PIXE Protocol Setup for Cluster Analysis of Archeological Samples

Similar documents
COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

Práctica de laboratorio número 6: Non-Rutherford scattering near the MeV 12 C(p,p) 12 C resonance

SYSTEM FOR PIXE TRACE ELEMENT ANALYSIS AT MTF. M. Beňo, J. Dobrovodský, D. Vaňa, S. Minárik

On the Direct Characterization and Quantification of Active Ingredients in Commercial Solid Drugs using PIXE, PIGE and ToF-SIMS techniques

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

Ion-beam techniques. Ion beam. Electrostatic Accelerators. Van de Graaff accelerator Pelletron Tandem Van de Graaff

Determination of the activity of radionuclides

Rutherford Backscattering Spectrometry

2.3 Particle Induced X-Ray Emission PIXE

Applications of Nuclear Analytical Techniques in Geoscience

Data report for elemental analysis of IMPROVE samples collected during April, May, June 2009 UC Davis Submitted June 18, 2010 SUMMARY

Quantitative XRF Analysis. algorithms and their practical use

Altitude influence of elemental distribution in grass from Rila mountain. Dr. E. Nikolova, Dr. A. Artinyan, S. Nikolova INRNE - BAS XRF Laboratory

Applications of proton-induced X-ray emission technique in materials and environmental science

Secondary ion mass spectrometry (SIMS)

XUV 773: X-Ray Fluorescence Analysis of Gemstones

Analysis of Cadmium (Cd) in Plastic Using X-ray Fluorescence Spectroscopy

IN THE NAME OF ALLAH, THE MOST MERCIFUL AND COMPASSIONATE

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Available online at ScienceDirect. Energy Procedia 71 (2015 ) Yokohama, Kanagawa, Japan

The scanning microbeam PIXE analysis facility at NIRS

APPLICATION OF THE NUCLEAR REACTION ANALYSIS FOR AGING INVESTIGATIONS

Trace Element Profiling of Gunshot Residues by PIXE and SEM-EDS: A Comparative Study

Within the vast field of atomic physics, collisions of heavy ions with atoms define

Deuteron activation cross section measurements at the NPI cyclotron

Data report for elemental analysis of IMPROVE samples collected during April, May, June 2006 UC Davis - Submitted May 14, 2008 SUMMARY

Megan E. Bennett, Dmitriy A. Mayorov, Kyle D. Chapkin, Marisa C. Alfonso, Tyler A. Werke, and Charles M. Folden III

Secondary Ion Mass Spectrometry (SIMS) Thomas Sky

Scintillation Detector

FUNDAMENTAL PARAMETER METHOD FOR THE LOW ENERGY REGION INCLUDING CASCADE EFFECT AND PHOTOELECTRON EXCITATION

Detection and measurement of gamma-radiation by gammaspectroscopy

Particle-Induced X-Ray Emission Spectrometry (PIXE)

Overview of X-Ray Fluorescence Analysis

Utilization of the RBI Tandem Accelerator Facility for Analytical Applications

Out of vacuum characterisation of surfaces: a possible approach?

Physics 100 PIXE F06

Joint ICTP-IAEA Workshop on Nuclear Data for Analytical Applications October 2013

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

Determination of e/m, mc 2, and the Relations Among Momentum, Velocity, and Energy of Relativistic Electrons

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS

THE USE OF WAVEFORM DIGITIZERS WITH SOLID STATE DETECTORS FOR SPECTROSCOPIC APPLICATIONS. Carly Jean Smith

PHYS 3650L - Modern Physics Laboratory

Spectroscopy on Mars!

THE COMPTON EFFECT Last Revised: January 5, 2007

3.5. Accelerator Mass Spectroscopy -AMS -

PHI 5000 Versaprobe-II Focus X-ray Photo-electron Spectroscopy

APPENDIX TABLES. Table A2. XRF analytical results for samples from drill hole AP5 (Areachap)

Multi Channel Analyzer (MCA) Analyzing a Gamma spectrum

Photoemission Spectroscopy

MS482 Materials Characterization ( 재료분석 ) Lecture Note 4: XRF

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Ion Implanter Cyclotron Apparatus System

