high performance OPTIC 3 and applications a total analytical solution

Similar documents
Analytical Instrumentation

The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Application Note No Introduction. DMI Instrumentation. DMI Method. DMI for Lettuce and Pea Extracts. Lettuce results

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

Chemistry Instrumental Analysis Lecture 27. Chem 4631

DI 3500 Discrete Aoalvzer

ChromTech options for PAL systems

LCTech GmbH Chromatographie

Thermo Scientific TriPlus RSH Autosampler Integrated Sampling System. You are productive solving your chromatography challenges

COMBI. Gaschromatography. GC / GC-MS sample injector grows with your needs

Determination of Pesticides in Aqueous Samples by On-Line Coupling Solid-Phase Extraction to Gas Chromatography with At-Column Concentrating Interface

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Application. Gas Chromatography February Introduction

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Determination of Volatile Substances Proof of Food Adulteration

IRMS. perspective. Isotope Ratio Mass Spectrometry.

PAL SPME Arrow The Better SPME

PAL SPME Arrow The Better SPME

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Rapid Catalyst Screening Reactors

Petrochemical. Transformer Oil Gas Analysis - TOGA

TOXICOLOGY & FORENSIC APPLICATIONS

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

ICP-MS. High Resolution ICP-MS.

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Perseverance. Experimentation. Knowledge.

SIFT-MS. technology overview

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

U.S. EPA Method 8270 for multicomponent analyte determination

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Sample Preparation. Approaches to Automation for SPE

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

HYPHENATED TECHNOLOGY GUIDE

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

SOPHISTICATED DESIGN, INTUITIVE OPERATION, RESEARCH-GRADE RESULTS

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Maximizing Sample Throughput In Purge And Trap Analysis

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Gas Chromatography (GC)

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

University Wet Chemistry Analyzer Packages

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Focus Series Peptide Synthesizers

Development of Portable GC/MS System with Benchtop Performance for Critical DoD Applications. Mitch Wells, Ph.D. Philip Tackett, Ph.D.

GAS CHROMATOGRAPHY (GC)

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

C146-E209. Headspace Samplers. HS-20 Series

Ideal and powerful solution

PERSPECTIVE STABLE ISOTOPE RATIO MS

Thermo Scientific TriPlus RSH Autosampler Integrated Sampling System. you are productive. solving your chromatography challenges

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa

ION CHROMATOGRAPHY SYSTEM S 150

MultiVap8: Automated concentration system

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Series 2. Continuous monitoring of trace chemical vapours

Determination of volatiles in Food sample preparation strategies and techniques Dr Kathy Ridgway

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

GC/MS Application Note

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

Chemical Analysis Problem

A SCENT OF FUTURE. DANI Instruments Solutions

Centri. A breakthrough in sample automation and concentration for GC MS

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Automated Clinical Analyzer

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples

Thermo Scientific GasBench II

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Freezing point osmometry

Dynatherm Thermal Desorption Systems

HYPHENATED TECHNOLOGY GUIDE

Introduction to Capillary GC

Agilent G3212 GC-APCI Source

110 Lowell Rd Hudson, NH USA Tel:

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Food analysis. Solutions for Your Analytical Business Markets and Applications Programs

Introducing 7820A GC System. Reliability, Simplicity & Affordability!

GC Application Note. Dilution/standard addition: Efficient and traceable.

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

METHOD 3600C CLEANUP

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

SELECTED ION FLOW TUBE MASS SPECTROMETRY. Interscience Expert Center: VIP Meeting 15 Sept. 2009

