction factor for the smooth square channel are represented by Nu 0 and f 0, respectively. Energy equation: T ( ρuit) = Γ xi x j x j Γ is the thermal diffusivity, which equal to: (3) µ Γ= (4) Pr Numerical Validation Figure 2 shows the verification of the smooth heat exchanger channel on heat transfer and friction loss. The comparison of the numerical scheme with the value from the correlation is also reported. As the figure, it is found that the difference of the numerical scheme has no effect for the numerical result on both flow and heat transfer. The deviations on the Nusselt number and friction loss are less than ±0.5%. 253

Fig. 2. Validation of the smooth square channel and numerical scheme comparison Fig. 3. Grid independence for Nu/Nu 0 and f/f 0 Figure 3a and b plot the grid independence on heat transfer and friction loss for the computational domain of the heat exchanger channel inserted with V-wavy surface, respectively. The five different grid cells; 80000, 120000, 240000, 360000 and 420000, are compared. The numerical result shows that the increasing grid cell from 240000 to 360000 has no effect for friction factor and Nusselt number. Therefore, the grid around 240000 is applied for all cases of the present investigation. The optimum number of grid cell can help to save time for investigation and computer resource. Numerical Result Flow and Heat Transfer Mechanism Figure 4a and b illustrate the tangential velocity vector in transverse planes (x/h = 0.5, 1.75, 3, 4.25 and 5.5) for the heat exchanger channel inserted with V- Downstream and V-Upstream wavy surfaces, respectively, at Re = 600 and α = 45. The insertion of the wavy surface on both arrangements changes the flow structure in the square channel. The wavy surface can create the vortex flow through the test section. The vortex flow disturbs the thermal boundary layer on the heat transfer surface that helps to improve the heat transfer rate and thermal performance. The vortex flow in the channel heat exchanger is detected in all cases. Figure 5a and b report the temperature distribution in transverse planes for the heat exchanger channel inserted with the V-Downstream and V-Upstream wavy surface, respectively, at Re = 600 and α = 45. The installation of the wavy surface in the heat exchanger channel performs a better mixing of the air flow. The cold fluid distributes from the center of the channel, while the hot fluid near the channel wall performs thinner. The improvement of 254

the heat transfer rate and thermal performance is due to the better fluid mixing. Performance Analysis The relations of the Nu/Nu 0 with Re at various flow attack angles for the heat exchanger channel installed with V-Downstream and V-Upstream wavy surfaces are plotted as Figure 6a and b, respectively. In general, the Nu/Nu 0 increases when enhancing the Reynolds number for both arrangements. The installation of the wavy surface in the heat exchanger channel provides higher heat transfer rate than the smooth square channel (Nu/Nu 0 > 1) in all cases. The heat transfer rate is around 2-9 and 1.5-10 times above the smooth channel for the wavy surface with V- Downstream and V-Upstream, respectively. Fig. 4. Tangential velocity vector in transverse planes for the heat exchanger channel inserted with V-wavy surface of V- Downstream and V-Upstream at Re = 600 and α = 45 255

Fig. 5. Temperature distribution in transverse planes for the heat exchanger channel inserted with V-wavy surface of V- Downstream and V-Upstream at Re = 600 and α = 45 Fig. 6. Nu/Nu 0 Vs Re for the heat exchanger channel inserted with V-wavy surface of V-Downstream and V-Upstream The variations of the f/f 0 with the Reynolds number at various flow attack angles for the square channel inserted with V-Downstream and V-Upstream wavy surfaces are depicted as Figure 7a and b, respectively. The present of the wavy surface in the channel heat exchanger not only increases in heat transfer rate, but also enhances the pressure loss. The insertion of the wavy surface provides higher friction loss than the smooth channel for both arrangements (f/f 0 > 1). The f/f 0 is around 6-45 and 6-43 for the wavy surface with V-Downstream and V-Upstream, respectively. Figure 8a and b present the relations of the thermal enhancement factor with the Reynolds number at various flow attack angles for the square channel inserted with V-Downstream and V-Upstream wavy surfaces, respectively. The TEF increases when augmenting the Reynolds number, except from α = 55 and 60 of the V-Downstream wavy surface. Almost cases, the insertion of the wavy surface gives higher thermal performance than the smooth channel (TEF > 1). In the range investigates, the TEF is around 1.05-2.6 and 0.8-3.0 for V-Downstream and V-Upstream wavy surfaces, respectively. 256