Recent Activities on Neutron Calibration Fields at FRS of JAERI

EXPERIMENTS CHARACTERIZING THE X-RAY EMISSION FROM A SOLID-STATE CATHODE USING A HIGH-CURRENT GLOW DISCHARGE

Summary of test results for Daya Bay rock samples. by Patrick Dobson Celia Tiemi Onishi Seiji Nakagawa

Distinguishing fissions of 232 Th, 237 Np and 238 U with beta-delayed gamma rays

FLUORINE IN WATER AND TEETH MEASURED WITH PIGE

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Alpha-Energies of different sources with Multi Channel Analyzer

In-Situ Analysis of Traces, Minor and Major Elements in Rocks and Soils with a Portable XRF Spectrometer*

Efficiency and Attenuation in CdTe Detectors

CALCULATION OF THE DETECTOR-CONTRIBUTION TO ZIRCONIUM PEAKS IN EDXRF SPECTRA OBTAINED WITH A SI-DRIFT DETECTOR

X-RAY SCATTERING AND MOSELEY S LAW. OBJECTIVE: To investigate Moseley s law using X-ray absorption and to observe X- ray scattering.

OES - Optical Emission Spectrometer 2000

Information on the test material EDS-TM002 and the BAM software package EDX Spectrometer Test for determination of the spectrometer performance

PXAMS--Projectile X-ray AMS: X-ray Yields and Applications

Applications for PIXE and other Ion Beam Analysis (IBA)

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

CHARACTERIZATION OF Pu-CONTAINING PARTICLES BY X-RAY MICROFLUORESCENCE

accelerating opportunities

MC simulation of a PGNAA system for on-line cement analysis

Low Energy Nuclear Fusion Reactions in Solids

Measurement of 40 MeV Deuteron Induced Reaction on Fe and Ta for Neutron Emission Spectrum and Activation Cross Section

ED(P)XRF: SCREENING ANALYSIS AND QUANTITATIVE ANALYSIS with POLARIZED

Measurements of Neutron Total and Capture Cross Sections at the TOF spectrometers of the Moscow Meson Factory

Characterization of Secondary Emission Materials for Micro-Channel Plates. S. Jokela, I. Veryovkin, A. Zinovev

Data report for elemental analysis of IMPROVE samples collected during OCTOBER, NOVEMBER, DECEMBER 2005 UC Davis SUMMARY

Materials Analysis Using Fast Ions

Method of active correlations in the experiment 249 Cf+ 48 Ca n

Experimental study of nonlinear laser-beam Thomson scattering

X-Ray Fluorescence and Natural History

Surface analysis techniques

EXPERIMENTAL STUDY OF NEUTRON FIELDS PRODUCED IN PROTON REACTIONS WITH HEAVY TARGETS. Nuclear Physics Institute AS CR, Rez Czech Republic

Time-Resolved μ-xrf and Elemental Mapping of Biological Materials

Measurements of the D + D Reaction in Ti Metal with Incident Energies between 4.7 and 18 kev

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

Elastic Recoil Detection Method using DT Neutrons for Hydrogen Isotope Analysis in Fusion Materials. Abstract

A Comparison between Channel Selections in Heavy Ion Reactions

The accelerators at LNS - INFN and diagnostics aspects of the radioactive beams

Introduction to X-ray Photoelectron Spectroscopy (XPS) XPS which makes use of the photoelectric effect, was developed in the mid-1960

On the Quantification of Atorvastatin and Celecoxib Active Ingredients in Commercial Solid Drugs using the TT-PIXE and TT-PIGE Techniques

4.1 Atomic structure and the periodic table. GCSE Chemistry

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

ECE Semiconductor Device and Material Characterization

ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS

RESEARCH INTO LOW ENERGY NUCLEAR REACTIONS IN CATHODE SAMPLE SOLID WITH PRODUCTION OF EXCESS HEAT, STABLE AND RADIOACTIVE IMPURITY NUCLIDES.