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Transcription:

high performance OPTIC 3 and applications a total analytical solution

Excellent by nature Excellent effectivity, efficient performance and great flexibility. OPTIC 3: a fully programmable injector for gas chromatography. Designed for a range of injection modes to be selected and optimised to suit sample characteristics thus adding to the capabilities of the laboratory. The OPTIC 3 is the result of years of innovations in GC injection. It incorporates all facilities to control additional flow and pressure parameters for sample introduction. Such flexibility enables analytical strategies to be reappraised to raise analytical standards by optimising the sample introduction process. The specially designed software offers a user-friendly solution for every analytical need. Because sample preparation time is significantly reduced, operational costs are too. By saving 30 minutes in the preparation stage an investment in the OPTIC 3 can be returned in a few hundred injections. As a high performance injector, the OPTIC 3 is the perfect interface between sample and analytical column. The optional available Cryo Trap widens the range of applications. Three generations of ATAS GL experienced technologie. The OPTIC 3: Handles the widest range of applications Has unmatched flexibility for choice of injections Programmed temperature and flow control Easily installed on all common GCs (different GCs, same performance) Designed for full automation Offers a complete software-controlled efficient and effective performance Increasing the capacity of GC systems with the high performance OPTIC 3 injector: One injector for different GC properties Uncompromised analyses Optimised sample introduction Maximised chromatography efficiency Enables standardisation on a single system Assists analysts by bringing conformity in operation Standard operation procedures are simpler to write Operational support over the internet a total analytical solution

Intelligent by nature The OPTIC 3 has been developed for integration into automatic GCs for 24/7 operation. This innovative system offers no less than 7 programming modes adding versatility to any GC. The crucial sample introduction never needs to be compromised, allowing sensitive or complex mixtures to be handled with confidence. Techniques such as thermal desorption, large volume and off-line sampling can be applied as easily as the traditional on-column, split and splitless injection methods. 7 Injection modes: Split Splitless DTD DMI RLVI At-Column (large volume injection) Expert mode Software control The newly designed, highly innovative software expands the dimensions of injection technology. Based on years of experience and development it extends features and optimises the analytical output. Therefore, the EVOLUTION WORKSTATION offers state of the art GC analysis in a very userfriendly way. Integrated Internet technology secures support and software updates at any time at any location. RS 232 interface and LAN connection Windows 98/2000/NT compatible Complete status information at any moment during standby or method run Log file Easy method definition and method development Offers method parameter optimisation sequence Built-in AT Column calculator for most used solvents Thermocouple located inside GC for real constant flow control Real time data collection for temperature and flow on screen Nature s finest The Maas and the Rhine are two of the major rivers that cross the Netherlands and have shaped the contours of the country and determined its natural habitat. So it is not surprising that the Kingfisher feels at home in this delta. An environment in which this brightly coloured bird fishes out exactly what it is looking for, with incredible precision...

Versatile bynature Cryo Trap Optionally available with the OPTIC 3 is the integrated Cryo Trap, using cold N 2 gas. Cryo Trap boosts in a very safe way speed, cost effectiveness and flexibility of the analytical process. Especially for low volatiles components. Operating using cold N 2 gas Temperature range -150 C to 400 C Heating ramp up to 15 C / sec Fast cooling Integrated within the OPTIC 3 (and as a stand alone application for the OPTIC 2 and others) Fast splitless transfer Compatible with any GC FOCUS Cryo Trap ATAS GL. FOCUS is a highly versatile system, designed to process samples for routine GC and GC mass spectrometry analyses. Sample preparation procedures, including liquid-liquid extraction and derivation, can be selected, programmed and fully automated to meet specific analytical requirements. Located above the GC, the robotic sample processor requires no additional bench space. It is based on a robotic XYZ arm with motorised syringe and compromises separate vial trays for samples and solvents/reagents. LVI syringe wash station, a heatable sample agitator for mixing, headspace and SPME. Simple and reproducable application robot. FOCUS facilities Liquid sampling Solvent, reagent and standard additions Derivatisation Liquid-liquid solvent extraction that can be combined with Rapid Large Volume Injection (RLVI) Large volume injection, combined and operated as appropriate Automated extraction of relatively small sample volumes possible while retaining trace detection limits Difficult Matrix Introduction (DMI) DTD Sample tube/liner exchange

