SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL Lasheila Hayes Phone:

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALPHAGAGE th Avenue Rockford, IL James Hoard Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. GREENSLADE & CO., INC Wenneca Avenue Fort Worth, TX Larry Borowski Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ALLOMETRICS, INC Bayport Blvd. Seabrook, TX Terry Baldwin Phone: CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

ACCREDITED LABORATORY. INSPECTION MEASUREMENT COMPANY Wyoming, MI

Certificate of Accreditation

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation to ISO/IEC 17025:2005

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

CERTIFICATE OF ACCREDITATION

Scope of Accreditation For ISOLAB Inc. Calibration

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

For the National Voluntary Laboratory Accreditation Program

CERTIFICATE OF ACCREDITATION

Document No: TR 12 Issue No: 1

CALIBRATION CERTIFICATE # 503

For the National Voluntary Laboratory Accreditation Program

For the National Voluntary Laboratory Accreditation Program

Perry Johnson Laboratory Accreditation, Inc. Calibration Scopes of Accreditation

A2LA. G118: Guidance for Defining the Scope of Accreditation for Calibration Laboratories

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

R SANAS Page 1 of 7

台灣黑馬牌校正器類 CALIBRATOR METROLOGY

SCOPE OF ACCREDITATION

ACCREDITED CALIBRATION AND MEASUREMENT CAPABILITY SCOPE. Ring gaugeф(50~100)mm U=1.1 μm

SAMPLE. Accuracy Calibration Certificate. Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC ISO17025 WI v.1.0

Mason Technology Ltd

Mason Technology Ltd

National Voluntary Laboratory Accreditation Program

Calibration Traceability Guidelines

Maha Ireland Ltd. 629 Jordanstown Avenue, Greenogue Business Park, Rathcoole, Co. Dublin. Calibration Laboratory Registration number: 287C

Trimos LABCONCEPT Universal Length Measuring Instrument

Ackred. nr 1678 Kalibrering ISO/IEC 17025

P103d Annex: Policy on Estimating Measurement Uncertainty for Construction Materials & Geotechnical Testing Labs Date of Issue 09/13/05

MEASUREMENT TRACEABILITY AND ERRORS RELATED TO FORCE MEASUREMENT

COMMON MISTAKES IN DIMENSIONAL CALIBRATION METHODS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012

Extending Transducer Calibration Range by Extrapolation

CERTIFICATE OF CALIBRATION

Experiment P26: Rotational Inertia (Smart Pulley)

Height Master Page 343. Check Master Page 347. Calibration Tools Page 352

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

TR CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF DIMENSIONAL METROLOGY

SAMM POLICY 5 (SP5) POLICY ON MEASUREMENT UNCERTAINTY REQUIREMENTS FOR SAMM TESTING LABORATORIES Issue 2, 28 February 2007 (Amd. 1, 11 August 2014)

1 Measure various dimensions of component using Vernier caliper and dial type vernier caliper. d 3 d 1

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Interlaboratory Comparison & Proficiency Testing Program

Fluid Power Institute Summary Report. Burst Pressure Evaluation Project #52224

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:

The Program. Wear measurement Page 5. Inspection of parts Page 6. Online certificate Page 7. DKD-calibration Page 8. Deviation analysis Page 11

Interlaboratory Comparison & Proficiency Testing Program

Analytical Measurement Uncertainty

6. The default plot created by Excel meets all of the requirements for a formal report plot in ME 360.

WGFF Guidelines for CMC Uncertainty and Calibration Report Uncertainty

Engineering Metrology and Instrumentation

DHANALAKSHMI COLLEGE OF ENGINEERING. (Dr.VPR Nagar, Manimangalam, Tambaram) Chennai

CHAPTER 15. Introductory Engineering Design 179

CERTIFICATE OF CALIBRATION

Experiment 11: Rotational Inertia of Disk and Ring

Transcription:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL 35096 Lasheila Hayes Phone: 205 505 0296 CALIBRATION Valid to: April 30, 2019 Certificate Number: 1592.04 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1 : I. Dimensional Thread Plug Pitch Diameter (6 to 36) mm 2.5 µm Labmaster, thread wires, & gage blocks Pin & Plug Gages Up to 25 mm 0.76 µm High accuracy micrometer Up to 100 mm 0.32 µm + 0.016 µm/mm Labmaster Rings (Inside Diameter) (6 to 120) mm 1.0 µm + 0.014 µm/mm Labmaster, gage blocks, & master ring Digital Protractors (0 to 90) 0.053 Sine bar and gauge blocks Calipers 3 Up to 300 mm (>300 to 1525) mm 1.5 µm + 0.034 µm/mm 15 µm + 0.0087 µm/mm Gage blocks (A2LA Cert. No. 1592.04) Revised 02/14/2019 Page 1 of 4