HIRA CSI DETECTOR RESPONSE TO LOW ENERGY PROTONS

Journal of Environmental Research And Development Vol.10 No. 02, October-December 2015

APPENDICES. Appendix 1

Quantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography

Transcription:

PIXE Protocol Setup for Cluster Analysis of Archeological Samples Mohamad Roumié Accelerator Laboratory, Lebanese Atomic Energy Commission, National Council for Scientific Research, Airport Road, P.O.Box: 11-8281, Beirut, Lebanon. * E-mail: mroumie@cnrs.edu.lb Abstract. Ion Beam Analysis techniques were developed and utilized for applications in the domain of archeology at the accelerator laboratory of the Lebanese Atomic Energy Commission. Our first aim was to set up a suitable experimental protocol using Proton Induced X-ray Emission technique, in order to have accurate and relatively fast measurements for the analysis and the study of archeological objects, mainly ceramics. The first experimental protocol was done using two runs at 1 MeV and 3 MeV. It showed satisfactory results when it was applied to Roman amphora from Beirut and helped to establish a database of Beirut amphora production. The second one was more advantageous since it is time consuming by using just one run at 3 MeV with a pinhole filter as x-ray absorber. It had the same ability as the previous one by doing accurate PIXE measurements and showed the similar satisfactory results. Consequently, a classification study based on the elemental composition and on multivariate statistical techniques will be performed in order to determine possible provenance of the studied archeological objects. 1. Introduction Since 1999 a particle accelerator, located at the Lebanese Atomic Energy Commission, has been devoted to elemental analysis in different domains of application: archeology, environment and materials science. Several nuclear analytical techniques are performed, such PIXE, RBS, PIGE, NRA, ERDA and others. Indeed the first application of the setup in archeology concerned the study of Beirut ceramic products. In view of the considerable Lebanese heritage, a special attention was focused on the PIXE applications in archeology, which its capability in the field was proven many times. The opportunity of our work is to establish locally, in Lebanon, a powerful analytical technique that archeologists need sometimes to resolve some problems. In fact, the elemental composition determination provided by PIXE, will be used in a multivariate statistical program to identify and classify into groups the studied objects. It is assumed that objects in the same group have the same provenance. It is known that Particle Induced X-ray Emission is a suitable technique to the study of archeological objects because it is sensitive, multi-elemental, relatively fast and non destructive [1, 2]. Comparing to other analytical techniques that require sample digestion, chemical extraction and some other preparation before analysis, the PIXE advantages are enhanced when a considerable quantity of objects are present. The setup of an experimental protocol capable to do accurate measurements using PIXE technique was necessary to establish in order to provide elemental analysis of archeological objects.

Two experimental setup protocols were established, experimented and will be discussed later in more details through the measurement of different samples. 2. Experimental 2.1. Target preparation The selected ceramics were chosen from pre-groups already established according to archeological-typological criteria. The surface layers of the sherds were removed, as they are more liable to present alterations in their composition due to chemical exchanges with the surrounding soil. Samples were heated for one hour at 950 C, and then left to cool down in the oven. This process was designed to eliminate the organic elements and the humidity, which normally constitute 2-3% of our samples. After crushing into an agate mortar, the collected powder was pressed into pellets with a hydraulic press. The grain size is less than 20 µm, which was far smaller than the beam size (~2 mm), and hence a better homogeneity of the analyzed sample is achieved. A borax powder, from behind and around the edges, was pressed with the ceramic powder in order to improve the adhesion of the obtained pellet and to keep it free of cracks. The obtained dimensions of the pellets were 2-cm in diameter and 1 mm in thickness. In order to avoid a charge build-up at the surface during the analysis, the sample was covered, using an adapted carbon deposition evaporator, by a very thin ultra pure Carbon layer (<10 µg/cm 2 ). 2.2. Experimental Set-up The elemental composition of the archeological ceramics was measured by the conventional in vacuum PIXE, using the accelerator facility at the Lebanese Atomic Energy Commission [3]. It s a tandem Pelletron from NEC of 1.7 MV, model 5SDH, with an Alphatross RF ion source. The spot diameter of the beam on the target was about 2-4 mm, defined by a Ta antiscatter collimator. In the PIXE chamber, the beam hits the target under normal incidence. The PIXE scattering chamber, which contains the X-ray detector, is equipped with a wheel target holder (up to 16 samples) monitored by PC through a stepping motor. X-ray emission from targets is detected using an Ortec Si(Li) detector (SLP-06165 model) with 30 mm² active area, 12.7 µm thick Be window, and 170 ev measured FWHM energy resolution at 5.9 kev, placed at 135 to the beam direction. The Si(Li) detector calibration and the solid angle determination were performed using a set of appropriate radioactive sources and via the analysis of a set of MicroMatter thin film standards. The beam current, on the target, was measured via a 20 cm length graphite faraday cup electrically isolated from the analysis chamber and located in the beam direction at 1 cm behind the target. An Ortec charge integrator, connected to an Ortec digital counter-timer, measured the beam charge deposited on the target. The suppression of secondary electrons, emitted from the target, was realized by holding the target between two appropriate aluminum circular wires biased at 400 Volts. The bias voltage was optimized in order to have less than ± 2 % difference between the current measured directly by the Faraday cup (without sample) and the one measured on the sample.

