Politecnico, Dipartimento di Energetica, Torino, I-10129, Italy

Similar documents
REFRIGERATION OF LOW-TEMPERATURE SUPERCONDUCTING COILS FOR NUCLEAR FUSION

Heat slug propagation in QUELL. Part I: Experimental setup and 1- uid GANDALF analysis

Evaluation of the Current Sharing Temperature of the ITER Toroidal Field Model Coil

Heat slug propagation in QUELL. Part II: 2- uid MITHRANDIR analysis

Self Field Measurements by Hall Sensors on the SeCRETS Long Sample CICCs in SULTAN

Supercritical Helium Cooling of the LHC Beam Screens

EU Contribution to the Test and Analysis of the ITER Poloidal Field Conductor Insert (PFCI)

Thermo-structural and heat load analysis of SST-1 Superconducting coils

Multi-scale approach to the thermal modelling of the ITER superconducting magnets

EDIPO Test Facility User Specification

CERN, 1211 Geneva 23, Switzerland *Laboratoire des Signaux et Systèmes, UMR 8506 CNRS-Supélec, Gif-sur-Yvette, France

Qualification Tests and Facilities for the ITER Superconductors

THE CERN CRYOGENIC TEST FACILITY FOR THE ATLAS BARREL TOROID MAGNETS

1798 IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, VOL. 16, NO. 2, JUNE 2006

HiLumi LHC FP7 High Luminosity Large Hadron Collider Design Study. Milestone Report. Cryogenic Scenarios for the Cold Powering System

Helium two-phase flow in a thermosiphon open loop

Schroeder, C., Walter, F., Marzouki, F., Stafiniac, A., Floch, E., Schnizer, P., Moritz, G., Xiang, Y., Kauschke, M., Meier, J., Hess, G.

PUBLICATION. Thermal Design of an Nb3Sn High Field Accelerator Magnet

Large Superconducting Conductors and Joints for Fusion Magnets : from Conceptual Design to Test at Full Size Scale

Current Leads, Links and Buses

Gesellschaft für Schwerionenforschung mbh (GSI), Planckstrasse 1, D Darmstadt, Germany

Stability Analysis of the Interconnection of the LHC Main Superconducting Bus Bars

CURRENT LEADS FOR THE LHC MAGNET SYSTEM

HE II HEAT EXCHANGER TEST UNIT FOR THE LHC INNER TRIPLET

LHC HTS CURRENT LEADS

B1-1. Closed-loop control. Chapter 1. Fundamentals of closed-loop control technology. Festo Didactic Process Control System

Steven W. Van Sciver. Helium Cryogenics. Second Edition. 4) Springer

Helium two-phase flow in a thermosiphon open loop

Analysis and interpretation of the full set ( ) of T CS tests in conductor 1A of the ITER Central Solenoid Model Coil

High Temperature Superconductors for Fusion at the Swiss Plasma Center

Innovative fabrication method of superconducting magnets using high T c superconductors with joints

Calculation of minimum Quench Energies in Rutherford Cables

DYNAMICS OF A LIQUID HELIUM I CRYOSTAT AT THE CANADIAN LIGHT SOURCE. C. Regier1. Canadian Light Source Inc. Saskatoon, SK, S7N 0X4, Canada.

Development of cable in conduit conductor for ITER CS in Japan

A review of thermal-hydraulic issues in ITER cable-in-conduit conductors

Technische Universität Dresden Lehrstuhl für Kälte- und Kryotechnik Dresden, 01062, Germany

LEAKLESS COOLING SYSTEM V.2 PRESSURE DROP CALCULATIONS AND ASSUMPTIONS

1074 IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, VOL. 21, NO. 3, JUNE 2011

3D Simulation of the Plunger Cooling during the Hollow Glass Forming Process Model, Validation and Results

Piping Systems and Flow Analysis (Chapter 3)

Critical Current Properties of HTS Twisted Stacked-Tape Cable in Subcooled- and Pressurized-Liquid Nitrogen

JOINTS FOR SUPERCONDUCTING MAGNETS

HT-7U* Superconducting Tokamak: Physics design, engineering progress and. schedule

Thermal-hydraulic analysis of LTS cables for the DEMO TF coil using simplifi ed models*

Keywords: Superconducting Fault Current Limiter (SFCL), Resistive Type SFCL, MATLAB/SIMULINK. Introductions A rapid growth in the power generation

High Magnetic Field Facility for Neutron Scattering

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH Laboratory for Particle Physics