Sensitive by nature Solid Samples: DTD Direct Thermal Desorption (DTD) which thermally desorbs samples directly onto the head of the capillary column for GC analysis is widely used in the collection and injection of samples. DTD can be employed to determine compounds in gases, air, liquids or even solid samples. Thus, analyses are transferred very efficiently for high-resolution chromatography and, being a simpler process, it is faster to set up and requires little optimisation. The innovative DTD solution places tubes in the OPTIC 3 injector directly on top of the column. Therefore: No transfer line No cold spots No cold valves Conclusion: no losses in the analytical process The DTD automated Thermal Desorber 98 up to 294 sample tube capacity For active, labile and high MW compounds Solids as well as absorbed samples Compatible with any GCs or GC-MS Flexible Pyrolysis Fully automated injection proces. Applications Preservatives in wood Nicotine in tobacco Car exhausts Spores and poles CTME analysis Characterisation of polymers Pesticides in food Semi-volatile terosoles a total analytical solution

Applications Online Solid Phase Extraction The Online Solid Phase Extraction has been developed for the water industry to measure trace organics in drinking water and environmental samples. In principle, Online SPE can be applied to any analysis that is currently performed by the combination of solid phase extraction (SPE) and GC-MS. As characteristics of the samples in difficult matrices vary, optimisation of methodologies will be necessary using the wide range of operating controls that ATAS GL provides. SPE The OPTIC 3 combined with a capillary GC-MS in combination with SPE results in a powerful online system for 24/7 operation gas chromatography: Clean-up and enrichment of trace organic components Lower levels of detection Contamination-free system Small sample volumes Great reduction of extraction times Reduction of transport and handling costs a solvent monitor the solvent can be vented away and the analysis will start. After closing the split line and heating the injector very low concentrations of the analytes are determined. This technique, in combination with a time-of-flight mass spectrometer is the perfect solution for fast screening of samples for contamination. EPA 8270 The 8270 Injector System has been developed to meet the stringent requirements of US EPA Method 8270 for the analysis of semi-volatiles by GC and GC-MS. The system, which includes all the necessary hardware and software, automates the injection of large volumes of sample extracts into the GC analyser and provides major analytical advantages. With SPE based on large volume injection (RLVI) or AT column, ATAS GL offers the highest sensitivity with a minimised sample volume and a lower amount of solvent used. Therefore, not only the environment but also the financial department will benefit: solvents are as polluting as they are expensive. SPME SPME (Solid Phase Micro Extraction) adds simplicity and speed to the analytical process. The Optic 3 increases precision with a ramp rate of 1000 C/min and a fixed starting point. The result is great improvement of RSD figures. Cold injection temperature and fast heating are the benefits. DMI DMI (Difficult Matrix Injection) places a vial or cup with the liner directly on top of the column. With At-Column large volume injection Large volume injection significantly reduces the high cost of sample preperation. It is estimated at 65%, of the total GC time for the analysis of semivolatiles. Analysis advantages Increasing the sensitivity achieved by the GC or GC-MS Reducing the volume of the original sample Greatly reducing solvent extraction costs Elimination of concentration steps Guaranteed Method 8270 performance Rugged reliable automated performance Reproducible quantitative results Compatible with all GC-MS systems Flexible for methods development Automatic optimisation sequence Intelligent software a total analytical solution

Gas Samples The OPTIC Air Sampling System has been developed for the automated in situ determination of airborne C2-C6 and C5-C10 volatile organic compounds (VOCs) by GC. The system can be readily interfaced to most GCs. The system is rugged and can be transported in a mobile laboratory for on site monitoring of urban and rural environments. As such, OPTIC 3 is the ideal analytical tool for the measurement of organic atmospheric pollutants in environmental studies to improve air quality. The OPTIC Air Sampling System Rapid, high resolution analysis In situ determinations, saving time and consumables Continuous, unattended monitoring Reproducible, quantitative results Compatible with most GCs Enables detection down to ppt levels For further technical specifications, visit our website: www.atasgl.com

Mission Statement Precision and efficiency. Providing easily retrofittable accessories to GC and GC-MS users has always been second nature to us. We enable users to improve the quality of the analytical data they produce and at the same time significantly reduce the cost per analysis. ATAS GL therefore focuses on simplifying and automating analytical procedures to significantly reduce the need for manual processing of any samples. ATAS GL International BV De Run 4441 P.O Box 17 5500 AA Veldhoven The Netherlands Tel.: +31 (0)40 254 95 31 Fax: +31 (0)40 254 97 79 E-mail: info@atasgl.com Internet: www.atasgl.com