3. PIXE protocols Two PIXE protocols were used to determine the elemental composition of ceramic samples in order to provide cluster analysis for provenance studies. A comparison between the two protocols was necessary in order to choose the most appropriate one regarding the accuracy and the time of the measurements. As application, the first protocol was used in a first study on Roman amphora from Beirut and showed satisfactory results. It allowed the determination of an elemental composition database of Beirut ceramic product at the Roman period [4]. The second protocol was applied to the provenance study of Byzantine amphora from Beirut and showed also adequate results using the already established database [5]. In fact, the elemental composition of the most abundant elements (10 to 20) was used in multivariate statistical techniques, in particular the cluster analysis. 3.1. Two runs measurement Prior to the analysis of the studied archeological samples, some reference materials such as the two Geo-standards DR-N and BE-N are analyzed by PIXE, as thick targets, as a quality control for our experimental setup. PIXE measurements were carried out in order to determine almost 20 elements. The different prepared samples were exposed to a proton beam at two different energies: (a) 1 MeV, without any x-ray absorber in front of the detector, for matrix determination (Fig.1a), which is constituted by major and minor elements (Na, Mg, Al, Si, K, Ca, Ti, Mn and Fe). Tentative measurements, for V and Cr, were performed as well, but were not further used due to low precision and accuracy. However, the use of more appropriate filters showed a better and acceptable determination for these elements. Consequently, this determination required a third acquisition for the same sample, which is not appropriate for the study of a large number of objects; therefore a compromise between time of analysis, which constitutes a part of the experimental protocol, and necessary elements needed for classification is obtained by the elimination of these two elements. Due to the close distance between the target and the detector, a beam current of 0.4 na and an acquisition time of about 10 minutes were enough for the analysis. The total integrated charge for each sample was 0.2 µc and the count rate did not exceed 500 counts/sec. (b) 3 MeV to determine the heavier elements (Fig.1b) with Z = Z Fe. In the case of ceramics, they are usually the trace elements such as Ni, Cu, Zn, Ga, Rb, Sr, Y, Zr, Ba, Pb and others. An Al filter of 250 µm of thickness was positioned in front of the detector entrance in order to absorb the low energy X-rays emitted by the major elements. To get good statistics within a reasonable time of acquisition (~10 minutes), the beam current was increased to ~100 na. Thus, the total integrated charge was 60 µc and the count rate was found to be less than 1000 counts/sec.

Yield 10000 1000 100 Na Mg Al Si P S K Ca Ti (a) Proton 1 MeV 0.2 mc without x-ray absorber Fek a Fek b 10 Mn 50 100 150 200 250 300 350 Yield 10000 1000 100 Fe ka Fe kb Zn ka Ni Cu Ga Rb Zn kb As Pb L Sr Y Zr ka Zr kb Nb (b) In Protons 3 MeV 60 mc 250 mm Al Filter Ba ka Ba kb 10 200 400 600 800 1000 Channel number Fig. 1: X-ray spectrum of a ceramic object, which shows the major and trace elements at respectively: (a) 1 MeV and (b) 3 MeV of proton beam. Samples were classified into groups of similar elemental composition by hierarchical cluster analysis (Fig. 3). Cluster analysis was applied to standardized data, using Euclidian distance as distance measure and unweighted pair-group centroid as linkage rule. Twelve elements (Mg, Al, Si, K, Ca, Ti, Fe, Ni, Zn, Rb, Sr, Zr) were taken into account in the classification. Some elements were not considered, such as V and Cr, for analytical reasons and also in the case of Ba because its concentration may have been altered during the burial of the sherds. 3.2. One run measurement The second protocol, which was developed later, consisted on the use of one-run PIXE, instead of two, for time consuming in order to analyze a large number of samples in due time. This procedure allowed both the lighter (10< Z< 27) and heavier elements (Z >26) to be analyzed simultaneously. Indeed, the so-called funny filter (a filter with a tiny hole drilled at its center) is an x-ray absorber foil that is placed in front of the Si(Li) detector. This absorber has only a small effect on the less intense higher energy x-rays, but it stops most or all the intense low energy x-rays except for those that pass through the pinhole [6]. The result is a spectrum where both low and high energies X-rays are accumulated. The use of the Al pinhole filter provided 22 elements in one spectrum (Fig. 3): (i) Na, Mg, Al, Si, P, Ca, K, Ti, Mn and Fe as major and minor elements, and (ii) V, Cr, Ni, Cu, Zn, Ga, Rb, Sr, Y, Zr, Nb and Pb as trace elements.