He II Heat transfer through a Corrugated Tube - Test Report

Energy Conversion in the Peltier Device

Cryogenic Viscous Compressor Development and Modeling for the ITER Vacuum System

THERMOHYDRAULIC BEHAVIOUR OF HEII IN STRATIFIED CO-CURRENT TWO-PHASE FLOW AT HIGH VAPOR VELOCITIES

Notkestraße 85, 22607, Hamburg, Germany

Microscopy Cryostat System

24 volts (0.25 amps current-limited)

Electromagnetic, stress and thermal analysis of the Superconducting Magnet

MASSACHUSETTS INSTITUTE OF TECHNOLOGY DEPARTMENT OF MECHANICAL ENGINEERING DEPARTMENT OF NUCLEAR ENGINEERING 2.64J/22.68J , : & HTS

Measurements of temperature on LHC thermal models

IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, VOL. 14, NO. 2, JUNE A. Nijhuis, Yu. Ilyin, W. Abbas, B. ten Haken, and H. H. J.

Electromagnetic Induction Faraday s Law Lenz s Law Self-Inductance RL Circuits Energy in a Magnetic Field Mutual Inductance

Optimization model of a structural simulation design for a CICC

Which Superconducting Magnets for DEMO and Future Fusion Reactors?

Lecture #2 Design Guide to Superconducting Magnet

RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP

Retraining of the 1232 Main Dipole Magnets in the LHC

The development of a Roebel cable based 1 MVA HTS transformer

Physics 7B-1 (A/B) Professor Cebra. Winter 2010 Lecture 2. Simple Circuits. Slide 1 of 20

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Development of a cryogenic induction motor for use with a superconducting magnetic bearing

Low Temperature Instrumentation: Detectors, Cooling Systems and Superconducting Magnets LOW TEMPERATURE INSTRUMENTATION - DDAYS

Cryogenic and Electrical Test Results of a 30 M HTS Power Cable

Superconduttivita e Criogenia

Influence of the voltage taps position on the self-field DC and AC transport characterization of HTS superconducting tapes

Grounding and Shielding

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

Conceptual design of the cryogenic system and estimation of the recirculated power for CFETR

Field Errors Decay and Snap-Back in LHC Model Dipoles

Common approach for thermal-hydraulic calculations

Week 8. Steady Flow Engineering Devices. GENESYS Laboratory

Precise Thermometry for Next Generation LHC Superconducting Magnet Prototypes

Report Liquid Hydrogen Target for the COMPASS Experiment

Central Solenoid Winding Pack Design

Hydraulic modeling assessment Copyright 2010, Optimized Technical Solutions, LLC

Physics of fusion power. Lecture 14: Anomalous transport / ITER

Electromagnetic Induction and Faraday s Law

Dynamic Characteristics of Double-Pipe Heat Exchangers

Advanced modeling of automotive variable displacement vane oil pumps

Oscillating Flow Characteristics of a Regenerator under Low Temperature Conditions

Design and preliminary results of a prototype HTS SMES device

A Model for Parametric Analysis of Pulse Tube Losses in Pulse Tube Refrigerators

Derivation of dynamo current drive in a closed current volume and stable current sustainment in the HIT SI experiment

Performance test of electromagnetic pump on heavy liquid metal in PREKY-I facility

Analytical and Experimental Studies on the Hybrid Fault Current Limiter Employing Asymmetric Non-Inductive Coil and Fast Switch

Chapter 31 Electromagnetic Oscillations and Alternating Current LC Oscillations, Qualitatively

To be published in the Proceedings of ICEC-22, Seoul Korea, July 2008 MICE Note 232 1

MELCOR Analysis of Helium/Water/Air Ingress into ITER Cryostat and Vacuum Vessel

9th European LS-DYNA Conference 2013

VVER-1000 Reflooding Scenario Simulation with MELCOR Code in Comparison with MELCOR Simulation


Equipartition of Current in Parallel Conductors on Cooling Through the Superconducting Transition

NUMERICAL INVESTIGATION OF THERMOCAPILLARY INDUCED MOTION OF A LIQUID SLUG IN A CAPILLARY TUBE

Transcription:

SIULATION OF THERAL-HYDRAULIC TRANSIENTS IN TWO-CHANNEL CICC WITH SELF- CONSISTENT BOUNDARY CONDITIONS L. Savoldi, * L. Bottura, + and R. Zanino * * Politecnico, Dipartimento di Energetica, Torino, I-10129, Italy + CERN, Division LHC, Geneva, CH-1211, Switzerland ABSTRACT The use of boundary conditions at the conductor ends, taken from the experiment, has recently allowed an accurate thermal-hydraulic simulation of both quench 1 and heat slug 2,3 transients in the two channel cable-in-conduit conductors (CICC), using the 2-fluid ITHRANDIR code. However, in order to be used as a design tool, i.e., to achieve a predictive capability, the code should be independent as much as possible of input from the experiment. Therefore it is necessary to couple ITHRANDIR to a hydraulic network simulator such as FLOWER, providing a self-consistent description of thermal-hydraulic transients in a cryogenic plant. We show here how the coupling is achieved and demonstrate the reliability of the coupled codes against quench and heat slug propagation runs from the QUELL experiment in the SULTAN facility at Villigen PSI, Switzerland. The results show good agreement with experimental data and with simulations performed using experimental boundary conditions. Different levels of detail in the modeling of the hydraulic network are investigated for different types of thermal-hydraulic transient. INTRODUCTION The 2-fluid ITHRANDIR code was developed specifically to simulate thermalhydraulic transients in super-conducting cables with a two-channel topology, and was validated against quench 1 and heat slug propagation 2,3 in the QUELL experiment, assuming a given (experimental) pressure at the inlet and outlet of the conductor sample. Two-channel cable-in-conduit conductors have now been chosen for the Toroidal Field odel Coil (TFC) and the Central Solenoid odel Coil (CSC), in the frame of the International Thermonuclear Experimental Reactor (ITER) project, and the ITHRANDIR code will be used in the assessment of the test program of the TFC. Therefore, it becomes

critical that the code can be used in a predictive mode, as opposed to interpretative simulations. This condition can be satisfied by numerically modeling the entire hydraulic circuit, provided its parameters are known, in order to compute self-consistent pressure p in and temperature T in at the sample inlet, and outlet pressure p out a typical set of boundary conditions. Here we shall model the super-conducting cable (i.e., the sample) using the ITHRANDIR code, and the rest of the cryogenic circuit using a specific hydraulic network solver, i.e., FLOWER. FLOWER has been developed specifically to supply self-consistent boundary conditions to the 1-fluid GANDALF code. The coupling of the two modules was recently validated against quench initiation and propagation in the QUELL experiment. Here we couple FLOWER to ITHRANDIR, and compare the simulations with experimental results of quench initiation and propagation, and of heat slug propagation, in QUELL. ITHRANDIR-FLOWER COUPLING A cryogenic system for a super-conducting coil cooled by forced-flow of supercritical helium can be simulated by FLOWER after identifying the principal components of the circuit. These components are divided into two main categories: junctions (i.e., pipes, pumps or compressors, heat exchangers, valves) and volumes (i.e., reservoirs or manifolds). They are modeled in the code by means of a restricted set of parameters, e.g., cross section, length, hydraulic diameter and friction factor, for the pipes, or volume V, temperature T and pressure p, for the reservoirs, see Bottura and Rosso, arinucci and Bottura and references therein for details. All the different elements must then be connected in a loop, closed by the super-conducting sample. The coupling between ITHRANDIR and FLOWER is achieved through an explicit staggered time integration of the hydraulic network and the cable. At each time step ITHRANDIR provides inlet and outlet mass and energy flux, as input to FLOWER. The latter uses the flux values to compute pressure and temperature in all the junctions and volumes. It thus can feed back ITHRANDIR with p in, T in, p out in a self-consistent way. No iteration is performed because ITHRANDIR uses the boundary conditions computed by FLOWER in the previous time step. THERAL-HYDRAULIC TRANSIENTS IN QUELL Description of the Cryogenic Circuit In Fig.1 a simplified sketch is shown of the cryogenic circuit of the SULTAN facility supplying helium to the QUELL sample. Pressurized helium flows from the cold-box (a two-phase component) through a valve-box that provides plant regulation, and then through the cryostat, i.e., a liquid bath heat exchanger. The supercritical helium flow from the cryostat outlet is split between sample and sample terminals plus current leads. Note that a significant fraction of the helium flow is needed in the refrigeration of the terminals and current leads (~0 % in most cases). A control valve CV and a heater are used to manage the flow and inlet temperature in the sample. The helium flows from the sample and the parallel path back to the cryostat, through two Joule-Thomson valves (JTV), and from there to the cold-box. If a strong increase of the inlet and outlet pressure takes place (e.g., in the case of quench of the sample), the fluid can vent into a reservoir through two relief valves (RV). Unless otherwise mentioned, all circuit data are obtained from Bruzzone and arinucci.