Depth Gage 3 Up to 300 mm 11 µm Gage blocks Depth Micrometers 3 Up to 300 mm 12 µm Gage blocks OD Micrometers 3 R = 0.001 mm Up to 250 mm Up to 250 mm 1.1 µm + 0.011 µm/mm 6.8 µm + 0.00058 µm/mm Gage blocks Height Gages 3 Up to 1016 mm 33 µm + 0.003 µm/mm Gage blocks Indicators (Dial, Digital, & Test) 3 R = 0.001 mm Up to 51 mm Up to 51 mm 3.2 µm 12 µm Indicator calibrator II. Electrical DC/Low Frequency Electrical Simulation of Thermocouple Indicating Devices Generate 3 R = 0.1 C R = 1 C (-200 to 0) C (0 to 1370) C (-200 to 0) C (0 to 1370) C 1.4 C 1.0 C 1.7 C 1.3 C Fluke 724 temperature calibrator w/ Type K thermocouple R = 0.1 F (-328 to 32) F (32 to 2498) F 2.6 F 1.8 F (A2LA Cert. No. 1592.04) Revised 02/14/2019 Page 2 of 4

Electrical Simulation of Thermocouple Indicating Devices Generate 3 (cont) R = 1 F (-328 to 32) F (32 to 2498) F 2.7 F 1.9 F Fluke 724 temperature calibrator w/ Type K thermocouple III. Fluid Quantities Viscosity Dip Cups Ford Std Cup #4 Ford Std Cup #5 (100 to 1000) mm 2 /s (100 to 1000) mm 2 /s 4.7 % of rdg 5.2 % of rdg Standard oils, thermometer, & stopwatch IV. Mechanical Scales 3 R = 0.01 lb R = 0.1 lb R = 1 lb 0.003 % rdg + 0.0081 lb 0.00042 % rdg + 0.082 lb 0.82 lb Handbook 44 w/ Class 6 weights Balances 3 R = 0.0001 g R = 0.001 g R = 0.01 g R = 0.1 g R = 1 g Up to 200 g Up to 500 g Up to 1 kg Up to 2 kg Up to 6 kg 0.012 mg + 0.0024 mg/g 1.2 mg + 0.0012 mg/g 8.7 mg 82 mg 1.2 g Handbook 44 w/ Class 1 weights Force Gauges 3 R = 1 lb Up to 150 lbf 0.66 lbf Class 6 weights and hanger tension only (A2LA Cert. No. 1592.04) Revised 02/14/2019 Page 3 of 4

Torque Analyzers 3 R = 0.01 Nm (1.4 to 200) Nm 0.28 N m Arm & weights Gage Pressure 3 Transducers & Pressure Gauges R = 0.5 psig (0 to 100) psig 0.32 psig Fluke 718 Torque Wrenches & Drivers Click Type (0.45 to 5.65) N m (3.39 to 45.2) N m (9 to 113) N m (27 to 339) N m (136 to 420) N m 0.034 N m 0.18 N m 0.43 N m 1.6 N m 1.8 N m CDI manual torque system Dial Type (0.45 to 5.65) N m (3.39 to 45.2) N m (9 to 113) N m (27 to 339) N m (136 to 420) N m 0.043 N m 0.25 N m 0.43 N m 1.4 N m 1.7 N m V. Time and Frequency Stopwatch (1 to 180) min 0.20 s WWV Telephone Time Service 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer s device and to influences from the circumstances of the specific calibration. 3 In the statement of the CMC, R refers to the resolution of the unit under test. (A2LA Cert. No. 1592.04) Revised 02/14/2019 Page 4 of 4

Accredited Laboratory A2LA has accredited ADVANCED TECHNOLOGY SERVICES - HMA Lincoln, AL for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 25 th day of July 2017. President and CEO For the Accreditation Council Certificate Number 1592.04 Valid to April 30, 2019 Revised on February 14, 2019 For the calibrations to which this accreditation applies, please refer to the laboratory s Calibration Scope of Accreditation.