10000 Al Si Ca Fe 3 MeV proton 250 m m Al funny filter 13 m C YK α +RbK β 1000 Mg K TiK α Zr S Zn Sr 100 TiK β +VK α Mn Ni RbK α As+PbL α PbL β Nb 10 VK β +Cr Cu Ga 0 200 400 600 800 1000 Channel Fig. 2: PIXE spectrum of a Byzantine amphora from the Beirut 002 site and corresponding to the second group B. The prepared sample was bombarded with 3 MeV protons and a 250 µm Al funny filter was placed in front of the Si(Li) detector, as X-ray absorber A systematic study was undertaken on reference materials such as IAEA SL-1 and two geostandards BE-N and DR-N, received as powder form and prepared in the same way of our studied samples, in order to choose the most appropriate funny filter (type, thickness and hole diameter) for such study. While it is reasonably straightforward to characterize a normal foil as x-ray absorber, this is not the case for a funny filter. A well calibration of the detection system (filter thickness, hole diameter, Beryllium window thickness, solid angle or geometry) was done in order to have no energy dependence of the so-called H value. It was found that a 250 µm thick Al funny filter with a hole diameter of about 0.3 mm, offered a good detection sensitivity for most of the elements of the reference standards, analyzed as thick targets, such as the IAEA SL-1, and the geo-standards BE-N, and DR-N (Table 1). Furthermore, the fractional hole size, a characteristic parameter which is the ratio between the hole area and the surface of the whole filter seen by the detector, was determined experimentally and found to be equal to 0.295%. This essential determination was realized by analyzing a set of thin film standards (Micromatter reference material) covering x-ray energies from 1.4 kev to 25 kev. For the geostandard reference materials and comparing to the two-acquisitions protocol using 1 MeV and 3 MeV, the certified and measured values showed satisfactory results, within 5 %, for most of the above mentioned elements. In addition, the limits of detection (LOD) were significantly improved for V (106 vs. 448 ppm) and Cr (44 vs. 117 ppm). In contrast, the use of the funny filter caused deterioration of the detection limit for Na, and hence a consequent quantification for such low content was less accurate. Nevertheless, this Na determination was not necessary for the cluster analysis, since the Na determination was just used to complete the elemental composition to 100%.