COLD-BOX Reservoir VALVE-BOX JTV JTV CRYOSTAT p=1.3bar T=.2K CV Ohmic heater Sample terminals Current lead terminals SAPLE RV Heater Gas reservoir p=1.2bar, T=300K RV Figure 1. Simplified sketch of the cryogenic circuit of the SULTAN facility for the QUELL experiment. odel of the Cryogenic Circuit for Quench Studies In order to decide which components of the circuit are to be considered in quench simulations, we can observe that in quench studies p in and p out are expected to be driven mostly by quench evolution inside the sample (because of the strong heating induced flow), while the cryogenic circuit is less important. Furthermore, the time scale O(1-10s) of the circuit response to an external perturbation is comparable or longer than the time scale O(1s) of quench propagation. Therefore, even a relatively simple cryogenic circuit model can lead to acceptable results in quench simulations. For this reason we use here a very simplified circuit model, shown in Fig.2a. The choice of components is the same as presented by arinucci et al., but their quantitative characterization is different. Two manifolds in and out are located at the inlet and outlet of the sample, respectively. in and out are considered here to account for the physical helium volume contained in the pipes connecting the sample to the cryostat. The two manifolds are linked by a fictitious compressor that gives the needed pressure head. The compressor emulates the cold-box and the pipes linking the latter with the cryostat. The cryostat is assumed to provide only a localized pressure drop, and it is "hidden" in that part of the circuit modeled as a compressor. The parallel path through the sample terminals and current lead terminals is neglected in this model by assuming that the compressor operates with ~0% of the helium volume actually flowing through the cold-box. The relief valves are assumed to open at an absolute pressure of 10.bar.

J1 COPRESSOR CRYOSTAT in COPRESSOR SAPLE out CV J JTV JTV RV1 RV2 J2 J3 RESERVOIR in SAPLE out RV1 RESERVOIR RV2 (a) (b) Figure 2. Two models of increasing complexity for the circuit in Fig.1. (a) The active component (compressor) acts directly on the sample. (b) Tubes (J1-J3), JTV's, "cryostat" and CV are interposed between the sample and the compressor; a simple model (J) of the parallel path is also included. Fictitious manifolds are included to link different junctions. The compressor is defined by its characteristic in the (G,p) plane, where G is the mass flow rate and p is the pressure head, which is determined by two parameters. Since we have only one (G,p) experimental point, i.e., the operation condition at the beginning of the quench experiment, the second parameter has been chosen to give a qualitatively good global agreement with the experimental results. Notice that this is not an "ad hoc" recipe because, on the quench time scale, the helium pressure in in and out, influenced somehow by the compressor characteristic, is much more strongly influenced by the correct definition of the helium volume contained in the two manifolds. Notice finally that in an earlier publication only the part of the circuit up to the cryostat was considered, with smaller in and out, and less fluid flowing in the compressor. This results in a significant underestimation (more than a factor of 20) for the helium volume inside the circuit, compared to the present case. Analysis of a Quench Run We consider a "standard" quench (Run #2) 1 of QUELL. The QUELL input for the ITHRANDIR code (both conductor geometry and material properties) is the revised one used in earlier studies 2,3. The external heating is supplied by a resistive heater wound directly around the jacket. The results of the simulation are presented in Fig.3. Figure 3a shows a very good agreement between the experimental and the computed total voltage drop. In Fig.3b the experimental quench front propagation, as deduced by the switching on of the voltage signal at the different voltage taps, is also very well reproduced by the simulations both with FLOWER and with experimental boundary conditions. The pressures p in and p out (Fig.3c and 3d, respectively) are somewhat underestimated by FLOWER (relative standard deviation of p in, p out %). Still, since the experimental pressure drop along the sample is well reproduced by the simulation (not shown), the computed quench evolution is in good agreement with the experiment. The pressure underestimation is partly due to an overestimation of the volume of helium available for the sample refrigeration. Indeed, if only a part of the cryogenic circuit is taken into account, p in and p out increase too quickly (not shown), leading to 12%, because the volume of helium to be pressurized in the cryogenic circuit is too small. The sensitivity of the results to the calibration of the compressor characteristic is small.