Fig. 7. f/f 0 Vs Re for the heat exchanger channel inserted with V-wavy surface of V-Downstream and V-Upstream Fig. 8. TEF Vs Re for the heat exchanger channel inserted with V-wavy surface of V-Downstream and V-Upstream Fig. 9. Nu/Nu 0 Vs α for the heat exchanger channel inserted with V-wavy surface of V-Downstream and V-Upstream 257

Fig. 10. f/f 0 Vs α for the heat exchanger channel inserted with V-wavy surface of V-Downstream and V-Upstream Fig. 11. TEF Vs α for the heat exchanger channel inserted with V-wavy surface of V-Downstream and V-Upstream Figure 9a and b report the variations of the Nu/Nu 0 with the flow attack angle at various Reynolds numbers for V-Downstream and V-Upstream wavy surfaces, respectively. In range 15 α 40, the heat transfer rate increases when increasing the flow attack angle. The heat transfer rate decreases when α > 40. The peak of heat transfer rate is found at the flow attack angle of 40 on both arrangements. Figure 10a and b present the relations of the f/f 0 with the flow attack angle at various Reynolds number for V-Downstream and V-Upstream, respectively. In range 15 α 45 for V-Downstream, the f/f 0 increases when increasing the flow attack angle. The friction factor decreases when α > 45 for V- Downstream. For V-Upstream in range 15 α 40, the f/f 0 increases when enhancing the flow attack angle. The friction loss reduces when α > 40 for V- Upstream. In conclusion, the peak of the friction factor in the heat exchanger channel inserted with V- Downstream and V-Upstream wavy surfaces is detected at 45 and 40, respectively. Figure 11a and b report the relations of the TEF with the flow attack angle for the heat exchanger channel inserted with V-Downstream and V-Upstream wavy surfaces, respectively. The optimum TEF is found at the flow attack angle of 30 and 40 for V-Downstream and V-Upstream wavy surfaces, respectively. Conclusion Numerical investigations on flow and heat transfer in a square channel inserted with V-wavy surface are reported. The influences of flow attack angle, V-wavy surface arrangement and Reynolds number on heat transfer and friction factor are studied. The major findings are concluded as follows; 258