DRN BE-N DR-N BE-N Majors cv mv cv mv Traces cv mv cv mv Na 2 O 3.05 2.52 3.28 3.36 Ni 15 11 275 277 MgO 4.49 3.84 13.56 11.01 Cu 51 56 74 63 Al 2 O 3 17.89 17.82 10.39 11.59 Zn 148 155 124 113 SiO 2 53.97 54.42 39.41 39.71 Ga 22 20 18 14 P 2 O 5 0.26 0.27 1.08 1.21 Rb 75 75 48 51 K 2 O 1.74 1.7 1.43 1.61 Sr 408 440 1413 1538 CaO 7.20 7.31 14.31 14.91 Y 29 25 31 28 TiO2 1.11 1.15 2.69 2.67 Zr 128 115 273 281 MnO 0.22 0.25 0.21 0.16 Ba 393 472 1057 1053 Fe 2 O 3 9.91 10.5 13.25 13.26 Pb 56 62 4 6 Table 1. Comparison of the certified values cv (after normalized to 100%) and the measured values mv, of major (%) and trace elements (ppm) for DR-N and BE-N standards, using 3 MeV protons and Al funny filter. 3.3. Cluster analysis The PIXE spectra were processed with the Gupix package (Guelph PIXE software package) [7]. This program is based on the fundamental parameter approach including x- ray production cross sections, x-ray attenuation coefficients, proton stopping powers, detector efficiency, collected charge and geometry effects to produce an output of elemental concentrations in ppm. Then, cluster analysis was performed, using a multivariate statistical program, to group together objects that have similar elemental compositions. It used the Gupix data matrix, containing the sample identification as columns and the chemical elements or characteristics as rows. The data was standardized before clustering, with the formula given in Eq. (1) [8], to make all characteristics contribute equally to the discrimination process. Xij X i Zij = (1) S i where Z ij are the elements of the new matrix, X ij the elements of the original data matrix, X i the average of elements per attribute and Si the standard deviation. Indeed, cluster analysis was applied to standardized data, using Euclidean distance defined in Eq. (2) as the distance measure and unweighted pair-group centroid as the linkage rule [9]. The smaller the Euclidean distance based on m chemical elements is, the better the linkage is between two objects j and j', hence the greater the probability for belonging to the same origin [10]. 2 m 2 d ' = ( ) ' j, j Z 1 ij Z (2) ij i=

Figure 3 shows the statistical classification of Roman amphorae from Beirut including local reference materials and carrot amphorae found in Gaul (south of France). Once can see that some of the 'carrot' and Reynolds Type 72 amphorae were of Beirut products, which highlight the role of Beirut city in the Mediterranean trade in the Roman period. Fig.3: Classification of Roman amphorae from Beirut and from Gaul: Beirut reference samples for local production, carrot and Reynolds type 72 amphorae (see symbols chart). The hierarchical cluster analysis was applied to standardized concentrations of 12 elements. The compositional groups are underlined and the reference samples are indicated by black triangles. 4. Conclusion In this paper, we presented the in vacuum PIXE set-up optimized, at the IBA laboratory in Lebanon, for the analysis of archaeological ceramics. The elemental composition of the different archeological samples, analyzed as thick targets, was determined successfully in one run using a 3 MeV proton beam with a 250 µm thick Al funny filter as X-ray absorber. The comparison with the typical experimental protocol of PIXE, using two runs at respectively 1 and 3 MeV, showed a similarity of the results within 5%. Moreover, the sensitivity to detect V and Cr was improved, unlike Na for which the detection limit was worsened. Therefore, there is an important time saving aspect particularly when a considerable amount of material is to be analyzed. This means reducing time necessary for PIXE measurements as well as for spectra processing.

Acknowledgements We gratefully thank the International Atomic Energy Agency for the technical and financial support of the Lebanese accelerator project, as well as for the grant which allowed to attend this symposium. References [1] Ch. Lahanier, G. Amsel, Ch. Heitz, M. Menu, H. H. Andersen, Nucl. Instr. and Meth. B 14 (1986) 1. [2] S.A.E. Johansson, J.L. Campbell, Particle-Induced X-Ray Emission Spectrometry (PIXE), John Wiley & Sons, 1995. [3] M. Roumié, B. Nsouli, K. Zahraman, A. Reslan, Nucl. Instr. and Meth. B 219-220. [4] M. Roumié, S. Y. Waksman, B. Nsouli, P. Reynolds, S. Lemaître., Nucl. Instr. and Meth. B 215 (2004) 196. [5] M. Roumié, B. Nsouli, C. Atalla, S. Y. Waksman,, Nucl. Instr. and Meth. B 227 (2005) 584. [6] J.F. Harrison and R.A. Eldred, Adv. X-ray Anal. 17 (1973) 560. [7] J.A. Maxwell, W.J. Teesdale, J.A. Campbell, Nucl. Instr. and Meth. B 95 (1995) 407. [8] H.C. Romesburg, Cluster Analysis for Researchers, Lifetime Learning Publications, Belmont, 1984. [9] B.S. Everitt, Cluster Analysis, Hastled Press, New York, 1993. [10] PICON M., PACT 10: Revue du groupe européen d'études pour les techniques physiques, chimiques, biologiques et mathématiques appliquées à l'archéologie (1984) 379.