Total resistive voltage (V) 3 2. 2 1. 1 0. 0 (a) 0. 0 2 3 2 (b) 1 30 0 0 0 Length along conductor (m) 11 10 11 10 p in 9 p out 9 (c) 0 2 (d) 0 2 Figure 3. QUELL Quench #2 1 : experimental data (solid,*), results computed with FLOWER boundary conditions using the circuit model in Fig.2a (dot dashed), results computed with experimental boundary conditions (dashed). (a) Total resistive voltage as a function of time. (b) Quench front propagation along the conductor as a function of time. (c,d) Pressure evolution at the sample inlet and outlet, respectively. In the experiment the opening of the relief valve leads to a collapse of the inlet pressure This is not observed in the simulation because of the slower increase in the computed p in. Analysis of an Inductive Heat Slug Run If we perform simulations of heat slug propagation (zero current and field) with the circuit model in Fig.2a, we obtain different degrees of accuracy in the results depending on the amount of energy deposited and on the external heating duration. In an inductively heated case (Run #00 2,3, linear input power Q0=312W/m supplied on a length L H =0.12m), a reasonable agreement is found between computed results and experimental data, see Fig.. The computed jacket temperature evolution at different sensors along the conductor (Fig.a) is shown to be as accurate as that with experimental boundary conditions. The characteristic of the compressor in the (G,p) plane has been changed with respect to the quench run, emulating the operation of CV and JTV in the real circuit, in order to provide the correct G in at steady state (see Fig.b). This explains the smaller phase shift at the temperature sensors (Fig.a) with respect to the results obtained with experimental boundary conditions, which give an overestimation of G in. The computed p in and p out (Fig.c and d, respectively) show a qualitatively different behavior with respect to the experiment. In the simulation, the pressure tends to stabilize around a value higher than the initial one because the circuit, that can be thought here as a 0-D object,

reacts to the energy supply, pressurizing. In the experiment, the cryostat possibly absorbs the energy input as latent heat of condensation/evaporation, and the pressure, after a few oscillations, tends to return to its initial value. The accuracy in the results, notwithstanding the relatively simple circuit model, is mainly due to the fact that the inductive heater acts on a short time scale (10ms). Indeed on this time scale the perturbation of the hydraulic circuit conditions is very small (i.e., the variation of p in and p out is < 0.bar, see Fig.c and d). odel of the Cryogenic Circuit for Resistive Heat Slug Studies In a resistively heated case (Run #012 2,3, Q0=230W/m, L H =2.3m), the circuit model in Fig.2a gives a significant disagreement with the experiment (not shown). The external heating, which effectively acts on a much longer time scale (~10s) than the inductive one, leads here to significant changes in pressure and mass flow (see below). Furthermore, in the second phase of the transient the circuit response to the perturbation becomes the driving force of the transient evolution. A more accurate circuit model is thus needed in order to get a realistic response of the cryogenic circuit to the perturbation caused by the sample. Notice that the heat slug conditions in QUELL were rather different from those expected in the TFC 2,3. A more detailed circuit model is shown in Fig.2b. The cryostat is implemented as a onephase reservoir (V=O(m 3 ), i.e., much larger than the real two-phase volume). Provided V is sufficiently large, the helium temperature and pressure in the reservoir will not change significantly from the initial values, behaving as in the cryostat. Differently from the previous model, the parallel path is included and pipes, CV and JTV are present here.. (a) T jk (K).. 0 10 20 30 0 0 0 (b). (c). (d) G in (g/s) 2 p In. p Out. 0 0 20 0 0 0 20 0 0 0 20 0 0 Figure. QUELL inductive heat slug #00 2,3 : experimental data (solid, open circles), results computed with FLOWER boundary conditions using the circuit model in Fig.2a (dot dashed), results computed with experimental boundary conditions (dashed). (a) Jacket temperature at the sensors TA, TA, TA, respectively. (b) Sample inlet mass flow rate as a function of time. (c,d) Pressure evolution at the sample inlet and outlet, respectively.