The addition of the wavy surface can improve the heat transfer rate and thermal performance due to the wavy surface generates the vortex flow that disturbs the thermal boundary layer on the heat transfer surface. The heat transfer rate enhances around 1.5-10 times higher than the smooth channel when inserting the wavy surface in the heating system. The insertion of the wavy surface gives the pressure loss around 6-45 times over the plain channel. The peak of heat transfer rate is found at the flow attack angle of 40 for both arrangements, while the peak of the friction loss is detected at the flow attack angle of 40 and 50, respectively, for V-Downstream and V- Upstream. The optimum TEF is around 2.6 and 3.0 for 30 V- Downstream and 40 V-Upstream, respectively, at Re = 1200. Acknowledgement The authors would like to acknowledge Assoc. Prof. Dr. Pongjet Promvonge for suggestions. Funding Information The research was funded by King Mongkut s Institute of Technology Ladkrabang research fund and King Mongkut s University of Technology North Bangkok. Ethics This article is original and contains unpublished material. The corresponding author confirms that all of the other authors have read and approved the manuscript and no ethical issues involved. References Abraham, S. and R.P. Vedula, 2016. Heat transfer and pressure drop measurements in a square crosssection converging channel with V and W rib turbulators. Exp. Therm. Fluid Sci., 70: 208-219. DOI: 10.1016/j.expthermflusci.2015.09.003 Deo, N.S., S. Chander and J.S. Saini, 2016. Performance analysis of solar air heater duct roughened with multigap V-down ribs combined with staggered ribs. Renew. Energ., 91: 484-500. DOI: 10.1016/j.renene.2016.01.067 Duan, F., K.W. Song, H.R. Li, L.M. Chang and Y.H. Zhang et al., 2016. Numerical study of laminar flow and heat transfer characteristics in the fin side of the intermittent wavy finned flat tube heat exchanger. Applied Therm. Eng., 103: 112-127. DOI: 10.1016/j.applthermaleng.2016.04.081 Fang, X., Z. Yang, B.C. Wang, M.F. Tachie and D.J. Bergstrom, 2015. Highly-disturbed turbulent flow in a square channel with V-shaped ribs on one wall. Int. J. Heat Fluid Flow, 56: 182-197. DOI: 10.1016/j.ijheatfluidflow.2015.07.008 Jin, D., J. Zuo, S. Quan, S. Xu and H. Gao, 2017. Thermohydraulic performance of solar air heater with staggered multiple V-shaped ribs on the absorber plate. Energy, 127: 68-77. DOI: 10.1016/j.energy.2017.03.101 Jin, D., M. Zhang, P. Wang and S. Xu, 2015. Numerical investigation of heat transfer and fluid flow in a solar air heater duct with multi V-shaped ribs on the absorber plate. Energy, 89: 178-190. DOI: 10.1016/j.energy.2015.07.069 Khoshvaght-Aliabadi, M., A. Jafari, O. Sartipzadeh and M. Salami, 2016. Thermal-hydraulic performance of wavy plate-fin heat exchanger using passive techniques: Perforations, winglets and nanofluids. Int. Commun. Heat Mass, 78: 231-240. DOI: 10.1016/j.icheatmasstransfer.2016.09.019 Kumar, A. and M.H. Kim, 2016. Heat transfer and fluid flow characteristics in air duct with various V- pattern rib roughness on the heated plate: A comparative study. Energy, 103: 75-85. DOI: 10.1016/j.energy.2016.02.149 Lotfi, B., B. Sundén and Q. Wang, 2016. An investigation of the thermo-hydraulic performance of the smooth wavy fin-and-elliptical tube heat exchangers utilizing new type vortex generators. Applied Energy., 162: 1282-1302. DOI: 10.1016/j.apenergy.2015.07.065 Lu, G., J. Zhao, L. Lin, X.D. Wang and W.M. Yan, 2017. A new scheme for reducing pressure drop and thermal resistance simultaneously in microchannel heat sinks with wavy porous fins. Int. J. Heat Mass Transfer, 111: 1071-1078. DOI: 10.1016/j.ijheatmasstransfer.2017.04.086 Maithani, R. and J.S. Saini, 2016. Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with V-ribs with symmetrical gaps. Exp. Therm. Fluid Sci., 70: 220-227. DOI: 10.1016/j.expthermflusci.2015.09.010 Promthaisong, P., P. Eiamsa-Ard, W. Jedsadaratanachai and S. Eiamsa-Ard, 2016. Turbulent heat transfer and pressure loss in a square channel with discrete broken V-rib turbulators. J. Hydrodyn., 28: 275-283. DOI: 10.1016/S1001-6058(16)60629-7 Ranganayakulu, C., X. Luo and S. Kabelac, 2017. The single-blow transient testing technique for offset and wavy fins of compact plate-fin heat exchangers. Applied Therm. Eng., 111: 1588-1595. DOI: 10.1016/j.applthermaleng.2016.05.118 259

Ravi, R.K. and R.P. Saini, 2016. Experimental investigation on performance of a double pass artificial roughened solar air heater duct having roughness elements of the combination of discrete multi V shaped and staggered ribs. Energy, 116: 507-516. DOI: 10.1016/j.energy.2016.09.138 Singh, P. and S. Ekkad, 2017. Experimental study of heat transfer augmentation in a two-pass channel featuring V-shaped ribs and cylindrical dimples. Applied Therm. Eng., 116: 205-216. DOI: 0.1016/j.applthermaleng.2017.01.098 Xiao, L., T. Wu, S. Feng, X. Du and L. Yang, 2017. Experimental study on heat transfer enhancement of wavy finned flat tubes by water spray cooling. Int. J. Heat Mass Transfer, 110: 383-392. DOI: 10.1016/j.ijheatmasstransfer.2017.03.054 Xu, C., L. Yang, L. Li and X. Du, 2015. Experimental study on heat transfer performance improvement of wavy finned flat tube. Appl. Therm. Eng., 85: 80-88. DOI: 10.1016/j.applthermaleng.2015.02.024 Nomenclature D h hydraulic diameter of the square channel, m H square channel height, m f friction factor h convective heat transfer coefficient, W m 2 K 1 L periodic length, m Nu Nusselt number P static pressure, Pa Pr Prandtl number Re Reynolds number, (ρu 0 D h /µ) T temperature, K TEF thermal performance enhancement factor, (Nu/Nu 0 )/(f/f 0 ) 1/3 Greek Letter µ dynamic viscosity, kg s 1 m 1 ρ density, kg m 3 α flow attack angle Subscript 0 smooth duct pp pumping power 260