The compressor now takes into account all the helium flowing through the cold-box. The JTV's (implemented as valves with a high localized pressure drop coefficient) regulate the helium access to the cryostat. The CV allows, together with the calibration of the compressor characteristic, a fine regulation of G in. For the parallel path J no heat exchange (see Fig.1) is taken into account, but the higher hydraulic resistance, due to the helium heating and to the path tortuousness, is emulated by a high friction factor. Since J is approximately a factor of five longer than the other tubes, and has a higher pressure drop, it is worthwhile to simulate it with compressible helium flow, because its hydraulic evolution is expected to strongly affect the sample. Pipes J1, J2 and J3 are defined by their physical parameters. The compressor calibration is now expected to have an even smaller influence on the transient evolution, at least because of the presence of the parallel path J in the circuit model. Analysis of a Resistive Heat Slug Run The results obtained for Run #012 with the circuit model in Fig.2b are shown in Fig.. The difference between the peak jacket temperature computed with FLOWER, and the experimental ones, is < 0.K, while the phase shift is < s (Fig.a). The computed G in (Fig.b) decreases faster than the experimental one in the first part of the transient. This effect can be partly attributed to some kind of delay in the response of the two-phase components (not implemented in FLOWER at present), due to condensation/evaporation of 10 (a) 9 T jk (K) 0 10 20 30 0 0 0 G in (g/s) 3 2 (b) 0 20 0 0 p in.... (c) 0 20 0 0 p out.... (d) 0 20 0 0 Figure. QUELL resistive heat slug #012 2,3 : experimental data (solid, open circles), results computed with FLOWER boundary conditions using the circuit model in Fig.2b (dot dashed), results computed with experimental boundary conditions (dashed). (a) Jacket temperature at the sensors TA, TA, TA, respectively. (b) Sample inlet mass flow rate as a function of time. (c,d) Pressure evolution at the sample inlet and outlet, respectively.

helium. After the first decrease, the computed G in monotonically increases till the end of the transient, while both the experimental signal, and the evolution computed with experimental boundary conditions give a non-monotonic behavior, linked to the experimental pressure drop evolution (not shown). The boundary pressures provided in this case by FLOWER are again only qualitatively in agreement with the experimental ones (Fig.c and d), which behave similarly to the inductive run. After a first increase, p in and p out decrease to their initial value because the supplied energy can now be absorbed by other components of the circuit (as opposed to what occurs with the circuit in Fig.2a, where p in and p out asymptotically increase, not shown). However, the decrease is slower than in the experiment, possibly due again to the absence of two-phase components in the model. The circuit model in Fig.2b has also been used (not shown) for the analysis of the quench run considered in the previous section, giving comparably good results. CONCLUSIONS A hydraulic network solver, FLOWER, has been coupled to the two-fluid ITHRANDIR code. The cryogenic circuit of the QUELL experiment has been modeled with different levels of detail in order to simulate different kinds of transient. For fast heating transients (i.e., quench or inductive slugs), even a simple model of the circuit leads to reliable results in good agreement with the experiment, albeit for different reasons, provided a realistic estimation of the total helium volume in the circuit is given. For slow heating transients (resistive slugs), where the effective heating time scale is comparable to the circuit response time scale, a more accurate model of the circuit is needed (larger number of components, and suitable fluid equations, i.e., compressible flow) to obtain acceptable results. ACKNOWLEDGEENTS The work at POLITO has been supported by the EURATO Fusion Technology Program, under contract to R.Z.. The authors would like to thank C.arinucci and P.Bruzzone of CRPP, Villigen, for providing information and data on the SULTAN facility. REFERENCES 1. R.Zanino, L.Bottura and C.arinucci, Computer simulation of quench propagation in QUELL, Adv. Cryo. Eng. 3:11 (199). 2. R.Zanino and C.arinucci, Heat slug propagation in QUELL. Part I: experimental setup and 1-fluid GANDALF analysis, to appear in Cryogenics (1999). 3. R.Zanino and C.arinucci, Heat slug propagation in QUELL. Part II: 2-fluid ITHRANDIR analysis, to appear in Cryogenics (1999).. R.Zanino, S.DePalo and L.Bottura, A two-fluid code for the thermohydraulic transient analysis of CICC superconducting magnets, J.Fus. Energy 1:2 (199).. L.Bottura and C.Rosso, Hydraulic network simulator model, Internal Cryosoft Note, CRYO/9/00 (199).. A.Anghelo, et al., The QUench Experiment on Long Length QUELL - Final Report, EPFL - CRPP, JAERI, IT-PFC and SINTEZ-NIIEFA Report (199).. C.arinucci and L.Bottura, The hydraulic solver Flower and its validation against the QUELL experiment in SULTAN, to appear in IEEE Trans. Appl. Supercond. (1999).. P.Bruzzone, C.arinucci, private communication (1999).